Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #57553329

Tender For Civil Works For Creation Of Test Bed Facility At Hemrl, Pune

Issued by Statutory Bodies & Commissions/Committees · Pune, Maharashtra
Tender Value
99.80 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
11 days left
EMD
1.74 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Civil Works For Creation Of Test Bed Facility At Hemrl, Pune

BOQ

Name of Work:- CIVIL WORKS FOR CREATION OF TEST BED FACILITY AT HEMRL, PUNE
Sl. No. Item Description
1=B2& \\" BoQ\\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (R&D) SECUNDERABAD Name of Work: CIVIL WORKS FOR CREATION OF TEST BED FACILITY AT HEMRL, PUNE Contract No: CERD/PSN/TOKEN/30 OF 2026-2027 Bidder Name : PRICE SCHEDULE( This BOQ template must not be modified / replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SlNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Rate in Figures to be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes Total Amount Total Amount in Words
2Supply & erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-55 (11.00m long) and positioning in true vertical position complete including painting with black bituminous paint on the surface embedded and two coats of aluminium paint over one coat of red oxide primer on exposed surfaces of poles including marking of strip in alternate black and white paint pattern upto 2.0m above the pole coping and marking of pole number in yellow background circle 10cm radius and writing pole No. 3cm long using black colour complete all as specified and directed.
3Note: Excavation and earth work, returning and filling in, PCC 1:3:6 type C1 using 20mm graded stone aggregate in foundation and coping shall be deemed to be included in quoted rate.
4Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint at site complete all as specified and directed.
5S&F, light class G.I. pipe 100mm dia (nominal) 3 meters length along the pole for protection of underground cable as required complete all as specified and directed.
6Supply, install, test & commissioning of outdoor type, stepdown, copper wound transformer 800 KVA, 22KV / 0.433KV, BIS Level-II, onan cooled, oil immersed, conforming to specification EEL-2 of IS:1180-2014 Amendment Nos. 1, 2, 3 & 4, formerly EEL-03 (till 30 Mar 2022) complete with first filling of IS:335, ISI marked, filtered & dehydrated transformer oil and other standard fittings / accessories and offload tap changer complete all as specified and directed and comprising of the following accessories:-
7(a) HV Cable Box.(b) LV Cable Box (without cable gland).(c) Buchholz relay with Alarm and trip Contacts.(d) Oil temperature indicator with Alarm & Trip Contacts.(e) Winding Temperature Indicator with Alarm & Trip Contacts.(f) Marshlling Box (IP-55) having TTB only.(g) Top Cover lugs.
8(h) Transformer Drain Valve.(j) Bi-Directional plain Rollers.(k) Lifting Lugs.(l) Earthing Terminals.(m) Conservator with Oil Guage Glass, Oil filling Hole with plug and drain plug.(n) Transformer Drain Valve.(o) Explosion Vent with Diaphragm.(p) Thermometer Pocket.(q) Air Vent Plug.(r) Silica Gel Breather.(s) Rating and Diagram Plate inspection cover terminal.(t) Cooling Radiators.
9(u) LV Neutral Bushing brought out for external earthing.(v) First fill of EHV grade Transformer Oil as per IS 335.(w) Magnetic Oil level Gauge with Alarm and Trip Contacts.
10Supply, laying, testing & commissioning aluminium HT cable 22 KV, 3 core 95 Sq mm, Stranded Compacted Circular Aluminium Conductor, Conductor Screen with Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with Extruded Semi Conducting Compound in Combination with Copper Tape, Cores Laid Up, Inner sheath of PVC, Galvanised Steel Flat Strip Armoured & Overall PVC Sheathed Cable Conforming to IS 7098 (Part-2) 2011 with upto Date Amendments complete all as required complete all as specified and directed.
11Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for size 95 sq mm, 3 core, XLPE aluminium conductor cable of 22 KV grade as required complete all as specified and directed.
12Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for size 95 sq mm, 3 core, XLPE aluminium conductor cable of 22 KV grade as required complete all as specified and directed.
13Supplying and making straight through joint with heat shrinkable jointing kit complete with all accessories including lugs suitable for size 95 sq mm, 3 core, XLPE aluminium conductor cable of 22 KV grade as required complete all as specified and directed.
14Supply, install, testing & commissioning in replacement of 22 KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for vertical mounting complete with GI operating rod 32mm dia of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions for current rating upto 200 Amps, each pole consist of galvanised steel base HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magenetizing current of the transformers. All ferrous parts hot dipped galvanised and non ferrous parts heavily tinned to withstand weather including taking down old GOD complete all as specified and directed.
15S&F, lightning arrestor 18 KA station class including taking down old unserviceable LA set complete all as specified and directed.
16S&F in repair Polymer based dropout fuse unit complete set suitable and including for 22 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing, commissioning & dismantling of old DO fuse unit complete all as specified and directed.
17S&F, cable route marker with 10cm x 10cm x 5mm thick GI plate with inscription there on, bolted / welded to 35mm x 35mm x 6mm angle iron, 60cm long and fixing the same in ground as required complete all as specified and directed.
18Supply, fixing & commissioning of CPRI approved factory made LT cubicle panel board outdoor type conforming to IS/IEC-61439-1 & 2: 2011 with canopy, louvers & shutters made out of 3.15mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opening and lcoking arrangement, degree of protection IP 56, 415 volts, 3 phase, 4 wire, 50 Hz having aluminium bus bar of capacity 2400 Amps TPN duly colour coded and for neutral supported with DMC/SMC insulator colour coded
19with heat shrinkable sleeve having short circuit current with minimum 65 KA for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of CT's of metering, selector switches for voltmeter and ammeter, set of three LED type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels 75 x 75 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-
20Incoming:(a) Microprocessor based Air Circuit Breaker (ACB), manual draw out type 4 pole, 1600A, 415V, 65 KA, 50 Hz - 01 No.Outgoing:(a) MCCB 4P, 630A, 50 KA, 415V, AC supply including extended rotary handle and spreader terminals for incoming and outgoing - 01 No.(b) MCCB 4P, 400, 36 KA, 415V, AC supply including extended rotary handle and spreader terminals for incoming and outgoing - 02 Nos.(c) MCCB 4P, 315, 36 KA, 415V, AC supply including extended rotary handle and spreader terminals for incoming and outgoing - 02 Nos.
21(d) MCCB 4P, 100 Amps, 25 KA, 415V, AC supply including extended rotary handle and spreader terminals for incoming and outgoing - 02 Nos.(e) MCCB 4P, 63 Amps, 25 KA, 415V, AC supply including extended rotary handle and spreader terminals for incoming and outgoing - 02 Nos.(f) Panel mounted type digital multifunctional energy meter A, V, Z, KW, PF T operated, LT 3 Phase, 4 wire including CT ratio 100/5 - 04 Nos.(g) Control MCB 'C' curve, SP, 6 to 32A, 10KA, 'C' Curve - 04 Nos.(h) LED phase indicator (R, Y & B) - 01 Set.
22Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of HT/LT under ground cable and getting out in soft / loose soil of earth strata complete all as specified and directed.
23Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of HT/LT under ground cable and getting out in hard / dense soil of earth strata complete all as specified and directed.
24Supply & spread natural dry river sand for cable cushioning in trenches and punned down complete all as specified and directed.Note: Punned thickness will be measured for payment.
25Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
26Removing surplus excavated soil to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
27Supplying and laying un-reinforced precast concrete cable cover ISI marked, class HVP, type 2 with peak, size 300mm x 180mm x 40mm complete all as specified and directed.
28Supplying and laying un-reinforced precast concrete cable cover ISI marked, class HV, type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
29Supply, laying & testing, cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sqmm 3.5 core complete all as specified and directed.
30Supply, laying & testing, cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed.
31Supply, laying & testing, cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core complete all as specified and directed.
32S&F, MCCB 63 Amps 4 Pole 25 KA, 415 Volts in and including sheet metal enclosure with provision of grouting enclosure on wall by means of suitable bolts complete including connecting cables with glands complete all as specified and directed.
33M&L for earthing with galvanised steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to galvanised strip 25 x 5mm by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No. 03 of SSR Part I connected to earthing test point including excavation / earth work in any type of strata, removal of surplus excavated material, GI pipe for
34watering and funnel, PCC 1:3:6 type C1 chamber including necessary formwork / mould for fair and even surfaces, precast RCC 1:2:4 type B0 chamber cover slab, GI funnel with GI watering pipe 20mm bore medium grade, wire mesh, protection pipe 40mm bore GI pipe light grade for earth lead upto 7.50m long including testing complete all as specified and directed by Engineer-in-Charge.Note: Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE & PMG / user. Test results are to be written in letters of 20mm height in white colour on black paint back ground.
35S&F, 25mm x 5mm GI strip on surface or in recess for connections etc as required at site complete all as specified and directed.
36Providing and fixing H.T. danger notice plate of 250mm x 200mm, made of mild steel, at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required complete all as specified and directed.
37Supply and spreading at site 45 to 63mm hard angular free from dust and fine particles stone aggregate, minimum thickness not less than 120mm for outdoor Sub station complete all as specified and directed.
38M&L for cutting the existing GI pipe 150mm dia for inserting Tee 150 x 150 x 80mm complete all as specified and directed.
39Providing and fixing G.I. pipes medium grade of size 50mm dia nominal bore complete with G.I. fittings including trenching and refilling in any type of strata complete all as specified and directed.
40Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) for size 50mm dia complete all as specified and directed.
41Constructing masonry chamber 90 x 90 x 100cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 complete all as specified and directed.
42Clearing jungle including up rooting of rank vegetation, green bush wood trees and saplings of girth upto 30cm measured at a height of 1.0m above ground level and removal of rubbish / soil upto a distance of 1 Km outside the periphery of the area cleared complete all as specified and directed.
43Excavating holes more than 0.10 cum and upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, disposing of surplus excavated soil, as directed within a lead of 50m and lift upto 1.5m all kinds of soil complete all as specified and directed.
44Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level 1:2:4 [1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources] complete all as specified and directed.
45Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50m and lift upto 1.5m, all kinds of soil complete all as specified and directed.
46Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level 1:4:8 [1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40mm nominal size] complete all as specified and directed.
47Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 confirming to IS:2222 in superstructure above plinth level upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : 6.3.1 with F.P.S. (non modular) bricks complete all as specified and directed.
48M&L for rendering 12mm cement plaster of mix cement mortar 1:4 (1 cement : 4 fine sand) complete all as specified and directed.
49S&F, at site angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for 10cm length and drilling holes upto 10mm dia complete all as specified and directed.
50Finishing walls with acrylic smooth exterior paint of required shade : new work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
51Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50 x 50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required made of G.I. wire of dia 4mm complete all as specified and directed.
52Finishing with deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers specifications : painting steel work with deluxe multi surface paint to give an even shade, two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57553329
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 99.80 Lakhs
LAST DATE 14-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Civil Works For Creation Of Test Bed Facility At Hemrl, Pune
Basic Detail
Tender No 81413
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 16 Sep 2026
Submission Date 14 Oct 2026
Open Date 16 Oct 2026
Finance
Tender Value 99.80 Lakhs
Tender Fee 1000
EMD 1.74 Lakhs
Exemption Available
Document List
214a0cc9-190c-4047-b179-71e4e7587cc2.html
81413Tender.pdf
BOQ_885179.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

214a0cc9-190c-4047-b179-71e4e7587cc2.html

pdf

81413Tender.pdf

xls

BOQ_885179.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender