Tender For Maintenance Of Electrical Installation In Non-Residential Building At Chandigarh. (Replacement Of Defective Electrical Wiring, Accessories And Switchgear In Various Govt. Schools, Creches, Hwc Etc. In Daria, Raipur Kallan, Hallomajra, Maul
Tender Overview
Project Description
Tender for Maintenance Of Electrical Installation In Non-Residential Building At Chandigarh. (Replacement Of Defective Electrical Wiring, Accessories And Switchgear In Various Govt. Schools, Creches, Hwc Etc. In Daria, Raipur Kallan, Hallomajra, Maulijagran, Behlana, Raipur Khurd, Ramdarbar (Karsan) And Makhanmajra, U.T., Chandigarh).
BOQ
| Sl. No. | Item Description |
| 1 | DSR item No.1.8 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group-C |
| 3 | DSR item No.1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 4 | Group-C |
| 5 | DSR item No. 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 6 | Group-C |
| 7 | DSR item No. 1.17 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 8 | 3 x 1.5 sq. mm |
| 9 | 3 x 2.5 sq. mm |
| 10 | 3 x 4 sq. mm |
| 11 | DSR item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 12 | 20 mm |
| 13 | 25 mm |
| 14 | DSR 1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 15 | 5/6 A switch |
| 16 | 15/16 amps switch |
| 17 | 3 Pin 5/6 A. socket outlet |
| 18 | 6 Pin 15/16 A. socket outlet |
| 19 | DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 20 | 5/6 A switch |
| 21 | 15/16 A switch |
| 22 | 3 pin 5/6 A socket outlet |
| 23 | 6 pin 15/16 A socket outlet |
| 24 | 2 way 5/6 A. switch |
| 25 | DSR 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 26 | DSR 1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 27 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without (MCB/RCCB/Isolator) |
| 28 | 4 way (4 + 12), Double door |
| 29 | 6 way (4 + 18), Double door |
| 30 | 8 way (4 + 24), Double door |
| 31 | DSR item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 32 | Single pole |
| 33 | Double pole |
| 34 | Triple Pole & Neutral |
| 35 | DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 36 | 100 A,30KA,FPMCCB |
| 37 | 200 A,36KA,FPMCCB |
| 38 | DSR item No.8.9 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). (Please refer DNIT for complete specification of item no.13) |
| 39 | 18- 22 Watt |
| 40 | DSR item No.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). (Please refer DNIT for complete specification of item no.14) |
| 41 | 100 Watt. |
| 42 | S/E of 3mm thick white glazed Bakelite sheet on the existing M.S box. The job includes the cost of sheets and making holes and cutting charges of switches & sockets. The job includes the cost of all labour & petty material required to complete the job. |
| 43 | Supply & Laying of PVC insulated sheathed aluminium conductor un armored cable 10 mm. sq. 2 core flat with 8 SWG G.I. earth wire on existing surface with suitable clamps / hanger etc. including making connection and petty material etc. as required. The cable should be of Polycab/ Havells/ RR Kabel/ KEI/ Finolex make only. |
| 44 | S/E of Bakelite holder ISI marked installed on exiting Jn. Box/ wooden block including connection etc as required. The holder should be of Anchor (Penta)/ Havells (Reo)/ SSK make only. |
| 45 | Supply and laying of XLPE insulated PVC sheathed Aluminum conductor armoured cable of 1.1 KV grade as per IS 7098 (Part-I) 1988 (amended up to date) of the following sizes to be laid in existing Trench/Ducts/Cable Tray/ RCC/ HUME/ METAL/ DWC pipe / on surface with the help of MS clamps of suitable size/ as required at site to the entire satisfaction of Engineer-in-Charge. The job includes labour charges of laying the cable and making connections with suitable size aluminum lugs/thimbles etc. The cable shall be of Polycab / Havells / R.R. Kabel/ KEI/ Finolex make only. |
| 46 | 16 sq.mm 4 core (In pipe) |
| 47 | 10 sq.mm 4 core (On surface) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender