Tender For Providing Infrastructure Facilities For Additional Eseva Kendra In Combined Court Building C Us At Thanjavur In Thanjavur District
Tender Value
4.15 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
14 days left
EMD
4150
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Thanjavur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Infrastructure Facilities For Additional Eseva Kendra In Combined Court Building C Us At Thanjavur In Thanjavur District
BOQ
| Sl. No. | Item Description |
| 1 | Clean removal of Cement plaster from walls etc., |
| 2 | Labour wrought and put up in position of steel doors inclusive of fixing holdfasts for doors etc., |
| 3 | Earth work excavation for foundation by manual means for Isolated, Combined and Other type foundations in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. |
| 4 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. -Mixing by manual means. |
| 5 | Brick work in following Cement Mortar using best quality Fly ash Brick of size 230x110x70mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing,etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.Foundation and Basement |
| 6 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 7 | Supplying and laying of Interlocking Paver Block Stone 63mm thick Over a base layer of crushed stone sandfilling incl. Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the departmental officers. |
| 8 | Fabricating Supplying and fixing in position of Aluminium anodised powder coated finish 1/3rd fixed glazing 2/3rd prelaminated board of Aluminium partition of size 3.50 x 2.88m. The outer frames Outer frame: 63.50x38x3mm@ 1.72 kg/ m,Centre mullions: 63.50x38x3mm@ 1.55 kg/m,Alu. Clips: 17.27x17.15x1.50mm @ 0.175kg/mg/m for intermediate vertical mullion 90cm c/c. Horizontal mullion at 1.00m 2.10m covered with 5.5mm thick plain glass with neccessary aluminium clips of size 17.27x17.15 x1.50mm @ 0.176kg/m and with required rubber beading etc., including necessary dismantling holes in RCC column,masonry wherever in necessary with power drills to the extent required and made good the damaged portion in good condition after fixing etc... complete complying with standard specification and as directed by the deparmental officers. All the aluminium sections should be anodised not less than 15 microns as ISI specification1868/1962 / and should be gotapproved by Executive Engineer before use. |
| 9 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside.Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam. |
| 10 | Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work). |
| 11 | Painting Old Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 12 | Painting Old Plastered Wall Surface with One finishing coats of ready mixed (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 13 | Painting the wall two coats with approved weather proof Exterior Emulsion paint on cement plastered wall surface ect., complete complying with standard specification and as directed by the departmental officers. |
| 14 | Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with One coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 15 | Supplying and placing in position of Computer Table with ornamental designs. The size of the table shall be 0.90mx0.60mx0.75m with drawer and cupboard on one side. The size of the drawer shall be 0.25mx0.37m and cupboard is 0.30mx0.40m. The computer table was projected with adjustable keyboard tray of size 0.48mx0.30m. The cost includes cost of all materials, labour, conveyance and all other incidential charges. |
| 16 | Supplying and placing in position S type office chair. The size of the seater shall be 0.45mx0.45m and the height for back rest shall be of 0.45mx0.40m. The rate shall be inclusive of cost of all materials, labour, conveyance and all other incidential charges. |
| 17 | AddGST18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysOct 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender