Tender For special Repair To Bidg No P-66, Mt Office And Stores Of Certain Mil Unit At Binnaguri Mil Stn, Provn Of Swage Line (200M) From Offcer Mess To Adm Block Of Certain Mil Unit At Binnaguri Mil Stn, Provn Of Septic Tank With Soak Pit Near Bldg
Tender Overview
Project Description
Tender for special Repair To Bidg No P-66, Mt Office And Stores Of Certain Mil Unit At Binnaguri Mil Stn, Provn Of Swage Line (200M) From Offcer Mess To Adm Block Of Certain Mil Unit At Binnaguri Mil Stn, Provn Of Septic Tank With Soak Pit Near Bldg No P-1 Of Certain Mil Unit At Binnaguri Mil Stn, Provn Of Interlocking Paver Block On Raod Side Of Umrao Vihar In Front Of Certain Mil Unit At Binnaguri Mil Stn, Provn Of Installation Of 02 X Elect Boom Barriers Near Gate No 1 And 2 Fasf Telipara, Provn Of Sewage Line Behind Or Living Of Certain Mil Unit At Binnaguri Mil Stn And Provn Of Toilet Cum Bathroom In Mt Area Of Certain Mil Unit At Binnaguri Mil Stn Under Ge(S) Binnaguri
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster on wall, ceiling, chajjas, roof projections, lintel, etc of any description including raking out joints, hacking for key and scrubbing down with water etc and disposing off the rubbish materials out side MD land complete all as specified |
| 2 | M&L for 20 mm thick rendering in cement mortar (1:4) on fair faces of brick work in two layers (10mm & 10mm) mixed with water proofing compound in top layer 200 ml per beg of cement or as per manufacturer's instructions finishing the surface fair and even without using extra cement complete all as specified Note: Water proofing compound shall be measured and paid seperately under relevant item of schedule 'A'. |
| 3 | Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified |
| 4 | M&L for 15mm thick rendering in cement mortar 1:6 on fair face/other than fair face of brick work or concrete surface finished fair and even (without using extra cement) complete all as specified |
| 5 | M&L for rendering 5mm thick in cement mortar 1:3 on ceiling, soffits of slabs, chajjas, columns and beams etc and finished the plastered surface even and smooth without using extra cement complete all as specified |
| 6 | M&L for preparing new Plastered surfaces of walls and applying two coats acrylic-based distemper of shade as approved by GE over a coat of primer over a coat of putty (average 1.5mm thick) on surfaces of wall as per the manufacturer's instructions complete all as specified and directed. Note: Application of new finishes to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. |
| 7 | M&L for complete removal of existing treatment of old plastered surfaces of walls and applying two coats acrylic based distemper of shade as approved by GE over a coat of primer over a coat of putty (average 1.50mm thick) on surfaces of wall including preparation as per the manufacturer's instructions complete all as specified Note: Application of new finishes to be carried out mechanically by authorised applicator and as per the manufacturer's instructions. |
| 8 | M&L for preparing new Plastered surfaces of walls and finishing the walls with Acrylic smooth exterior anti-fungal paint of required shade as approved by GE : New work (Two coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm) over and incl a coat of putty (average 1.50mm thick) complete all as specified |
| 9 | M&L for complete removal of existing treatment of old plastered surfaces of walls and finishing the walls with Acrylic smooth exterior anti-fungal paint of required shade as approved by GE : New work (Two coats applied @1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/ 10 sqm) over and incl a coat of putty (average 1.50mm thick) including preparation complete all as specified |
| 10 | M&L for preparing newly plastered or unplastered surface of ceiling and applying three coats of white washing complete all as specified |
| 11 | M&L for preparartion of old surfaces of ceiling & applying two coat of white washing complete all as specified |
| 12 | Demolition of brick work built in cement mortar of any description complete all as specified |
| 13 | M&L for brickwork with flyash old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified |
| 14 | M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified |
| 15 | Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles and rubbish off the premises complete all as specified |
| 16 | M&L for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tile, laid over and including 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified |
| 17 | M&L for 10 mm thick rendering/ backing coat in CM (1:3) as in vertical surfaces of skirting, dados etc complete all as specified |
| 18 | M&L for glazed ceramic coloured tiles/ digital elevation tiles of size 300 X 450 X 7-8 mm/300 X 600 X 7-8 mm thick as on vertical surfaces of wall such as skirting, dado, riser etc. in Bath, WC and Kitchen set and jointed in neat cement slurry and pointed in with tile grout of approved make to match the surface of tile as approved by Engr-in-Charge complete all as specified |
| 19 | Roughening the surfaces of old concrete floor by picking, sweeping, cleaning and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 kg of cement per Sqm complete all as specified |
| 20 | M&L for machine cut kota stone slab flooring 18-20mm thick with 18 -20mm thick white marble border 100mm wide laid over 20mm thick cement screed base in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete, including rounding the exposed edges of kota stone complete all as specified |
| 21 | M&L for machine cut kota stone slab flooring 18-20mm thick laid over 20mm thick cement screed base in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete, including rounding the exposed edges of kota stone complete all as specified |
| 22 | All as per item No 21 here in before but as in skirting, over shelf ( 12 to 15 mm thick) but on 15 mm thick rendering/ backing coat in CM (1:3) complete all as specified |
| 23 | M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, Flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 15 mm thick cement plaster (1:4) including rounding the exposed edges of granite complete all as specified |
| 24 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified |
| 25 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified |
| 26 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws/ L-type or J-type or cranked hook bolts in lieu of screw as per site requirement complete all as specified |
| 27 | Dismantling wall and ceiling board (fibre pulp, insulation etc) or insulation boards any thickness including cover fillets |
| 28 | S&F anodised aliminium snap grid frame work for false ceiling confirming IS:733, 737 & IS:1285; including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long all as specified |
| 29 | S&F 4mm thick (E-Boards) Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws in ceiling complete all as specified |
| 30 | Taking down tarfelt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m incl roughening of old concrete suirface of roof by wire brushing and cleaning the surface to remove all loose dust etc complete all as specified |
| 31 | M&L for water proofing treatment to RCC roof slab including parapet comprising of the following course of tretment/specified from bottom to top (a) Applying Bituminous primer @ 0.40 Ltr per Sqm over plastered surface of roof including parpet surfaces. Bitumnious primer shall be 'Tar Mastic' manufactured by M/S STP LTD or 'EMW FLATE; manufactured by M/S Texsa India Ltd. (b) Over the priming coat laying one layer APP based polymeric membrane with non woven polyster fabric weight not less than 160 gms per sqm. Polymeric membrane shall be taken to a height of 60cm (mim) and than inserted th groove of perafit wall and shall be finished a membrance flashing (c) Application of two coats of Bituminous aluminum paints over the polymeric memnrance after necessary preparation and cleaning, Thickness 3mm.Note :- Laying APP based polymeric membranceshall be done by tourch on mathod or as per manufacture insturction. (ii) A minimum overlap of 100 mm shall be maid at the end 75mm shall be maid at the side and sealed overlaped and joint as per manufacture instructions. Make :- \\"SUPER THERMOLAY\\" manufacturer by STP Ltd of MOPLY FP manufacture by Texsa India Ltd. |
| 32 | M&L for 10mm thick screedd bed or bedding layeres in cement mirter (1:4) in order to maintain proper slope over existing roof surface for applying single component acrylic polymner modified, fininshed even and smooth without using extra cement mixed with water proofing compound complete all specified and as directed. Note :- Polymeric membrane and WPC shall be measured and paid spearately under relevant items of this Sch 'A'. |
| 33 | M&L for 25mm thick PCC 1:2:4 type B0 (Using 12.5 mm graded stone aggregate) mixed with water proofing compound and laid on RCC slab as base layer for roof tratment rufning the topo surface of concrete by using broom stick while the cocrete is green complete all as specified. Note:- WPC paid separatly under relivant items. |
| 34 | S&F Powder coated aluminium window sliding type three track (2 glazed & one gauzed shutter) aluminium sections weighing not less than 1.25kg/m for frame and 0.45 kg/m for shutter including necessary jointing cleats, glazing cleats, rubber packing, screws, handle, locking arrangement and 5.5mm thick plain/tinted glass and aluminium mosquito proof gauge including taking down of old existing steel window with guard bars and making good disturbed surfaces of wall complete all as specified |
| 35 | S&F Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; frame work of water tanks and similar work conforming to Fe290,Gde-E-165 complete all as specified |
| 36 | M&L for preparation of new of previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified |
| 37 | Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm but n exc 4 sqm each and removal from site including cutting holes for taking out hold fast or dismantling brick work/ stone work (holes cut and any other damage to jambs walls for taking out hold fast shall be finished identical to existing finish without extra cost to the Govt) complete all as specified. |
| 38 | S&F pressed steel frames of size 105x60 mm for doors with one or more rebates including supply and fixing necessary lugs, hinges, lock strike plate, etc. including one soap coat of priming complete all as specified Note:- The sizes/dimensions and type (profile) of frames shall be as shown in I.S. |
| 39 | S&F 30 mm thick flush shutter, solid core construction, with block board core and plywood face panel, commercial type on both side etc complete all as specified |
| 40 | M&L for preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified |
| 41 | M&L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for filing hollow space of steel chowkhats, fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified |
| 42 | S&F 140 mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified |
| 43 | S&F aluminium anodised barrel tower bolts of extruded section 200 mm long complete all as specified |
| 44 | S&F aluminium handles 150mm size cast type anodised complete all as specified |
| 45 | S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all specified |
| 46 | S&F in repair stainless steel curtain rod of 25 mm dia and thickness not less than 0.75 mm fixed with curtain rod holder and finials etc. complete all as specified |
| 47 | Demolition of cement concrete (un-reinforced) any description and in any position not otherwise specifically provided for complete all as specified |
| 48 | M&L for PCC 1:2:4 type B-0 (using 12.5mm graded agg) 25 mm thick (average) stone aggregate as in sub base, levelling course to receive floor topping complete all as specified |
| 49 | M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, finishing cement concrete surface even & fair without using extra cement including filiing the joints with bitumen & sand in 2:1 proportion etc complete all as specified |
| 50 | M&L for PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in surface channel or drain including use of necessary from work for fair finished surface complete all as specified |
| 51 | M&L for rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. Fe 410-W (Gde-E- 250) quality-A including dismantling |
| 52 | Removing building materials and debris (other than excavated earth) to a distance of 5 KM inside MD Land at locations specified including loading and dumping/ leveling at the destination complete all as specified |
| 53 | M&L for preparation of old steel surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified |
| 54 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified |
| 55 | S&F 20mm thick second class hardwood boarding planed one side, with butt joints and fixed with nails complete all as specified |
| 56 | M&L for preparation of old wooden surface of any description over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified |
| 57 | Demolition of Reinforced cement concrete of roofs, floors (other than ground floors), beams, staircase, landings, chajjas, facia and similar suspended work complete all as specified |
| 58 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified |
| 59 | M&L for point wiring complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated, IS 694 unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less than 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes duly painted with anticorrosive paint, concealed in walls with bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sunken for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications all as specified for the following :- |
| 60 | (a) One light point controlled by one way switch 5/6 amps. |
| 61 | (b) One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps. |
| 62 | (c) One socket out let 5/6 amps point on the same board |
| 63 | (d) One socket out let 5/6 amps point on the independent board |
| 64 | All as per item No 59 above but wiring with 2.5 sq mm single core copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified ed. |
| 65 | S&F switch piano flush type 5/6 amps single pole one way complete all as specified |
| 66 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified |
| 67 | S&F of socket outlet 2 in 1, 5 Pin, 5/15 amp, multipurpose 230 volt flash type complete all as specified |
| 68 | S&F switch piano flush type 15/16 amps single pole one way complete all as specified |
| 69 | S&F Ceiling rose, surface type with back plate, three terminal /PVC/ polycarbonate, isolated body complete all as specified |
| 70 | S&F LED lights fitting 1x 20W, 220V AC decorative box type with driver,IP 20, class I, wall/ surface mounted, integrated type with extruded aluminium housing integrated high efficiency electronic driver and surge suppressor of 4KV or more, luminaire efficiency not less than 120 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified. |
| 71 | S&F LED Bulk Head lights fitting 1x 9/10W, 220V AC integrated high efficiency electronic driver and surge suppressor of 4KV or more, luminaire efficiency not less than 120 lumens/watt, power factor not less than 0.90, CRI 80, THD 10%, operating range - 140 to 270 V, 50 Hz fixed etc connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified. |
| 72 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with din rail, IP-20 protection suitable for fixing MCB\\"S/lsolators complete including provision of blanking plates as required and taking down the old one complete all as specified |
| 73 | S&F MCB, Single pole & neutral 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete including taking down the old one complete all as specified |
| 74 | S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘B’ curve, 10 KA all complete including taking down the old one complete all as specified |
| 75 | M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified |
| 76 | Taking down carefully Ceiling fan from its original position and M&L for painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc, all as specified and as directed.and refixing / hanging after B/R plaster work complete all as specified |
| 77 | M & L Sub main wiring concealed type with two run single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 6.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size, making good the disturbed surfaces complete including necessary taking down.(NOTE : Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length. |
| 78 | Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out in soft/loose soil complete all as specified |
| 79 | M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified |
| 80 | Removing of surplus soil/excavated materials to a distance not exc 50 m away from the starting point and depositing where directed at a level not exc 1.5m above the ground level complete all as specified |
| 81 | M&L PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) for fdn/ mass concrete complete all as specified |
| 82 | M&L PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) for making of chamber base all as specified |
| 83 | Material and labour for brick work with sub-class ‘B’ bricks, set in cement morter (1:4) straght or curved on plan, exceeding 6m mean redious as in manholes and septic tanks complete all as specified |
| 84 | M&L for rendering 15mm thick in CM 1:3 as in fair faces of brick work or concrete surface of wall and finished surface even and fair without using extra cement with using wpc as per manufacturer instruction (measure seperately)complete all as specified |
| 85 | Material and labour for PCC (1:2:4) type B-1 (using 20 mm graded aggregate) as in coping of manholes channels etc complete all as specified |
| 86 | M & L for precast RCC (1:2:4) type B1 using 20mm graded stone aggregate as in cover slabs of drains set in CM (1:6) including necessary form work complete all as specified |
| 87 | Supply and fixing for mild steel TMT bars, 10 mm dia, cut to length, bent to shape as required including cranking, bending and binding with mild steel wire (annealed)not less than 0.90 mm dia complete all as specified |
| 88 | S/F SGSW drain pipe of size 200 mm dia (grade A) laid in trenches and jointed in cement mortar (1:1) complete all as specified |
| 89 | M&L for concrete bed in cement concrete 1:3:6 type C2 to drain pipes of 200 mm bore including packing under and hunching against the sides of pipes after they are laid and tested complete all as specfied |
| 90 | Cutting into existing man holes for connecting new drain of 200mm dia pipe and making good two pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 and finished and reforming benching as required complete all as specified |
| 91 | Excavation over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified |
| 92 | Excavation over areas, exc 1.5 m and n. exc 3 M deep and getting out in any type of soil complete all as specified |
| 93 | M&L for providing plain cement concrete (M-10) (1:3:6) type C-2, (using 40 mm graded stone aggregate), as in foundations, filling and mass concrete complete all as specified . |
| 94 | M&L for Reinforced cement concrete1:1.5:3 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified |
| 95 | M&L for Reinforced cement concrete 1:1.5:3as in columns, pillars, piers, posts and struts complete all as specified |
| 96 | M&L for Reinforced cement concrete 1:1.5:3 as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified |
| 97 | M&L for Reinforced cement concrete 1:1.5:3 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified |
| 98 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for flat rough finished surfaces of concrete complete all as specified . |
| 99 | Use and waste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for flat rough finished surfaces of concrete complete all as specified |
| 100 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions Square, rectangular or polygonal rough finished surfaces of concrete complete all as specified |
| 101 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) flat rough finished surfaces of concrete complete all as specified |
| 102 | Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide rough finished surfaces of concrete complete all as specified |
| 103 | M&L for mild steel TMT bars 5mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified |
| 104 | Removing excavated material (soils) exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified |
| 105 | M&L for providing precast reinforced cement concrete (1:1.5:3) type A1 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in CM (1:4) including necessary use and waste of formwork complete all as specified. |
| 106 | S&F 100mm bore Cast iron (Spun pipes) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls with epoxy coating inside & outside complete all as specified |
| 107 | S&F 150mm bore Cast iron (Spun pipes) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls with epoxy coating inside & outside complete all as specified |
| 108 | S&F 100mm bore Cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified . |
| 109 | S&F 150mm bore Cast iron junction single, (Single T) equal or unequal complete all as specified |
| 110 | S&F 100mm bore cast iron cowls complete all as specified |
| 111 | S&F 200mm bore reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified |
| 112 | M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipes including packing under & haunching against the sides of pipes after they are laid & tested bore of pipe 200mm complete all as specified. |
| 113 | M&L for PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in coping/ benching for man holes including necessary use and waste of formwork complete all as specified. |
| 114 | M&L Brickwork with sub class‘B’ bricks in one brick thick honey comb walling, built in cement mortar 1:4 complete all as specified. |
| 115 | M&L Broken brick coarse aggregate nominal size 40-63 mm filled in layers complete all as specified |
| 116 | M&L for rendering 15 mm thick cement plaster in CM 1:4 on fair faces of brick/concrete work surfaces in two layer 10mm each layer and top layer mixed with integral water proofing compound all as per manufacturer's instruction and as specified.Note: (i) WPC shall be measured and paid for separately as 'Supply only'.(ii) WPC to be mixed @200ml per 50 Kg bag of cement all as manufacturers instruction. |
| 117 | M&L for preparation of new of previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified |
| 118 | Surface excavation n.exc (not exceeding) 7.50 cm deep and averaging 15cm deep and getting out complete all as specified |
| 119 | M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified |
| 120 | M&L for cement concrete type D-2, 1:4:8(40mm graded aggregate) 100mm thick complete all as specified |
| 121 | M&L for cement concrete type B-2, 1:2;4 (40 mm graded aggregate) 100mm thick complete all as specified |
| 122 | Add to (or deduct from) last item for every 3 cm or part thereof above orbelow 15 cm average depth |
| 123 | M&L 80 mm thick M-30 grade factory made vibratory compacted cement concrete rubber moulded, interlocking paver block any shape and size confiroming to IS 15658-2006 with grey cement and pigment as approved laid over and incl 50 mm thick consolidated sand cushion and joints filled with sand complete all as specified |
| 124 | M & L for providing and laying at or near ground level factory made kerb stone (300 x 300x 100 mm) of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 125 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, complete all as specified |
| 126 | S&F Sheet metal enclosure for 2 way Distribution Boards (DB’s), single door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete as specified |
| 127 | Supply, Installation and Testing of Electric Operated Boom Barrier 6 mtr long with control unit, MS housing with Zinc Coating and Anti corrosive treatment, Push Button and Remote control,230V, AC 50Hzs, 120W, Electro-mechanical mechanism for operation, IP54 with warning and traffic lights, reflacting tape, Rubber buffer, Open/cloas with mechanical handle in case of power failure complete all as per site requirement and as specified |
| 128 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified . (Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I) |
| 129 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified |
| 130 | Supply and fixing 40 mm dia GI tubing medium grade ISI marked laid in trenches / laid under floor for protection of cable including all fittings such as elbow, bends, etc and short length complete all as specified |
| 131 | M&L Cement concrete in foundations, filling and mass concrete Type B2 ( 1:2:4) 40mm aggregate complete all as specified. |
| 132 | S&F in salt-glazed stoneware gully traps, square or round mouthed, type 'P' fo size 180X150mm complete all as specfied |
| 133 | Supply and fixing for mild steel TMT bars, 8mm dia, cut to length, bent to shape as required including cranking, bending and binding with mild steel wire (annealed)not less than 0.90 mm dia complete all as specified |
| 134 | M&L for surface dressing n exc 15 cm deep for adjoining area complete all as specified |
| 135 | All as per item No 130 here-in-before but 6 to 8 mm dia as in stirrups complete all as specified |
| 136 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing on SI page No 156 of SSR Part-II complete all as specified |
| 137 | S&F Solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, supplying and fixing in opening as per specification and drawing on SI page No.160 of SSR Part-II complete all as specified |
| 138 | S&F factory made steel ventilator with top hung shutter including friction/ box type hinges ,steel peg stay complete including taking out old/unserviceable steel ventilator and making good to match as per existing surfaces etc complete all as specified |
| 139 | S&F 250mm long aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section complete all as specified |
| 140 | M&L for 150 mm size aluminium anodised cast type handles complete all as specified and directed complete all as specified |
| 141 | S&F of 150mm long aluminium anodised,barrel tower bolt of extruded section complete all as specified |
| 142 | S&F 100mm size stainless steel butt hinges medium weight complete all as specified |
| 143 | M&L for applying two coats of weather proof exterior acrylic emulsion paint of standard quality and make, over a coat of white primer including preparation of new /old wall surfaces complete all as specified |
| 144 | M&L for applying three coat of white washing including preparation of new or previously untreated surface of ceiling complete all as specified |
| 145 | M&L for for preparation of newly wall plastered surfaces and applying three coats of colour wash on wall as specified |
| 146 | M&L for coloured joint free non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors, skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile including 15mm thick screed bed in cement mortor 1:6 complete all as specified |
| 147 | M&L for glazed ceramic colour tiles 450X 350X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile 10mm thick rendering on fair faces of brick work or concrete surface in CM 1:3 for laying wall tiles. approved complete all as specified |
| 148 | S&F 4mm thick figured glass pin headed type n.exc 0.5sqm each fixed to steel frame complete all as specified |
| 149 | Materials and labour for 75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in sub-base of floor over and including 50 micron polythene film laid complete all as specified |
| 150 | S&F wash hand basin, vitreous china, white, flat back (550x400mm) cutting for and pinning ends of brackets(Make:Parryware Code No.-0471,Indus Basin (white) or equivalent and waste fitting,brass chromium plated for glazed ware basin etc with long screwed shanks and fly nuts,flange end bedded in red lead cement and other end fixed 32mm including PVC waste pipe with CP /PTMTcoupling of required length. |
| 151 | M&L for CI Nahani trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1(diameter of outlet 100mm) complete all as specified |
| 152 | Supply & fix angular stop cock made of brass chromium plated screwed both ends for iron pipe for 15mm bore complete all as specified |
| 153 | Supply & fix Bib tap cast copper alloy, chromium plated with crutch or butterfly handle, screwed down for 15mm bore GI Pipe or for brass ferrule including taking down old unserviceable one complete all as specified |
| 154 | S&F PVC low level flushing cistern, 10 ltr capacity, syphonic action type white body with inlet ball valve, float , handle, bracket, long flush pipe of PVC to suit flushing cistern ( long bend) etc complete & connecting to WC,complete all as specified |
| 155 | S&F central hole basin mixer for WHB complete all as specified |
| 156 | S&F Brass CP mixer for mixing hot & cold water screweddown for iron pipeand fixed complete all as specified |
| 157 | S&F tubular towel rail 20mm dia D type, Brass Chromium Plated 60 cm long between flanges complete all as specified |
| 158 | S & F stainless steel soap dish best quality fixed to plugs with chromium plated brass complete all as specified |
| 159 | S&F of PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified |
| 160 | S&F Water Closet (squatt pattern) of vitruous china squatting pan of pattern \\"ORRISA\\" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cirstern and flush pipe) including connection to trap and flushing pipe anti syphon pipe etc complete including trap set in and incl concrete complete all as specified |
| 161 | S&F 600 x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC bldg board or commercial plywood and fixed to wooden plug with chromium plated brass screws & cup washers complete all as specified |
| 162 | M&L Gun-metal, globe or gate valves,15mm bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified |
| 163 | S&F swivel shower of CP with shower arm 125 mm size for fixing with 15 mm bore GI pipe complete all as specified |
| 164 | S&F PVC (SWR) (Bore of pipe 110mm) pipes single socketed, in any length with rubber ring joints fixed to walls with necessary clamps, bolts etc complete all as specified |
| 165 | S&F PVC (SWR) bends any radius fixed to PVC Pipes/Steel Gutters (Bore of pipe 110mm) complete all as specified |
| 166 | S&F PVC (SWR) vent cowl fixed to PVC Pipes (Bore of pipe 110mm) complete all as specified |
| 167 | Cutting chases, pinning in, making good to facing where required and pointing in CM 1:3 for concealed water tubing and making good, cutting n.exc 10cm girth as in brick/stone or concrete block walls complete all as specified |
| 168 | M & L for 15 mm bore steel tubing medium grade,galvanised fitting fixed complete to walls and ceiling or floor complete all as specified |
| 169 | All as per item No 164 above but 20mm , complete all as specified |
| 170 | M&L for mild steel rolled sections conforming to Fe - 410 (Gde E-250) as in main and cross beams, hip and jack rafters; verticals , purlins where connected to common rafter and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified |
| 171 | S & F 1000 ltrs rotational moulded polyethelene water storage tanks (cyclindrical vertical with closed top) incl connecting up pipes securing access covers etc as complete all as specified |
| 172 | S&F 20 mm dia PVC ball cock (PVC float valves) complete high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed as required to use reducer and check nut complete all as specified |
| 173 | M&L for point wiring for one light /fan point complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated, IS 694 unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less than 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, fabricated sunken terminal box made out of GI sheet steel not less than 1.22 mm thick for boxes duly painted with anticorrosive paint, concealed in walls with bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sunken for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications all as specified |
| 174 | S&F Exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with blades,frame and louvers complete with making hole in wall and fixing accordingly all as specified |
| 175 | S&F ceiling rose surface backelite 65x50mm two to three terminal (ISI marked). |
| 176 | S & F MCB DB confirming to IP 43 - IK 09 with acrylic door, 4 way double door complete with all connections -Phase, Neutral and Earthing bar and making good the disturbed surfaces.Complete all as specified |
| 177 | Supply installation, commissioning and testing of electric water heater, storage vertical type, BEE 5 star rated 25 ltrs capacity 230 volts AC 50 Hz comprising of high wattage heating element for instant heating extra thick SS inner tank of superior 304 grade, rust & shock proof ABS outer body, non- ferrous prewssure plate with and including provision of 04 Nos grouting bolts suitably flush to wall or any other surfaces 25 lts BEE 5 Star rated complete stranded copper conductor cable/ flexible chord complete all as specified |
| 178 | Supply and laying/ fixing on wall GI water Tubing medium grade of 25 mm dia including all fittings such as sockets, bends, elbows, Union etc . Complete all as specified |
| 179 | Material and labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete all as specifiedNOTE : Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender