Bids Are invited for Mcb 100681
Tender Overview
Project Description
Bids Are invited for Mcb 100681 Motor Protection Circuit Breaker, Type Mog H1, Cat No. St41914o, Thermal Release Range 9 To 13 Eres With 1No And 1Nc Auxiliary Contact Of Cat No. St41945o , Motor Protection Circuit Breaker, Type Mog H1, Cat No. St41909o, Thermal Release Range 1 To 1.6 Eres With 1No And 1Nc Auxiliary Contact Of Cat No. St41945o , Motor Protection Circuit Breaker, Type Mog H1, Cat No. St41911o, Thermal Release Range 2.5 To 4 Eres With 1No And 1Nc Auxiliary Contact Of Cat No. St41945o , Motor Protection Circuit Breaker, Type Mog H1, Cat No. St41913o, Thermal Release Range 6.3 To 10 Eres With 1No And 1Nc Auxiliary Contact Of Cat No. St41945o , Motor Protection Relay, Type Mpr300, Cat No. Mpr304bf160, Over Load Range 16 To 44 S, Coil Voltage 230 Volts Ac, 50 Hz. With 1No And 1Nc Auxiliary Contact - Motor Protection Circuit Breaker, Type Mog H1, Cat No. St41914oooo, Thermal Release Range 9 To 13 Eres With 1No And 1Nc Auxiliary Contact Of Cat No. St41945oooo , Motor Protection Circuit Breaker, Type Mog H1, Cat No. St41909oooo, Thermal Release Range 1 To 1.6 Eres With 1No And 1Nc Auxiliary Contact Of Cat No. St41945oooo , Motor Protection Circuit Breaker, Type Mog H1, Cat No. St41911oooo, Thermal Release Range 2.5 To 4 Eres With 1No And 1Nc Auxiliary Contact Of Cat No. St41945oooo , Motor Protection Circuit Breaker, Type Mog H1, Cat No. St41913oooo, Thermal Release Range 6.3 To 10 Eres With 1No And 1Nc Auxiliary Contact Of Cat No. St41945oooo , Motor Protection Relay, Type Mpr300, Cat No. Mpr304bf160, Over Load Range 16 To 44 S, Coil Voltage 230 Volts Ac, 50 Hz. With 1No And 1Nc Auxiliary Contact
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Motor Protection Circuit Breaker, Type MOG H1, Cat No. ST41914OOOO, Thermal Release Range 9 to 13 Amperes with 1NO and 1NC Auxiliary Contact of Cat No. ST41945OOOO | Motor Protection Circuit Breaker, Type MOG H1, Cat No. ST41914OOOO, Thermal Release Range 9 to 13 Amperes with 1NO and 1NC Auxiliary Contact of Cat No. ST41945OOOO |
| 2 | Motor Protection Circuit Breaker, Type MOG H1, Cat No. ST41909OOOO, Thermal Release Range 1 to 1.6 Amperes with 1NO and 1NC Auxiliary Contact of Cat No. ST41945OOOO | Motor Protection Circuit Breaker, Type MOG H1, Cat No. ST41909OOOO, Thermal Release Range 1 to 1.6 Amperes with 1NO and 1NC Auxiliary Contact of Cat No. ST41945OOOO |
| 3 | Motor Protection Circuit Breaker, Type MOG H1, Cat No. ST41911OOOO, Thermal Release Range 2.5 to 4 Amperes with 1NO and 1NC Auxiliary Contact of Cat No. ST41945OOOO | Motor Protection Circuit Breaker, Type MOG H1, Cat No. ST41911OOOO, Thermal Release Range 2.5 to 4 Amperes with 1NO and 1NC Auxiliary Contact of Cat No. ST41945OOOO |
| 4 | Motor Protection Circuit Breaker, Type MOG H1, Cat No. ST41913OOOO, Thermal Release Range 6.3 to 10 Amperes with 1NO and 1NC Auxiliary Contact of Cat No. ST41945OOOO | Motor Protection Circuit Breaker, Type MOG H1, Cat No. ST41913OOOO, Thermal Release Range 6.3 to 10 Amperes with 1NO and 1NC Auxiliary Contact of Cat No. ST41945OOOO |
| 5 | Motor Protection Relay, Type MPR300, Cat No. MPR304BF160, Over Load Range 16 to 44 Amps, Coil voltage 230 Volts AC, 50 Hz. With 1NO and 1NC auxiliary contact | Motor Protection Relay, Type MPR300, Cat No. MPR304BF160, Over Load Range 16 to 44 Amps, Coil voltage 230 Volts AC, 50 Hz. With 1NO and 1NC auxiliary contact |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender