Housing Urban and Rular Development Government Departments Closing in 7 days TDR #57552096

Tender For Balance Work Of Pre-Fabricated Structure At Gdc Marwah By Way Of Construction Of 02 No Septic Tanks,3Kva Solar Power Plant And Allied Works( C. No.12)

Issued by Government Departments · Kishtwar, Jammu and Kashmir
Tender Value
21.51 Lakhs
Estimated cost
Bid Submission
25 Sep 2026
7 days left
EMD
43020
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kishtwar → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Balance Work Of Pre-Fabricated Structure At Gdc Marwah By Way Of Construction Of 02 No Septic Tanks,3Kva Solar Power Plant And Allied Works( C. No.12)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Sep-2026 CORRIGENDUM Other 25-Sep-2026

BOQ

Name of Work:- Balance work of Pre-fabricated structure at GDC Marwah by way of Construction of 02 No Septic tanks,3kva solar power plant and allied works( C. No.12)
Sl. No. Item Description
1Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :
2Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
3Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
4Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
6Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
7Centering and Shuttering including strutting,propping etc
8Footing , Foundation Etc
9suspended floor
10edges of slab
11Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand)
1215mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix :1 : 3 ( 1 cement : 3 fine sand)
13SITC of Water Pump 1.0 Hp along with suitable connections and wiring complete job
14Providing and Fixing of Soil Waste and Vent Pipe along with following accessories
15110mm
164\\" bend
173\\" bend
184\\" Tee
193\\" Tee
20Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for singlepipe line-
21Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20m long complete as per standard design.
22Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. allcomplete as per direction of Engineer-in-charge.
23Design, Supply, Installation, Testing & Commissioning (DSITC) of 2 Nos. 3 kVA / 24V Solar Power Plants Solar Photovoltaic (SPV) Modules (6 no) :-Minimum 600 Wp Bifacial TOPCon Solar PV Modules listed under the latest MNRE Approved List of Models and Manufacturers (ALMM). Modules shall conform to IS 14286 / IEC 61215, IS/IEC 61730 (Part 1 & 2), IEC 62804 (PID Resistance), IEC 61701 (Salt Mist) and IEC 62716 (Ammonia Resistance), wherever applicable. Solar Power Conditioning Unit (PCU) ( 2 Sets) :- 3 kVA / 24V Solar Power Conditioning Unit with advanced MPPT charge controller, pure sine wave output, high conversion eAiciency, comprehensive electrical protections, LCD/LED display, and communication interface.Battery Bank with Battery Rack ( 2 Sets) :- 24V, 200Ah Lead Acid/VRLA Battery Bank using 12V batteries, connected as per the approved system design. Maximum two parallel strings shall be permitted. Batteries shall be tested by BIS-recognized laboratories and supplied with heavy-duty powder-coated battery racks Solar PV Module Mounting Structure (2 systems) :- Mono Rail mounting structure suitable for installation on tin-sheet roofing. Structure shall be manufactured from corrosion-resistant steel/All. with a minimum member thickness of 2 mm, hot-dip galvanized (minimum 80 microns, where applicable), and designed as per IS 875 (Part-3) for applicable wind loads AC & DC Cables with Accessories ( 2 systems) :- Copper FRLS/XLPO insulated AC & DC cables (minimum 4 sq.mm, or higher as per design),complete with UV-resistant conduits, cable trays, glands, lugs, ferrules, cable ties, and all associated accessories. Cables shall conform to IS 694, IS 1554, or equivalent IEC standards Grid/Load 6 Interconnection Wiring (50Mtr):- 4 sq.mm Copper FRLS cable complete with conduit/tray, cable glands, lugs, ferrules, and all accessories required for interconnection between the Solar Power Conditioning Unit and load/grid.
24Carriage of Material
25bajri
26bricks Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57552096
AUTHORITY Government Departments
TENDER VALUE 21.51 Lakhs
LAST DATE 25-09-2026
Authority
Authority Name Jammu And Kashmir Police Housing Corporation
Work Description Tender for Balance Work Of Pre-Fabricated Structure At Gdc Marwah By Way Of Construction Of 02 No Septic Tanks,3Kva Solar Power Plant And Allied Works( C. No.12)
Basic Detail
Tender No 12 of PHC JAMMU DIV/2026-27 Dated16-09-2026
Bidding Type Tender
Location
City Kishtwar
State Jammu and Kashmir
Key Dates
Publish Date 17 Sep 2026
Submission Date 25 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value 21.51 Lakhs
Tender Fee 1000
EMD 43020
Exemption Available
Document List
1f62033d-0257-4bf7-823d-955b8b1ac989.html
BOQ_1096442.xls
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 25, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 7 days
Sep 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

1f62033d-0257-4bf7-823d-955b8b1ac989.html

xls

BOQ_1096442.xls

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders