Tender For Balance Work Of Pre-Fabricated Structure At Gdc Marwah By Way Of Construction Of 02 No Septic Tanks,3Kva Solar Power Plant And Allied Works( C. No.12)
Tender Overview
Project Description
Tender for Balance Work Of Pre-Fabricated Structure At Gdc Marwah By Way Of Construction Of 02 No Septic Tanks,3Kva Solar Power Plant And Allied Works( C. No.12)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Sep-2026 | CORRIGENDUM | Other | 25-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 7 | Centering and Shuttering including strutting,propping etc |
| 8 | Footing , Foundation Etc |
| 9 | suspended floor |
| 10 | edges of slab |
| 11 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 12 | 15mm cement plaster on the rough side of single or half brick wall finished with a floating coat of neat cement of mix :1 : 3 ( 1 cement : 3 fine sand) |
| 13 | SITC of Water Pump 1.0 Hp along with suitable connections and wiring complete job |
| 14 | Providing and Fixing of Soil Waste and Vent Pipe along with following accessories |
| 15 | 110mm |
| 16 | 4\\" bend |
| 17 | 3\\" bend |
| 18 | 4\\" Tee |
| 19 | 3\\" Tee |
| 20 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for singlepipe line- |
| 21 | Constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20m long complete as per standard design. |
| 22 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. allcomplete as per direction of Engineer-in-charge. |
| 23 | Design, Supply, Installation, Testing & Commissioning (DSITC) of 2 Nos. 3 kVA / 24V Solar Power Plants Solar Photovoltaic (SPV) Modules (6 no) :-Minimum 600 Wp Bifacial TOPCon Solar PV Modules listed under the latest MNRE Approved List of Models and Manufacturers (ALMM). Modules shall conform to IS 14286 / IEC 61215, IS/IEC 61730 (Part 1 & 2), IEC 62804 (PID Resistance), IEC 61701 (Salt Mist) and IEC 62716 (Ammonia Resistance), wherever applicable. Solar Power Conditioning Unit (PCU) ( 2 Sets) :- 3 kVA / 24V Solar Power Conditioning Unit with advanced MPPT charge controller, pure sine wave output, high conversion eAiciency, comprehensive electrical protections, LCD/LED display, and communication interface.Battery Bank with Battery Rack ( 2 Sets) :- 24V, 200Ah Lead Acid/VRLA Battery Bank using 12V batteries, connected as per the approved system design. Maximum two parallel strings shall be permitted. Batteries shall be tested by BIS-recognized laboratories and supplied with heavy-duty powder-coated battery racks Solar PV Module Mounting Structure (2 systems) :- Mono Rail mounting structure suitable for installation on tin-sheet roofing. Structure shall be manufactured from corrosion-resistant steel/All. with a minimum member thickness of 2 mm, hot-dip galvanized (minimum 80 microns, where applicable), and designed as per IS 875 (Part-3) for applicable wind loads AC & DC Cables with Accessories ( 2 systems) :- Copper FRLS/XLPO insulated AC & DC cables (minimum 4 sq.mm, or higher as per design),complete with UV-resistant conduits, cable trays, glands, lugs, ferrules, cable ties, and all associated accessories. Cables shall conform to IS 694, IS 1554, or equivalent IEC standards Grid/Load 6 Interconnection Wiring (50Mtr):- 4 sq.mm Copper FRLS cable complete with conduit/tray, cable glands, lugs, ferrules, and all accessories required for interconnection between the Solar Power Conditioning Unit and load/grid. |
| 24 | Carriage of Material |
| 25 | bajri |
| 26 | bricks Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender