Tender For Special Repairs To Block No P-226 (Rwa-6) P-16 And P-52 (Rwa-7) At Old Abert Ekka Enclave At 9 Para (Sf) Under Age B/R-I At Ge (South) Udh Ur
Tender Value
1.14 Crore
Estimated cost
Bid Submission
14 Oct 2026
22 days left
EMD
1.90 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Reasi → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs To Block No P-226 (Rwa-6) P-16 And P-52 (Rwa-7) At Old Abert Ekka Enclave At 9 Para (Sf) Under Age B/R-I At Ge (South) Udh Ur
BOQ
| Sl. No. | Item Description |
| 1 | BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: COMMANDER WORKS ENGINEER, UDHAMPUR Name of Work: SPECIAL REPAIRS TO BLOCK NO P-226 (RWA-6) P-16 AND P-52 (RWA-7) AT OLD ABERT EKKA ENCLAVE AT 9 PARA (SF) UNDER AGE B/R-I AT GE (SOUTH) UDHAMPUR Contract No: CWE/U(S)- 67/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work , complete all as specified. |
| 3 | Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 5 | Glazed ceramic tiles in vertical surface 600mm x 300mm x10 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface rendering as backing coat to receive the tiles on fair faces of brick /concrete surfaces in cement mortar 1:3 and finished even and rough complete all as specified and directed. |
| 6 | Non skid, coloured ceramic size 400x400 jointfree/rectified tiles 7mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and as directed. |
| 7 | Non skid, coloured ceramic size 600x600 jointfree/rectified tiles 10mm thick (square/rectangular) area of each tile exceeding 0.18sqm but not exceeding 0.36sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed. |
| 8 | All as per ser item No.6 above but on vertical surfaces as in skirting including 10 mm thick rendering as backing coat to receive the tiles on fair faces of brick /concrete surfaces in cement mortar 1:3 and finished even and rough complete all as specified and directed. |
| 9 | 25 mm thick cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregates) as in floor and finished even and fair complete all as specified and directed. |
| 10 | 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and polishing and moulding on edges complete all as specified and as directed. |
| 11 | Machine cut kota stone slab flooring 20-25 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:4, complete all as specified and as directed. |
| 12 | Machine cut kota stone 20-25mm thick as in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including 15 mm thick rendering in cement mortar 1:4 as in backing coat for laying wall tiles, complete all as specified and as directed. |
| 13 | Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed. |
| 14 | 15mm thick rendering on fair faces of brick surfaces or concrete surface in cement mortar 1.4 finished even and smooth without using extra cement but using integral water proofing compound as per manufacturer,s instructions, complete all as specified.Note : Integral water proofing compound shall be measured & paid seprately. |
| 15 | Rendering 10mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement all as specified and directed. |
| 16 | Rendering 5mm thick on brick or concrete surface as in ceiling in cement mortar 1:3 finished even and smooth without using extra cement all as specified. |
| 17 | Supply only integral water proofing compound, complete all as specifed. |
| 18 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt. ) , all as specified and directed. |
| 19 | Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt. ) , all as specified and directed. |
| 20 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat (Double rebated Chowkhat) of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugsor SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall beacceptable. Variation in profile dimensionson plus side shall be acceptable but no extrapayment on this account shall be made. |
| 21 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat (Single rebated Chowkhat) of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugsor SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames,minus 5mm tolerance in dimension i.e.depth and width of profile shall beacceptable. Variation in profile dimensionson plus side shall be acceptable but no extrapayment on this account shall be made. |
| 22 | Providing cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates for, filling as in the pressed steel door frame/hold fast complete all as specified and directed. |
| 23 | 35mm thick factory made flush shutters, solid core construction, with block board core and plywood face pannels, with both thw face covered with decorative face veneer with liping/frame to match, complete all as specified and directed. |
| 24 | 2nd class hard wood glazed and skelton shutters 35 mm thick open rebated and prepared to receive glass, guage etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Pt-I Section 8.24(a) supplied and fitted to chowkhats complete all as specified and directed. |
| 25 | Supply and fix powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates (minimum thickness of powder coating 50 micron) including joining cleat for fixing etc.complete all as specified and directed. |
| 26 | Powder coating of any colour (Thickness or powder coating not less than 50 micron) anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed. |
| 27 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainlesssteel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction. |
| 28 | 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed. |
| 29 | 4 mm thick figured glass (frosted) ,pin head type and glazing with oil putty not exc 0.50 Sqm in each pane fixing to window/ventilator complete all as specified and as directed. |
| 30 | Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel staples complete, all as specified and directed. |
| 31 | Rolled mild steel work of angle iron as in frames of doors & Cup Board & Iron ladders etc conforming to grade Fe 410-O or Fe-310-O complete all as specified. |
| 32 | S&F Hard Drawn steel wire fabric cut to length bent to shape required and tying,welding to the angle iron frame etc complete all as specified and directed. (weight n.exc 4kg/Sqm). |
| 33 | Dismantling wall & ceiling board (fibre, pulp, insulation etc.) or insulation oards/ slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed. |
| 34 | Providing and fixing flase ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99%, NRCO 0.50 to 0.75 as per IS 8225 : 1987, non combustible as per BS 475 (Part 4)-1970 and light reflectance of 85%(minimum) to be laid in true horizontal level suspended on interlocking metal T Grid of hot dipped galvanized iron section of 0.33mm thick (galvanised @ 120 grams per sqm both sides) comprising of main T runners of size 15 x 32 mm of length 3000 mm, cross T of size 15 x 32mm of length 600 mm x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e 50 mm long, 12 mm outer diameter M-6 dast fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x 0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out as per specificatins, drawing and as per directions of Engr-in-Charge. |
| 35 | 19mm thick ISI, termite proof, chemically well pressed, HDHMR board exterior grade prelaminated, both side with decorative choice lamination fixed with screws to frame work for cupboards etc including 6 mm thick wood beading all around, complete all as specified and as directed. |
| 36 | Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed. |
| 37 | Walling of random rubble stone masonry uncoursed, with best quality locally available stones, well bonded, bedded and solidly hearted , built in cement mortar 1:6 complete all as specified and as directed. (PCC bond stone shall be measured and paid for seperately). |
| 38 | All as per ser item No 36 but except stone complete all as specified and directed. |
| 39 | Extra over stone walling of granite, trap or basalt stone for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc 20mm, complete all as specified & directed. |
| 40 | Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed. |
| 41 | Brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 but except bricks all complete all as specified and as directed. |
| 42 | Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortor 1:4 complete all as specified and as direceted. |
| 43 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed. |
| 44 | Pre painted galvalume aluminium zinc coating GI based corrugated sheets 0.50 mm thick of any colour having tensile strenght of 550/MPA as in roof covering, cladding to wall fixed with self taping screws complete all as specified and directed. Note : Rate quoted by contractor deemed to be included for roof up to height of 10 mtrs. |
| 45 | Pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed. |
| 46 | Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including waste coupling and waste pipe & bedding in CM to dwarf wall or incl fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm incl 32mm waste fittings brass chromium plated etc, fixed in repairs, complete all as specified and as directed. |
| 47 | Plate rack made of stainless stee, 600 x 750X0.55mm including fixing as per manufacturers instruction complete all as specified. |
| 48 | Material and labour for 3mm thick APP based polymeric membrane minimum weighing 3 kg/sqm non-woven polyester reinforcement polymeric water proofing membrane (wt not less than 150 gms/sqm) laid on primed surfaces by gas flame torch application and Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified and as directed.Note :- Water proofing treatment will be done by IWL or through a specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed by engaging local labour. |
| 49 | Material and labour for Applying a coat of bituminous aluminium paint @0.10kg/Sqm as weather proof coat all as specified and as directed |
| 50 | Water proofing treatment to the sunken portion applying two coat of two component (1 part Polymer and second part cementations powder) cementations, polymer modified elastomeric, water proofing coating composed of cement, properly selected and graded aggregates, additive and acrylic emulsion polymer as a binder apply first coat of (mix and application as per manufacturer's instructions) all over floor surface/prepared surface and apply to vertical surface up to 15 cm from tilling level, allow to dry 4 to 6 hours. Prepare for apply 2nd coat perpendicular to first coat and allow to dry 4 to 6 hours. All joints of Trap/WC/Soil pipe shall be Properly sealed with ceiling compound/polymer modified mortar using Dr Fixit Pidicrete URP or equivalent, Slope of slab shall be towards and including GI pipe 50 mm dia of suitable length Spout pipe. Providing 15 mm protective screed with cement mortar in 1.3 with WPC (Make: Dr Fixit LW+ or equivalent) within 2 to 3 days of second coat complete all as specified as per manufacture instructions. Make: Dr Fixit Pidifin 2K or other equivalent make complete all as specified and directed by Engr-in-Charge. Note : Water proofing treatment will be done by manufacturer of acrylic based polymer modified cementitious composite compound or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage,otherwise no payment shall be made to the contractor if water proofing is executed otherwise. |
| 51 | Providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (not exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified. |
| 52 | 300 mm long stainless steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed. |
| 53 | Continuous MS CP piano type hinges 30mm flap (when opened), bright finish or electrogalvanised complete all as specified and directed. |
| 54 | 150 mm stainless steel handles, cast type anodised complete all as specified and directed. |
| 55 | 100mm size hasp and staple safty type aluminum anodized with mild steel hinges pin including bolt to hinge plate and fixed with screw complete all as specified. |
| 56 | 150 mm stainless steel anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 57 | 100 mm long extruded brass handles, fabricated type polished, complete all as specified and as directed. |
| 58 | 2nd class hard wood small fittings such as shaped door & window stops, cleat including all necessary labours, articles not exceeding 200 cubic centimeter each fixed in repairs complete all as specified and directed. |
| 59 | stainless steel butt hinges (ISI Marked) 'Medium weight' 100 mm size, fixed to steel/angle iron frame by welding , if required complete all as specified and directed. |
| 60 | 250mm mild steel rat tail rod pattern including roller and roller plate fixed to wooden or steel frames with welding etc. complete all as specified and directed. |
| 61 | Stainless steel chromium plated curtain rod cut to size 25 mm dia with holder/bracket, stops, rollers etc. complete fixed in repairs complete all as specified and directed. |
| 62 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed. |
| 63 | Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck in side with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed. |
| 64 | S&F in repair wash hand basin of size 550 x 400 mm vitreous China white padestel type including brackets brass chromium plated waste coupling, pillar tap & PVC waste pipe of 32 mm dia etc complete all as specified. |
| 65 | 600mmx450mm beveled edge mirror 5.5mm thick of selected quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, fixing in repairs, complete all as specified and directed. |
| 66 | Preparation of new wooden surfaces over 10 cms width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 67 | Preparation of new steel and iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over preprimed surfaces, complete all as specified and as directed. |
| 68 | Applying two coats of white washing on ceiling including preparation of new/old plastered surfaces complete all as specified and as directed. |
| 69 | Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty including preparation of old plastered/ unplastered surfaces of wall, including complete removal of existing treatment complete all as specified & directed. Note:- (Bfore applying of wall care putty, complete removing of treatment complete all as specified & directed). |
| 70 | Material & Labour for prepration of complete removal of old decorated surfaces of walls including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil, greasy spots and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified & directed. |
| 71 | Vitreous China wash down water closet pan and seat cover (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including P or S trap and including plastic seat cover water closet seat, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, fixed in repairs complete all as specified and as directed. |
| 72 | 10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete all as specified and as directed. |
| 73 | Supply only flush pipe of PVC 32 mm dia for low level cistern complete all as specified and directed. |
| 74 | Grating round 100 mm size dia fixed in repair to floor trap complete all as specified and as directed. |
| 75 | Fancy towel rail 600mm long, brass chromium plated, complete all as specified and as directed. |
| 76 | PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. |
| 77 | S&F Steel Peg set colour coated of six as per sample complete all as specified and as directed. |
| 78 | M&L PCC 1:5:10 type E2 using 40 mm graded brick aggregate as in filling under sunken floors etc complete all as specified. |
| 79 | Dismantling cast iron pipe & reinforced concrete drain pipes, jointed in cement mortar of any dia taking out from trenches or fixed to wall upto 100mm complete all as specified. |
| 80 | 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 81 | 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 82 | 110 mm bore PVC SWR bends and fixed with joint sealent etc, complete all as specified and as directed. |
| 83 | 75 mm bore PVC SWR bends and fixed with joint sealent etc, complete all as specified and as directed. |
| 84 | PVC SWR branch piece , single (single Y) equal or unequal 110 mm size fixed with joint sealent etc complete all specified and as directed. |
| 85 | PVC SWR branch piece , single (single Y) equal or unequal 75 mm size fixed with joint sealent etc complete all specified and as directed. |
| 86 | 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and as directed. |
| 87 | 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal, complete all as specified and as directed. |
| 88 | PVC (SWR) reducers for 100mm bore, complete all as specified and as directed. |
| 89 | PVC (SWR) `P' Trap for 110mm bore pipe, complete all as specified and as directed. |
| 90 | 75mm Cast iron floor traps with grating including jointing to waste pipe fixed concrete type B1 (1:2:4). complete all as specified and as directed. |
| 91 | Reinforced cement concrete 1:2:4 (Nominal mix) type B-1, using 12.5mm graded crushed stone aggregates as in chajjas, slab or similar works complete all as specified and as directed. |
| 92 | TMT mild steel bars, 8mm to 10mm dia, as in Stirups etc, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) complete all as specified and as directed. |
| 93 | Taking up or down steel tubing with connections for cleaning for refixing or removing to store yard complete all as specified of the following description :- |
| 94 | 15 mm bore |
| 95 | 20 mm bore |
| 96 | M&L 15/20mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls and or laid under floors etc complete all as specified. |
| 97 | 15 mm bore |
| 98 | 20 mm bore |
| 99 | M&L 15/20mm bore galvanised steel water tubing medium grade (ISI Marked) with all fittings and fixed complete to walls and or laid under floors etc complete all as specified. |
| 100 | Except GI Steel tubing 15 mm bore |
| 101 | Except GI Steel tubing 20 mm bore |
| 102 | Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm complete all as specified and as directed. |
| 103 | Gun metal globe of gate valve with iron wheel head, screwed both ends of size 15mm complete all as specified and as directed. |
| 104 | Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed. |
| 105 | Bib taps, cast copper alloy, screwed down, fancy type, chromium plated, screwed for iron pipe or brass ferrule for 15mm bore of pipe, complete all as specified and directed. |
| 106 | Stop valves, but fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions chromium plated of size 15mm and fixed in repairs complete all as specified and directed. |
| 107 | Shower rose, brass, chromium plated, 125mm dia with or without swivel joint, with & including CP brass arm and wall flange, fixing to steel pipe or union as fixed in repairs, complete all as specified and directed. |
| 108 | S&F in repairs WHB mixer, fancy type cast copper alloy with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm , all as specified and directed. |
| 109 | Glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed. |
| 110 | Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, complete all as specified and as directed. |
| 111 | Soap dish, brass, chromium plated, heavy duty, fixed to wall with plugs with brass cromium plated screws, fixed in repair complete all as specified and directed. |
| 112 | S & F in repairs 15 mm dia Sink mixer chromium plated screwed down highpressure with crutch or butterfly handle screwedboth ends for iron pipes or for unions and fixed complete all as specified and as directed. |
| 113 | Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) un-reinforced, complete all as specified. |
| 114 | Hard core of gauge exc 63mm but not exc 100mm using broken stone or boulders, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface, complete all as specified. |
| 115 | Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in foundation, filling and mass concrete, complete all as specified and as directed. |
| 116 | Sand cushioning 30 to 40 mm thick for laying and fixing interlocking tiles, complete all as specified. |
| 117 | Machine pressed / vibro mechenically floated interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 80mm thickness, M-35 Grade, with topping of cement without pigment. Shape shall be approved by GE. |
| 118 | Demolition and breaking up drain pipes,150/200mm dia bore pipe (Salt glazed stone ware, AC or Reinforced concrete) all as specified and as directed. |
| 119 | Brick work with sub-class 'B' bricks in one brick thick honey comb walling, built in cement mortar 1:6 complete all as specified and directed. |
| 120 | Excavating over area, exceeding 1.5 m depth; for foundation, etc. and getting out in any type of soil, complete all as specified and as directed. |
| 121 | Excavation in trenches n.exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5m in depth in any type of soil and getting out, complete all as specified and as directed. |
| 122 | Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil,complete all as specified and as directed. |
| 123 | Removing excavated material exc. 250m but n exc 500m depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed. |
| 124 | Brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, complete all as specified and as directed. |
| 125 | Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 126 | Plain cement concrete 1:2:4, nominal mix, type B1, using 20mm graded crushed stone aggregate as in surface channel and drains, complete all as specified. |
| 127 | Precast cement concrete 1:2:4 type B-1 (20mm graded) as in manhole cover slab and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed. |
| 128 | Mild steel framed work as in frames to manhole covers of angle iron or other section including holdfast conforming to Fe-410-O complete all as specified and as directed. |
| 129 | TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed. |
| 130 | All as per srl item No. 122 above but 5mm dia and over including 10mm dia in stirrups, spaces and binders etc all as specified. |
| 131 | Plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregates) as in steps, seismic and other similar bands, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, cills, lintels upto 1.50 metre clear span, copings etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form works, all as specified and directed.. |
| 132 | 200mm dia Reinforced concrete pipes bore ,class NP2, laid and jointed complete with coller all as specified and as directed. |
| 133 | M&L for Plain cement concrete 1:4:8 type D-2 using 40mm graded aggregate as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore pipes all as specified.(Note- thickness of bed below the barrel of pipes 15 cm and width of bed : Outer diameter of drain pipes (not of sockets/collars) plus 30 cm all as specified and as directed. |
| 134 | Salt-glazed stoneware drain pipe, internal dia of pipe 150mm, laid in trenches and jointed & tested, complete all as specified. |
| 135 | Plain cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes all as specified. |
| 136 | Reinforced cement concrete 1:2:4 (Nominal mix) type B-1 (using 20 mm graded crushed stone aggregate) as slabs supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 137 | 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 138 | 10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified and as directed. |
| 139 | Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work exc 15 cm but n exc 40 cm in width or girth; including cutting to edges, all mitres and stopped ends, etc. complete all as specified and as directed. |
| 140 | Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in coping, benching and similar work etc including necessary form work complete all as specified and as directed. |
| 141 | Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket,fan regulators any type, rectangular board ,light fittings,terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as directed. |
| 142 | Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and directed. |
| 143 | Taking down Old/ Unserviceable MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and directed. |
| 144 | Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLSH copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (size not less than 20mm dia), medium grade with Modular sunken boxes & PVC/Metal back plate for mounting modular type switches, sockets & regulators etc with cover plate modular type including supplying and laying PVC insulated and stranded unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire connected to earth dolly including cutting of chases in wall / ceiling etc and making good the disturbed surfaces match to existing with cement mortar and putty white/ colour wash complete all as directed . |
| 145 | All as per Item No.137 But for one light point control by two nos two way switches with other Independent Board with 1.5 sqmm PVC insulated unsheathed FRLSH copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed FRLSH copper conductor as earth lead complete all as specified & directed . |
| 146 | All as per item no 137 above but cable 2.5 sqmm FRLSH for one 3/5 pin 6 Amp socket outlet point on an independent board. |
| 147 | All as per item no 137 above but cable 2.5 sqmm FRLSH for one 3/5 pin 6 Amp socket outlet point on the same board with other switch. |
| 148 | All as per Srl item No 137 but for 3/5 Pin 16 Amps socket outlet independent board with cable 2.5 Sqmm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly. |
| 149 | All as per Srl item No 137 but for 3/5 Pin 16 Amps socket outlet independent board with cable 4 Sqmm including copper PVC insulated PVC unsheathed suitable earth wire standard and connected to earth dolly. |
| 150 | S&F for modular switch 10 Amps single pole two way 230 V, 50 Hz, AC , with inner / outer cover required module complete all as specified and directed by Engr In charge. |
| 151 | S&F for modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with inner / outer cover required module complete all as specified and directed by Engr In charge. |
| 152 | S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with inner / outer cover required module complete all as specified and directed by Engr In charge |
| 153 | S&F modular Bell push flush type 6 amp 230 V, 50 Hz, AC , with inner / outer cover required module complete all as specified and directed. |
| 154 | S&F for modular socket 3/5 Pin 6 Amps flush type 230 V, 50 Hz, AC , with inner / outer cover required module complete all as specified and directed. |
| 155 | S&F for modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with inner / outer cover required module complete all as specified and directed. |
| 156 | Electronic step type fan regulator (modular) upto 100 watt 230 volts, 50 Hz two moule C/S deluxe type, complete all as specified and directed. |
| 157 | Ceilling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed. |
| 158 | S&F calling Bell ding dong 230 volts single pole 50Hz complete all as specified and directed. |
| 159 | Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed. |
| 160 | MCB, single pole & neutral, 240 volt, 10KA, 'C' curve, 40 amp to 63 amp, complete all as specified and directed. |
| 161 | MCB, single pole, 240 volt, 10KA, 'C' curve, 6 amp to 32 amp, complete all as specified and directed. |
| 162 | S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in existing concealed /on wall conduit /casing capping 25mm dia including PVC insulated copper conductor cable 6 Sqmm as earth lead all as specified. Including taking down old sub main wire. |
| 163 | S&F Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2.5 Sqmm in existing concealed /on wall conduit /casing capping 25mm dia including PVC insulated copper conductor cable 2.5 Sqmm as earth lead all as specified. Including taking down old sub main wire. |
| 164 | Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x6.3 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized steel earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC 1:2:4 type B-1using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion. Note: Excavation earthwork charcoal PCC pit is covered under this item including taking out existing earth plate etc.Note: if earth resistance of earthing is not found (2 to 5 Ω) satisfactory if will be redone by the contractor on his risk and cost. |
| 165 | Taking down ceiling fan/Exhaust fans (C/F of any size/make), cleaning its dust particles oiling,greasing,one coat of synthetic enamel white spray painting with blade ,reassemble the same along with all fittings and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring all as specified and as directed by Engr-in-Charge.Note :- (i) The spares like condensor, ball bearing, cotter pin, nuts & bolts, connecting rods & hooks etc if found defective/damage deemed to be replaced and make the ceiling fans functional. No extra payments will be done on this account. |
| 166 | S&F in replacement Angular Lamp holder, PVC/ Polycarbonate type with cord grip cap suitable for light fittings complete all as specified and as directed. |
| 167 | Supply and fixing replacement LED Bulb 15W, 230V, AC suitable for Angular Lamp holder complete all as specified and directed. |
| 168 | Supply and fixing replacement LED lights fitting 1x 20W, 230V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 169 | S & F replacement LED light fitting 1X9W/10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 170 | Supply and fixing replacement LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 171 | Refixing of 20W LED light fitting any type/ any wattage connected with 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-Charge. |
| 172 | S & F in replacement LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 173 | S&F Street light Bracket complete made of GI pipe of suitable size, medium grade 1.2 m long bent to shape as per site requirement along with MS flat iron clamps with nuts, bolts, washers including grouting the same with wall, all as specified and directed by Engg- in Charge. |
| 174 | Supply, laying, jointing, testing and commissioning aluminium conductor, XLPE Insulated screened PVC bedded galvanized steel strip or wire armoured electric power, cable (heavy duty), 1100 volts grade in trenches/on floor or passing through pipe/ under road including testing of passing through pipeor on pole or on wall or crossing the road, for cross section area of cable 16Sqmm 4 core, complete all as specified and as directed. |
| 175 | Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed. |
| 176 | S&F Double Walled corrugated DWC Pipe of size 40 mm including snap fit coupler Pt-II for protection of LT Cable in underground all as specified. |
| 177 | GI tubing light grade 40mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles, complete all as specified and as directed. |
| 178 | Removing and refixing of Electric water heater, storage type 25 litre capacity, 220V, Ac, single phase icluding nuts bolt, complete all as specified and as directed. |
| 179 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 250m sweep with, blades, and frame and louvers complete all as specified and as directed. |
| 180 | Takingdown existing prepaid meter & Display unit alongwith conduit pipe dia 25mm qty approx 09 RM, casing caping pipe size 20mm qty approx 2 RM & 6 core (RJ-11) qty approx 11 RM from each qtr and refixing the same back to its original position incl. connecting the 6 core control cable (RJ-11) from prepaid meter to display unit complete all as specified and as directed by Engr-in-Charge. |
| 181 | Supply, fixing and testing of meter box board made out of 2mm thick MS sheet of size not less than 1000x1000x150mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, wall mounted/ semi grouted in wall with locking arrangement and provision of tapping for incoming and outgoing electric connections with suitable size of lugs complete all as specified and directed comprising of the following(Make: LT panel shall be manufactured by one make mentioned in the List of makes under PS) :- (i) Aluminium bus bar chamber of 200 amps rating (Set of four strip). (ii) Phase indicating lamp Set of three. (iii) Voltmeter (0-450V), three phase, digital type with inbuilt selector switch-01 set(iv) Ammeter (0-100 Amps) three phase, digital type with inbuilt selector switch incl CT's - 01 set(v) MCCB four pole 415 volts AC 50 Hz, 63 amps rating breaking capacity 10 KA fixed magnetic and adjustable thermal release - 01 No. (vi) MCB two pole 230 volts AC 50 Hz, 40 amps rating breaking capacity 10 KA fixed magnetic and adjustable thermal release - 04 No. (vii) fixing and connection of existing energy meter - 04 nos(viii) Name slip holder on each compartment for identification of Accn - 04 Nos(ix) Earthing terminals - 02 Nos(x) MCB SP 20A 10 KA C series - 01 Nos Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender