Tender For Repair/ Replacemaint Of Security Lights, Strret Light, Perimeter Lights,Highmast Lights, Solar Lights And Their Connected Items At Mp Golai & Burdong Under Ge Gangtok
Tender Value
18 Lakhs
Estimated cost
Bid Submission
07 Oct 2026
16 days left
EMD
36000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
sikkim → Sikkim
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacemaint Of Security Lights, Strret Light, Perimeter Lights,Highmast Lights, Solar Lights And Their Connected Items At Mp Golai & Burdong Under Ge Gangtok
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 M in wide and not exc. 1.5 M in depth for taking out or laying of under ground cable in soft / loose soil complete all as specified and as directed. |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick in soil complete all as specified and as directed. |
| 3 | Removing surplus soil to a distance not exceeding 50 M and deposited at a level not exceeding 1.5 M above the starting point complete all as specified and as directed. |
| 4 | M&L for plain cement concrete (1:3:6) type C-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 5 | M&L for GI pipe light grade with all fittings complete laid in ground all as specified for 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed. |
| 6 | S&F in repairs 200 Amp,4 pole, 25 KA thermal magnetic based, MCCB of 50Hz, 415 Volts, adjustable type including necessary cable lugs & wire etc complete all as specified and as directed. |
| 7 | All as per Sch 'A' Item No 6.00 herein above but 160 Amps, 4 pole, 25 KA thermal magnetic based |
| 8 | All as per Sch 'A' Item No 6.00 herein above but 100 Amps, 4 pole, 16 KA thermal magnetic based |
| 9 | All as per Sch 'A' Item No 6.00 herein above but 63 Amps, 4 pole, 16 KA, thermal magnetic based |
| 10 | Supply, laying, jointing and testing XLPE Cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor, 1100 Volt grade, cross sectional area 10 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed. |
| 11 | All as per Sch 'A' Item No 10.00 herein above but cross sectional area 10 sqmm 4 core |
| 12 | All as per Sch 'A' Item No 10.00 herein above but cross sectional area 16 sqmm 4 core |
| 13 | All as per Sch 'A' Item No 10.00 herein above but cross sectional area 35 sqmm 3.5 core |
| 14 | S&F in repairs post top lantern fitting of 40 Watts LED Stellar LED post-top offering comination of sturdy design, execllent illumination and aesthetics in one go, IP-66 and IK 10rating ensures it stands tall amid varid environemtal conditions with all accessories as required complete all as specified and as directed. |
| 15 | S&F in repairs 90 Watts,180 lumuns/watt with 10KV SPD LED Street light made up of pressure die cast housing with toughned glass, IP 66 protection and impact resistance of IK07 with secondary optics symmetrical light distribution and with all accessories as required complete all as specified and as directed. |
| 16 | S&F in repairs 60 Watts,120 lumuns/watt with 10KV SPD LED Street light made up of pressure die cast housing with toughned glass, IP 66 protection and impact resistance of IK07 with secondary optics symmetrical light distribution and with all accessories as required complete all as specified and as directed. |
| 17 | S&F in repairs 35/45 Watts, 70/90 lumuns/watt with 10KV SPD LED, Street light made up of pressure die cast aluminium housing with high efficiency LED lighting source and lens embeded PC cover, IP66 protection and impact resistance of IK08 with secondary optics symmetrical light distribution all accessories complete all as specified and as directed. |
| 18 | S&F in repairs 120/150W LED flood light of die-cast aluminium body, IP66 including all accessories as required complete all as specified and as directed. |
| 19 | S&F in repairs 210/250 W LED flood light of die-cast aluminium body, IP66 protection, heat resistant toughened clear glass cover with reflector and all accessories complete with all accessories as required complete all as specified and as directed. |
| 20 | S&F in repairs MCB, TPN, 63 Amps, 25 KA, 415 volts complete with connection, testing and commissioning complete all as specified and as directed. |
| 21 | S&F in repairs 20 mm dia rigid non metallic PVC Conduit inclusive of all tee, bends, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed. |
| 22 | M&L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) all as specified and as directed.Notes:-(a) The unit rates include staying the poles in a truly vertical position till the foundations are properly set.(b) Excavation, foundation concrete, presenative treatment, etc.will be measured separately under the appropriate sections. Painting to steel tubular poles (inside and outside) is however included in the rates of steel tubular poles.(c) The unit rates for poles shall also apply to struts when poles of the same size are used as struts.(d) The Unit Rates for steel tubular poles also include provision of finial and cast iron base plate fixed to poles.(e) The unit rates also include drilling of holes in steel tubular poles and hooks for continuous G.I. earth wire etc. to the required size and number.(f) The pipe incorporated for steel tubular poles shall be from the makes as indicated under Makes/manufacturer of GI Pipes). |
| 23 | S&F in repairs miniature circuit breaker (MCB) SP 6 to 32 Amps rating 240V, 10KA, 'C' curve complete with connection testing and commissioning complete all as specified and as directed. |
| 24 | Supply and laying DWC pipe, ISI marked laying in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket, bend, couplers etc confirming to IS 14930, part-II complete with fitting cutting, jointing etc of size 50 mm outer dia complete all as specified and directed. |
| 25 | M&L for cutting the existing road / PCC / drain for taking out / laying of underground cable including necessary earthwork excavation and making good to match with the exisitng surface with PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) complete all as specified and directed. |
| 26 | Taking up/down existing defective cable/ASCR conductor of any size 2/3/3.5/4 core from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station complete all as specified and as directed. |
| 27 | Relaying of old serviceable LT UG Cable of any size upto 50 Sqmm 3.5 core obtain from taking down under respective item here in above complete all as directed. |
| 28 | M&L for decorative type single arm street light bracket made out of mild steel medium grade MS pipe 100 mm / suitable size dia 0.40 mtr length suitable for fixing into top of the steel pole and mild steel medium grade 40 mm dia 1.40 mtr length and shape by cutting, welding and well fnishing with drilling hole, jionting of necessary 6 mm sheet metal corner support top cover and also inside the pipe and fixing with 12 mm dia 03 nos nuts & bolts duly welded at bottom parts for tighting bracket on pole including necessary painting with two coats aluminium paint over a coat of red oxide primer and necessary cutting hole of any size and shape compelete all specified and as directed.Note : Design and drawing of street light bracket may required to submit before fabrication for approval Engr-in-Charge. |
| 29 | S&F Street Light Timer with box consisting of Astronomical timer, Auto/Manual Swtich, Aluminium Bus bar, Power Contactor of suitable rating, MCB TPN 63 Amps for controlling mounted on pole, incl fixing arrangements complete all as specified and directed. Please Enable Macros to View BoQ information |
| 30 | S&F Street Light Timer with box consisting of Astronomical timer, Auto/Manual Swtich, Aluminium Bus bar, Power Contactor of suitable rating, MCB TPN 63 Amps for controlling mounted on pole, incl fixing arrangements complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender