Tender For Construction Of Additional Accommodation Building (G+2)(02Nos 2 Bhk Units,Doctors Room , Barrack And Stilt Parking) At Wazarat Road. Cno- 256 P
Tender Value
2.24 Crore
Estimated cost
Bid Submission
30 Sep 2026
10 days left
EMD
4.49 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Additional Accommodation Building (G+2)(02Nos 2 Bhk Units,Doctors Room , Barrack And Stilt Parking) At Wazarat Road. Cno- 256 P
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : FC1, FC1,FC2, FC7, FC8, FC14, CF1, CF2, CF3 |
| 2 | Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil : FC1, FC1,FC2, FC7, FC8, FC14, CF1, CF2, CF3 |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, lead upto 50Mt & lift upto 1.50M. |
| 4 | Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 7 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 8 | 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 9 | CAST-IN-SITUProviding and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with . 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete work in arches, archribs, domes, vaults shells, folded plate and roofs having slope more than 15° upto floor five level level including curing but excluding the cost of centering, shuttering finishing and reinforcementwith: 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 13 | Providing, hoisting and fixing up to floor five level precast reinforced cement concrete inshelves including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of requiredcentering, shuttering and finishing with neat cement punning on exposed surfaces andcuring but excluding the cost of reinforcement with:1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 14 | Steel Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form work for :- Foundations, footings, bases of columns etc. for mass concrete |
| 16 | Columns, Pillar, Pier, abutments, posts and struts |
| 17 | Lintel, beams, plinth beams, girders, bressumers and cantilevers |
| 18 | Suspended floors, roofs, landings, balconies and access platforms |
| 19 | Edges of slabs and breaks in floors and walls |
| 20 | Stairs (excluding landings) except spiral staircases. |
| 21 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 22 | Extra for brick work in super structure above plinth level upto floor V-level. |
| 23 | Half brick masonry with common burnt clay (non-modular) bricks of classdesignation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 24 | Extra for half Brick masonry in superstructure above plinth level upto floor V level. |
| 25 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every thirdcourse of half brick masonry. |
| 26 | CERAMIC GLAZED TILES Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 27 | Frames and trusses Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dashfasteners shall be paid for separately): SAL WOOD |
| 28 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws - 35 MM THICK |
| 29 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured) |
| 30 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 31 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer allcomplete. Fixed to openings / wooden frames with rawl plugs screws etc. |
| 32 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 33 | Providing and fixing bright finished brass door latch with necessary screws etc. complete. : 300x16x5 mm |
| 34 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. 250x10 mm |
| 35 | Providing and fixing bright finished brass handles with screws etc. complete : 125 mm. 2 handles per shutter DOORS |
| 36 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Twin rubber stopper |
| 37 | Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto1.75 sqm) |
| 38 | Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) |
| 39 | Cost for 6 mm thick clear heat strengthened glass |
| 40 | Cost of Galavanised wire mesh of average width of aperture 1.4 mm andnominal dia. of wire 0.63 mm |
| 41 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and boltedwith special shaped washers etc. complete. Electric resistance or induction butt welded tubes |
| 42 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 43 | Providing and fixing hand rail of approved size by welding etc. to steel Ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 44 | VITRIFIED FLOOR TILESProviding and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching Pigments etc. complete. Size of tile 600x600 mm |
| 45 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shades, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints. Size of tile 600x600 mm |
| 46 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 47 | Stone tile work for wall lining upto 10m height with special adhesive like araldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade. 8mm thick (mirror polished and machine cut edges), Granite stone of any colour and shade |
| 48 | Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 49 | Providing and fixing tiled False Ceiling of specified materials of size 595x595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main “T” runner with suitably spaced jointsto get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x 600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in thegrid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (The rate is excluding the cost of tiles which will be paid for separately).8 mm thick fully perforated Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/cm2, bending strength 100 kg/cm2, of size 595x595 mm, having perforation of dia. 10mm with minimum perforated area 18% with non-woven tissue on the back side, having an NRC (Noise Reduction Certificate) of 0.85, with 50 mm thick rock wool of 48 kg/cum backing. |
| 50 | CEMENT PLASTER (IN FINE SAND)12mm Cement plaster of mix: 1:6 (1 cement : 6 fine sand) |
| 51 | 15mm cement plaster on the rough side of single or half brick wall of mix in 1:6 (1 cement : 6 fine sand). |
| 52 | Extra for plastering exterior walls of the height more than 10m fromground level for every additional height of 3m or part thereof. |
| 53 | 6MM CEMENT PLASTER6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) |
| 54 | Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: Painting wood work with deluxe multi surface paint of required shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @0.75litre/10sqm of approved brand and manufacture. Sal wood |
| 55 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2mm thick |
| 56 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/liter |
| 57 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieveeven shade and colour. Two coats |
| 58 | EXTERIOR FINISHINGFinishing wall with premium acrylic smooth exterior paint with silicone additives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) |
| 59 | Painting with synthetic enamel paint of approved brand and manufacture to givean even shade. Two or more coats on new work |
| 60 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 61 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 62 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: in mortar cement |
| 63 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : |
| 64 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approvedcolor design and pattern. |
| 65 | Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of:(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.(ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. Per sqm of area.(iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints ofPVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 66 | Providing and fixing Inaguration stone of granite(size 3'0\\"x2'0\\") incl. engraving writing and fixing in wall including Construction of Pedestal Complete Job) : |
| 67 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs)c) After two days of proper curing applying a second coat of cement slurry using2.75kg/sqm of cement admixed with water proofingcompound conforming to IS 2645 and approved by Engineer-in-charge.d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineer in-charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm |
| 68 | Architectural/ MEP and structural design of all the components. Structural design duly vetted by any NIT / IIT before execution of work, inclusive of soil testing by means of SPT and vetting charges. The architect consultant should be based in J&K for ease of communication and shall be approved by concern AEE and authenticated by Execetive Engineer before hiring. |
| 69 | By Mechanical Transport including loading, unloading and stacking. Sand, stone aggregate below 40 mm nominal size |
| 70 | Stone Aggregate. stone 40 below aggregate - 12 km by MT |
| 71 | Stone Aggregate. stone 40 above -12 km by MT |
| 72 | Bricks |
| 73 | mulba |
| 74 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 75 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 76 | Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels 8.2.1 Raj Nagar plain white marble/Udaipur green marble/zebra black marble8.2.2 Granite of any colour or shade 8.2.2.1 (Area of slab upto 0.5 sqm) (18mm thickness) |
| 77 | Providing double edge moulding to granite stone including machine polishing to edge to give high gloss finish etc. complete as per design as approved by Engineer-in-charge. |
| 78 | Providing, fixing and applying Plaster of Paris (POP) false ceiling consisting of frame work made with 50mm sq M.S. tubes of 18 G thickness as main runner at 600 mm c/c both ways, suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab, finished smooth to line and level including necessary supports, scaffolding etc. as requiredand also including applying a coat of red oxide zinc chromate primer over the M.S. frame work and suspenders complete.12.47.1 Including providing and fixing expanded metal of size 5.25 mm x 1.25 mm thickness welded to main runners and applying POP (calcium sulphate semi hydrate variety) to the expanded metal of thickness not less than 10 mm |
| 79 | Providing and fixing of 19 mm ply including necessary fittings, fixtures of approved quality and make |
| 80 | Providing and fixing stainless steel (Grade 304) railing made of Hollowtubes channels, plates etc. including welding ,grinding, buffing, polishingand making curvature (wherever required) and fitting the same withnecessary stainless steel nuts and bolts complete ,including fixing the railingwith necessary accessories and stainless steel dash fasteners, stainless steelbolts etc. of required size, on the top of the floor or the side of waist slabwith suitable arrangement as per approval of Engineer-in-charge, (forpayment purpose only weight of stainless steel members shall be consideredexcluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 81 | Providing and fixing 5 to 6mm thick PVC panelling heavy duty of approved quality and make |
| 82 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 83 | Providing and fixing ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours shade except burgundy, bottle green black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. : Size of tile : 300 x 600mm |
| 84 | Providing and laying vitrified full body floor tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints, with white cement and matching pigments etc. complete : Size of tile : 600 x 1200mm |
| 85 | Providing and fixing of 6mm thick ply of approved quality and make including necessary fittings, fixtures etc. complete |
| 86 | CNC Cutting of plywood of 6mm and 19mm thick ply includingcarriage, cutting, wastage and fixing complete. |
| 87 | Providing and installation of V-Groove rubber tiles (glued down by adhesive) 25mm thick of size 500x500mm made up of SBR recycled rubber crumb, polymerically bonded(Hot Molded Technology) with crumb rubber granules ranging from 1mm to 2mm (tensile strength of 1.5Mpa, Elongation at tear of 120%, density of G80 Kg/cum, Specific Gravity of 0.G8g/cum, compression set (%) of 0.G6, shore hardness 55+/-5 shore A, Abrasion Resistance 0.7% by weight complying to IS:3400,IS:1237,ASTM D 7G2, 170G, 2240, STRC/STP/BM02) ofapproved color, size, brand and make including carriage, wastage complete as per the direction of engineer-in charge. |
| 88 | Providing and fixing of flush door shutters of approved make fixed with 1mm thick mica on both side complete including fittings etc. complete |
| 89 | Providing and fixing on wall face un-plasticized Rigid PVC rain waterpipes conforming to IS: 135G2 Type A including jointing with seal ringconforming to IS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes12.58.2 110 mm diametre |
| 90 | Site clearance after completion of work by engaging labour |
| 91 | Dismantaling of existing Steel shed at proposed new construction including stacking of the material and disposal upto 50 metre |
| 92 | Providing and fixing of WPC louvers inc. all fitings and fixtures complete |
| 93 | P/F OF 8MM THICK LAMINATED WOODEN FLOORING (PLASTIC COATED) OF APPROVED MAKE INCLUSIVE OF ALL CARRIAGES WASTAGE COMPLETE JOB |
| 94 | Engaging welder for carrying out welding works including welding set with electrodes etc. complete. |
| 95 | UNDER GROUND WATER TANK AND SEPTIC TANK. Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : UG WATER tank, UG SEPTIC TANK |
| 96 | Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stackedmaterials. All kinds of soil : UG WATER tank, UG SEPTIC TANK |
| 97 | 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 98 | 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 99 | CAST-IN-SITUProviding and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 100 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 101 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 102 | Steel Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete UPTO PLINTH LEVEL. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 103 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in positionand binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 104 | Centering and shuttering including strutting, propping etc. and removal of form work for :- Foundations, footings, bases of columns etc. for mass concrete |
| 105 | Walls (any thickness) including attached pilasters, buttresses, plinth andstring courses etc. |
| 106 | Suspended florrs, roofs, landings, balconies and access platforms |
| 107 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 108 | Half brick masonryHalf brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement : 3 coarse sand) |
| 109 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of halfbrick masonry. |
| 110 | CEMENT PLASTER (IN FINE SAND)12mm Cement plaster of mix: 1:6 (1 cement : 6 fine sand) |
| 111 | Sand, stone aggregate below 40 mm nominal size |
| 112 | Stone aggregate below 40 mm nominal size |
| 113 | Stone aggregate 40 mm nominal size and above |
| 114 | Bricks |
| 115 | Plumbing and Sanitary Installations: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 116 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 117 | Providing and fixing white vitreous china pedestal for wash basincompletely recessed at the back for the reception of pipes and fittings. |
| 118 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board. 510x1040mm bowl depth 250mm |
| 119 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing. Rectangular shape 1500x450 mm |
| 120 | Providing and fixing toilet paper holder with Flap made out of C.P Brass |
| 121 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. . |
| 122 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. |
| 123 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 124 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. ofquality and make as approved by Engineer - in - charge. |
| 125 | Providing and fixing CP Brass 32mm size Bottle Trap of approvedquality & make and as per the direction of Engineer-in-charge. |
| 126 | Providing and fixing 15 mm nominal bore C.P. brass bib cock ofapproved quality conforming to IS : 8931 |
| 127 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 128 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) ofstandard design and of approved make conforming to IS : 8931 |
| 129 | Providing and fixing CP Brass Single lever telephonic wall mixer ofquality & make as approved by Engineer in charge. (a) 15 mm nominal dia |
| 130 | Providing and fixing CP Brass Over Head Shower of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia |
| 131 | Providing and fixing Stainless Steel Retractable Sink Basin Water DrainPipe of approved quality & make and as per the direction of Engineer-in-charge. (For Kitchen Sink) |
| 132 | Providing and fixing CP Brass Sink Mixer with Regular Swivel Spout ofquality & make as approved by Engineer in charge. |
| 133 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet150 mm diameter |
| 134 | Providing and fixing on wall face and on ground un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring confirming to IS:5283 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. 110 mm diameter |
| 135 | 75 mm diametre |
| 136 | Providing and fixing on wall face and on ground un-plasticized - PVC moulded fittings / accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler- 75 mm |
| 137 | 110 mm |
| 138 | Bend 87.5°. 75 mm bend |
| 139 | 110 mm bend |
| 140 | Shoe (plain). 75 mm shoe |
| 141 | 110 mm shoe |
| 142 | Providing and Fixing of Floor Traps 110 mm with double chrome plated Cover one Grated and one closed and all other fittings required.Makes:- Astral/SFMC/Finolex |
| 143 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete. 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm. nominal size) finished with a floatingcoat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class. designation 7.5 |
| 144 | Supply, Installation of PVC Gully Trap of Size 110 mm |
| 145 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.(SDR-11). Internal work Concealed fixing the pipe with clamps at1.00 meter spacing including cutting chases and making good the wall etc. 15mm nominal outer dia pipes |
| 146 | 20mm nominal outer dia pipes |
| 147 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.(SDR-11). Internal work-exposed on wall with clamps at 1.00 meterspacing. 25mm nominal outer dia pipes. |
| 148 | 32mm nominal outer dia pipes. |
| 149 | 40mm nominal outer dia pipes. |
| 150 | External work including trenching and refilling etc.complete. 40mm nominal outer dia pipes. |
| 151 | Providing and fixing unplasticised PVC connection pipe with brass unions: 45 cm length. 15 mm nominal bore |
| 152 | Cutting holes upto 30x30 cm in walls including making good the samewith common burnt clay F.P.S.(non modular) bricks |
| 153 | SH:V PVC STORAGE TANKS,VALVES AND GEYSERS Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 16 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 32 mm Diameter |
| 154 | 40 mm Diameter |
| 155 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 156 | Providing and fixing on wall 50 LTRS Electric Geyser with ABS Body. |
| 157 | Provifding and Fixing of Monoblock Pumpset with Brass Foot valve and Discharge of 120 LPM at a Head of 30 Meters along with Control Panel and other accessories to make the pump usable for water lifting from under ground Tank to Overhead Tank Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysOct 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender