Tender For Repairs/Maint/Replacement To Reinforced Cement Concrete Chajja, Parapets, Window, Railing, Plinth Rwh Alongwith Drain And Cleaning Of Pvc Tanks With Other Connected Works At Np Area 24 Ed Af Stn Manauri
Tender Value
14.90 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
19 days left
EMD
30000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Prayagraj → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs/Maint/Replacement To Reinforced Cement Concrete Chajja, Parapets, Window, Railing, Plinth Rwh Alongwith Drain And Cleaning Of Pvc Tanks With Other Connected Works At Np Area 24 Ed Af Stn Manauri
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and as directred by Engr-in-Charge |
| 2 | Demolistion of brick work built in CM |
| 3 | Taking down cement plaster on brick/concrete surace of wall/ceiling etc |
| 4 | Taking down AC rain water/PVC pipe (any size pattern) including all fittings, including cleaning or refixing or removal to store. OF 110/75mm dia |
| 5 | Dismantling of AC (Corrugated or semi corrugated sheet/PGT/CGI etc.) sheets in roof coverings including ridge all as specified and as directed |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 7 | Taking down steel tubing & connection incl cleaning for refixing or removal to store for 15mm dia complete all as specified and directed |
| 8 | Taking down steel tubing& connection incl cleaning for refixing or removal to store for 20mm d ia complete all as specified and directed |
| 9 | Taking down steel tubing& connection incl cleaning for refixing or removal to store for 25mm d ia complete all as specified and directed |
| 10 | Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified |
| 11 | M&L for PCC 1:2:4 type B0 using 12.5mm graded aggregate as in roof padding/Chajja's curving complete all as sspecified and directed. |
| 12 | Supply and applying high build elastomeric water proofing coating on beam/Column/railing and door/window cill etc based on pure hydrophobic, cold applied spray/brush applied , amart care PU magnum membranne with and elongation of 450% and tensile strength of 2.5 N/Sqmm as per ASTM D 2370. crack bridging ability of 3mm as per ASTM 1305, no leakage upto 7 bars of water pressure as per DIN 1048 shore a hardness of min 45 as per ASTM D 2240. The system includes final base preparation , Epoxy Primer application and applying smart care PU magnum or approved equivalant in two coats with a consumption of 1.5 Kg/Sqm on a primed surface with smart care primer and a 40GSM geo textile cloth sand wiched in between etc. Complete all as per manufacturer instruction/ specification. |
| 13 | Supply only Water proffing liquid compound (ISI Marked) complete all as per specified and directed |
| 14 | M&L for Plain Cement concrete 1:3:6 type C2 using 40mm grqded aggregate as in surfce channel and drain complete all as specifed including form work and as directed by Engr-in-Charge |
| 15 | M&L for Extra for forming fair finished drain or channel 30 CM inner girth in cement concrete, using extra cement, including forms, moulds mitred/stopped ends complete all as specified and directed. |
| 16 | M&L for Extra for forming fair finished drain or channel over 30 CM inner girth in cement concrete, using extra cement, including forms, moulds mitred/stopped ends complete all as specified and directed. |
| 17 | Demolition of Re-inforced cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and as directred by Engr-in-Charge |
| 18 | M&L for pre-cast re-inforced cement concrete as in man hole/open drain cover or etc 1:2:4 type B1 using 20mm graded aggregate complete all as specified and direcged. |
| 19 | Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips |
| 20 | M&L for cement concrete 1:2:4 type B1 (Using 20mm graded aggregate) as in coopings/window Cill complete all as specified and direced. |
| 21 | M&L for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity n. exc 250 Ltr |
| 22 | M&L for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity exc 250 Ltr but n. exc 500 Ltr |
| 23 | M&L for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity exc 500 Ltr but n. exc 1000 Ltr |
| 24 | M&L for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity exc 1000 Ltr but n. exc 2000 Ltr |
| 25 | M&L for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc of capacity exc 2000 Ltr but n. exc 5000 Ltr |
| 26 | Dismantling water tanks and removing to store exc 500 ltr but n. exc 1000 ltr |
| 27 | S&F Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including valve and rod nuts all as specified in SSR Part I of 500 Ltr capacity |
| 28 | S&F Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including valve and rod nuts all as specified in SSR Part I of 1000 Ltr capacity |
| 29 | M&L for 15mm thick rendering in CM (1:3) on edge of RCC chajja or corners of columns where steel reinforcement coming out after fixing 15mm zize wire netting of mild steel wire 1.60mm dia fixed with tinned tacks of wire staples including taking down plaster complete all as specified and directed. |
| 30 | M&L for brick work with sub class 'B' brick straight or curved onplan exc 6 m mean radius built in CM 1:6 |
| 31 | M&L half brick thick wall work with sub class 'B' Brick straight or curved on plan builtin CM 1:4 |
| 32 | M&L 15mm thick in cement plaster 1:4 with WPC @ 3% by weight of cement on fair faces of by weight of cement on fair faces of brick/concrete surface finishing the surface even and smooth without using ezxtracement comp,lete all as specified and directed. |
| 33 | M&L for Rendering 10mm thick in cement mortar (1:6) on brick/concrete surface of wall on fair faces of brick work or concrete surfaces finished even and smooth without using exra cement |
| 34 | M&L for Rendering 5mm thick in cement mortar (1:3) on brick/concrete surface of ceiling l on fair faces , finished even and smooth without using exra cement |
| 35 | M&L for preparation of new surface of wall including cornice and applying two coats of cement base paint over a coat of primer complete all as specified and directed by Engr-in-Charge. |
| 36 | M&L for preparing new plastered surface of wall of any description not otherwise described and applying two coats of oil Bound Distemper over a coat of primer complete |
| 37 | M&L for preparing new plastered surface of Ceiling of any description not otherwise described and applying three coats of white wash complete |
| 38 | S&F 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. fixed with L/J hooks or crancked hook bolt and making goodf to disturb surface etc complete all as specified and directed by Engr-In-Charge |
| 39 | M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 40 | M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 41 | M&L brushing neat cement slurry with 3 Kg of cement /Sqm complete all as specified and directed. |
| 42 | M&L for preparation of roof treatmment of APP polymeric water proffing membrane all as given below:-(a) Taking down existing water proffing treatment and cleaning roof by brushing and rubbing etc and removing retrieved material to a distance n .exc 500 mtr where directed.(b) M&L for plastering 10mm thick in CM 1:3 using 100% coarse asand on roof suface including waater proffing compound as per manufacturer instruction and as directed by Engr-in-Charge.(c ) Applying a coat of bitumenous primer confirming to IS-3384-1986 @ 0.40 Ltr/Sqm and allow to dry.(d) Applying and laying 3mm thick APP membrane having weight 3.2 to 3.50 Kg on prepared susrface as per manufacturer instruction and over laps 10cm and 15cm longitudinal and traverse direection respectively and sealed by flame , sealing all overlaps complete including treatment at all junction and corner. The membrane shall be torched into grooves on vertical plane and groove sealed with cement mortar 1:3(e ) Applying two coats of aluminium paint over membrane @ 0.20 Kg/Sqm and all as per specifiecation and as directed by Engr-in-Charge |
| 43 | S&F AC serrated ridge two pieces adjustable 6mm thick corrugated AC Sheets fixed in positioon complete all as specified and directed. |
| 44 | M&L for 6mm thick polycorbonate sheet of any shape and size including in roof covering and ridge etc complete all as specified and directed. |
| 45 | Repair of velly gutters joints, holes filling with M Seal all as specified and direcged by Engr-In-Charge |
| 46 | S&F in repair PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as directed by Engr-In-Charge |
| 47 | S&F in repair PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as directed by Engr-In-Charge |
| 48 | S&F in repair PVC (SWR) bends 110 mm dia any radius fixed in poaition complete |
| 49 | S&F in repair PVC (SWR) bends 75 mm dia any radius fixed in poaition complete |
| 50 | S&F in repair PVC (SWR) junction single, (Single T) equal or unequal 110mm dia complete all as specifiwed and directed by Engr-In-Charge |
| 51 | S&F in repair PVC (SWR) junction single, (Single T) equal or unequal 75mm dia complete all as specifiwed and directed by Engr-In-Charge |
| 52 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as directed by Engr-In-Charge |
| 53 | M&L for preparation new steel surface of any description not otherwise described over 10cm width or girth and applying two coaats of synthetic enamel paint over a coat of red oxide primer complete |
| 54 | S&F 15mm GI tubing medium grade for flush pipes fixed dto wall, floor, trenches or ceiling complete all as specified and directed by Engr-In-Charge. |
| 55 | S&F 20mm GI tubing medium grade for flush pipes fixed dto wall, floor, trenches or ceiling complete all as specified and directed by Engr-In-Charge. |
| 56 | S&F 25mm GI tubing medium grade for flush pipes fixed dto wall, floor, trenches or ceiling complete all as specified and directed by Engr-In-Charge. Please Enable Macros to View BoQ information |
| 57 | S&F 25mm GI tubing medium grade for flush pipes fixed dto wall, floor, trenches or ceiling complete all as specified and directed by Engr-In-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysOct 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender