Tender for General-General-Daily Operation Of electrical installation In Ssb Of Mch 2026-2027-Daily Operation Of electrical installation In Ssb Of Mch-Daily Operation Of electrical installation In Super Specialty Block Of Mch Tvpm For The Period From 01.11.2026 To 31.10.2027General Electrical Work-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Electrification |
| 2 | OD151786/2025-2026:Supply and engaging the following round the clock duty staff, having qualifications as mentioned alongwith for the operation and maintenance of the existing Substation consisting of 2 Nos. 1000 KVA Transformers, 2 Nos. 750 KVA DG set, HT /LT control Panels and other Electrical installations provided in the Super-Specialty Block of Medical college Thiruvananthapuram, under the control of Assistant Engineer (Electrical) PWD, Medical College Section, and operating the system round the clock, as per his direction. The Sub-Station should be operated round the clock, daily by engaging staffs arranged in 3 shifts. The staff requirement in each shift is as follows: 1) Diploma holder in Electrical Engineering, recognized by Board of Technical Examination Kerala with minimum of 3 years experience - 1 No. 2) ITI/ITC certificate holder in Electrical/Wireman trade, recognized by NCVT with minimum of 2 years experience. - 3 Nos. The electrical installations shall be operated and maintained as per the directions of the Assistant Engineer, PWD Electrical Section, MCH or as detailed in the mode of operation attached separately. The certificates of the operating staff should be produced before the tendering authority at time of agreement. The attendance Register of the staff shall be maintained strictly by the Assistant Engineer, PWD MCH Section. The safety precautions of the operators/staff shall be maintained by the contractor himself. Necessary liaison work regarding the operating staff in connection with the guidelines of Labour department and government and shall be the responsibility of the contractor. |
| 3 | OD141523/2026-2027:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSH PVC insulated copper conductor single core cable etc as required. Group C |
| 4 | OD132830/2026-2027:Supply of 3600 lumen square (2ft X 2ft) recessed fitting made of crca sheet of thickness 0.5mm, having efficacy not less than 110l/w, pf greater than 0.95, THD less than or equal to 10%, Chip make Cree/Osram/lumilled/Nichea (UGR less than 19) pre-wired fluorescent fitting complete with all accessories and fluorescent lamps etc. suspended from ceiling using 4 nos steel chain (16 SWG or nearest) of length not exceeding 30 cm properly hooked to steel hooks anchored to the ceiling and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required. (for fitting in false ceiling) |
| 5 | OD132872/2026-2027:Supply of new driver for 2 x 2 ft light firings with THD less than or equal to 10% power factor greater than 0.95, ROHS compliant suitable for use 140-280V AC 50 Hz AC of 600 x 600 mm recessed/surface LED light fittings. |
| 6 | OD132831/2026-2027:Supply, of 1x18/20W LED pre-wired G13 base with LED Tube poly carbonate body (cool white at 6500 K temprature )extruded Aluminium heat sink , 1200 mm, T8 I, 18/20 w with nominal system level lumen pakage of 2000 Lumen having effiency of minimum 110/100 lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. The light shall be made by Polycarbonate housing (IP20 protection) with minimum 3 KV surge protection. . The light should have minimum 70% of light at 40000 Hr life time as per LM 79 NABL Accradation certification. LED used in this light should be from manufacturer of Lumileds/Osram/Cree/Nichia make. |
| 7 | OD132829/2026-2027:Supply of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% including remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: |
| 8 | OD132828/2026-2027:Supply of 400 mm WALL MOUNTING FAN , having Metallic construction, Metal Blade, Thermal overload etc including fastener and screws. |
| 9 | OD132832/2026-2027:Supply of exhaust fans (in and out type) of size 225 mm sweep 1350/1400 RPM Exhaust fan in metal frame with metal guard , bird guard including anti corrosive powder coated , working on 230 V A/C single phase A/C existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan as required (almonard or its equivalent) |
| 10 | OD132833/2026-2027:Supply of 300/305mm sweep light duty Exhaust fan in metal frame waking on 230V A/C in the existing opening, etc. as required. |
| 11 | OD132834/2026-2027:Supply of 380 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. |
| 12 | OD135729/2026-2027:Supply of 10 W LED bulk head fitting IP 65 die cast aluminium body suitable for 230V Ac supply to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required. |
| 13 | OD135231/2026-2027:Supply ,installation,testing and commissioning of 4200 lumen LED, efficacy >=120 Lm/watt, IP 66 street light fitting with die-cast aluminium housing, polycarbonate cover complete with THD 0.95, RoHS compliant, duly wired up for use on 230 V AC supply, IK >=7,CRI>=70 with internal surge protection 4k above. Chip make Cree/Osram/lumilled/Nichea/Bridgelux.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 14 | OD132835/2026-2027:Supply of 9W B22 type LED Bulb. |
| 15 | OD139768/2026-2027:Supply,Conveyance of LED box type tube fittings. The fittings shall be made from CRCA MS sheet of minimum thickness 0.50 mm nominal thickness inside & outside with 1x18/20W LED pre-wired G13 base with LED Tube poly carbonate body (cool white at 6500 K temprature )extruded Aluminium heat sink , 1200 mm, T8 I, 18/20 w with nominal system level lumen pakage of 2000 Lumen having effiency of minimum 110/100 lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. The light shall be made by Polycarbonate housing (IP20 protection) with minimum 3 KV surge protection. . The light should have minimum 70% of light at 40000 Hr life time as per LM 79 NABL Accradation certification. LED used in this light should be from manufacturer of Lumileds/Osram/Cree/Nichia make. |
| 16 | OD133448/2026-2027:Supply of new 3 pin ceiling rose |
| 17 | OD139677/2026-2027:Supplying and fixing extra steel rop 1.5/2 mm along with the conduit down rod of 20 cm length etc. as required. |
| 18 | OD133445/2026-2027:Supply of 2.25 Mfd Capacitor for Ceiling Fan |
| 19 | OD133441/2026-2027:Supply of 220v wall mounted call bell/ buzzer. |
| 20 | OD133439/2026-2027:Supply of 25 mm dia PVC flexible conduit with accessories. |
| 21 | OD141608/2026-2027:Supplying following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way, Double door |
| 22 | OD135550/2026-2027:Supplying the following types/ sizes of boxes suitable for modular accessories in surface/ recess (RoHS compliant )2 module moulded plastic box on surface |
| 23 | OD133095/2026-2027:Supply of the following types/ sizes of boxes suitable for modular accessories in surface/ recess (RoHS compliant )3 module moulded plastic box on surface |
| 24 | OD133098/2026-2027:Supply of the following types/ sizes of boxes suitable for modular accessories in surface/ recess (RoHS compliant ) 6module moulded plastic box on surface |
| 25 | OD135577/2026-2027:Supplying the following types/ sizes of boxes suitable for modular accessories in surface/ recess(RoHS compliant )10 module moulded plastic box on surface |
| 26 | OD141609/2026-2027:Supplying the following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module |
| 27 | OD141610/2026-2027:Supplying the following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 28 | OD141611/2026-2027:Supplying the following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module |
| 29 | OD135576/2026-2027:Supplying following Modular base & cover plate on existing modular metal boxes etc. as required.10/12 Module |
| 30 | OD133561/2026-2027:Supplying of following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes . 25 amps |
| 31 | OD133558/2026-2027:Supplying of following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes. 40 amps |
| 32 | OD133560/2026-2027:Supplying of following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes. 25 amps |
| 33 | OD133557/2026-2027:Supplying of following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes . 40 amps |
| 34 | OD133559/2026-2027:Supplying of following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes. 63 amps |
| 35 | OD133553/2026-2027:Supplying of following rating, double pole, 240 volts, isolator. 40 amps |
| 36 | OD133552/2026-2027:Supplying of following rating, double pole, 240 volts, isolator .63 amps |
| 37 | OD133551/2026-2027:Supplying of following rating, four pole, 415 volts, isolator.40 amps |
| 38 | OD133550/2026-2027:Supplying of following rating, four pole, 415 volts, isolator .63 amps |
| 39 | OD133555/2026-2027:Supplying of 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles. Single pole |
| 40 | OD133556/2026-2027:Supplying of 5A to 32 A rating, 240 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles. Double pole |
| 41 | OD133554/2026-2027:Supplying of 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles. Triple pole |
| 42 | OD137944/2026-2027:Supplying the 40 A to 63 A, TP MCB (C curve), 10 kA breaking capacity rating, 415 volts in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 43 | OD141615/2026-2027:Supplying of 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 44 | OD141616/2026-2027:Supplying of 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 45 | OD142969/2026-2027:Supplying of 2A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 46 | OD137877/2026-2027:Supplying the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 47 | OD137876/2026-2027:Supplying the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm |
| 48 | OD137872/2026-2027:Supplying the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 49 | OD141625/2026-2027:Supplying the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 6 x 2.5 sq. mm |
| 50 | OD137875/2026-2027:Supplying the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 51 | OD137874/2026-2027:Supplying the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm |
| 52 | OD141629/2026-2027:Supplying the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 6 x 4 sq. mm |
| 53 | OD137873/2026-2027:Supplying the following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm |
| 54 | 1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm |
| 55 | 1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm |
| 56 | 1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm |
| 57 | OD135230/2026-2027:Supplying of following modular switch- 5/6 amps switch |
| 58 | OD135229/2026-2027:Supplying following modular switch -15/16 amp switch |
| 59 | OD135228/2026-2027:Supply the following modular switches & accessories (RoHS compliant )25A SP switch with indicator |
| 60 | OD135227/2026-2027:Supply the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 61 | OD135226/2026-2027:Supplying following modular switch/ socket -3 pin 5/6 amp socket outlet |
| 62 | OD135225/2026-2027:Supply the following modular switches & accessories (RoHS compliant )6A universal socket |
| 63 | OD135224/2026-2027:Supplying of following modular switch/ socket -6 pin 15/16 amp socket outlet |
| 64 | OD135223/2026-2027:Supply the following modular switches & accessories (RoHS compliant )25A 3pin Shuttered socket |
| 65 | OD135222/2026-2027:Supply the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )6A 3 pin plug top |
| 66 | OD135221/2026-2027:Supply the following modular switches & accessories (RoHS compliant )16A 3 pin plug top |
| 67 | OD135220/2026-2027:Supply the following modular switches & accessories (RoHS compliant )25A 3 pin plug top with indicator |
| 68 | OD135219/2026-2027:Supplying two module stepped type electronic fan regulator |
| 69 | OD135218/2026-2027:Supplying of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 70 | OD135217/2026-2027:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 71 | OD135216/2026-2027:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 72 | OD135215/2026-2027:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) |
| 73 | OD135214/2026-2027:Supplying following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm) |
| 74 | 1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm) |
| 75 | OD135213/2026-2027:Supplying of following sizes of medium class PVC conduit along with accessories 20 mm |
| 76 | OD135212/2026-2027:Supplying of following sizes of medium class PVC conduit along with accessories 25 mm |
| 77 | OD135249/2026-2027:The annual maintenance contract of 750KVA Cummins make DG set installed at Electrical Control Room, Super Speciality Block ,Medical College Hospital, Thiruvananthapuram covers the preventive maintenance of the DG set carried out by service engineer 6 times in a year (bi-monthly) which includes attending breakdown calls, petty repairs and general check up of Engine, Alternator and control panels. The general check up includes checking of water pump, valves, oil levels, cleaning of filters, filling required quantity of coolant in radiator, arrest the leakage of oil or water if any, checking and cleaning battery terminals, applying petroleum jelly, check the density of electrolyte in battery, check the connections of in built panel, report major components/ spares to be replaced etc and make the DG set in perfect working condition at all times during its operation, removing contaminated oil and filling up of required quantity of Engine oil ,checking and tightening of Turbo clamps, checking and adjustment of belt tension , valve clearance etc. |
| 78 | OD135267/2026-2027:Charges for Inspection, Servicing and Testing of 1000 kVA Transformer including checking the primary and secondary windings, cleaning from dust, dirt, grease and possible foreign bodies using clean dry compressed air, Tightening of the bolts of HV and LT terminals and all electrical connections and tightening of all other mechanical parts etc if required for the proper functioning of the existing transformer including painting the entire outer suraface of the USS with 2 coats of metal paint over a coat of synchromate primer. Inspection, Servicing and Testing must be done in the presence of PWD officers at site by the authorised service agent of the company/firm. |
| 79 | OD135251/2026-2027:Repair and maintenance of HT VCB multi panel (VCB-VCB-VCB) (11kv) by cleaning using CRC, re-lubricating using standard grease all mechanical linkages inspect all breaker parts, remove all covers and arc extinguishing shields, inspect for damage wear and deterioration, checking the tightness of breaker settings, nut and bolts, checking the functional operation of limit switches and TNC and L/R switches, check control plug arrangement & alignment, check operation counter condition. Checking all Mechanical/Electrical ON/OFF operation, manual spring operation, Rack in /Rack out operation, Interlock Check. Testing conducted on equipment to check the contact resistance measurement by injecting 100A DC current, closing and opening time measurement using electronic time interval testing kit, Insulation resistance test via Meggar etc as required |
| 80 | OD135250/2026-2027:Repair and maintenance of ACB by cleaning using CRC, relubricating using standard grease all mechanical linkages inspect all breaker parts, remove all covers and arc extinguishing shields, inspect for damage wear and deterioration check clean and dress (if required) the main contacts, , replacing hardware as per requirements correcting alignment clean all covers and arc shields. Checking all Mechanical/Electrical ON/OFF operation , manual Spring operation , Rack in /Rack out operation , Interlock Check , Auxiliary contacts etc of Legrand make ACB 1000-1600A ACB. |
| 81 | OD135242/2026-2027:Supply and providing Steel work in MS Channels/flats/angle (in single section) cutting, hoisting and fixing in position including painting with 2 coats of enamel paint over a coat of zinc chromate primer. |
| 82 | OD135240/2026-2027:Supply of LED indicator (6 V AC/DC, 12V AC/DC, 24 V AC/DC, 48V AC/DC, 63.5V AC/DC, 110 V AC/DC, 220V DC, 240 V AC), 22.5 mm cut out dia Red, Green, Black, Yellow, Orange colours |
| 83 | OD135241/2026-2027:Supply of LED indicator (6 V AC/DC, 12V AC/DC, 24 V AC/DC, 48V AC/DC, 63.5V AC/DC, 110 V AC/DC, 220V DC, 240 V AC), 22.5 mm cut out dia Blue colours |
| 84 | OD135465/2026-2027:Painting of Metal Panel/cable tray /other metal part in installed position by spray paint machine with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent etc and checking all connections. |
| 85 | OD135235/2026-2027:Supply of Insulation tape pack of 10 nos |
| 86 | OD135236/2026-2027:Supply of Register book having good quality 200 ruled pages |
| 87 | OD142985/2026-2027:Supply of Class 2 (yellow) electrical insulating Gloves packaged in an individual container or package of sufficient strength to protect properly the gloves from damage, conforming to IS 13774/IEC 60903 suitable for working voltage upto 17 K V and shall be marked as per standard. |
| 88 | OD142986/2026-2027:Supply of Class 1 (white ) electrical insulating Gloves packaged in an individual container or package of sufficient strength to protect properly the gloves from damage, conforming to IS 13774/IEC 60903 suitable for working voltage upto 7.5 K V and shall be marked as per standard. |
| 89 | OD135244/2026-2027:Supply of 2A HRC Fuse link |
| 90 | OD135234/2026-2027: Supply of following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 - 3 core 0.75 sq mm |
| 91 | OD139773/2026-2027:Supply and fixing ofSelf-adhesive vinyl sticker for lettering and figures of sizes and colour selected by the Engineer in charge for the identification mark to fan, AC, SB, DB, panel board , fire etc as required |
| 92 | OD135233/2026-2027:Supply of Distilled/Deionized Lead acid battery water (5 Litre Bottle) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender