Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57553490

Tender For Provision Of 82.5Kva And 180Kva Dg Sets Backup For Transit Facilities At Tf-I Tf-Iii, Major Quarter (Mq) & Tf-V At Cv Raman Nagar, Bangalore

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
39.70 Lakhs
Estimated cost
Bid Submission
02 Nov 2026
5 days left
EMD
79400
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of 82.5Kva And 180Kva Dg Sets Backup For Transit Facilities At Tf-I Tf-Iii, Major Quarter (Mq) & Tf-V At Cv Raman Nagar, Bangalore

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 24-Sep-2026 EMD Validity Fee 07-Oct-2026
2 08-Oct-2026 Extension of Bid submission date Date 14-Oct-2026
3 24-Sep-2026 EMD Validity Fee 14-Oct-2026
4 15-Oct-2026 Extension of Bid Submission Date 26-Oct-2026
5 13-Oct-2026 Corrigendum in NIT Clause Technical Bid 26-Oct-2026
6 24-Sep-2026 EMD Validity Fee 26-Oct-2026
7 13-Oct-2026 Corrigendum in NIT Clause Technical Bid 02-Nov-2026
8 24-Sep-2026 EMD Validity Fee 02-Nov-2026
9 27-Oct-2026 Extension of Date Date 02-Nov-2026

BOQ

Name of Work:- PROVISION OF 82.5KVA AND 180KVA DG SETS BACKUP FOR TRANSIT FACILITIES AT TF-I TF-III, MAJOR QUARTER (MQ) & TF-V AT CV RAMAN NAGAR, BANGALORE
Sl. No. Item Description
1DG SETS WITH CONNECTED ITEMS
2Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of 82.5 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine:Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 °C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.(B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level
3(C) Alternator:Synchronous alternator rated of 82.5 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK:Daily service fuel tank of OEM standard capacity, depending on the base frame design as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.(F) Exhaust System:Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.
4(I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, 82.5 KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. Reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( L- N & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator
515. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.Make: Kirloskar (KOEL Green) / Cummins (Sudhir / Jakson) / Kirloskar / Caterpillar model
6Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of 180 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine:Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 °C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level
7(C) Alternator:Synchronous alternator rated of 180 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
8(E) FUEL TANK:Daily service fuel tank of OEM standard capacity, depending on the base frame design as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.(F) Exhaust System:Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System:12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set. (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications. (I) AMF Panel:Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, 180 KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:
91. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. Reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( L- N & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic engine start/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning
1016. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories.17. Maintenance notification based on Engine Run Hour & due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.Make: Kirloskar (KOEL Green) / Cummins (Sudhir / Jakson) / Kirloskar / Caterpillar model
11LT CONTROL PANEL
12Supply, installation, testing and commissioning LT Control panel, Outdoor type, made out of 2.5 mm thick sheet steel duly powder coated, 500A aluminium busbar rating, CPRI approved, suitable MS channels for errection complete with voltmeter, ammeter, indicating lights, selector switch, incoming/ outgoing MCCBs current operated CTS of the following switch gear.Incomer:-1 No. 400 Amps MCCB, 4P, 36 KA, 415V, 50HZ as incomer.Outgoings-05 Nos, 125 Amps 4 Pole MCCB 25KA, 415V, 50HZ as outgoings.Make: i). Switch gear L&T / GEC / Siemens / ABB / Schneider. ii) LT panel shall be CPRI approved make
13EARTHING SYSTEM
14Earthing with copper earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc, with charcoal/ coke and salt as required.
15Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc, with charcoal/ coke and salt as required.
16Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm).
17Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm).
18LT CABLES AND END TERMINATION
19Supply and Testing of following size 1.1KV grade XLPE insulated armoured aluminium conductor cables. The cable shall conform to IS: 7098 Part 1/1988.Make : Finolex / KEI / RPG / CCI
203.5C X 240 Sq.mm A2XFY
213.5C X 150Sq.mm A2XFY
223.5C X95 Sq.mm A2XFY
23Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
24Above 35 Sq.mm. and up to 95 Sq.mm.
25Above 95 Sq.mm. and up to 185 Sq.mm.
26Above 185 Sq.mm. and up to 400 Sq.mm.
27Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
28Above 35 Sq.mm. and up to 95 Sq.mm.
29Above 95 Sq.mm. and up to 185 Sq.mm.
30Above 185 Sq.mm. and up to 400 Sq.mm.
31Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.Make : M-seal / Raychem / CCI
323.5 X 240 sq mm
333.5 X 150 sq mm
343.5 X 95 sq mm
35Providing of horizantal drilling for road crossing including supply and laying of HDPE pipe of 10 KG/Cm2 of 90mm dia. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57553490
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 39.70 Lakhs
LAST DATE 02-11-2026
Authority
Authority Name Defence Research And Development Organisation
Work Description Tender for Provision Of 82.5Kva And 180Kva Dg Sets Backup For Transit Facilities At Tf-I Tf-Iii, Major Quarter (Mq) & Tf-V At Cv Raman Nagar, Bangalore
Basic Detail
Tender No CCEESTS/ENQ/82.5 KVA/DG BLR/ 72/2026-27
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 13 Oct 2026
Submission Date 02 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 39.70 Lakhs
Tender Fee Ref. Documents
EMD 79400
Exemption Not Available
Document List
Annexure_II.pdf
Annexure_III.pdf
Annexure_II_III_V.pdf
Annexure_IV.pdf
Annexure_IV_NIT.pdf
Annexure_I_NIT.pdf
Annexure_VII.pdf
Annexure_VI_NIT.pdf
Annexure_V_NIT.pdf
Appendix_A.pdf
BGB_Proforma.pdf
BOQ_973603.xls
d9943d45-d72e-43f7-86a4-d3d34ddac546.html
GCC.pdf
GCC_2023.pdf
Special_Conditions.pdf
Tendernotice_1 (10).pdf
Tender_Enquiry.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 07, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 14, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 14, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 26, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 26, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 26, 2026
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 02, 2026
18:00 IST

Corrigendum-7 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Nov 02, 2026
18:00 IST

Corrigendum-8 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Nov 02, 2026
18:00 IST

Corrigendum-9 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Nov 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
pdf

Annexure_II.pdf

pdf

Annexure_III.pdf

pdf

Annexure_II_III_V.pdf

pdf

Annexure_IV.pdf

pdf

Annexure_IV_NIT.pdf

pdf

Annexure_I_NIT.pdf

pdf

Annexure_VII.pdf

pdf

Annexure_VI_NIT.pdf

pdf

Annexure_V_NIT.pdf

pdf

Appendix_A.pdf

pdf

BGB_Proforma.pdf

xls

BOQ_973603.xls

html

d9943d45-d72e-43f7-86a4-d3d34ddac546.html

pdf

GCC.pdf

pdf

GCC_2023.pdf

pdf

Special_Conditions.pdf

pdf

Tendernotice_1 (10).pdf

pdf

Tender_Enquiry.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender