Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - 30 Sitc Of 1No 200Kva Ea Set At Te Mbm Karwar Sh Auxiliary Works; Electrical System Or Installation; Service Provider - Earthing With G.I. Earth Pla
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - 30 Sitc Of 1No 200Kva Ea Set At Te Mbm Karwar Sh Auxiliary Works; Electrical System Or Installation; Service Provider - Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Meter Long Etc.With Charcoal/ Coke And Salt As Required. , Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. , Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. , Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/Cable As Required. , Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V,On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar,Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying Laying Of One Number 3.5 Core 185 Sqmm Pvc / Xlpe Insulated Pvc Sheathe Power Cable Of 1.1 Kv Grade With Isi Mark In The Existing Masonry Open Duct/Pipe /Cble Chambour Etc As Required. , Supplying And Laying One Number 3.5 Core 185 Sq Mm Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade With Isi Mark Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. , Supplying And Laying Of One Number 3.5 Core 185 Sqmm Additional Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade With Isi Mark Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation,Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. , Providing And Fixing M.V. Danger Notice Plate Of 200 Mm X 150 Mm, Made Of Mild Steel, At Least 2 Mm Thick, And Vitreous Enamelled White On Both Sides, And With Inscription In Single Red Colour On Front Side As Required. , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. , Providing, Laying And Fixing Following Dia G.I. Pipe (Medium Class) In Ground Complete With G.I. Fittings Including Trenching (75 Cm Deep)And Re-Filling Etc As Required , Supplying And Laying Of High-Quality Electrical Insulating Rubber (Isi Marked As Per Is 15652:2006) Mat Suitable For Mv Supply As Required. (Appr:2.5Mm Thick) , Supply And Fixing Of 4.5 Kg Co2 Fire Extinguisher On Wall Of Seamless M.S. Cylinder As Per Is 15683:2018 / Is 7285, Isi Marked On Cylinder And Valve Assembly, Self-Contained Co₂ Under Pressure,Squeeze Grip Control Valve With Discharge Horn & Hose. Including Providing Hooks Etc.. As Reqd. (Make :Safex / Ceasefire / Minimax / Kanex / Firex / Hd / Newage) , Supplying And Fixing Of M.S. Fire Bucket, 9L Capacity On Wall With Painted Red With White Fire Lettering (As Per Is Standard Color Code), Filling Clear River Sand , Providing Ms Hook/Stand For Hanging Etc… As Reqd. , Supplying And Laying 3X2.5 Sqmm Copper Conductor Armoured Ug Cable Of 1.1 Kv Grade With Isi Mark In The Existing Trench /Pipe I/C Termination Etc As Reqd , Providing And Fixing Of M.S. Enclosure Made Of 16 Guage Crca Sheet Of Size 600X400x250 Mm Duly Painted , With 4 Nos 300A Capacity Al Bus Bar Of 30 Cm Legth With Suitable Smc Insulators , Cable Gland Plates For 4 Nos Armoured Cable ,Doors With Nuts And Bolts,Fixing On Wall, Making Connections,Earthing Etc. As Required.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required. | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required. |
| 2 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 3 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 4 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/cable as required. | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/cable as required. |
| 5 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 7 | Supplying Laying of one number 3.5 core 185 sqmm PVC / XLPE insulated PVC sheathe power cable of 1.1 KV grade with ISI Mark in the existing masonry open duct/pipe /cble chambour etc as required. | Supplying Laying of one number 3.5 core 185 sqmm PVC / XLPE insulated PVC sheathe power cable of 1.1 KV grade with ISI Mark in the existing masonry open duct/pipe /cble chambour etc as required. |
| 8 | Supplying and laying one number 3.5 core 185 SQ mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade with ISI mark direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. | Supplying and laying one number 3.5 core 185 SQ mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade with ISI mark direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 9 | Supplying and Laying of one number 3.5 core 185 sqmm additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade with ISI Mark direct in ground in the same trench in one tier horizontal formation including excavation,sand cushioning, protective covering and refilling the trench etc as required. | Supplying and Laying of one number 3.5 core 185 sqmm additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade with ISI Mark direct in ground in the same trench in one tier horizontal formation including excavation,sand cushioning, protective covering and refilling the trench etc as required. |
| 10 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. |
| 11 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 12 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 13 | Supplying and laying of High-quality electrical insulating rubber (ISI marked as per IS 15652:2006) mat suitable for MV supply as required. (Appr:2.5mm thick) | Supplying and laying of High-quality electrical insulating rubber (ISI marked as per IS 15652:2006) mat suitable for MV supply as required. (Appr:2.5mm thick) |
| 14 | Supply and Fixing of 4.5 Kg CO2 FIRE Extinguisher on wall of Seamless M.S. cylinder as per IS 15683:2018 / IS 7285, ISI marked on cylinder and valve assembly, Self-contained CO₂ under pressure,Squeeze grip control valve with discharge horn & hose. Including providing hooks etc.. As reqd. (Make :Safex / Ceasefire / Minimax / Kanex / Firex / HD / NewAge) | Supply and Fixing of 4.5 Kg CO2 FIRE Extinguisher on wall of Seamless M.S. cylinder as per IS 15683:2018 / IS 7285, ISI marked on cylinder and valve assembly, Self-contained CO₂ under pressure,Squeeze grip control valve with discharge horn & hose. Including providing hooks etc.. As reqd. (Make :Safex / Ceasefire / Minimax / Kanex / Firex / HD / NewAge) |
| 15 | Supplying and Fixing of M.S. fire bucket, 9L capacity on wall with Painted red with white “FIRE” lettering (as per IS standard color code), filling clear river sand , providing MS hook/Stand for hanging etc… as reqd. | Supplying and Fixing of M.S. fire bucket, 9L capacity on wall with Painted red with white “FIRE” lettering (as per IS standard color code), filling clear river sand , providing MS hook/Stand for hanging etc… as reqd. |
| 16 | Supplying and laying 3x2.5 sqmm copper conductor armoured UG cable of 1.1 KV grade with ISI mark in the existing trench /pipe i/c termination etc as reqd | Supplying and laying 3x2.5 sqmm copper conductor armoured UG cable of 1.1 KV grade with ISI mark in the existing trench /pipe i/c termination etc as reqd |
| 17 | Providing and fixing of M.S. enclosure made of 16 guage CRCA sheet of size 600x400x250 mm duly painted , with 4 nos 300A capacity AL bus bar of 30 cm Legth with suitable SMC insulators , cable gland plates for 4 nos armoured cable ,doors with nuts and bolts,fixing on wall, making connections,earthing etc. as required. | Providing and fixing of M.S. enclosure made of 16 guage CRCA sheet of size 600x400x250 mm duly painted , with 4 nos 300A capacity AL bus bar of 30 cm Legth with suitable SMC insulators , cable gland plates for 4 nos armoured cable ,doors with nuts and bolts,fixing on wall, making connections,earthing etc. as required. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender