Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #57553407

Tender For Special Repair Of Roof Leakage And Seepage Of Bldg No. P-77 In 2 Asd (23 Fad) At Mil Stn Beas Under Ge Kapurthala.

Issued by Statutory Bodies & Commissions/Committees · Kapurthala, Punjab
Tender Value
29.08 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
20 days left
EMD
58160
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kapurthala → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair Of Roof Leakage And Seepage Of Bldg No. P-77 In 2 Asd (23 Fad) At Mil Stn Beas Under Ge Kapurthala.

BOQ

Name of Work:- Special repair of roof leakage and seepage of Bldg No. P-77 in 2 ASD (23 FAD) at Mil Stn Beas under GE Kapurthala.
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Special repair of roof leakage and seepage of Bldg No. P-77 in 2 ASD (23 FAD) at Mil Stn Beas under GE Kapurthala. Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
2Dismantling of brick tiles or terracing tiles, single layer on roofs, complete all as specified and directed.
3Demolition of mud in roof , any thickness , including plastering and leeping (weather full thickness removed or a part thereof, complete all as specified and directed.
4M&L for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and directed.
5M&L for PCC padding 1:2:4, type B-1(using 20 mm graded crushed stone aggregate) of average thickness 50 mm to be provided in slope fixed with chicken wire mesh, complete all as specified and directed.
6Supply only integral water proofing compound
7M&L for 15mm thick screed bed or bedding layer of mortar in cement mortar 1:4, using WPC, complete all as specified and directed.Note:- WPC shall be measured and paid separately under respective item @ 200ml per bag of cement)
8M&L for APP modified roof treatment over existing accessible RCC roof slab/chajjah/canopy/ parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 litre/Sqm manufacture by the same agency as that of APP with a density of 0.87-0.89 Kg per litre at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.0 Kg/Sqm reinforced with non-woven polyster fiber of weight not less than 160 gsm/sqm using butane torch by torch application with 10 cm side laps and 15 cm end lap, complete all as specified and directed.
9M&L for 40mm thick brick tiles laid on 15mm screed bed in cement mortar 1:6 with jointing & pointing in cement mortar (1:3) mixed with 5% of crude oil by weight of cement all as directed.
10- ditto - all as per item No. 8 above but except bricks including cleaning of mortar from bricks etc; complete all as specified and directed.
11Cutting chases, pinning in brick walls making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exceeding 10 cm but not exceeding 20 cm girth, complete all as specified and directed.
12M&L for PCC 1:2:4 type B1 (20mm graded stone agg) as in coping incl necessary formwork etc; complete all as specified and directed.
13Taking down rain water pipes (any size and pattern) , including all fittings, ) complete all as specified and directed.
14S&F of PVC (SWR) pipes single socketed in any length with rubber ring joints fixed in trenches/floors/walls for 110mm bore of pipe fixed in repair complete all as specified and directed.
15S&F of PVC (SWR) floor bend, plain including jointing with solvent cement 110 mm bore in repairs, complete all as specified and directed.
16Demolition of brickwork/ stone masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
17M&L for brick work with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:4 complete all as specified and directed.
18- ditto - all as per item No. 16 above but except bricks including cleaning of mortar from bricks etc; complete all as specified and directed.
19Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
20M&L for rendering 15mm thick in cement mortar (1:4) on any of brick work or concrete surfaces of walls finished fair, complete all as specified and directed.
21M& L for preparation of newly plastered surface of walls and applying two coats of exterior emulsion paint in camoflouge pattern complete all as specified and directed.
22M&L for 5mm thick rendering in cement mortar 1:3 on brick work or concrete surfaces on ceiling finished even and smooth without using extra cement etc complete all as specified and directed.
23M&L for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and directed.
24M&L for preparation of old plastered ceiling surfaces and applying two coats of White Washing after preparation of complete surfaces complete all as specified and directed.
25M&L for preparation of old plastered surface of walls and applying two coats of exterior emulsion paint in camoflouge pattern complete all as specified and directed.
26M&L for rendering 15mm thick cement plaster in cement mortar (1:6) on any of brick work or concrete surfaces of walls finished even and smooth without using extra cement complete all as specified and as directed.
27M&L for preparation of newly plastered surfaces of walls and applying two coats of white wash complete all as specified and directed.
28M&L for preparation of old plastered surfaces of walls and applying two coats of white wash complete all as specified and directed.
29Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness below or above ground floors.
30Dismantling wrought iron or mild steel work of any description not otherwise provided for all as directed.
31S&F of rolled mild steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.quality confirming to Gde Fe 410-S complete all as specified and directed.
32S&F of MS bolt of dia 5 to 10 mm and length of bolt exc 5 cm and n.exc 10 cm (Machine made) with hexagonal or square head at one end and screwed other with washer out of shank .
33S&F mild steel plain sheet 1 mm thick as in steel gate and similar work cut to size, incl necessary holes punched, welding and fixed to steel framing joints incl bending or turning up, complete all as specified and directed.
34M&L for preparation of new or previously untreated steel surface and applying two coats of synthetic enamel paint over a coat of red oxide of surfaces exc 10cm width or girth, complete all as specified and directed.
35M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
36S&F in repairs aluminium strip of size 25 x 3 mm fixed to wall/ pole with aluminium saddles and screws for roof/ down conductor above ground/ buried in ground/ drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete with saddles / insulators at 50cm distance, all as specified and directed.Note : - Insulators/conduit/pipe shall be measured and paid separately under appropriate items here in after
37S&F in repair post insulator epoxy LV type suitable for copper/aluminium/ GI strip 25 x 3 mm lightening conductor fixed on wall/roof/pole including screw after taking down old one complete all as specified and directed.
38M&L for test point terminal block made of gun metal or phosphorus bronze of size 75x75x25mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws, complete all as specified and as directed.
39M&L for single pointed air termination copper rod , 12 mm dia , 300 mm long, complete all as specified and as directed.
40S&F in repair Junction box IP 65 with plain walls of size 167mm x 125mm x82mm made up of Polystyrene having shutter and lifting knob with provision of earth strip entry glands fixed to walls or pole with nuts, bolts, washers and testing complete all as specified and directed.
41M&L for galvanised iron tubing, medium grade, 40 mm bore, for lighting protection rod fixing on roof with plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate, complete all as specified and as Note:- PCC 1:2:4 shall be measured and paid seperately under respective item directed.
42M&L for prepration of new IDENTIFIER/ MARKER madeout of preferably metalic of size 30cm x 20cm x 2mm thick metalic board fixed on MS Angle 30 x 30 x 5 mm of 450 mm long to be fixed to ground by means of cement concrete including painting with two coats of synthetic enamel paint over a coat of red oxide primer and writting the earth resistance complete and coloured with following colour coading to identify.(a) For conventional/ Maintenance free earth pits- YELLOW colour.(b) Height of the identifier should be 60cm above the ground level all as directed.
43M&L for earthing complete with galvanized iron or steel or steel earth plate electrode of size 60cmx60cmx6.3mm thick buried directly in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI Strip of size 32x6 mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh GI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40mm graded stone aggregates complete including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in plate No 5 of SRR-1991 Part-1 . Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57553407
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 29.08 Lakhs
LAST DATE 08-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair Of Roof Leakage And Seepage Of Bldg No. P-77 In 2 Asd (23 Fad) At Mil Stn Beas Under Ge Kapurthala.
Basic Detail
Tender No 8209/E8
Bidding Type Tender
Location
City Kapurthala
State Punjab
Key Dates
Publish Date 17 Sep 2026
Submission Date 08 Oct 2026
Open Date 10 Oct 2026
Finance
Tender Value 29.08 Lakhs
Tender Fee 500
EMD 58160
Exemption Available
Document List
7b7a4cd4-407c-4b2f-a636-917c73aa12f7.html
BOQ_885255.xls
Tender.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

7b7a4cd4-407c-4b2f-a636-917c73aa12f7.html

xls

BOQ_885255.xls

pdf

Tender.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender