Tender For Provn Of 01 X Parking Garrage For Heavy Recovery Veh At Mechanical Transport Area Of 282(I) Fd Wksp Coy Eme And Training Store At Klp Location Of 154 Infantry Battalion (Territorial Army) Bihar, Brichgunj Mil Stn, Sri Vijaya Puram.
Tender Overview
Project Description
Tender for Provn Of 01 X Parking Garrage For Heavy Recovery Veh At Mechanical Transport Area Of 282(I) Fd Wksp Coy Eme And Training Store At Klp Location Of 154 Infantry Battalion (Territorial Army) Bihar, Brichgunj Mil Stn, Sri Vijaya Puram.
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches for hard/dense soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed |
| 2 | M&L for Plain Cement concrete 1:4:8, type D2, (using 40mm graded stone aggregate) as in foundations, filling and mass concrete etc complete all as specified and as directed. |
| 3 | M&L for Reinforced cement concrete (Design mix M-30 grade) (using 20mm graded stone aggregate) as in foundations footings, plinth beams, bases for columns, etc and mass concrete complete all as specified and as directed. |
| 4 | M&L for Reinforced cement concrete (Design mix M-30 grade) (using 20mm graded stone aggregate) as in above top of footings including attached pilasters and buttresses complete all as specified and as directed. |
| 5 | M&L for Reinforced cement concrete (Design mix M-30 grade) (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed. |
| 6 | M&L for Reinforced cement concrete (Design mix M-30 grade) (using 20mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 7 | M&L for Reinforced cement concrete (Design mix M-30 grade) (using 20mm graded stone aggregate) as in slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in,shelves and the like complete all as specified and as directed. |
| 8 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 9 | Removing excavated soils to a distance n.exc 50M and depositing where directed at a level n.exc 1.5M above the starting point complete all as specified and as directed. |
| 10 | M&L for Use and waste of formwork flat or curved to sides of concrete foundations, footings, bases of columns, and plinth beams and similar work vertical or to batter complete all as specified and as directed. |
| 11 | M&L for Use and waste of formwork flat or curved to to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed. |
| 12 | M&L for Use and waste of formwork flat or curved to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvesincluding sup- ports, overhangs, etc. also splays between floors and beams, with fair finished etc, complete all as specified and as directed. |
| 13 | M&L for Use and waste of form work to sides and sofit of Slab & Chajja etc for fair finished surfaces complete all as specified and as directed.. |
| 14 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 15 | M&L for TMT bars 6mm to 8mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 16 | All as per Item Ser No.15.00 but 5mm dia and over up to and including 10mm dia as in stirrups, spacers, binders and the like, complete all as specified and as directed. |
| 17 | M & L for Precast cement concrete block masonry 1:3:6, type C1, (20mm graded stone aggregate) as in masonry with solid block exc10cm in width and setting in CM 1:6 etc complete all as specified and as directed. |
| 18 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6, finished even and smooth without using extra cement complete all as specified and as directed. |
| 19 | M&L for Rendering 15mm thick in two layers of 10mm thick backing coat in CM 1:6 and 5mm thick floating coat in CM 1:4 mixed with water proofing compound on all external wall surfaces finished even and smooth without using extra cement complete all as specified and as directed. (Note : Water proofing compound shall be measured and paid seperately) |
| 20 | Supply only water proofing compound (Powder) conforming to IS-2645 1975 complete all as specified and as directed. |
| 21 | M&L for Preparation of newly plastered / untreated surface of wall and applying two coats of Oil Bound distemper over a coat of primer complete all as specified and as directed. |
| 22 | M&L for Preparation of newly plastered / untreated surface of wall and finishing walls with Acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and as directed.(Make Apex Ultima) |
| 23 | Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting out in Hard/dense soil, complete all as specified and as directed. |
| 24 | M&L for Hard core 150mm thick of guage n.exc.63mm using broken stone aggregate spread, levelled, watered and rammed to a true surface complete all as specified and as directed. |
| 25 | M&L for Plain cement concrete 1:3:6, type C1, 75 mm thick (using 20 mm graded stone aggregate) as in plinth protection/Sub base flooring, finishing surface fair and even, in panels & filling joints with mortar, etc., complete all as specified and directed. |
| 26 | M&L for Plain cement concrete 1:3:6, type C1, 100 mm thick (using 20 mm graded stone aggregate) as in sub base, sub floors & floors, finishing surface fair and even, in panels & filling joints with mortar, etc., complete all as specified and directed. |
| 27 | M&L for Coloured machine pressed precast concrete interlocking paver block, 80mm thick, glossy finished any size and shape conforming to IS 15658-2006 , M-40 Grade with grey cement and pigment over sand filling complete all as specified and as directed.( Cost of Sand will be measured and paid separately) |
| 28 | M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 29 | S & F Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 30 | S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all as per architectural drawings, complete all as specified and as directed. |
| 31 | Supply only 4mm thick sheet glass ordinary quality and glazing with rubber packing around the glass, in squares n. exc 0.5 Sqm in each pane complete all as specified and as directed. |
| 32 | S & F Plates (Plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes with attachment etc and fixed by riveting or welding or with nut and bolts (including nut and bolts) conforming to Fe- 410-W Grade E- 250, quality B, complete all as specified and as directed. |
| 33 | M & L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.con- forming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 34 | M&L for Mild steel bolts of diameter of neck exc 12mm and n.exc 20mm, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut n exc 30cm long complete all as specified and as directed. |
| 35 | M&L for Preparation of new or previously untreated steel surfaces and applying a two coats of synthetic enamel paint over a coat of red oxide primer over 10cm in width or girth, not otherwise described complete all as specified and as directed. |
| 36 | M&L for prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering, fixed with self tapping screws or L'or 'J' type hook, complete all as specified and as directed. |
| 37 | M&L for Prepainted galvalume aluminium zinc coating GI based plain sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in ridges, valleys hips etc fixed with self tapping screws or L'or 'J' type hook , complete all as specified and as directed. |
| 38 | M&L for Mild steel work in wind ties for roof/ valley gutter frame including securing bolts etc complete all as specified and as directed. |
| 39 | M&L for Rendering 5mm thick in cement mortar 1:3 on soffits of RCC slabs, roof projections, soffits and sides of RCC beams, waist slab, Loft Slab, RCC shelves, Chajjas, and the like finished even and smooth without using extra cement complete all as specified and as directed. |
| 40 | M&L for Preparation of newly plastered surface or unplastered surfaces of walls, cornices etc and applying two coats of Oil Bound distemper over a coat of primer over and a coat of 1mm thick wall care putty etc complete all as specified and as directed. |
| 41 | M&L for Preparation of newly plastered surface or unplastered surfaces of ceiling etc and applying two coats of Oil Bound distemper over a coat of primer over and a coat of 1mm thick wall care putty etc complete all as specified and as directed. |
| 42 | M&L for Plain cement concrete 1:4:8, 75mm thick, type D2 (using 20mm graded stone aggregate) as in sub base of flooring/hard standing,Path way complete all as specified and as directed. |
| 43 | M&L for Plain cement concrete 1:2:4, type B-1, 40mm thick (using 20 mm graded stone aggregate) as in floor finishes etc complete all as specified and as directed. |
| 44 | M&L for Coloured Non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.18 sqm and n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry in floors and pointed with coloured cement to match the colour of tiles incl screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed. |
| 45 | All as per Item Ser No.44.00 but in skirting over 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed |
| 46 | S&F Prelaminated particle board, 12 mm thick , exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination and fixed to aluminium frames complete all as specified and as directed. |
| 47 | S&F Aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) 300 mm long and fixing clips to sheet cast or extruded sections and fixing bolt or cast aluminium alloy complete all as specified and as directed. |
| 48 | S&F Aluminium anodised barrel tower bolt of extruded section of size 150mm long complete all as specified and as directed. |
| 49 | S&F 150mm long extruded aluminium alloy anodised handles fabricated type complete all as specified and as directed. |
| 50 | S&F Plain, Aluminium sheeting, 0.56mm thick Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) fixed with self tapping screws as specified complete all as specified and as directed. |
| 51 | M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 52 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed. |
| 53 | M&L for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified and directed. |
| 54 | S&F PVC insulation panels, 10 mm thick with EPS stuck to 1mm printed PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification and drawing complete all as specified and as directed. |
| 55 | M & L for Point wiring complete with single core multi stranded Copper conductor FRLS cable of size 1.5 sqmm PVC insulated unsheathed 1100 volt grade in and including PVC conduit suitable size including Tee junction bends etc concealed in wall/fixed on ceiling and PVC switch board hylam sheet of 3mm thick including M.S. sunken boards of suitable size for housing switched sockets etc including 1.5 sqmm. green PVC insulated wire for earth continuty.complete all as specified and as directed. (a) One light point controlled by one way switch |
| 56 | (b) One three pin 5 Amp switch socket cum on same board |
| 57 | (c) One 3 pin switch socket outlet point 5 amps on independent board |
| 58 | All as per Item Ser No.55.00 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed. |
| 59 | M&L for Point wiring complete with 1.5 sqmm single core FRLS PVC insulated and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing and caping and all accessories fixed to walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable green in colour as earth continuity conductor and connected to common earth dolly, including fabricated steel terminal box made out of 1.60mm thick MS sheet concealed in walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets,fan regulators etc., complete all as specified and as directed for the following: (a) One light point controlled by one switch |
| 60 | (b) One fan point controlled by one switch and one regulator |
| 61 | (c) One 3 pin switch socket outlet point 5 amps on independent board |
| 62 | All as per Item Ser No.59.00 here-in-before but for 3 pin 15 Amps switch socket combination on independent board with 4 sq mm copper cable and provision of 4 sq mm FRLS PVC insulated stranded copper conductor cable for earth continuity conductor connected to common earth dolly connecting upto fittings complete all as specified and as directed. |
| 63 | S&F Switch piano flush type single pole one way 5 Amp complete all as specified and as directed. |
| 64 | S&F Switch socket combination 2 in 1, 5 Amps, 5 pin multipurpose, flush type, 230 Volts complete all as specified and as directed. |
| 65 | S&F Switch socket outlet multipurpose 3 pin 15 and 5 amp controlled by one switch, flush type complete all as specified and as directed. |
| 66 | S&F Ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specfified and as directed. |
| 67 | S&F Fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed. |
| 68 | S&F Aluminium housing LED batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose complete all as specified and as diected. |
| 69 | S&F Street light pressure dia cast aluminium IP65 road way luminaire with high power LEDs 35 w as light and electronic driver complete all as per with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete all as specified and as directed. |
| 70 | S&F Exhaust fan steel body suitable for on working of AC 230 V ,50 Hz 300 mm sweep upto 1400 RPM,with heavy duty motor ,incl louvers complete all as specified and as directed. |
| 71 | S&F Ceiling fan suitable for working on AC 230 volts, 50 Hz,1200 mm sweep 5 star rating with down rod and canopy colour of milky white including suitable fan hook anchor fastner for fixing of fan on ceiling complete all as specified and as directed. |
| 72 | S&F Metal enclosure distribution board SPN, 8 way 240 volts, with 100 amps rated bus bar, with IP 43 protection and double door, suitable for mounting MCBs complete all as as specified and as directed. |
| 73 | S&F MCB single pole, 240 volts, 5 to 32 Amps, complete all as specified and as directed. |
| 74 | S&F MCB SPN 240 volts, 5 to 32 Amps, complete all as specified and as directed. |
| 75 | M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC 1:3:6, type C1, Pre cast RCC 1:2:4, type B1, cover slab 54cm x 54cm x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including earth work excavation complete all as specified and as directed electrical plate No. 3 of SSR part - I |
| 76 | Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with aluminium stranded conductor 1100 volt grade of cross section area 2 Core 10 sq mm complete all as specified and as directed. |
| 77 | Supply & laying cable protection pipe of HDPE double wall corrugated (DWC) incl couplers,bends etc of size 50 mm OD and ID 38mm confirming to IS 14930 -II and ISI Marked complete all specified and as directed. |
| 78 | S&F Galvanised iron (GI) tube light grade 50mm bore with all fittings laid in trenches complete all as specified and as directed. |
| 79 | M&L for cutting bituminous road at a width not more than 30cm and a depth not exceeding 60 cm for laying of pipes on road crossing for cable protection and making good with cement concrete 1:2:4, type B-2, to match with the existing surfaces of the road complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender