Heavy Industries and Public Enterprises Boards / Undertakings / PSU Closing in 19 days TDR #57558185

Bids Are invited for Fuel Contamination Tester - Mk1a-30288/Rt-1 - Supply, Installation & Commissioning Of Fuel Contamination Tester Along With Additional Accessories And 12 Months Warranty As Per Technical Specification , Portable Laboratory Model L

Issued by Boards / Undertakings / PSU · Bangalore, Karnataka
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Oct 2026
19 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bangalore → Karnataka
EMD Exemption
Available
Quantity
2

Project Description

Bids Are invited for Fuel Contamination Tester - Mk1a-30288/Rt-1 - Supply, Installation & Commissioning Of Fuel Contamination Tester Along With Additional Accessories And 12 Months Warranty As Per Technical Specification , Portable Laboratory Model Liquid Particle Counter With Integrated S Ling And Measurement Capability For Particles Counting And Sizing As Per Iso 4406©, Nas 1638, Particle Count And Sizing In Aviation Turbine Fuel, Jet Fuel According To Def Stan 91-091 And Ip 577 , 8 Channels , 10 Ml/Min. , A. Customizable Measurement Setting With User Defined Parameters , Light Obscuration Principle/ Light Extinction Principle , Hcb-Ld-50/50 , Volumetric Cell Design For Maximum Particle Concentration , Laser Light Source/ Laser Diode , 2 - 200 Micron , 500 X 500 Microns , 24,000 Particle/Ml , 7.8% At Maximum Particle Concentration , Automatic S Le Flow And Volume Control Via Wear Resistant Ceramic Piston Pump , Offline And Online S Le Analysis , Online Pressurised S Ling Upto Maximum Of 6 Bars. , Max. 5Cst @ 22 Degc , User Defined ( Typically 10Ml) , User Defined ( Typically 100Ml) , 10 To 60 Deg C , 220-240 Vac, 50Hz , 5-70 ˚C With Relative Humidity Max. 70% Rh , Lcd Display With Touchscreen And Keypad. Operational Parameters And Settings In Menu Functions , Rs-232 /Usb Interface , Rs-232/Usb Interface , Display Results Of Particle Size And Particle Numbers, Display Iso 4406©/ Sae/Def Class/ Nas 1638 Class , Data Storage Of Results For Upto 3000 Measurement Data With Facility To Recall/Retrieve/Print Results , A. Calibration According To Iso 11171 For 4-70 Μm (For Reporting Iso 4406 Class) (Or)B. Calibration According To Iso 4402 For 2-100 Μm (For Reporting Nas 1638 Class) , A. 4-70 Micron (Standard Calibration Of The Equipment To Iso 11171) (Or)B. 2-100 Micron (Optional/ Additional Calibration According To Iso 4402) , A. 4-70 Micron (As Per Standard Calibration Of The Equipment ) - Reporting To Iso 4406 And Sae Classs (Or)B. 2-100 Micron (Optional Calibration Provision As Per Iso 4402) - Reporting To Nas 1638 Class , Windows Compatible Software To Download Data To Pc And Storage Of Results In Computer. , 3 Sets Of Hard Copy And 1 Set Soft Copy Of User/Operation Manual In English , 12 Months From The Date Of Installation And Commissioning , Supplier Has To Install The Equipment Premises Within 10 Days After Confirmation Of Readiness Of The Site By Hal.Operation And General Maintenance Training Needs To Be Provided Dusing Installation And Commissioning. Supplier Has To Provide Any Additional Accessories Required For The Installation And Commissioning Of The Equipment.Onsite/ Offsite/ Local Service And Calibration Support In India , Optional External Degasser For Degassing S Les To Remove Air-Bubbles , S Le Bottle (500 Ml) - 10Nosthermal Printer Paper Rolls - (05 Nos)

BOQ

Sl. No. Item TitleItem Description
1Supply, Installation & Commissioning of Fuel Contamination Tester along with additional accessories and 12 months warranty as per Technical SpecificationSupply, Installation & Commissioning of Fuel Contamination Tester along with additional accessories and 12 months warranty as per Technical Specification
2Portable laboratory model Liquid Particle Counter with integrated sampling and measurement capability for Particles Counting and Sizing as per ISO 4406©, NAS 1638, Particle Count and Sizing in Aviation Turbine Fuel, Jet Fuel according to DEF STAN 91-091 and IP 577Portable laboratory model Liquid Particle Counter with integrated sampling and measurement capability for Particles Counting and Sizing as per ISO 4406©, NAS 1638, Particle Count and Sizing in Aviation Turbine Fuel, Jet Fuel according to DEF STAN 91-091 and IP 577
38 channels8 channels
410 ml/min.10 ml/min.
5A. Customizable measurement setting with user defined parametersA. Customizable measurement setting with user defined parameters
6Light Obscuration Principle/ Light Extinction PrincipleLight Obscuration Principle/ Light Extinction Principle
7HCB-LD-50/50HCB-LD-50/50
8Volumetric cell design for maximum particle concentrationVolumetric cell design for maximum particle concentration
9Laser Light Source/ Laser diodeLaser Light Source/ Laser diode
102 - 200 micron2 - 200 micron
11500 x 500 microns500 x 500 microns
1224,000 particle/ml24,000 particle/ml
137.8% at maximum particle concentration7.8% at maximum particle concentration
14Automatic sample flow and volume control via wear resistant Ceramic piston pumpAutomatic sample flow and volume control via wear resistant Ceramic piston pump
15Offline and Online Sample AnalysisOffline and Online Sample Analysis
16Online pressurised sampling upto maximum of 6 bars.Online pressurised sampling upto maximum of 6 bars.
17Max. 5cSt @ 22 degCMax. 5cSt @ 22 degC
18User defined ( Typically 10ml)User defined ( Typically 10ml)
19User defined ( Typically 100ml)User defined ( Typically 100ml)
2010 to 60 deg C10 to 60 deg C
21220-240 VAC, 50Hz220-240 VAC, 50Hz
225-70 ˚C with relative humidity max. 70% RH5-70 ˚C with relative humidity max. 70% RH
23LCD display with touchscreen and keypad. Operational parameters and Settings in Menu functionsLCD display with touchscreen and keypad. Operational parameters and Settings in Menu functions
24RS-232 /USB interfaceRS-232 /USB interface
25RS-232/USB interfaceRS-232/USB interface
26Display results of particle size and particle numbers, Display ISO 4406©/ SAE/DEF class/ NAS 1638 classDisplay results of particle size and particle numbers, Display ISO 4406©/ SAE/DEF class/ NAS 1638 class
27Data Storage of results for upto 3000 measurement data with facility to recall/retrieve/print resultsData Storage of results for upto 3000 measurement data with facility to recall/retrieve/print results
28A. Calibration according to ISO 11171 for 4-70 μm (for reporting ISO 4406 class) (OR)B. Calibration according to ISO 4402 for 2-100 μm (for reporting NAS 1638 class)A. Calibration according to ISO 11171 for 4-70 μm (for reporting ISO 4406 class) (OR)B. Calibration according to ISO 4402 for 2-100 μm (for reporting NAS 1638 class)
29A. 4-70 micron (standard calibration of the equipment to ISO 11171) (OR)B. 2-100 micron (optional/ additional calibration according to ISO 4402)A. 4-70 micron (standard calibration of the equipment to ISO 11171) (OR)B. 2-100 micron (optional/ additional calibration according to ISO 4402)
30A. 4-70 micron (as per standard calibration of the equipment ) - Reporting to ISO 4406 and SAE Classs (OR)B. 2-100 micron (optional calibration provision as per ISO 4402) - Reporting to NAS 1638 classA. 4-70 micron (as per standard calibration of the equipment ) - Reporting to ISO 4406 and SAE Classs (OR)B. 2-100 micron (optional calibration provision as per ISO 4402) - Reporting to NAS 1638 class
31Windows compatible Software to Download data to PC and storage of results in computer.Windows compatible Software to Download data to PC and storage of results in computer.
323 sets of hard copy and 1 set Soft copy of user/operation manual in English3 sets of hard copy and 1 set Soft copy of user/operation manual in English
3312 months from the date of installation and commissioning12 months from the date of installation and commissioning
34Supplier has to install the equipment premises within 10 days after confirmation of readiness of the site by HAL.Operation and general maintenance training needs to be provided dusing installation and commissioning. Supplier has to provide any additional accessories required for the installation and commissioning of the equipment.Onsite/ Offsite/ Local service and calibration support in IndiaSupplier has to install the equipment premises within 10 days after confirmation of readiness of the site by HAL.Operation and general maintenance training needs to be provided dusing installation and commissioning. Supplier has to provide any additional accessories required for the installation and commissioning of the equipment.Onsite/ Offsite/ Local service and calibration support in India
35Optional External Degasser for degassing samples to remove air-bubblesOptional External Degasser for degassing samples to remove air-bubbles
36Sample bottle (500 ml) - 10NosThermal Printer paper rolls - (05 Nos)Sample bottle (500 ml) - 10NosThermal Printer paper rolls - (05 Nos)

AI Tender Summary

OUR REF NO 57558185
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 08-10-2026
Authority
Authority Name Hindustan Aeronautics Limited
Work Description Bids Are invited for Fuel Contamination Tester - Mk1a-30288/Rt-1 - Supply, Installation & Commissioning Of Fuel Contamination Tester Along With Additional Accessories And 12 Months Warranty As Per Technical Specification , Portable Laboratory Model Liquid Particle Counter With Integrated S Ling And Measurement Capability For Particles Counting And Sizing As Per Iso 4406©, Nas 1638, Particle Count And Sizing In Aviation Turbine Fuel, Jet Fuel According To Def Stan 91-091 And Ip 577 , 8 Channels , 10 Ml/Min. , A. Customizable Measurement Setting With User Defined Parameters , Light Obscuration Principle/ Light Extinction Principle , Hcb-Ld-50/50 , Volumetric Cell Design For Maximum Particle Concentration , Laser Light Source/ Laser Diode , 2 - 200 Micron , 500 X 500 Microns , 24,000 Particle/Ml , 7.8% At Maximum Particle Concentration , Automatic S Le Flow And Volume Control Via Wear Resistant Ceramic Piston Pump , Offline And Online S Le Analysis , Online Pressurised S Ling Upto Maximum Of 6 Bars. , Max. 5Cst @ 22 Degc , User Defined ( Typically 10Ml) , User Defined ( Typically 100Ml) , 10 To 60 Deg C , 220-240 Vac, 50Hz , 5-70 ˚C With Relative Humidity Max. 70% Rh , Lcd Display With Touchscreen And Keypad. Operational Parameters And Settings In Menu Functions , Rs-232 /Usb Interface , Rs-232/Usb Interface , Display Results Of Particle Size And Particle Numbers, Display Iso 4406©/ Sae/Def Class/ Nas 1638 Class , Data Storage Of Results For Upto 3000 Measurement Data With Facility To Recall/Retrieve/Print Results , A. Calibration According To Iso 11171 For 4-70 Μm (For Reporting Iso 4406 Class) (Or)B. Calibration According To Iso 4402 For 2-100 Μm (For Reporting Nas 1638 Class) , A. 4-70 Micron (Standard Calibration Of The Equipment To Iso 11171) (Or)B. 2-100 Micron (Optional/ Additional Calibration According To Iso 4402) , A. 4-70 Micron (As Per Standard Calibration Of The Equipment ) - Reporting To Iso 4406 And Sae Classs (Or)B. 2-100 Micron (Optional Calibration Provision As Per Iso 4402) - Reporting To Nas 1638 Class , Windows Compatible Software To Download Data To Pc And Storage Of Results In Computer. , 3 Sets Of Hard Copy And 1 Set Soft Copy Of User/Operation Manual In English , 12 Months From The Date Of Installation And Commissioning , Supplier Has To Install The Equipment Premises Within 10 Days After Confirmation Of Readiness Of The Site By Hal.Operation And General Maintenance Training Needs To Be Provided Dusing Installation And Commissioning. Supplier Has To Provide Any Additional Accessories Required For The Installation And Commissioning Of The Equipment.Onsite/ Offsite/ Local Service And Calibration Support In India , Optional External Degasser For Degassing S Les To Remove Air-Bubbles , S Le Bottle (500 Ml) - 10Nosthermal Printer Paper Rolls - (05 Nos)
Basic Detail
Tender No GEM/2026/B/8046881
Bidding Type Tender
Location
City Bangalore
State Karnataka
Key Dates
Publish Date 17 Sep 2026
Submission Date 08 Oct 2026
Open Date 09 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Available
Document List
e20deaa1-6603-4f6b-826b-586ef7b52555.pdf
technical_compliance_statement_2026-09-17-10-48-43_b70b4530a888addb03caeafb93861a38.xls
annexure-a_tender_terms_and_conditions_2026-09-17-10-48-43_8f56f48bbc64f79ed63d612aa97dda1a.pdf
appendix_2026-09-17-10-48-43_93332929bb2107601f7f9bb5f2f2ceef.pdf
tender_notice_2026-09-17-10-48-43_aa3b3966dde98fa001c8d7a68cf7f510.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
pdf

e20deaa1-6603-4f6b-826b-586ef7b52555.pdf

xls

technical_compliance_statement_2026-09-17-10-48-43_b70b4530a888addb03caeafb93861a38.xls

pdf

annexure-a_tender_terms_and_conditions_2026-09-17-10-48-43_8f56f48bbc64f79ed63d612aa97dda1a.pdf

pdf

appendix_2026-09-17-10-48-43_93332929bb2107601f7f9bb5f2f2ceef.pdf

pdf

tender_notice_2026-09-17-10-48-43_aa3b3966dde98fa001c8d7a68cf7f510.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders