Tender For Construction Of 04 Acr At High School Pandeybara In Block Chouparan
Tender Value
60.77 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
13 days left
EMD
1.21 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hazaribagh → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 04 Acr At High School Pandeybara In Block Chouparan
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item - A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 2 | Earth work in excavation in foundation trenches in hard soil (vide classification of soil item - A+B) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 3 | Earth filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 4 | Earth work in filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50m and lift of 1.5m all complete as per specification and direction of E/l. |
| 5 | Supply of fine agreegate/stone dust all complete job. |
| 6 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume) |
| 7 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 8 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 9 | Providiag designation 75B brick work in Cement Mortar (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing taxes and royalty all complete job as per building specificition and direction of E/l. |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 11 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 14 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns etc. for mass concrete. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and platform. |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases. |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges. |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 22 | 8mm dia bar |
| 23 | 10mm dia bar |
| 24 | 12mm dia & above bar |
| 25 | Supplying, Fitting and fixing M.S grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, hoisting carriage of grill to work site hoisting as per building specification and direction of E/I. |
| 26 | Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 27 | Supplying, fitting and fixing 20 gauge G.C.I. sheet gate fitted on. M.S. angle frame of size 60 x 60 x 6mm including cost of fabrication providing necessary locking arrangement with haskal end dommy duly fixed in P.C.C. (1:2:4) block of required size, applying a priming red lead paint over steel work taxes all complete as per drawing specification and direction of E/I. |
| 28 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 29 | Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.600X600 mm size |
| 30 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 31 | Providing 12 mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direcition of E/l. |
| 32 | Providing 6mm cement plaster (1:4) in ceiling with clean coarse sand of F.M 1.5 including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I. |
| 33 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 34 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 35 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 36 | Lettering with black Japan paint of approved brand and manufacture. |
| 37 | Providing two coat of synthetic enamel paint over primer one coat of red lead paint of approved shade and make over steel surface including cleaning the surface throughly, scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 38 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 39 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) 75mm dia Single socketed pipes. |
| 40 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) 110mm dia Single socketed pipes. |
| 41 | Coupler - 110mm |
| 42 | Bend 87.5° - 75mm |
| 43 | Bend 87.5° - 110mm |
| 44 | Shoe (Plain) - 110mm |
| 45 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm |
| 46 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 47 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 48 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 49 | Cost of drilling 200mm x 165mm x 100m deep bore well in all kinds of soil and rock in rural area for installation of pump set with D.T.H. rig all complete! including supplying all materials, labours, tools, drilling rig, air compressor and equipment as well as fuel, lubricants for making boring and cost of transporting/charges of rig machine & other vehicles up to site of the work as per specification and direction of E/l. |
| 50 | Supplying materials and labours for construction of inspection chamber of designation class 75B brick size 750mm deco, 650x450mm internal dimension having 250mm all thickness in cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600x475mm G.I. cover with frame (weight not less than 36 kg.) along with earth work in excavation and refilling all complete as per specification and direction of E/I. |
| 51 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 52 | Stone Chips |
| 53 | Bricks |
| 54 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.GROUP C |
| 55 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 56 | 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 57 | 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire |
| 58 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 Way, Double Door |
| 59 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, \\"B\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.6/32 amps, Single Pole, \\"B\\" Series |
| 60 | 6/32 amps, SPN |
| 61 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 62 | Supplying and fixing batton/angle holder including connection etc. as required. |
| 63 | 5/6 amps, one way switch |
| 64 | 15/16 amps, one way switch |
| 65 | 3 pin 5/6 amp socket outlet |
| 66 | 6 pin 15/16 amp socket outlet |
| 67 | Supply of 48\\" (1200mm) Ceiling Fan |
| 68 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. |
| 69 | Supply of LED Street Light - 20 Watt |
| 70 | Supply of LED Bulb - 15/16 Watt |
| 71 | Fixing of copper/ G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 72 | Providing and fixing G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) |
| 73 | Reverting, sweating & soldering of copper / G.I. tape (with another copper/G.I. tape, base of the finial or any other metallic object) as required. |
| 74 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 75 | Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 76 | Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. |
| 77 | Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required. |
| 78 | Goods & Services Tax (G.S.T.) - 18% |
| 79 | Labour Cess - 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysOct 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender