Defence Statutory Bodies & Commissions/Committees Closing in 6 days TDR #57553322

Tender For Repair/Maint Of Dg Set, Amf Panels And Other Connected Work Under Ge (Af) Adm Area At Af Stn Agra.

Issued by Statutory Bodies & Commissions/Committees · Agra, Uttar Pradesh
Tender Value
40 Lakhs
Estimated cost
Bid Submission
07 Oct 2026
6 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Dg Set, Amf Panels And Other Connected Work Under Ge (Af) Adm Area At Af Stn Agra.

BOQ

Name of Work:- REPAIR/MAINT OF DG SET, AMF PANELS AND OTHER CONNECTED WORK UNDER GE (AF) ADM AREA AT AF STN AGRA.
Sl. No. Item Description
1M&L for Servicing and checking of 25 KVA to 30 KVA DG Set including replacement of fuel filter (primary and secondary), supper by pass filter, separator fuel filter, oil filter of suitable size and checking of all safety devices including opening, adjusting, tightening of tappet cover complete by torque wrinch by applying proper pressure, cleaning of fuel and oil tank and refitting to DG set including replacement of new engine oil and coolant , complete cleaning of DG set examining and rectification of engine RPM, monitoring of output voltage and maintaining/adjusting speed governor, refilling the radiator with water and coolant, etc complete all as specified and directed Note :-1. Engine oil, coolant, safety device and spare parts required to replace shall be measured and paid separately ass supply only and under relevant item of BOQ items.(OEM: Kirloskar/Cummins/Jakson/Ashok Lyland/Existing make of DG set)2.The Repair /Overhauling work shall be carried out through authorized by OEM.
2All as per item No 1 above for 62.5 KVA DG set
3All as per item No 1 above for 82.5 KVA to 125 KVA DG set
4All as per item No 1 above for 200 KVA to 250 KVA DG set
5All as per item No 1 above for 320 KVA DG set
6Taking out radiator assembly from 320 KVA DG Set for cleaning by using wire brush, K/oil/Acid, compressed air & soldering/brazing where found leakage and re-fix in the same position and testing to the entire satisfaction of the Engineer-in-Charge complete all as specified and as directed.Note :- The Repair /Overhauling work shall be carried out through authorized by OEM.(OEM: Kirloskar/Cummins/Jakson/Ashok Lyland/Existing make of DG set).
7All as per item No. 6 above but 200 to 250 KVA DG Set.
8All as per item No. 6 above but 82.5 to 125 KVA DG Set.
9All as per item No. 6 above but 62.5 to 63 KVA DG Set.
10All as per item No. 6 above but 20 to 40 KVA DG Set.
11Taking out exhaust unit from 320 KVA DG Set for cleaning of silencer/RECD, silencer/ RECD pipe by using wire brush etc and re-fix in the same position with necessary welding nut and bolts complete all as specified and as directed. Note : The Repair /Overhauling work shall be carried out through authorized by OEM.(OEM: Kirloskar/Cummins/Jakson/Ashok Lyland/Existing make of DG set).
12All as per item No. 11 above but 200 to 250 KVA DG Set.
13All as per item No. 11 above but 82.5 to 115 KVA DG Set.
14All as per item No. 11 above but 62.5 to 63 KVA DG Set.
15All as per item No. 11 above but 20 to 40 KVA DG Set.
16Overhauling and calibration of injector & FIP pump complete in all respect all as specified as directed suitable for 320 KVA DG set Note : 1.The Repair /Overhauling work shall be carried out through authorized by OEM.(OEM: Kirloskar/Cummins/Jakson/Ashok Lyland/Existing make of DG set).
17All as per item No. 16 above but 200 to 250 KVA DG set.
18All as per item No. 16 above but 82.5 to 125 KVA DG set.
19All as per Item No. 16 but DG Set 20 to 63 KVA.
20M&L for Servicing and checking of RECD 320 KVA DG Set, all specified as directed.
21M&L for Servicing and checking of RECD 250 KVA DG Set, all specified as directed.
22M&L for maintenance of Canopy for DG set. Note: checking and servicing the acoustic enclosure to ensure proper cooling, noise reduction, weather protection and welding work as required.
23M&L for spray painting of AMF panel board with two coat of synthetic enamel high glow paint 1 st grade including preparation/cleaning of panel surfaces and welding work as required all as specified and directed by Engr in charge.
24Supply only Air filter element set complete, suitable for DG Set 320 KVA, all specified as directed.
25Supply only Air filter element set complete, suitable for DG Set 200 to 250 KVA, all specified as directed.
26Supply only Air filter , suitable for DG Set 82.5 to 125 KVA, all specified as directed.
27Supply only Air filter , suitable for DG Set 20 to 63 KVA, all specified as directed.
28Supply only (primary + secondary) fuel filter (set) complete in all respect, suitable for 320 KVA DG Set all as specified as directed.
29Supply only fuel filter complete in all respect ,suitable for 200 to 250 KVA DG Set all as specified as directed.
30Supply only (primary + secondary) fuel filter (set) complete in all respect ,suitable for 82.5 to 125 KVA DG Set all as specified as directed.
31Supply only (primary + secondary) fuel filter (set) complete in all respect ,suitable for 62.5 to 63 KVA DG Set all as specified as directed.
32Supply only (primary + secondary) fuel filter (set) complete in all respect ,suitable for 20 to 40 KVA DG Set all as specified as directed.
33Supply only Lub oil filter complete in all respect ,suitable for 320 KVA DG Set all as specified as directed.
34Supply only Lub oil filter complete in all respect ,suitable for 200 to 250KVA DG Set all as specified as directed.
35Supply only Lub oil filter complete in all respect suitable for 82.5 to 125 KVA DG Set all as specified as directed.
36Supply only Lub oil filter complete in all respect suitable for 62.5 to 63 KVA DG Set all as specified as directed.
37Supply only Lub oil filter complete in all respect suitable for 20 to 40 KVA DG Set all as specified as directed.
38S & F in replacement of radiator hose pipe complete with MS clamps, nuts and bolts for 320 KVA of DG Set complete all as specified and as directed. Note : 1.The Repair /Overhauling work shall be carried out through authorized by OEM.(OEM: Kirloskar/Cummins/Jakson/Ashok Lyland/Existing make of DG set).
39All as per Srl Item No 38 but 200 to 250 KVA of DG Set.
40All as per Srl Item No 38 but 82.5 to 125 KVA of DG Set.
41All as per Srl Item No 38 but 62.5 to 63 KVA of DG Set.
42S & F in replacement fuel flexible pipe set complete, suitable for DG Set 82.5 to 125 KVA.
43S & F in replacement of Fuel pipe complete in all respect all as specified as directed.
44Supply only of Engine oil 15 W / 40 complete all as specified and directed.
45Supply only of Distilled water for the batteries of the DG Sets complete all as specified and as directed.
46Supply only of Concentrate Coolant for DG sets all as directed.
47S & F in replacement unsv/defective water pump assy complete with DG set 200 to 250 KVA all as specified as directed.
48Supply and replacement Automatic voltage regulator (AvR) electronic type suitable for 82.5 to 125 KVA rating alternator complete all as specified and directed as per make recommended by existing OEM.
49M & L for repair of inlet & exhaust valve, valve guide & valve seat assembly making appropriate size complete in all respect suitable for 200 to 250 KVA DG Set complete all as specified and as directed.
50S & F in replacement V-Belts off size for 320 KVA DG Set (set of three), complete all as specified and as directed.Note : 1.The Repair /Overhauling work shall be carried out through authorized by OEM.(OEM: Kirloskar/Cummins/Jakson/Ashok Lyland/Existing make of DG set).
51All as per item No. 50 above but 200 to 250 KVA DG Set. (set of two).
52All as per item No. 50 above but 82.5 to 125 KVA DG Set.
53All as per item No. 50 above but 62.5 to 63 KVA DG Set.
54All as per item No. 50 above but 20 to 40 KVA DG Set.
55S & F in replacement radiator fan complete in all respect all as specified as directed suitable for 320 KVA DG set.Note : 1.The Repair /Overhauling work shall be carried out through authorized by OEM.(OEM: Kirloskar/Cummins/Jakson/Ashok Lyland/Existing make of DG set).
56All as per item No. 55 above but 200 to 250 KVA DG set
57All as per item No. 55 above but 82.5 to 125 KVA DG set
58Top overhauling / repairing of complete engine as dismantled with replacement of defective spare parts with new spare parts including minor repairs reassembling and testing all as specified and directed for 320 KVA DG SET. (Note:- New spare parts replaced under this item shall be measured and paid separately under schedule 'A'. The overhauling/repairing shall be carried out through authorized by OEM.(OEM:Jakson)
59Supply only of Piston for 320 KVA DG SET
60Supply only of Piston pin for 320 KVA DG SET
61Supply only of Liner Cylinder for 320 KVA DG SET
62Supply only of Piston ring set for 320 KVA DG SET
63Supply only of Connecting rod bearing for 320 KVA DG SET
64Supply only of Valve Inlet for 320 KVA DG SET
65Supply only of Exhaust valve for 320 KVA DG SET
66Supply only of Seat Inlet valve for 320 KVA DG SET
67Supply only of Seat Exhaust valve for 320 KVA DG SET
68Supply only of Rod Push for 320 KVA DG SET
69Supply only of Seal Valve Steam for 320 KVA DG SET
70Supply only of Complete HEAD Gasket with packing for 320 KVA DG SET
71Supply only of Set of Joints for 320 KVA DG SET
72Supply only of Valve Guide for 320 KVA DG SET
73Supply & fixing of fully automatic battery charger input 230V AC and out put 24V DC, 10 Amp, for 24 Volt battery complete all as specified and directed.
74Supply & fixing of fully automatic battery charger input 230V AC and out put 12V DC,6 Amp for 12Volt battery complete all as specified and directed.
75S & F in replacement battery 12V, 180 AH with Electro plates including battery lead positive & negative battery terminals and initial charging of battery etc incl making connection with self starter complete all as specified and as directed.
76S & F in replacement battery 12V, 150 AH with Electro plates including battery lead positive & negative battery terminals and initial charging of battery etc incl making connection with self starter complete all as specified and as directed.
77S & F in replacement battery 12V, 65/100 AH with Electro plates including battery lead positive & negative battery terminals and initial charging of battery etc incl making connection with self starter complete all as specified and as directed.
78Checking of AMF panel / DG set for detecting any kind of fault in AMF panel/DG set and attending the fault immediately at any time round the clock and carry out certain repair required at per site requirement and checking of AMF panel and DG set for power supply from DG set through AMF panel and replacing of worn out parts of AMF panel/DG set by expert engineer complete all as specified and directed. Note:(a) Unit rate of this item includes \\"detecting of any kind of fault in AMF panel/DG set\\" only and cost of replacement of worn out parts of AMF panel/DG set shall be measured and paid separately under items of schedule 'A'.(b). The Repair /Overhauling work shall be carried out through authorized by OEM.(OEM: Kirloskar/Cummins/Jakson/Ashok Lyland/Existing make of DG set)
79S & F in replacement of copper battery lead of 16 sqmm, 2mtr long and including battery terminals suitable for all capacities of dg sets complete all as specified and as directed.
80S&F in replacement ON-LOAD Change over switch (Open Execution, Front operated) of 250 Amps, 4 pole, 415V, 50Hz complete all as specified and directed.
81All as per item No 80 above but for 400 Amp.
82All as per item No 80 above but for 630 Amp.
83S&F in replacement OFF-LOAD Change over switch (Open Execution, Front operated) of 100 Amps, 4 pole, 415V, 50Hz complete all as specified and directed.
84S&F in replacement OFF-LOAD Change over switch (Open Execution, Front operated) of 63 Amps, 4 pole, 415V, 50Hz complete all as specified and directed.
85S&F in replacement of internal wiring dg set/ control panel and AMF panels with existing size of copper cable up to 125 KVA DG set complete all as specified and directed.
86S&F in replacement of internal wiring dg set/ control panel and AMF panels with existing size of copper cable 200 to 320 KVA DG set complete all as specified and directed.
87Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line, and getting out complete all as specified and directed
88Returning & filling including spreading, levelling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and directed.
89Removal of excavated soil to a distance n. exc 50 m above the starting point complete all as specified.
90Supply and Laying of 95 Sqmm 3.5 Core LT XLPE UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of following sizes core in trenches or fixed on wall/floor/ pole complete all as spd and directed.
91Supply and Laying of 70 Sqmm 3.5 Core LT XLPE UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of following sizes core in trenches or fixed on wall/floor/ pole complete all as spd and directed.
92Supply and Laying of 50 Sqmm 3.5 Core LT XLPE UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of following sizes core in trenches or fixed on wall/floor/ pole complete all as spd and directed.
93Taking out old unserviceable LT UG cables of size 10 to 120 Sq mm 3.5/4 Core from trenches, poles/walls and floor for removing of fault or re-laying (Necessary earth work shall be measured and paid under respective item of sch.) complete all as specified and directed.
94Supply, fixing and laying double wall corrugated (DWC)HDPE Full Rounded pipe in 6 Mtrs Length conforming to IS 16205Pt-24 of approved colour complete with fittings for cable protection of Size in 110mm Outer Dia 95mm Inner Dia complete all as specified and directed.
95Supply, fixing and laying double wall corrugated (DWC)HDPE Full Rounded pipe in 6 Mtrs Length conforming to IS 16205Pt-24 of approved colour complete with fittings for cable protection of Size in 75mm Outer Dia 63 mm Inner Dia complete all as specified and directed.
96Supply, fixing and laying double wall corrugated (DWC)HDPE Full Rounded pipe in 6 Mtrs Length conforming to IS 16205Pt-24 of approved colour complete with fittings for cable protection of Size in 63mm Outer Dia 50 mm Inner Dia complete all as specified and directed. Please Enable Macros to View BoQ information
97Supply, fixing and laying double wall corrugated (DWC)HDPE Full Rounded pipe in 6 Mtrs Length conforming to IS 16205Pt-24 of approved colour complete with fittings for cable protection of Size in 63mm Outer Dia 50 mm Inner Dia complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57553322
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 07-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Dg Set, Amf Panels And Other Connected Work Under Ge (Af) Adm Area At Af Stn Agra.
Basic Detail
Tender No 8000-2393/E8
Bidding Type Tender
Location
City Agra
State Uttar Pradesh
Key Dates
Publish Date 16 Sep 2026
Submission Date 07 Oct 2026
Open Date 09 Oct 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Not Available
Document List
b64e8054-d8c8-4232-87a8-27a4b74c85a1.html
BOQ_885234.xls
Tendernotice_1 (10).pdf
TenderT34.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

b64e8054-d8c8-4232-87a8-27a4b74c85a1.html

xls

BOQ_885234.xls

pdf

Tendernotice_1 (10).pdf

pdf

TenderT34.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender