Educational and Research Institute Statutory Bodies & Commissions/Committees Closing in 7 days TDR #57549628

Bids Are invited for Design Installation And Maintenance Of Educational Lab/Centre - Science Lab; Supply And Installation Of Hardware; Buyer - Pipe Vice 4 , Wood Working Lath Machine, 1Hp Motor , Digital Nephelometerauto Ranging From 20-200Ntu, +/-2%

Issued by Statutory Bodies & Commissions/Committees · Chamoli, Uttarakhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
26 Sep 2026
7 days left
EMD
30000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chamoli → Uttarakhand
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Design Installation And Maintenance Of Educational Lab/Centre - Science Lab; Supply And Installation Of Hardware; Buyer - Pipe Vice 4 , Wood Working Lath Machine, 1Hp Motor , Digital Nephelometerauto Ranging From 20-200Ntu, +/-2% Of Readingplus 0.1 Ntu, Power 220 Volts+/-10%Ac50hz , Electric Oven Inner Size 18*18*18 Tempreture Range 100To200degree Celcius Of 40 Lit , Conductivity Meter - Conductivity Range -0.01Us/Cm To 200Ms/Cm, Cell Constant- Digital 0.1 To 2.00; Temperature Range -00C To1000c , Hollow Cylinder 10Cm Length 5Cm Dia , Solid Cylinder 10Cm Length 5Cm Dia , Copper Wire Roll 200 Gram , Steel Ball : 2Mm, 3Mm, 5Mm, 8Mm, 10Mm, 12Mm Dia (5 Each) , Stop Watch , Multimeter - Voltage Testing, Current Testing, Continiuty Check And Testing, Ac Testing, De Testing & All Eletronic Uints , Measurements, Transistor Test (Npn & Pnp), Diode Test: Yes, With Audiuble Continuity Check, Power Supply: 9V Battery, Operating Temperature: ℃ To 40 ℃, Display 31/2 Digital Lcd With A Maxi. Reading Of 1999, Diode Test: Yes With Visual Indcation. , Lees Disc Method For Thermal Conductivity (Non-Metalllic Solid) , Sonometer , Diode,Led, Transitor,Resistor, Capcitor , Sprit Level , Glass Slab For Refractive Index (7.5Cm X 15Cmx 1Cm/2Cm) , Steel Wire Roll 500 Gram , Fortains Barometer , Searles Apparatus Of Thermal Conductivity , Meldes Experiment (Frequency Of Ac/Electric Vibrator) - Complete With Power Supply , Kirchoffs Law Kit - Consists Of Two Analog Meters And Regulated Power Supply , Steam Generator , Ohms Law Kit -To Verify Ohms Law Consists Of One Dial Type Rheostat, M065 Moving Coil Voltmeter 5 Volt & Milliammeter 500Ma Mounted In Spray Painted Metal Box With Terminal Supplied Without Resistance Coil And Power Supply , Travelling Microscope (Packed In Wooden Box)- The Microscope Consist Of A Heavy Cast Iron Based Filtred With Three Leveling Screws With The Top Machined Over Which Slides A Gun Metal Carriage. The Slide Can Be Cl Ed At Any Position By Means Of A Cl Ings Screw, Fine Adjustment For Final Reading Are Done With A Micrometer Screw. A Verticle Slide Operating In A Similar Way Is Fitted On The Horizantal Carriage. The Microscope With Rack & Pinion Is Fitte On The Verticle & Horizantal Postion Of Microscope, Microscope Tube Is Fitted With High Quality Eye Piece Travels Horizontally & Vertically. Guranteed Accurate Vernier Reading 0.02 Or 0.01Mm, Packed In A Sturdy Wooden Box , Battery Eliminator (O/P 2-12V) Dc , Insulated Copper Connection Wire 10 Meter , Electronic Balance, With Scale Range Of 0.001Gm To 500.0Gm, Pan Size 100Mm; Response Time 3-5 Sec; Power Requirement 90-250 V, 10Watt , Ph Meter Reading Up To Ph14; Ambient Temperature -40 To 700C.;, Ph/Mv Resolution:13 Bit , Redwood Viscometer, Power: Single Phase, 220-240V, 50/60Hz, 6.0A Or 115V, 12.0A, Max Working Temperature: 990C, Capacity: 1 S Le At A Time, Net Weight: 12 Lbs (5.5Kg), Input Power Supply: 230 V Ac, 50 Hz, 1 Phase With 6- Current Rating , Cleveland Open Cup Apparatus The Cleveland Flash And Fire Point Apparatus Is A Laboratory Instrument Designed To Determine The Flash Point And Fire Point Of Petroleum Products And Lubricants With Flash Points Above 79°C (175°F). It Uses The Open Cup Method, Where The S Le Is Gradually Heated And Exposed To An Ignition Source At Specific Intervals. This Apparatus Is Essential For Assessing The Flammability And Fire Hazard Of Oils, Fuels, And Other Volatile Materials. It Is Widely Used In Petroleum, Chemical, Automotive, And Industrial Laboratories And Complies With International Testing Standards Such As Astm D92, Ip 36, And Is: 1448 (Part 69). The Setup Includes A Brass Test Cup, Heating Unit, Thermometer Clip, Flame Exposure Mechanism, And A Metallic Air Bath. Both Manual And Electrically Operated Versions Are Available. , Electrolysis Apparatus , Water Distillation Unit , Turbidity Meter Range 0 To 1000 Ntu, Resolution 1 Ntu, Operating Temprature 10 To 45 Degree C , Dgps (For Civil Lab) Dual-Frequency Base+Rover - Type Of System For Civil Engineering Surveying ,Topographical Survey ,Road Survey ,Earthwork, Construction Layout Surveying Work . Specifications Insist On Feature Configuration Base + Rover Gnss Gps +Glonass + Galileo Multi/ Dual Frequency. Rtk,Ppk,Static Survey,Dgps,Ntrip/Network Rtk,Uhf Radio,4G.Tilt Compensation Preferably Horizontal Accuracy ~8 Mm + 1 Ppm Or Better Vertical Accuracy ~15 Mm + 1 Ppm Or Better Controller Android Field Controller Software Survey + Cogo + Stakeout + Export Protection Ip68 Preferred Gnss Systems Can Combine Multiple Satellite Constellations To Improve Availability And Positioning Performance; , Bench Grinder 200 Mm - Double Ended , Daniel Cell

BOQ

Sl. No. Item TitleItem Description
1Pipe Vice 4\\"Pipe Vice 4\\"
2Wood working lath machine, 1HP motorWood working lath machine, 1HP motor
3Digital NephelometerAuto ranging from 20-200NTU, +/-2% of readingplus 0.1 NTU, power 220 volts+/-10%AC50HzDigital NephelometerAuto ranging from 20-200NTU, +/-2% of readingplus 0.1 NTU, power 220 volts+/-10%AC50Hz
4Electric oven inner size 18*18*18 tempreture range 100to200degree celcius of 40 LitElectric oven inner size 18*18*18 tempreture range 100to200degree celcius of 40 Lit
5Conductivity meter - Conductivity range -0.01uS/cm to 200mS/cm, Cell constant- digital 0.1 to 2.00; Temperature range -00C to1000CConductivity meter - Conductivity range -0.01uS/cm to 200mS/cm, Cell constant- digital 0.1 to 2.00; Temperature range -00C to1000C
6Hollow Cylinder 10cm length 5cm diaHollow Cylinder 10cm length 5cm dia
7Solid Cylinder 10cm length 5cm diaSolid Cylinder 10cm length 5cm dia
8Copper wire roll 200 gramCopper wire roll 200 gram
9Steel ball : 2mm, 3mm, 5mm, 8mm, 10mm, 12mm dia (5 Each)Steel ball : 2mm, 3mm, 5mm, 8mm, 10mm, 12mm dia (5 Each)
10Stop watchStop watch
11Multimeter - Voltage testing, current Testing, continiuty check and testing, AC testing, DE Testing & all eletronic uints , measurements, transistor test (NPN & PNP), Diode test: Yes, with audiuble continuity check, power supply: 9V battery, operating temperature: ℃ to 40 ℃, display 31/2 digital LCD with a maxi. reading of 1999, Diode test: YES with visual indcation.Multimeter - Voltage testing, current Testing, continiuty check and testing, AC testing, DE Testing & all eletronic uints , measurements, transistor test (NPN & PNP), Diode test: Yes, with audiuble continuity check, power supply: 9V battery, operating temperature: ℃ to 40 ℃, display 31/2 digital LCD with a maxi. reading of 1999, Diode test: YES with visual indcation.
12Lee's Disc method for thermal conductivity (non-metalllic solid)Lee's Disc method for thermal conductivity (non-metalllic solid)
13SonometerSonometer
14Diode,LED, Transitor,Resistor, CapcitorDiode,LED, Transitor,Resistor, Capcitor
15Sprit levelSprit level
16Glass slab for refractive Index (7.5cm x 15cmx 1cm/2cm)Glass slab for refractive Index (7.5cm x 15cmx 1cm/2cm)
17Steel wire roll 500 gramSteel wire roll 500 gram
18Fortain's BarometerFortain's Barometer
19Searles Apparatus of Thermal conductivitySearles Apparatus of Thermal conductivity
20Melde's Experiment (frequency of AC/Electric Vibrator) - Complete with power SupplyMelde's Experiment (frequency of AC/Electric Vibrator) - Complete with power Supply
21Kirchoffs law kit - Consists of two analog meters and regulated power supplyKirchoffs law kit - Consists of two analog meters and regulated power supply
22Steam generatorSteam generator
23Ohm's Law kit -To verify ohm's law consists of one dial type rheostat, M065 moving coil voltmeter 5 volt & milliammeter 500mA mounted in spray painted metal box with terminal supplied without resistance coil and power supplyOhm's Law kit -To verify ohm's law consists of one dial type rheostat, M065 moving coil voltmeter 5 volt & milliammeter 500mA mounted in spray painted metal box with terminal supplied without resistance coil and power supply
24Travelling Microscope (packed in wooden box)- The microscope consist of a heavy cast iron based filtred with three leveling screws with the top machined over which slides a gun metal carriage. The slide can be clamped at any position by means of a clampings screw, Fine adjustment for final reading are done with a micrometer screw. A verticle slide operating in a similar way is fitted on the horizantal carriage. The Microscope with rack & pinion is fitte on the verticle & horizantal postion of microscope, microscope tube is fitted with high quality eye piece travels horizontally & vertically. Guranteed accurate vernier reading 0.02 or 0.01mm, packed in a sturdy wooden boxTravelling Microscope (packed in wooden box)- The microscope consist of a heavy cast iron based filtred with three leveling screws with the top machined over which slides a gun metal carriage. The slide can be clamped at any position by means of a clampings screw, Fine adjustment for final reading are done with a micrometer screw. A verticle slide operating in a similar way is fitted on the horizantal carriage. The Microscope with rack & pinion is fitte on the verticle & horizantal postion of microscope, microscope tube is fitted with high quality eye piece travels horizontally & vertically. Guranteed accurate vernier reading 0.02 or 0.01mm, packed in a sturdy wooden box
25Battery Eliminator (O/P 2-12V) DCBattery Eliminator (O/P 2-12V) DC
26Insulated copper connection wire 10 meterInsulated copper connection wire 10 meter
27Electronic balance, with scale range of 0.001gm to 500.0gm, pan size 100mm; response time 3-5 sec; power requirement 90-250 V, 10wattElectronic balance, with scale range of 0.001gm to 500.0gm, pan size 100mm; response time 3-5 sec; power requirement 90-250 V, 10watt
28pH meter reading up to pH14; ambient temperature -40 to 700C.;, pH/mV resolution:13 bitpH meter reading up to pH14; ambient temperature -40 to 700C.;, pH/mV resolution:13 bit
29Redwood Viscometer, Power: single phase, 220-240v, 50/60hz, 6.0a or 115v, 12.0a, Max Working Temperature: 990C, Capacity: 1 sample at a time, Net weight: 12 lbs (5.5kg), Input power supply: 230 V ac, 50 hz, 1 phase with 6-amp current ratingRedwood Viscometer, Power: single phase, 220-240v, 50/60hz, 6.0a or 115v, 12.0a, Max Working Temperature: 990C, Capacity: 1 sample at a time, Net weight: 12 lbs (5.5kg), Input power supply: 230 V ac, 50 hz, 1 phase with 6-amp current rating
30Cleveland open cup apparatus The Cleveland Flash and Fire Point Apparatus is a laboratory instrument designed to determine the flash point and fire point of petroleum products and lubricants with flash points above 79°C (175°F). It uses the open cup method, where the sample is gradually heated and exposed to an ignition source at specific intervals. This apparatus is essential for assessing the flammability and fire hazard of oils, fuels, and other volatile materials. It is widely used in petroleum, chemical, automotive, and industrial laboratories and complies with international testing standards such as ASTM D92, IP 36, and IS: 1448 (Part 69). The setup includes a brass test cup, heating unit, thermometer clip, flame exposure mechanism, and a metallic air bath. Both manual and electrically operated versions are available.Cleveland open cup apparatus The Cleveland Flash and Fire Point Apparatus is a laboratory instrument designed to determine the flash point and fire point of petroleum products and lubricants with flash points above 79°C (175°F). It uses the open cup method, where the sample is gradually heated and exposed to an ignition source at specific intervals. This apparatus is essential for assessing the flammability and fire hazard of oils, fuels, and other volatile materials. It is widely used in petroleum, chemical, automotive, and industrial laboratories and complies with international testing standards such as ASTM D92, IP 36, and IS: 1448 (Part 69). The setup includes a brass test cup, heating unit, thermometer clip, flame exposure mechanism, and a metallic air bath. Both manual and electrically operated versions are available.
31Electrolysis apparatusElectrolysis apparatus
32Water distillation unitWater distillation unit
33Turbidity meter range 0 to 1000 ntu, resolution 1 ntu, operating temprature 10 to 45 degree CTurbidity meter range 0 to 1000 ntu, resolution 1 ntu, operating temprature 10 to 45 degree C
34DGPS (for Civil Lab) Dual-Frequency Base+Rover - Type of system for civil engineering surveying ,topographical survey ,road survey ,earthwork, construction layout surveying work . Specifications insist on Feature Configuration Base + Rover GNSS GPS +GLONASS + Galileo multi/ dual frequency. RTK,PPK,Static survey,DGPS,NTRIP/Network RTK,UHF radio,4G.Tilt compensation Preferably Horizontal accuracy ~8 mm + 1 ppm or better Vertical accuracy ~15 mm + 1 ppm or better Controller Android field controller Software Survey + COGO + stakeout + export Protection IP68 preferred GNSS systems can combine multiple satellite constellations to improve availability and positioning performance;DGPS (for Civil Lab) Dual-Frequency Base+Rover - Type of system for civil engineering surveying ,topographical survey ,road survey ,earthwork, construction layout surveying work . Specifications insist on Feature Configuration Base + Rover GNSS GPS +GLONASS + Galileo multi/ dual frequency. RTK,PPK,Static survey,DGPS,NTRIP/Network RTK,UHF radio,4G.Tilt compensation Preferably Horizontal accuracy ~8 mm + 1 ppm or better Vertical accuracy ~15 mm + 1 ppm or better Controller Android field controller Software Survey + COGO + stakeout + export Protection IP68 preferred GNSS systems can combine multiple satellite constellations to improve availability and positioning performance;
35Bench grinder 200 mm - Double endedBench grinder 200 mm - Double ended
36Daniel CellDaniel Cell

AI Tender Summary

OUR REF NO 57549628
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 26-09-2026
Authority
Authority Name Directorate Of Technical Education
Work Description Bids Are invited for Design Installation And Maintenance Of Educational Lab/Centre - Science Lab; Supply And Installation Of Hardware; Buyer - Pipe Vice 4 , Wood Working Lath Machine, 1Hp Motor , Digital Nephelometerauto Ranging From 20-200Ntu, +/-2% Of Readingplus 0.1 Ntu, Power 220 Volts+/-10%Ac50hz , Electric Oven Inner Size 18*18*18 Tempreture Range 100To200degree Celcius Of 40 Lit , Conductivity Meter - Conductivity Range -0.01Us/Cm To 200Ms/Cm, Cell Constant- Digital 0.1 To 2.00; Temperature Range -00C To1000c , Hollow Cylinder 10Cm Length 5Cm Dia , Solid Cylinder 10Cm Length 5Cm Dia , Copper Wire Roll 200 Gram , Steel Ball : 2Mm, 3Mm, 5Mm, 8Mm, 10Mm, 12Mm Dia (5 Each) , Stop Watch , Multimeter - Voltage Testing, Current Testing, Continiuty Check And Testing, Ac Testing, De Testing & All Eletronic Uints , Measurements, Transistor Test (Npn & Pnp), Diode Test: Yes, With Audiuble Continuity Check, Power Supply: 9V Battery, Operating Temperature: ℃ To 40 ℃, Display 31/2 Digital Lcd With A Maxi. Reading Of 1999, Diode Test: Yes With Visual Indcation. , Lees Disc Method For Thermal Conductivity (Non-Metalllic Solid) , Sonometer , Diode,Led, Transitor,Resistor, Capcitor , Sprit Level , Glass Slab For Refractive Index (7.5Cm X 15Cmx 1Cm/2Cm) , Steel Wire Roll 500 Gram , Fortains Barometer , Searles Apparatus Of Thermal Conductivity , Meldes Experiment (Frequency Of Ac/Electric Vibrator) - Complete With Power Supply , Kirchoffs Law Kit - Consists Of Two Analog Meters And Regulated Power Supply , Steam Generator , Ohms Law Kit -To Verify Ohms Law Consists Of One Dial Type Rheostat, M065 Moving Coil Voltmeter 5 Volt & Milliammeter 500Ma Mounted In Spray Painted Metal Box With Terminal Supplied Without Resistance Coil And Power Supply , Travelling Microscope (Packed In Wooden Box)- The Microscope Consist Of A Heavy Cast Iron Based Filtred With Three Leveling Screws With The Top Machined Over Which Slides A Gun Metal Carriage. The Slide Can Be Cl Ed At Any Position By Means Of A Cl Ings Screw, Fine Adjustment For Final Reading Are Done With A Micrometer Screw. A Verticle Slide Operating In A Similar Way Is Fitted On The Horizantal Carriage. The Microscope With Rack & Pinion Is Fitte On The Verticle & Horizantal Postion Of Microscope, Microscope Tube Is Fitted With High Quality Eye Piece Travels Horizontally & Vertically. Guranteed Accurate Vernier Reading 0.02 Or 0.01Mm, Packed In A Sturdy Wooden Box , Battery Eliminator (O/P 2-12V) Dc , Insulated Copper Connection Wire 10 Meter , Electronic Balance, With Scale Range Of 0.001Gm To 500.0Gm, Pan Size 100Mm; Response Time 3-5 Sec; Power Requirement 90-250 V, 10Watt , Ph Meter Reading Up To Ph14; Ambient Temperature -40 To 700C.;, Ph/Mv Resolution:13 Bit , Redwood Viscometer, Power: Single Phase, 220-240V, 50/60Hz, 6.0A Or 115V, 12.0A, Max Working Temperature: 990C, Capacity: 1 S Le At A Time, Net Weight: 12 Lbs (5.5Kg), Input Power Supply: 230 V Ac, 50 Hz, 1 Phase With 6- Current Rating , Cleveland Open Cup Apparatus The Cleveland Flash And Fire Point Apparatus Is A Laboratory Instrument Designed To Determine The Flash Point And Fire Point Of Petroleum Products And Lubricants With Flash Points Above 79°C (175°F). It Uses The Open Cup Method, Where The S Le Is Gradually Heated And Exposed To An Ignition Source At Specific Intervals. This Apparatus Is Essential For Assessing The Flammability And Fire Hazard Of Oils, Fuels, And Other Volatile Materials. It Is Widely Used In Petroleum, Chemical, Automotive, And Industrial Laboratories And Complies With International Testing Standards Such As Astm D92, Ip 36, And Is: 1448 (Part 69). The Setup Includes A Brass Test Cup, Heating Unit, Thermometer Clip, Flame Exposure Mechanism, And A Metallic Air Bath. Both Manual And Electrically Operated Versions Are Available. , Electrolysis Apparatus , Water Distillation Unit , Turbidity Meter Range 0 To 1000 Ntu, Resolution 1 Ntu, Operating Temprature 10 To 45 Degree C , Dgps (For Civil Lab) Dual-Frequency Base+Rover - Type Of System For Civil Engineering Surveying ,Topographical Survey ,Road Survey ,Earthwork, Construction Layout Surveying Work . Specifications Insist On Feature Configuration Base + Rover Gnss Gps +Glonass + Galileo Multi/ Dual Frequency. Rtk,Ppk,Static Survey,Dgps,Ntrip/Network Rtk,Uhf Radio,4G.Tilt Compensation Preferably Horizontal Accuracy ~8 Mm + 1 Ppm Or Better Vertical Accuracy ~15 Mm + 1 Ppm Or Better Controller Android Field Controller Software Survey + Cogo + Stakeout + Export Protection Ip68 Preferred Gnss Systems Can Combine Multiple Satellite Constellations To Improve Availability And Positioning Performance; , Bench Grinder 200 Mm - Double Ended , Daniel Cell
Basic Detail
Tender No GEM/2026/B/8042952
Bidding Type Tender
Location
City Chamoli
State Uttarakhand
Key Dates
Publish Date 16 Sep 2026
Submission Date 26 Sep 2026
Open Date 27 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 30000
Exemption Not Available
Document List
18f3b2ba-47f3-45af-bfa5-56d258ee7dad.pdf
1789559168.xlsx
1789559209.pdf
1789559217.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
pdf

18f3b2ba-47f3-45af-bfa5-56d258ee7dad.pdf

xlsx

1789559168.xlsx

pdf

1789559209.pdf

pdf

1789559217.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders