Power Boards / Undertakings / PSU Closing in 23 days TDR #57535763

Tender For Construction Of New 400/132Kv Umrangshu Grid Substation Along With Associated Transmission System At Dima Hasao District, Assam.

Issued by Boards / Undertakings / PSU · Dima Hasao, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Oct 2026
23 days left
EMD
11.20 Crore
Bank guarantee accepted
Document Fee
30000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dima Hasao → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of New 400/132Kv Umrangshu Grid Substation Along With Associated Transmission System At Dima Hasao District, Assam.

BOQ

Name of Work:- Construction of new 400/132kV Umrangshu Grid Substation along with Associated Transmission System at Dima Hasao District, Assam.
Sl. No. Item Description
1Supply of Isolators, with both manual and motor driven operating mechanisms along with Support Insulators, clamps & connectors as required and as per spefication
2145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
3145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
4145KV, 3150A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
5145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Tandem Isolator
672.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch.
772.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch.
8Supply of Isolator mounting structures, foundation bolts, nuts bolts etc. as required. and as per spefication
9145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
10145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
11145KV, 3150A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
12145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Tandem Isolator
1372.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch.
1472.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch.
15Supply of insulator string assembly with antifog insulators and hardware fittings complete set with nuts bolts, clamps and other accessories as required. and as per spefication
16400kV, 4X160kN Quad tension string suitable for Quad Moose conductor.
17400kV, 2X160kN Double tension string suitable for Single Moose conductor.
18400kV, 2X120kN Double suspension string suitable for Quad Moose conductor.
19132kV, 2x90kN double tension string suitable for Single AAAC Panther conductor.
20132kV, 2x120kN double suspension string suitable for Twin MOOSE conductor.
21132kV, 2x160kN double tension string suitable for Twin MOOSE conductor.
22132kV, 2X120kN Double suspension string suitable for Quad Moose conductor.
23132kV, 4X160kN Quad tension string suitable for Quad Moose conductor.
24Supply of Conductors, Clamp Connectors as required and as per spefication
254'' IPS Aluminium Tubular Conductors (Schedule 40) with flexi connectors, expansion joints, T- joints, end caps etc as required.
26ACSR Moose Conductor as per site requirement
27Clamps & Connectors as per requirement
28Supply of 1 phase Solid core bus post insulator with creepage distance 31mm/kV including clamp connectors and other accessories as required and as per specification
29420KV, BPI
30145KV, BPI
3172.5KV, BPI
32Supply of bus post insulator support structures, foundation bolts, nuts & bolts and other accessories as required. and as per specification
33420KV, BPI
34145KV, BPI
3572.5KV, BPI
36Supply of Station Service Transformer (Energy efficiency level-3) and accessories as per specification.
37630 KVA, 33/0.4kV StationTransformer, including Terminal Clamps & Connectors.
38440V MCCB with Power receiving Panel as per scheme requirement (with structure, if applicable) for 630KVA Station Service Transformer
39Supply of Surge Arrester complete with Surge Counter, leakage current meter, clamps & connectors and other accessories as required and as per specification
40398kV, 20kA, LA
41120kV, 10kA, LA
4260kV, 10kA, LA
43Supply of Surge Arrester support structures, foundation bolts, nuts bolts etc as required and as per specification.
44398kV, 20kA, LA
45120kV, 10kA, LA
4660kV, 10kA, LA
47Supply of CVT and Pedestal Mounted Wave Trap complete with support insulators, hardware fittings, clamps & connectors, Junction Box and other accessories as required and as per specification.
48400kV, 8800pF, 3 Wdg CVT.
49132kV, 4400pF, 3 Wdg CVT.
50400KV, 3150A Wave Trap
51132KV, 800A Wave Trap.
52Supply of CVT pipe/Lattice support structure, foundation bolts, nuts bolts etc as required and as per specification.
53400kV, 8800pF, 3 Wdg CVT.
54132kV, 4400pF, 3 Wdg CVT.
55Supply of outdoor AIS Circuit Breaker along with clamps & connectors, support structures, foundation bolts and all other accessories as required and as per specification.
56145kV, 3150A, 40kA for 3 sec.
5772.5kV, 1250A, 40kA for 3 sec.
58Supply of Bay Marshalling Kiosk alongwith support structures, foundation bolts and all other accessories as required and as per specification
59400kV BMK
60132kV BMK
61Supply of CT & PT alongwith junction box, clamps & connectors and other accessories as required and as per specification
62132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
63132kV, 1600-800/1-1-1-1-1 (0.2S-PX-PX-PX-PX); 1 ph CT for 315MVA trafo bay
64132kV, 3000-1600/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for Bus coupler bay
6572.5kV, 50-25/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for transformer tertiary bay
66132kV, Potential Transformer (3 wdg, 0.2-3P-3P)
6772.5kV, Potential Transformer (3 wdg, 0.2-3P-3P)
68Supply of CT/PT support structures, foundation bolts, nuts bolts etc as required and as per specification.
69132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
70132kV, 1600-800/1-1-1-1-1 (0.2S-PX-PX-PX-PX); 1 ph CT for 315MVA trafo bay
71132kV, 3000-1600/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for Bus coupler bay
7272.5kV, 50-25/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for transformer tertiary bay
73132kV, Potential Transformer (3 wdg, 0.2-3P-3P)
7472.5kV, Potential Transformer (3 wdg, 0.2-3P-3P)
75Supply of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 400kV GIS
76400kV Bus Bar Protection Panel
77400kV Line CRP
78400/132kV ICT CRP (315MVA)
79400kV Bus Reactor CRP
80400kV Tie Breaker CRP
81Supply of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 132kV AIS
82132kV Line CRP (with line differential)
83400/132kV Transformer CRP (315MVA)
84132kV Bus Coupler CRP
85132kV Bus Bar CRP
86Supply of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 72.5kV AIS
87Station Service Transformer control & Protection Panel
88Relevant software for relay configuration & setting, maintenance etc.
89Supply of Phasor Measurement Unit as required and as per specification.
90Phasor Measurement Unit
91Supply of Complete Substation System Automation System (As per specification)
92Station HMI (Main, Redundant and Metering) with Industrial PC
93Maintenance HMI (DR Workstation) with Industrial PC
94Gate way with PLCC and Fibre Optic Modem and Panel
95SAS Inverter (5kVA)
96Colour Laser MFM Printer
97GPS Clock System
9816 port Ethernet Switch
99All interphase equipment for Gateway to SLDC
100VDU 75 inch
101Aux BCU with panel as per scheme requirement
102All other accessories like FO armoured cables, HDPE Conduit/GI conduit Patch cords,furnitures for HMIs and printers, cables etc as per requirement
103Station Ethernet Switch
104SAMAST compliant ABT meters including DCU, modems, FO cables and other related accessories etc.as per specification.
105Red Box
106Integration of the PMU and the Meters with the PDC, CDCS
107Supply of 400 kV GIS Equipment as per specification.
1083- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Line bay Module as per technical specification
1093- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Transformer bay Module with CSD as per technical specifcation
1103- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Tie bay Module without CSD as per technical specification.
1113- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Tie bay Module with CSD as per technical specification.
1123- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Bus Reactor bay Module with CSD as per technical specification
1133- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Bus bar Module each enclosed in bus bar enclosures running along the length of the switchgear to interconnect each of the circuit breaker bay modules in One and Half breaker configuration as per technical specification alongwith Extension module with all necessary arrangements for future extension of the GIS in One & Half Breaker Arrangement.
114400kV, 63kA for 3 sec, SF6 to Air Bushing along with termination module & support structure for outdoor connections to connect GIS with 400kV side of Power transformer, bus reactors and overhead lines.
115400kV, 63kA for 3 sec, SF6 Gas Insulated Bus Duct (GIB) single phase from respective GIS bay module up to SF6 to Air bushings including required support structures, jointing elements and other accessories for Transformer bays, line bays and bus reactor bays as per site requirement. (for both indoor and outdoor of GIS)
11610 Ton EOT Crane for 400kV GIS Building
117Scissor Lift
118Supply of Testing And Maintenance Equipment of GIS as specified.
119SF6 Gas Processing, Drying, Storage & Filling Unit
120SF6 gas quality testing unit
121SF6 Gas Leak Detector
122SF6 gas Mask
123Supply of 315MVA, 400/132/33kV, ONAN/ ONAF/ODAF or ONAN/ONAF1/ONAF2, ICT along with all accessories and below: (including terminal connectors and other acessories as per technical specification)
124315 MVA, 400/132/33 kV, Three phase Transformer with OLTC & Oil
125Oil & winding temperature monitoring system (FO based)
126Online DGA (Multi gas)
127Online insulating drying system
128Maintenance free breather
129RTCC Panel with AVR (TMS)
13010% Extra OIL for each transformer
131Rail track for transformer
132Pulling block for transformer
133Supply of 80 MVAR Bus Reactor (with Oil) as per specification.
13480 MVAR, 420KV, 3 Phase, Star with Neutral brought out, ONAN coreless Bus Reactor along with Marshalling Kiosk with accessories etc as per technical specification with 10% spare oil
135Pulling block for reactor
136Supply of Battery & Battery Chargers, DCDB & ACDB as per specification
137220V VRLA Battery 1600AH
138220V, Dual Float Cum Boost Chargers for 220V Battery 350A
139220V, DCDB
14048V VRLA type Battery Bank 600AH
14148V, Dual Float cum Boost Chargers for 48V Battery 130A
14248V, DCDB
143Main ACDB
144Sub ACDB
145MLDB with 415V/415V, 100kVA isolation transformer
146ELDB with 415V/415V, 50kVA isolation transformer
147HVAC DB
148MCBDB
149Aux ACDBs, Sub DCDBs etc, as per requirement
150Supply of Power Line Carrier Communication Equipments as per specification
151HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
152Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 200 km) for 400kV
153Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 100 km ) for 132kV
154IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 200 km(400kV)
155IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 50 km(132kV)
156LMU and LMDU
157EPAX system and telephone system with redundant power supply card and CPU along with E1 interface card.
158CAT 6 armoured cable.
1592 wire telephone set
160Audio Cable
161Supply of OPGW equipments as per specification as per specificationTransmission Equipment & SDH Equipment -STM16(ADM- up to five Direction)
162Base Equipment (Common Cards,Cross Connect/Control Cards,Optical base cards,Power supply cards,power cabling,other hardware & accessories including sub-racks,patch cords,DDF etc fully equippped with redundant Control Cards, Optical Base cards, Power Supply Cards (excluding Sl. No. 28 & 29 below.)
163Supply of OPGW equipments as per specification as per specificationOptical Interface/SFP for:
164SFP to support STM-4 upto 150km.
165SFP to support STM-16 upto 150km.
166Supply of OPGW equipments as per specification as per specificationTributary Cards
167E1 interface card (Minimum 63 interfaces per card)
168Ethernet interfaces with minimum of 10/100/1000Mbps configurable with Layer-2 switching (Minimum 8 interfaces per card)
1698 Port VOIP for remote locations
170Analog Telephone( 2-wire telephone for VOIP Gateway location)
171IEEE C37.94 (4 interfaces) to E1 converter/interface for intergration with SDH equipment
172Supply of OPGW equipments as per specification as per specificationEquipment Cabinets with power distribution Circuit breakers, Fan Cable Tray Cable glands entry from Top and bottom
173For SDH equipment(including DDF patching facilities and other accessories
174Main Distribution Frame(100 pairs)
175Supply of OPGW equipments as per specification as per specificationCraft Terminal
176Hardware (LAPTOP)
177Software
178Pre connectorized optical patch cords(Minium 8 patch cords per station)
179Firewall with deep inspection for IEC 104, IEC 61850 ,IEC 62443 certified with 5 years warranty
180Time synchronisation clock (MTCTE certified with multiband receiver) with all other accessories, cables etc.
181Supply of XLPE Armoured, LT Power Cable (1.1kV grade) as per specification
1822C, 6sqmm Cu
1834C, 16sqmm Cu
1843.5C, 35sqmm Al
1851C, 150sqmm Cu
1863.5C, 70sqmm Al
1873.5C, 150sqmm Al
1883.5C, 400sqmm Al
189Cable supports and other cable accessories
190Others ( Cable for Fire Fighting, Illumination etc)
191Supply of PVC Armoured Cu LT Control Cable (1.1 kV grade) as per specification
1924C, 2.5sqmm
1935C, 2.5sqmm
1947C, 2.5sqmm
19512C, 2.5sqmm
19617C, 2.5sqmm
19719C, 2.5sqmm
198Cable supports and other cable accessories
199Supply of Main earth mat conductor, GI risers, treated /Untreated earth pit, equipment earth connections etc.
20040 mm Dia MS Rod for Main/Auxiliary Earthmat
201Earthing Conductor: 40 Mm Dia MS Rod For Riser From The Burial Earth Mat To Equipment,Structure, Fence Etc)
202Earthing Conductor: 75X 12 Mm GS (HDG) Flat For equipment and structure earthing
203Earthing Conductor: 50X10Mm GS(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
204Earthing Device & Associated Accessories (50 Mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI Cover.
205Earthing Device & Associated Accessories 40Mm dia MS Rod 3 Mtrs Long For Non Treated Earth Pit with CI Cover.
206Soil Resistivity Test And Soil Treatment As And When Required
207Separate Earthing For 400 kV GIS modules with multipoint earthing (with Cu flat of adequate size for GIS earth mat)
208Separate Earthing For 400 kV GIS Building with earth electrodes & Copper earthing conductors etc. complete with all respects
209Separate Earthing for all other switchyard buildings, fencing etc. with earth electrodes, GS earthing conductors etc. complete with all respects
210Supply of Mild Steel (Galvanised) Lattice structures for incoming and outgoing gantries etc as required complete with foundation bolts, fastners etc.
211400kV Columns with peak
212400kV Beams
213132kV Columns with/without peak
214132kV Beams
215Supply of Fire Alarm & Detection including all accessories as per specification
216Fire Alarm & Detection system for 400kV GIS Buildings, Control Room , Panel Room, DB room, Battery Room including Fire Alarm panel, Multi Sensor detector, Smoke detector, manual Call point, Hooter, Response Indicators, Beam Detector, Cabling, ISOLATING MODULE etc.
217Portable and wheel/trolley mounted Fire Extinguishers for Control Room Building and Switchyard as per specification and Portable Fire Extinguisher for 400kV GIS Hall each (5kg X 6 Nos),Control room (2kg X 6 Nos), Security Barrack (2kg X 6Nos),Guard room (Security Booth) (2kg X 3Nos), Switchyard (5kg X 4Nos) ( as per specification.
218Dry powder chemical type 10 kg. For 630 kVA transformer
219Fire fire fighting system (sprinkler system) for control room as per requirement
220Supply of HVAC & VENTILATION
2212 TON CAPACITY SPLIT AIR CONDITIONING UNITS for CRP/PLCC/DB Room with N+1 requirements
222Ventilation system for 400kV GIS Building (Ventilation System with Centrifugal Fan and related Accessories should comprise of Pre and Fine air filter,Air Purifier, centrifugal fan, ducting network, air supply grilles, gravity dampers, electrical and instrumentation etc.)
223Supply of Hydrant & HVWS (High Velocity Water Spray) system/NIFPES including all accessories as per specification.
224Hydrant system along with pumping arrangement & associated Civil works for fire protection system
225HVWS system (automatic emulsifier and manual hydrant point both) for 315 MVA ICT-2 No’s and 80MVAr Bus Reactor -2 nos.
226NItrogen injection Fire protection and emergency service with complete accessories and related Civil and Electrical works for 315MVA ICT-2 No’s, 80MVAR Bus reactor-2 nos.
227250 KVA, silent type DG Set with AMF including Panel & all accessories and including earthing arrangement alongwith outdoor distibution board as per scheme requirement.
228Lighting System Supply of Outdoor Lighting
229Outdoor LED lighting for Approach road, Switchyard area, Colony area, Road area, Car parking, Security outpost, open store shed, Bore and OHT area, etc, including Lighting panel, Cabling, street lighting, Switches, Distribution boards, Socket, auxiliary receptacle, complete with GI Poles etc.
230Supply of Public Addressing System & CCTV complete with all accessories as per specification.
231Public Addressing System & CCTV complete with all accessories as per specification.
232Supply of Lightining System
233Lightning protection system LCLM (lightning masts 50 metres high, Lightning Spike, shield wire(7/4mm GI Shield wire), down conductors etc.) for complete substation.
234F&I of Isolators, with both manual and motor driven operating mechanisms along with Support Insulators, clamps & connectors as required and as per spefication
235145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
236145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
237145KV, 3150A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
238145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Tandem Isolator
23972.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch.
24072.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch.
241F&I of Isolator mounting structures, foundation bolts, nuts bolts etc. as required. and as per spefication
242145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
243145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
244145KV, 3150A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
245145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Tandem Isolator
24672.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch.
24772.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch.
248F&I of insulator string assembly with antifog insulators and hardware fittings complete set with nuts bolts, clamps and other accessories as required. and as per spefication
249400kV, 4X160kN Quad tension string suitable for Quad Moose conductor.
250400kV, 2X160kN Double tension string suitable for Single Moose conductor.
251400kV, 2X120kN Double suspension string suitable for Quad Moose conductor.
252132kV, 2x90kN double tension string suitable for Single AAAC Panther conductor.
253132kV, 2x120kN double suspension string suitable for Twin MOOSE conductor.
254132kV, 2x160kN double tension string suitable for Twin MOOSE conductor.
255132kV, 2X120kN Double suspension string suitable for Quad Moose conductor.
256132kV, 4X160kN Quad tension string suitable for Quad Moose conductor.
257F&I of Conductors, Clamp Connectors as required and as per spefication
2584'' IPS Aluminium Tubular Conductors (Schedule 40) with flexi connectors, expansion joints, T- joints, end caps etc as required.
259ACSR Moose Conductor as per site requirement
260Clamps & Connectors as per requirement
261F&I of 1 phase Solid core bus post insulator with creepage distance 31mm/kV including clamp connectors and other accessories as required and as per specification
262420KV, BPI
263145KV, BPI
26472.5KV, BPI
265F&I of bus post insulator support structures, foundation bolts, nuts & bolts and other accessories as required. and as per specification
266420KV, BPI
267145KV, BPI
26872.5KV, BPI
269F&I of Station Service Transformer (Energy efficiency level-3) and accessories as per specification.
270630 KVA, 33/0.4kV StationTransformer, including Terminal Clamps & Connectors.
271440V MCCB with Power receiving Panel as per scheme requirement (with structure, if applicable) for 630KVA Station Service Transformer
272F&I of Surge Arrester complete with Surge Counter, leakage current meter, clamps & connectors and other accessories as required and as per specification
273398kV, 20kA, LA
274120kV, 10kA, LA
27560kV, 10kA, LA
276F&I of Surge Arrester support structures, foundation bolts, nuts bolts etc as required and as per specification.
277398kV, 20kA, LA
278120kV, 10kA, LA
27960kV, 10kA, LA
280F&I of CVT and Pedestal Mounted Wave Trap complete with support insulators, hardware fittings, clamps & connectors, Junction Box and other accessories as required and as per specification.
281400kV, 8800pF, 3 Wdg CVT.
282132kV, 4400pF, 3 Wdg CVT.
283400KV, 3150A Wave Trap
284132KV, 800A Wave Trap.
285F&I of CVT pipe/Lattice support structure, foundation bolts, nuts bolts etc as required and as per specification.
286400kV, 8800pF, 3 Wdg CVT.
287132kV, 4400pF, 3 Wdg CVT.
288F&I of outdoor AIS Circuit Breaker along with clamps & connectors, support structures, foundation bolts and all other accessories as required and as per specification.
289145kV, 3150A, 40kA for 3 sec.
29072.5kV, 1250A, 40kA for 3 sec.
291F&I of Bay Marshalling Kiosk alongwith support structures, foundation bolts and all other accessories as required and as per specification
292400kV BMK
293132kV BMK
294F&I of CT & PT alongwith junction box, clamps & connectors and other accessories as required and as per specification
295132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
296132kV, 1600-800/1-1-1-1-1 (0.2S-PX-PX-PX-PX); 1 ph CT for 315MVA trafo bay
297132kV, 3000-1600/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for Bus coupler bay
29872.5kV, 50-25/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for transformer tertiary bay
299132kV, Potential Transformer (3 wdg, 0.2-3P-3P)
30072.5kV, Potential Transformer (3 wdg, 0.2-3P-3P)
301F&I of CT/PT support structures, foundation bolts, nuts bolts etc as required and as per specification.
302132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
303132kV, 1600-800/1-1-1-1-1 (0.2S-PX-PX-PX-PX); 1 ph CT for 315MVA trafo bay
304132kV, 3000-1600/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for Bus coupler bay
30572.5kV, 50-25/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for transformer tertiary bay
306132kV, Potential Transformer (3 wdg, 0.2-3P-3P)
30772.5kV, Potential Transformer (3 wdg, 0.2-3P-3P)
308F&I of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 400kV GIS
309400kV Bus Bar Protection Panel
310400kV Line CRP
311400/132kV ICT CRP (315MVA)
312400kV Bus Reactor CRP
313400kV Tie Breaker CRP
314F&I of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 132kV AIS
315132kV Line CRP (with line differential)
316400/132kV Transformer CRP (315MVA)
317132kV Bus Coupler CRP
318132kV Bus Bar CRP
319F&I of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 72.5kV AIS
320Station Service Transformer control & Protection Panel
321Relevant software for relay configuration & setting, maintenance etc.
322F&I of Phasor Measurement Unit as required and as per specification.
323Phasor Measurement Unit
324F&I of Complete Substation System Automation System (As per specification)
325Station HMI (Main, Redundant and Metering) with Industrial PC
326Maintenance HMI (DR Workstation) with Industrial PC
327Gate way with PLCC and Fibre Optic Modem and Panel
328SAS Inverter (5kVA)
329Colour Laser MFM Printer
330GPS Clock System
33116 port Ethernet Switch
332All interphase equipment for Gateway to SLDC
333VDU 75 inch
334Aux BCU with panel as per scheme requirement
335All other accessories like FO armoured cables, HDPE Conduit/GI conduit Patch cords,furnitures for HMIs and printers, cables etc as per requirement
336Station Ethernet Switch
337SAMAST compliant ABT meters including DCU, modems, FO cables and other related accessories etc.as per specification.
338Red Box
339Integration of the PMU and the Meters with the PDC, CDCS
340F&I of 400 kV GIS Equipment as per specification.
3413- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Line bay Module as per technical specification
3423- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Transformer bay Module with CSD as per technical specifcation
3433- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Tie bay Module without CSD as per technical specification.
3443- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Tie bay Module with CSD as per technical specification.
3453- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Bus Reactor bay Module with CSD as per technical specification
3463- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Bus bar Module each enclosed in bus bar enclosures running along the length of the switchgear to interconnect each of the circuit breaker bay modules in One and Half breaker configuration as per technical specification alongwith Extension module with all necessary arrangements for future extension of the GIS in One & Half Breaker Arrangement.
347400kV, 63kA for 3 sec, SF6 to Air Bushing along with termination module & support structure for outdoor connections to connect GIS with 400kV side of Power transformer, bus reactors and overhead lines.
348400kV, 63kA for 3 sec, SF6 Gas Insulated Bus Duct (GIB) single phase from respective GIS bay module up to SF6 to Air bushings including required support structures, jointing elements and other accessories for Transformer bays, line bays and bus reactor bays as per site requirement. (for both indoor and outdoor of GIS)
34910 Ton EOT Crane for 400kV GIS Building
350Scissor Lift
351F&I of Testing And Maintenance Equipment of GIS as specified.
352SF6 Gas Processing, Drying, Storage & Filling Unit
353SF6 gas quality testing unit
354SF6 Gas Leak Detector
355SF6 gas Mask
356F&I of 315MVA, 400/132/33kV, ONAN/ ONAF/ODAF or ONAN/ONAF1/ONAF2, ICT along with all accessories and below: (including terminal connectors and other acessories as per technical specification)
357315 MVA, 400/132/33 kV, Three phase Transformer with OLTC & Oil
358Oil & winding temperature monitoring system (FO based)
359Online DGA (Multi gas)
360Online insulating drying system
361Maintenance free breather
362RTCC Panel with AVR (TMS)
36310% Extra OIL for each transformer
364Rail track for transformer
365Pulling block for transformer
366F&I of 80 MVAR Bus Reactor (with Oil) as per specification.
36780 MVAR, 420KV, 3 Phase, Star with Neutral brought out, ONAN coreless Bus Reactor along with Marshalling Kiosk with accessories etc as per technical specification with 10% spare oil
368Pulling block for reactor
369F&I of Battery & Battery Chargers, DCDB & ACDB as per specification
370220V VRLA Battery 1600AH
371220V, Dual Float Cum Boost Chargers for 220V Battery 350A
372220V, DCDB
37348V VRLA type Battery Bank 600AH
37448V, Dual Float cum Boost Chargers for 48V Battery 130A
37548V, DCDB
376Main ACDB
377Sub ACDB
378MLDB with 415V/415V, 100kVA isolation transformer
379ELDB with 415V/415V, 50kVA isolation transformer
380HVAC DB
381MCBDB
382Aux ACDBs, Sub DCDBs etc, as per requirement
383F&I of Power Line Carrier Communication Equipments as per specification
384HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
385Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 200 km) for 400kV
386Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 100 km ) for 132kV
387IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 200 km(400kV)
388IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 50 km(132kV)
389LMU and LMDU
390EPAX system and telephone system with redundant power supply card and CPU along with E1 interface card.
391CAT 6 armoured cable.
3922 wire telephone set
393Audio Cable
394F&I of OPGW equipments as per specification as per specificationTransmission Equipment & SDH Equipment -STM16(ADM- up to five Direction)
395Base Equipment (Common Cards,Cross Connect/Control Cards,Optical base cards,Power supply cards,power cabling,other hardware & accessories including sub-racks,patch cords,DDF etc fully equippped with redundant Control Cards, Optical Base cards, Power Supply Cards (excluding Sl. No. 28 & 29 below.)
396F&I of OPGW equipments as per specification as per specificationOptical Interface/SFP for:
397SFP to support STM-4 upto 150km.
398SFP to support STM-16 upto 150km.
399F&I of OPGW equipments as per specification as per specificationTributary Cards
400E1 interface card (Minimum 63 interfaces per card)
401Ethernet interfaces with minimum of 10/100/1000Mbps configurable with Layer-2 switching (Minimum 8 interfaces per card)
4028 Port VOIP for remote locations
403Analog Telephone( 2-wire telephone for VOIP Gateway location)
404IEEE C37.94 (4 interfaces) to E1 converter/interface for intergration with SDH equipment
405F&I of OPGW equipments as per specification as per specificationEquipment Cabinets with power distribution Circuit breakers, Fan Cable Tray Cable glands entry from Top and bottom
406For SDH equipment(including DDF patching facilities and other accessories
407Main Distribution Frame(100 pairs)
408F&I of OPGW equipments as per specification as per specificationCraft Terminal
409Hardware (LAPTOP)
410Software
411Pre connectorized optical patch cords(Minium 8 patch cords per station)
412Firewall with deep inspection for IEC 104, IEC 61850 ,IEC 62443 certified with 5 years warranty
413Time synchronisation clock (MTCTE certified with multiband receiver) with all other accessories, cables etc.
414F&I of XLPE Armoured, LT Power Cable (1.1kV grade) as per specification
4152C, 6sqmm Cu
4164C, 16sqmm Cu
4173.5C, 35sqmm Al
4181C, 150sqmm Cu
4193.5C, 70sqmm Al
4203.5C, 150sqmm Al
4213.5C, 400sqmm Al
422Cable supports and other cable accessories
423Others ( Cable for Fire Fighting, Illumination etc)
424F&I of PVC Armoured Cu LT Control Cable (1.1 kV grade) as per specification
4254C, 2.5sqmm
4265C, 2.5sqmm
4277C, 2.5sqmm
42812C, 2.5sqmm
42917C, 2.5sqmm
43019C, 2.5sqmm
431Cable supports and other cable accessories
432F&I of Main earth mat conductor, GI risers, treated /Untreated earth pit, equipment earth connections etc.
43340 mm Dia MS Rod for Main/Auxiliary Earthmat
434Earthing Conductor: 40 Mm Dia MS Rod For Riser From The Burial Earth Mat To Equipment,Structure, Fence Etc)
435Earthing Conductor: 75X 12 Mm GS (HDG) Flat For equipment and structure earthing
436Earthing Conductor: 50X10Mm GS(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
437Earthing Device & Associated Accessories (50 Mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI Cover.
438Earthing Device & Associated Accessories 40Mm dia MS Rod 3 Mtrs Long For Non Treated Earth Pit with CI Cover.
439Soil Resistivity Test And Soil Treatment As And When Required
440Separate Earthing For 400 kV GIS modules with multipoint earthing (with Cu flat of adequate size for GIS earth mat)
441Separate Earthing For 400 kV GIS Building with earth electrodes & Copper earthing conductors etc. complete with all respects
442Separate Earthing for all other switchyard buildings, fencing etc. with earth electrodes, GS earthing conductors etc. complete with all respects
443F&I of Mild Steel (Galvanised) Lattice structures for incoming and outgoing gantries etc as required complete with foundation bolts, fastners etc.
444400kV Columns with peak
445400kV Beams
446132kV Columns with/without peak
447132kV Beams
448F&I of Fire Alarm & Detection including all accessories as per specification
449Fire Alarm & Detection system for 400kV GIS Buildings, Control Room , Panel Room, DB room, Battery Room including Fire Alarm panel, Multi Sensor detector, Smoke detector, manual Call point, Hooter, Response Indicators, Beam Detector, Cabling, ISOLATING MODULE etc.
450Portable and wheel/trolley mounted Fire Extinguishers for Control Room Building and Switchyard as per specification and Portable Fire Extinguisher for 400kV GIS Hall each (5kg X 6 Nos),Control room (2kg X 6 Nos), Security Barrack (2kg X 6Nos),Guard room (Security Booth) (2kg X 3Nos), Switchyard (5kg X 4Nos) ( as per specification.
451Dry powder chemical type 10 kg. For 630 kVA transformer
452Fire fire fighting system (sprinkler system) for control room as per requirement
453F&I of HVAC & VENTILATION
4542 TON CAPACITY SPLIT AIR CONDITIONING UNITS for CRP/PLCC/DB Room with N+1 requirements
455Ventilation system for 400kV GIS Building (Ventilation System with Centrifugal Fan and related Accessories should comprise of Pre and Fine air filter,Air Purifier, centrifugal fan, ducting network, air supply grilles, gravity dampers, electrical and instrumentation etc.)
456F&I of Hydrant & HVWS (High Velocity Water Spray) system/NIFPES including all accessories as per specification.
457Hydrant system along with pumping arrangement & associated Civil works for fire protection system
458HVWS system (automatic emulsifier and manual hydrant point both) for 315 MVA ICT-2 No’s and 80MVAr Bus Reactor -2 nos.
459NItrogen injection Fire protection and emergency service with complete accessories and related Civil and Electrical works for 315MVA ICT-2 No’s, 80MVAR Bus reactor-2 nos.
460250 KVA, silent type DG Set with AMF including Panel & all accessories and including earthing arrangement alongwith outdoor distibution board as per scheme requirement.
461Lighting System F&I of Outdoor Lighting
462Outdoor LED lighting for Approach road, Switchyard area, Colony area, Road area, Car parking, Security outpost, open store shed, Bore and OHT area, etc, including Lighting panel, Cabling, street lighting, Switches, Distribution boards, Socket, auxiliary receptacle, complete with GI Poles etc.
463F&I of Public Addressing System & CCTV complete with all accessories as per specification.
464Public Addressing System & CCTV complete with all accessories as per specification.
465F&I of Lightining System
466Lightning protection system LCLM (lightning masts 50 metres high, Lightning Spike, shield wire(7/4mm GI Shield wire), down conductors etc.) for complete substation.
467Erection of Isolator mounting structure including contsruction of foundation and supply of all foundation materials and labour etc.
468145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
469145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
470145KV, 3150A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
471145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Tandem Isolator
47272.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch.
47372.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch.
474Erection Testing and Commissioning of Isolators with all accessories, laying and termination of LT power & control cables, fitting fixing of clamps and jumpers etc. as required.
475145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
476145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
477145KV, 3150A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
478145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Tandem Isolator
47972.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator without earth switch.
48072.5kV,1250A, 31.5kA for 3sec Horizontal Double Break type Isolator with earth switch.
481Hoisting and erection of hardware fittings complete set with nuts bolts, clamps and other accessories as required and stringing of Bus/conductor/jumpers as required.
482400kV, 4X160kN Quad tension string suitable for Quad Moose conductor.
483400kV, 2X160kN Double tension string suitable for Single Moose conductor.
484400kV, 2X120kN Double suspension string suitable for Quad Moose conductor.
485132kV, 2x90kN double tension string suitable for Single AAAC Panther conductor.
486132kV, 2x120kN double suspension string suitable for Twin MOOSE conductor.
487132kV, 2x160kN double tension string suitable for Twin MOOSE conductor.
488132kV, 2X120kN Double suspension string suitable for Quad Moose conductor.
489132kV, 4X160kN Quad tension string suitable for Quad Moose conductor.
490Erection Testing and Commissioning of Conductors, Clamp Connectors as required and as per spefication
4914'' IPS Aluminium Tubular Conductors (Schedule 40) with flexi connectors, expansion joints, T- joints, end caps etc as required.
492ACSR Moose Conductor as per site requirement
493Clamps & Connectors as per requirement
494Erection of BPI mounting structures including contsruction of foundation and supply of all foundation materials and labour etc.
495420KV, BPI
496145KV, BPI
49772.5KV, BPI
498Erection, Testing & Commissioning of 1 phase Solid core bus post insulator including clamp connectors and other accessories as required.
499420KV, BPI
500145KV, BPI
50172.5KV, BPI
502Erection Testing and Commissioning of Station Service Transformer, PRP (with structure, if applicable) and its accessories as below including laying and termination of LT power and control cables
503630 KVA, 33/0.4kV StationTransformer, including Terminal Clamps & Connectors.
504440V MCCB with Power receiving Panel as per scheme requirement (with structure, if applicable) for 630KVA Station Service Transformer
505Erection of LA mounting structure including contsruction of foundation and supply of all foundation materials and labour etc.
506398kV, 20kA, LA
507120kV, 10kA, LA
50860kV, 10kA, LA
509Erection, Testing & Commissioning of Surge Arrester alongwith erection of mounting structure, Including fitting and fixing of all accessories, clamps and connectors etc complete.
510398kV, 20kA, LA
511120kV, 10kA, LA
51260kV, 10kA, LA
513Erection Testing & Commissioning of CVT and Wave Trap alongwith erection (for CVT), of Junction box, laying and termination of cables. Including fitting and fixing of all accessories, clamps and connectors etc.
514400kV, 8800pF, 3 Wdg CVT.
515132kV, 4400pF, 3 Wdg CVT.
516400KV, 3150A Wave Trap
517132KV, 800A Wave Trap.
518Erection of CVT mounting structure including contsruction of foundation and supply of all foundation materials and labour etc.
519400kV, 8800pF, 3 Wdg CVT.
520132kV, 4400pF, 3 Wdg CVT.
521Erection Testing & Commissioning of Circuit Breaker (Outdoor AIS) alongwith erection of mounting structures, laying and termination of LT power and control cables including fitting and fixing of all accessories, clamps and connectors and including contsruction of foundation and supply of all foundation materials and labour complete.
522145kV, 3150A, 40kA for 3 sec.
52372.5kV, 1250A, 40kA for 3 sec.
524Erection Testing & Commissioning of Bay Marshalling Kiosk alongwith structure including laying and termination of LT power and control cables, construction of foundation alongwith supply of all foundation materials and labour as required.
525400kV BMK
526132kV BMK
527Erection of Instrument Transformer (CT & PT) mounting structure including contsruction of foundation and supply of all foundation materials and labour etc.
528132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
529132kV, 1600-800/1-1-1-1-1 (0.2S-PX-PX-PX-PX); 1 ph CT for 315MVA trafo bay
530132kV, 3000-1600/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for Bus coupler bay
53172.5kV, 50-25/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for transformer tertiary bay
532132kV, Potential Transformer (3 wdg, 0.2-3P-3P)
53372.5kV, Potential Transformer (3 wdg, 0.2-3P-3P)
534Erection Testing & Commissioning of Instrument Transformer (CT & PT) alongwith erection of Junction box, laying and termination of cables. Including fitting and fixing of all accessories, clamps and connectors etc complete.
535132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
536132kV, 1600-800/1-1-1-1-1 (0.2S-PX-PX-PX-PX); 1 ph CT for 315MVA trafo bay
537132kV, 3000-1600/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for Bus coupler bay
53872.5kV, 50-25/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 ph CT for transformer tertiary bay
539132kV, Potential Transformer (3 wdg, 0.2-3P-3P)
54072.5kV, Potential Transformer (3 wdg, 0.2-3P-3P)
541Erection Testing & Commissioning and installation of Control, Relay & Protection Panels (Simplex Type) including laying and termination of LT power and control cables for 400kV GIS
542400kV Bus Bar Protection Panel
543400kV Line CRP
544400/132kV ICT CRP (315MVA)
545400kV Bus Reactor CRP
546400kV Tie Breaker CRP
547Erection Testing & Commissioning and installation of Control, Relay & Protection Panels (Simplex Type) including laying and termination of LT power and control cables for 132kV AIS
548132kV Line CRP (with line differential)
549400/132kV Transformer CRP (315MVA)
550132kV Bus Coupler CRP
551132kV Bus Bar CRP
552Erection Testing & Commissioning and installation of Control, Relay & Protection Panels (Simplex Type) including laying and termination of LT power and control cables for 72.5kV AIS
553Station Service Transformer control & Protection Panel
554Relevant software for relay configuration & setting, maintenance etc.
555Erection Testing & Commissioning and installation of Phasor Measurement Unit as required and as per specification.
556Phasor Measurement Unit
557Erection Testing & Commissioning and installation of Complete Substation System Automation System (As per specification) including laying and termination of LT power and control cables
558Station HMI (Main, Redundant and Metering) with Industrial PC
559Maintenance HMI (DR Workstation) with Industrial PC
560Gate way with PLCC and Fibre Optic Modem and Panel
561SAS Inverter (5kVA)
562Colour Laser MFM Printer
563GPS Clock System
56416 port Ethernet Switch
565All interphase equipment for Gateway to SLDC
566VDU 75 inch
567Aux BCU with panel as per scheme requirement
568All other accessories like FO armoured cables, HDPE Conduit/GI conduit Patch cords,furnitures for HMIs and printers, cables etc as per requirement
569Station Ethernet Switch
570SAMAST compliant ABT meters including DCU, modems, FO cables and other related accessories etc.as per specification.
571Red Box
572Integration of the PMU and the Meters with the PDC, CDCS
573Erection Testing & Commissioning and installation of 400 kV GIS Modules and Equipment including laying and termination of LT power and control cables, installation of all accessories as required including construction of foundation and supply of all foundation materials and labour.
5743- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Line bay Module as per technical specification
5753- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Transformer bay Module with CSD as per technical specifcation
5763- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Tie bay Module without CSD as per technical specification.
5773- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Tie bay Module with CSD as per technical specification.
5783- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Bus Reactor bay Module with CSD as per technical specification
5793- Ø 400 kV, 4000 A, 63 kA-3 sec, metal enclosed SF6 Gas Insulated Switchgear - Bus bar Module each enclosed in bus bar enclosures running along the length of the switchgear to interconnect each of the circuit breaker bay modules in One and Half breaker configuration as per technical specification alongwith Extension module with all necessary arrangements for future extension of the GIS in One & Half Breaker Arrangement.
580400kV, 63kA for 3 sec, SF6 to Air Bushing along with termination module & support structure for outdoor connections to connect GIS with 400kV side of Power transformer, bus reactors and overhead lines.
581400kV, 63kA for 3 sec, SF6 Gas Insulated Bus Duct (GIB) single phase from respective GIS bay module up to SF6 to Air bushings including required support structures, jointing elements and other accessories for Transformer bays, line bays and bus reactor bays as per site requirement. (for both indoor and outdoor of GIS)
58210 Ton EOT Crane for 400kV GIS Building
583Scissor Lift
584Installation and demo of Testing And Maintenance Equipment of GIS
585SF6 Gas Processing, Drying, Storage & Filling Unit
586SF6 gas quality testing unit
587SF6 Gas Leak Detector
588SF6 gas Mask
589Erection, testing and commissioning of 315MVA, 400/132/33kV, ONAN/ ONAF/ODAF or ONAN/ONAF1/ONAF2 ICT and all accessories, terminal connectors as per technical specification including laying and termination of LT power, control cables and other signalling cables as required.
590315 MVA, 400/132/33 kV, Three phase Transformer with OLTC & Oil
591Oil & winding temperature monitoring system (FO based)
592Online DGA (Multi gas)
593Online insulating drying system
594Maintenance free breather
595RTCC Panel with AVR (TMS)
596Rail track for transformer
597Pulling block for transformer
598Erection, Testing & Commissioning of 80 MVAR Bus Reactor including laying and termination of LT power and control cables and other signalling cables as required.
59980 MVAR, 420KV, 3 Phase, Star with Neutral brought out, ONAN coreless Bus Reactor along with Marshalling Kiosk with accessories etc as per technical specification with 10% spare oil
600Pulling block for reactor
601Erection, Testing & Commissioning of Battery & Battery Chargers, DCDB & ACDB as per specification including laying and termination of LT power and control cables as required.
602220V VRLA Battery 1600AH
603220V, Dual Float Cum Boost Chargers for 220V Battery 350A
604220V, DCDB
60548V VRLA type Battery Bank 600AH
60648V, Dual Float cum Boost Chargers for 48V Battery 130A
60748V, DCDB
608Main ACDB
609Sub ACDB
610MLDB with 415V/415V, 100kVA isolation transformer
611ELDB with 415V/415V, 50kVA isolation transformer
612HVAC DB
613MCBDB
614Aux ACDBs, Sub DCDBs etc, as per requirement
615Erection, Testing & Commissioning of Power Line Carrier Communication Equipments including laying and termination of LT power and control cables
616HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
617Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 200 km) for 400kV
618Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 100 km ) for 132kV
619IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 200 km(400kV)
620IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 50 km(132kV)
621LMU and LMDU
622EPAX system and telephone system with redundant power supply card and CPU along with E1 interface card.
623CAT 6 armoured cable.
6242 wire telephone set
625Audio Cable
626Erection, Testing and Commissioning of OPGW equipments as per specification including laying and termination of LT power and control cables and other accessories as required.Transmission Equipment & SDH Equipment -STM16(ADM- up to five Direction)
627Base Equipment (Common Cards,Cross Connect/Control Cards,Optical base cards,Power supply cards,power cabling,other hardware & accessories including sub-racks,patch cords,DDF etc fully equippped with redundant Control Cards, Optical Base cards, Power Supply Cards (excluding Sl. No. 28 & 29 below.)
628Erection, Testing and Commissioning of OPGW equipments as per specification including laying and termination of LT power and control cables and other accessories as required.Optical Interface/SFP for:
629SFP to support STM-4 upto 150km.
630SFP to support STM-16 upto 150km.
631Erection, Testing and Commissioning of OPGW equipments as per specification including laying and termination of LT power and control cables and other accessories as required.Tributary Cards
632E1 interface card (Minimum 63 interfaces per card)
633Ethernet interfaces with minimum of 10/100/1000Mbps configurable with Layer-2 switching (Minimum 8 interfaces per card)
6348 Port VOIP for remote locations
635Analog Telephone( 2-wire telephone for VOIP Gateway location)
636IEEE C37.94 (4 interfaces) to E1 converter/interface for intergration with SDH equipment
637Erection, Testing and Commissioning of OPGW equipments as per specification including laying and termination of LT power and control cables and other accessories as required.Equipment Cabinets with power distribution Circuit breakers, Fan Cable Tray Cable glands entry from Top and bottom
638For SDH equipment(including DDF patching facilities and other accessories
639Main Distribution Frame(100 pairs)
640Erection, Testing and Commissioning of OPGW equipments as per specification including laying and termination of LT power and control cables and other accessories as required.Craft Terminal
641Hardware (LAPTOP)
642Software
643Pre connectorized optical patch cords(Minium 8 patch cords per station)
644Firewall with deep inspection for IEC 104, IEC 61850 ,IEC 62443 certified with 5 years warranty
645Time synchronisation clock (MTCTE certified with multiband receiver) with all other accessories, cables etc.
646Concreting of Gantry foundation including all Labour, materials, equipment, excavation shuttering, head loading, back filling etc complete for handling, transportation, batching, mixing, placing, levelling, curing etc complete inclusive of cost of cement and reinforcement steel. Also provide 300 mm boulder soiling below the foundation
647400kV Columns with peak
648Concreting of Gantry foundation including all Labour, materials, equipment, excavation shuttering, head loading, back filling etc complete for handling, transportation, batching, mixing, placing, levelling, curing etc complete inclusive of cost of cement and reinforcement steel. Also provide 300 mm boulder soiling below the foundation
649132kV Columns with/without peak
650Installation & Testing of complete Earthing system as per technical specification.
65140 mm Dia MS Rod for Main/Auxiliary Earthmat
652Earthing Conductor: 40 Mm Dia MS Rod For Riser From The Burial Earth Mat To Equipment,Structure, Fence Etc)
653Earthing Conductor: 75X 12 Mm GS (HDG) Flat For equipment and structure earthing
654Earthing Conductor: 50X10Mm GS(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
655Earthing Device & Associated Accessories (50 Mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI Cover.
656Earthing Device & Associated Accessories 40Mm dia MS Rod 3 Mtrs Long For Non Treated Earth Pit with CI Cover.
657Soil Resistivity Test And Soil Treatment As And When Required
658Separate Earthing For 400 kV GIS modules with multipoint earthing (with Cu flat of adequate size for GIS earth mat)
659Separate Earthing For 400 kV GIS Building with earth electrodes & Copper earthing conductors etc. complete with all respects
660Separate Earthing for all other switchyard buildings, fencing etc. with earth electrodes, GS earthing conductors etc. complete with all respects
661Erection of Lattice structures for incoming and outgoing gantries etc.
662400kV Columns with peak
663400kV Beams
664132kV Columns with/without peak
665132kV Beams
666Installation and Testing & Commissioning of Fire Alarm & Detection including laying and termination of LT power and control cables
667Fire Alarm & Detection system for 400kV GIS Buildings, Control Room , Panel Room, DB room, Battery Room including Fire Alarm panel, Multi Sensor detector, Smoke detector, manual Call point, Hooter, Response Indicators, Beam Detector, Cabling, ISOLATING MODULE etc.
668Fire fire fighting system (sprinkler system) for control room as per requirement
669Erection, testing, commissioning HVAC & VENTILATION
6702 TON CAPACITY SPLIT AIR CONDITIONING UNITS for CRP/PLCC/DB Room with N+1 requirements
671Ventilation system for 400kV GIS Building (Ventilation System with Centrifugal Fan and related Accessories should comprise of Pre and Fine air filter,Air Purifier, centrifugal fan, ducting network, air supply grilles, gravity dampers, electrical and instrumentation etc.)
672Erection and Testing & Commissioning of Hydrant & HVWS (High Velocity Water Spray) system/NIFPES including laying and termination of LT power and control cables
673Hydrant system along with pumping arrangement & associated Civil works for fire protection system
674HVWS system (automatic emulsifier and manual hydrant point both) for 315 MVA ICT-2 No’s and 80MVAr Bus Reactor -2 nos.
675NItrogen injection Fire protection and emergency service with complete accessories and related Civil and Electrical works for 315MVA ICT-2 No’s, 80MVAR Bus reactor-2 nos.
676250 KVA, silent type DG Set with AMF including Panel & all accessories and including earthing arrangement alongwith outdoor distibution board as per scheme requirement.
677Erection and Testing & Commissioning of Lighting System including laying and termination of illumination cables, GI shield wires etc.
678Outdoor LED lighting for Approach road, Switchyard area, Colony area, Road area, Car parking, Security outpost, open store shed, Bore and OHT area, etc, including Lighting panel, Cabling, street lighting, Switches, Distribution boards, Socket, auxiliary receptacle, complete with GI Poles etc.
679Erection and Testing & Commissioning of Public Addressing System & CCTV complete with all accessories as per specification.
680Public Addressing System & CCTV complete with all accessories as per specification.
681Erection and Testing & Commissioning of Lightining including laying and termination of illumination cables, GI shield wires etc.
682Lightning protection system LCLM (lightning masts 50 metres high, Lightning Spike, shield wire(7/4mm GI Shield wire), down conductors etc.) for complete substation.
683Site Preparation Works
684Soil Investigation
685Site Clearance including necessary excavation and dismantling of existing structure
686Standards, Design and Drawing
687Site Preparation and Earthfilling with Compaction
688Earthcutting and necessary levelling
689RCC Retaining wall with counterfort wall
690Boulder Pitching with 100 mm PCC on top
691Brick Boundary wall
692Security Fencing
693Buildings (including All services i.e. electrical, internal water supply, sanitary works, sewage system, furnishing, cable trench (present and future) complete)
694400 KV GIS cum Control Room/CRP/DB Building (PEB) alongwith GIS bay foundations complete [90m x (16+8)m]
695Constrcution of Transformer and Reactor foundation
696Counstruction of 315 MVA Power Transformer foundation with Burnt Oil Pit
697Counstruction of 80MVAR Bus Reactor foundation with Burnt Oil Pit
698Fire Protection Wall in RCC frame with 230 mm brick wall including supply of all foundation materials and labour on pile foundation
699Fire Protection Wall for 315 MVA Transformer
700Fire Protection Wall for 80 MVAr Reactor
701HVWS with Water reserviour and Pumphouse
702Supply and installation of Deep tubewell, with appropriate depth required to reach aquifer with PVC casing pipe (200 mm diameter minimum), 3 HP submersible mortor pump, 40 mm diameter CPVC column pipe and Construction of Water reservior and Pump house for fire fighting.
703Water Supply work
704Construction of RCC (M-25 grade) reservoir 600 mm above FGL (Capacity 15000 Ltr) alongwith supply and Installation of distribution network with CPVC pipe of 40 mm diameter and 25 mm diameter for connecting to Overhead tank of all buildings.
705Cable Trench along with road crossing culvert for cables wherever necesarry along with switchyard work
706A type
707B Type
708C Type
709D Type
710HDPE pipe of 150 mm dia
711RCC Box Culvert
712Approach Road (RCC)
713Internal Road (RCC)
714Antiweed treatment
715PCC in Switchyard
716Stone Spreading(Gravelling) in switchyard
717Storm Water Drain
718Sump Pit with electric pump set
719Main Gate
720Switchyard Gate
721Rain water Harvesting with construction of RCC reservoir
722Rain water Harvesting with construction of RCC reservoir
723Supply of Isolators, with both manual and motor driven operating mechanisms along with Support Insulators, clamps & connectors as required and as per spefication
724145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
725145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
726Supply of Isolator mounting structures, foundation bolts, nuts bolts etc. as required. and as per spefication
727145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
728145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
729Supply of insulator string assembly with antifog insulators and hardware fittings complete set with nuts bolts, clamps and other accessories as required and as per spefication
730132kV, 2x70kN double suspension string suitable for Twin Panther conductors
731132kV, 2x90kN double tension string suitable for Twin Panther conductors
732132kV, 90kN tension string suitable for Single Panther conductor.
733132kV, 70kN suspension string suitable for Single Panther conductor.
734Supply of Conductors, Clamp Connectors as required and as per spefication
735ACSR Panther Conductor as per site requirement
736Clamps & Connectors as per requirement
737Supply of 1 phase Solid core bus post insulator with creepage distance 31mm/kV including clamp connectors and other accessories as required and as per specification
738145KV, BPI
739Supply of bus post insulator support structures, foundation bolts, nuts & bolts and other accessories as required. and as per specification
740145KV, BPI
741Supply of Surge Arrester complete with Surge Counter, leakage current meter, clamps & connectors and other accessories as required and as per specification
742120kV, 10kA, LA
743Supply of Surge Arrester support structures, foundation bolts, nuts bolts etc as required and as per specification.
744120kV, 10kA, LA
745Supply of CVT and Pedestal Mounted Wave Trap complete with support insulators, hardware fittings, clamps & connectors, Junction Box and other accessories as required and as per specification.
746132kV, 4400pF, 3 Wdg CVT.
747132KV, 800A Wave Trap.
748Supply of CVT pipe/Lattice support structure, foundation bolts, nuts bolts etc as required and as per specification.
749132kV, 4400pF, 3 Wdg CVT.
750Supply of outdoor AIS Circuit Breaker along with clamps & connectors, support structures, foundation bolts and all other accessories as required and as per specification.
751145kV, 3150A, 40kA for 3 sec.
752Supply of Bay Marshalling Kiosk alongwith support structures, foundation bolts and all other accessories as required and as per specification
753132kV BMK
754Supply of CT & PT alongwith junction box, clamps & connectors and other accessories as required and as per specification
755132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
756Supply of CT/PT support structures, foundation bolts, nuts bolts etc as required and as per specification.
757132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
758Supply of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 132kV AIS
759132kV Line CRP (with line differential)
760Supply of Substation System Automation System (As per specification)
76116 port Ethernet Switch
762SAMAST compliant ABT meters
763Integration of two new CRP's with the existing SAS
764Supply of Power Line Carrier Communication Equipments as per specification
765HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
766Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 100 km ) for 132kV
767IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 100 km(132kV)
768LMU and LMDU
769CAT 6 armoured cable.
7702 wire telephone set
771Audio Cable
772Supply of XLPE Armoured, LT Power Cable (1.1kV grade) as per specification
7732C, 6sqmm Cu
7744C, 16sqmm Cu
775Cable supports and other cable accessories
776Supply of PVC Armoured Cu LT Control Cable (1.1 kV grade) as per specification
7775C, 2.5sqmm
77812C, 2.5sqmm
77919C, 2.5sqmm
780Cable supports and other cable accessories
781Supply of Main earth mat conductor, GI risers, treated /Untreated earth pit, equipment earth connections etc.
78275 x 12 mm GS(HDG) Flat for Main/Auxiliary Earthmat/Riser
783Earthing Conductor: 50X10Mm GS(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
784Earthing Device & Associated Accessories (50 Mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI Cover.
785Earthing Device & Associated Accessories 40Mm dia MS Rod 3 Mtrs Long For Non Treated Earth Pit with CI Cover.
786Soil Resistivity Test And Soil Treatment As And When Required
787Separate Earthing for all other switchyard buildings, fencing etc. with earth electrodes, GS earthing conductors etc. complete with all respects
788Supply of Mild Steel (Galvanised) Lattice structures for incoming and outgoing gantries etc as required complete with foundation bolts, fastners etc.
789132kV Columns with/without peak
790132kV Beams
791Lighting System Supply of Outdoor Lighting
792Outdoor LED lighting for new extended switchyard area
793Supply of Lightining System
794Lightning protection system LCLM (lightning masts 50 metres high, Lightning Spike, shield wire(7/4mm GI Shield wire), down conductors etc.) for complete substation.
795F&I of Isolators, with both manual and motor driven operating mechanisms along with Support Insulators, clamps & connectors as required and as per spefication
796145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
797145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
798F&I of Isolator mounting structures, foundation bolts, nuts bolts etc. as required. and as per spefication
799145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
800145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
801F&I of insulator string assembly with antifog insulators and hardware fittings complete set with nuts bolts, clamps and other accessories as required and as per spefication
802132kV, 2x70kN double suspension string suitable for Twin Panther conductors
803132kV, 2x90kN double tension string suitable for Twin Panther conductors
804132kV, 90kN tension string suitable for Single Panther conductor.
805132kV, 70kN suspension string suitable for Single Panther conductor.
806F&I of Conductors, Clamp Connectors as required and as per spefication
807ACSR Panther Conductor as per site requirement
808Clamps & Connectors as per requirement
809F&I of 1 phase Solid core bus post insulator with creepage distance 31mm/kV including clamp connectors and other accessories as required and as per specification
810145KV, BPI
811F&I of bus post insulator support structures, foundation bolts, nuts & bolts and other accessories as required. and as per specification
812145KV, BPI
813F&I of Surge Arrester complete with Surge Counter, leakage current meter, clamps & connectors and other accessories as required and as per specification
814120kV, 10kA, LA
815F&I of Surge Arrester support structures, foundation bolts, nuts bolts etc as required and as per specification.
816120kV, 10kA, LA
817F&I of CVT and Pedestal Mounted Wave Trap complete with support insulators, hardware fittings, clamps & connectors, Junction Box and other accessories as required and as per specification.
818132kV, 4400pF, 3 Wdg CVT.
819132KV, 800A Wave Trap.
820F&I of CVT pipe/Lattice support structure, foundation bolts, nuts bolts etc as required and as per specification.
821132kV, 4400pF, 3 Wdg CVT.
822F&I of outdoor AIS Circuit Breaker along with clamps & connectors, support structures, foundation bolts and all other accessories as required and as per specification.
823145kV, 3150A, 40kA for 3 sec.
824F&I of Bay Marshalling Kiosk alongwith support structures, foundation bolts and all other accessories as required and as per specification
825132kV BMK
826F&I of CT & PT alongwith junction box, clamps & connectors and other accessories as required and as per specification
827132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
828F&I of CT/PT support structures, foundation bolts, nuts bolts etc as required and as per specification.
829132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
830F&I of Control, Relay & Protection Panel(Simplex Type) as per specification along with all accessories as required for 132kV AIS
831132kV Line CRP (with line differential)
832F&I of Substation System Automation System (As per specification)
83316 port Ethernet Switch
834SAMAST compliant ABT meters
835Integration of two new CRP's with the existing SAS
836F&I of Power Line Carrier Communication Equipments as per specification
837HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
838Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 100 km ) for 132kV
839IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 100 km(132kV)
840LMU and LMDU
841CAT 6 armoured cable.
8422 wire telephone set
843Audio Cable
844F&I of XLPE Armoured, LT Power Cable (1.1kV grade) as per specification
8452C, 6sqmm Cu
8464C, 16sqmm Cu
847Cable supports and other cable accessories
848F&I of PVC Armoured Cu LT Control Cable (1.1 kV grade) as per specification
8495C, 2.5sqmm
85012C, 2.5sqmm
85119C, 2.5sqmm
852Cable supports and other cable accessories
853F&I of Main earth mat conductor, GI risers, treated /Untreated earth pit, equipment earth connections etc.
85475 x 12 mm GS(HDG) Flat for Main/Auxiliary Earthmat/Riser
855Earthing Conductor: 50X10Mm GS(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
856Earthing Device & Associated Accessories (50 Mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI Cover.
857Earthing Device & Associated Accessories 40Mm dia MS Rod 3 Mtrs Long For Non Treated Earth Pit with CI Cover.
858Soil Resistivity Test And Soil Treatment As And When Required
859Separate Earthing for all other switchyard buildings, fencing etc. with earth electrodes, GS earthing conductors etc. complete with all respects
860F&I of Mild Steel (Galvanised) Lattice structures for incoming and outgoing gantries etc as required complete with foundation bolts, fastners etc.
861132kV Columns with/without peak
862132kV Beams
863Lighting System F&I of Outdoor Lighting
864Outdoor LED lighting for new extended switchyard area
865F&I of Lightining System
866Lightning protection system LCLM (lightning masts 50 metres high, Lightning Spike, shield wire(7/4mm GI Shield wire), down conductors etc.) for complete substation.
867Erection of Isolator mounting structure including contsruction of foundation and supply of all foundation materials and labour etc.
868145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
869145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
870Erection Testing and Commissioning of Isolators with all accessories, laying and termination of LT power & control cables, fitting fixing of clamps and jumpers etc. as required.
871145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator with single earth switch
872145KV, 2000A, 40kA for 3 sec, Horizontal Double Breaktype Isolator without earth switch
873Hoisting and erection of hardware fittings complete set with nuts bolts, clamps and other accessories as required and stringing of Bus/conductor/jumpers as required.
874132kV, 2x70kN double suspension string suitable for Twin Panther conductors
875132kV, 2x90kN double tension string suitable for Twin Panther conductors
876132kV, 90kN tension string suitable for Single Panther conductor.
877132kV, 70kN suspension string suitable for Single Panther conductor.
878Erection, Testing & Commissioning of Conductors, Clamp Connectors as required and as per spefication
879ACSR Panther Conductor as per site requirement
880Clamps & Connectors as per requirement
881Erection of BPI mounting structures including contsruction of foundation and supply of all foundation materials and labour
882145KV, BPI
883Erection, Testing & Commissioning of 1 phase Solid core bus post insulator including clamp connectors and other accessories as required.
884145KV, BPI
885Erection of LA mounting structure including contsruction of foundation and supply of all foundation materials and labour
886120kV, 10kA, LA
887Erection, Testing & Commissioning of Surge Arrester alongwith erection of mounting structure, Including fitting and fixing of all accessories, clamps and connectors etc complete.
888120kV, 10kA, LA
889Erection Testing & Commissioning of CVT and Wave Trap alongwith erection (for CVT), of Junction box, laying and termination of cables. Including fitting and fixing of all accessories, clamps and connectors etc.
890132kV, 4400pF, 3 Wdg CVT.
891132KV, 800A Wave Trap.
892Erection of CVT mounting structure including contsruction of foundation and supply of all foundation materials and labour
893132kV, 4400pF, 3 Wdg CVT.
894Erection Testing & Commissioning of Circuit Breaker (Outdoor AIS) alongwith erection of mounting structures, laying and termination of LT power and control cables including fitting and fixing of all accessories, clamps and connectors and including contsruction of foundation and supply of all foundation materials and labour complete.
895145kV, 3150A, 40kA for 3 sec.
896Erection Testing & Commissioning of Bay Marshalling Kiosk alongwith structure including laying and termination of LT power and control cables, construction of foundation alongwith supply of all foundation materials and labour as required.
897132kV BMK
898Erection Testing & Commissioning of Instrument Transformer (CT & PT) alongwith erection of Junction box, laying and termination of cables. Including fitting and fixing of all accessories, clamps and connectors etc complete.
899132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
900Erection of Instrument Transformer (CT & PT) mounting structure including contsruction of foundation and supply of all foundation materials and labour
901132kV, 600-300/1-1-1-1-1 (0.2S-5P20-PX-PX-PX); 1 Ph, CT for line bay
902Erection Testing & Commissioning and installation of Control, Relay & Protection Panels (Simplex Type) including laying and termination of LT power and control cables
903132kV Line CRP (with line differential)
904Erection, Testing, Commissioning Substation System Automation System (As per specification )
90516 port Ethernet Switch
906SAMAST compliant ABT meters
907Integration of two new CRP's with the existing SAS
908Erection, Testing & Commissioning of Power Line Carrier Communication Equipments including laying and termination of LT power and control cables
909HF armoured co-axial cable (ALONGWITH HDPE /GI CONDUIT)
910Digital Carrier Equipment Panel (Twin channel and should support transmission band for line length 100 km ) for 132kV
911IEC 61850 compliant Digital Tele- Protection Coupler, 16 command with redundant power supply card and CPU along with analog PLCC interface card, E1 interface card and optical interface card to support 100 km(132kV)
912LMU and LMDU
913CAT 6 armoured cable.
9142 wire telephone set
915Audio Cable
916Concreting of Gantry foundation including all Labour, materials, equipment, excavation shuttering, head loading, back filling etc complete for handling, transportation, batching, mixing, placing, levelling, curing etc complete inclusive of cost of cement and reinforcement steel. Also provide 300 mm boulder soiling below the foundation
917132kV Columns with/without peak
918Installation & Testing of complete Earthing system as per technical specification.
91975 x 12 mm GS(HDG) Flat for Main/Auxiliary Earthmat/Riser
920Earthing Conductor: 50X10Mm GS(HDG) Flat For Riser For Console Box,Lt Panels,Dc Panels,Marshalling Boxes, Cable Trenches Etc)
921Earthing Device & Associated Accessories (50 Mm dia Heavy Duty GI Perforated Pipe 3 Mtrs Long For Treated Earth Pit with CI Cover.
922Earthing Device & Associated Accessories 40Mm dia MS Rod 3 Mtrs Long For Non Treated Earth Pit with CI Cover.
923Soil Resistivity Test And Soil Treatment As And When Required
924Separate Earthing for all other switchyard buildings, fencing etc. with earth electrodes, GS earthing conductors etc. complete with all respects
925Erection of Lattice structures for incoming and outgoing gantries etc.
926132kV Columns with/without peak
927132kV Beams
928Erection and Testing & Commissioning of Lighting System including laying and termination of illumination cables, GI shield wires etc.
929Outdoor LED lighting for new extended switchyard area
930Erection and Testing & Commissioning of Lightining including laying and termination of illumination cables, GI shield wires etc.
931Lightning protection system LCLM (lightning masts 50 metres high, Lightning Spike, shield wire(7/4mm GI Shield wire), down conductors etc.) for complete substation.
932Site Preparation Works
933Site Clearance including necessary excavation and dismantling of existing structure
934Standards, Design and Drawing
935Site Preparation and Earthfilling with Compaction
936Earthcutting and necessary levelling
937RCC Retaining wall with counterfort wall
938Boundary wall
939Buildings (including All services i.e. electrical, internal water supply, sanitary works, sewage system, furnishing complete)
940G+4 Quarter
941Water Supply work
942Supply and installation of Deep tubewell, with appropriate depth required to reach aquifer with PVC casing pipe (250 mm diameter minimum), 3 HP submersible mortor pump, 40 mm diameter CPVC column pipe, one unit RCC (M-25 grade) Slow Sand Filter (Capacity 10,000 Ltr/hr) along with RCC (M-25 grade) reservoir 600 mm above FGL (Capacity 35,000 Ltr) Supply and Installation of distribution network with CPVC pipe of 40 mm diameter and 25 mm diameter for connecting to Overhead tank of all buildings.
943Cable Trench along with road crossing culvert for cables wherever necesarry along with switchyard work
944C Type
945D Type
946RCC Box Culvert
947Internal Road (RCC)
948Steps from colony to CRB
949Antiweed treatment
950PCC in Switchyard
951Stone Spreading(Gravelling) in switchyard
952Storm Water Drain
953SUPPLY of Following type tested Lattice type Galvanized steel suspension / Angle tower with stubs and cleats , different type of G.I HT Nuts & Bolts, washer, spring washer for the towers, hanger and all accessories, tower super structure complete including step bolts. Supply of black bituminous paint for three coats up to a height of 500mm above the cooping (legs & bracing members). All Supply should confirm to the Technical Specification.
954DD+6 with Auxiliary cross arm
955Supply of Tower Accessories
956Procurement of Danger plates.
957Procurement of Phase plates.(Set of Three)
958Procurement of Number plates.
959Procurement of anti climbing device
960Procurement of Circuit Plate
961Bird Diverters as per CEA
962Supply of ACSR Conductor
963ACSR Moose conductor
964Supply of Power Conductor Accessories
965Stock bridge type Vibration Damper
966Mid Span Compression Joint for Conductor
967Repair Sleeve for Conductor
968Bundle Spacer suitable for Quad ACSR Moose
969Rigid Spacer for jumper suitable for Quad ACSR Moose
970Supply of Tower earthing Accessories
97150 NB dia, 3 mtr long GI pipe electrode (driven) with test link
97250x6 mm GS flat as required
973Counter Poise Earthing (Per Tower)
974Other earthing accessories like GS steel wires, lugs etc
975Supply of Fibre Optic Cables
97696 Fibre (DWSM) OPGW fibre optic cable
97796 Fibre Optic Approach Cable (DWSM96F)
978Supply of OPGW HARDWARE/FITTINGS AND TERMINATIONS
979OPGW Suspension Assembly
980OPGW double tension pass through assembly
981OPGW Double Tension Assembly for splicing location
982OPGW Tension Single Dead-end Set
983OPGW Vibration Damper c/w pre-formed armour rods
984Down Lead Clamp
985Metallic joint box suitable for 96F OPGW alongwith splice kit for line and sub interface
986Loop bracket
987Supply of FODP
988FODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails
989Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable vizties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
990Supply of Anti Fog Disc Insulator Stack
991Disc insulator suitable for Quad ACSR Moose (400 KV TL)-210 KN
992Disc insulator suitable for Quad ACSR Moose (400 KV TL)-320 KN
993Supply of HARDWARE FITTINGS
994Hardware fittings for Quad ACSR Moose Conductor-Double Suspension String (Pilot) 210x2 kN
995Hardware fittings suitable for Quad ACSR Moose Conductor-Double Tension String 160X4 kN
996F&I of Following type tested Lattice type Galvanized steel suspension / Angle tower with stubs and cleats , different type of G.I HT Nuts & Bolts, washer, spring washer for the towers, hanger and all accessories, tower super structure complete including step bolts. Supply of black bituminous paint for three coats up to a height of 500mm above the cooping (legs & bracing members). All Supply should confirm to the Technical Specification.
997DD+6 with Auxiliary cross arm
998F&I of Tower Accessories
999Procurement of Danger plates.
1000Procurement of Phase plates.(Set of Three)
1001Procurement of Number plates.
1002Procurement of anti climbing device
1003Procurement of Circuit Plate
1004Bird Diverters as per CEA
1005F&I of ACSR Conductor
1006ACSR Moose conductor
1007F&I of Power Conductor Accessories
1008Stock bridge type Vibration Damper
1009Mid Span Compression Joint for Conductor
1010Repair Sleeve for Conductor
1011Bundle Spacer suitable for Quad ACSR Moose
1012Rigid Spacer for jumper suitable for Quad ACSR Moose
1013F&I of Tower earthing Accessories
101450 NB dia, 3 mtr long GI pipe electrode (driven) with test link
101550x6 mm GS flat as required
1016Counter Poise Earthing (Per Tower)
1017Other earthing accessories like GS steel wires, lugs etc
1018F&I of Fibre Optic Cables
101996 Fibre (DWSM) OPGW fibre optic cable
102096 Fibre Optic Approach Cable (DWSM96F)
1021F&I of OPGW HARDWARE/FITTINGS AND TERMINATIONS
1022OPGW Suspension Assembly
1023OPGW double tension pass through assembly
1024OPGW Double Tension Assembly for splicing location
1025OPGW Tension Single Dead-end Set
1026OPGW Vibration Damper c/w pre-formed armour rods
1027Down Lead Clamp
1028Metallic joint box suitable for 96F OPGW alongwith splice kit for line and sub interface
1029Loop bracket
1030F&I of FODP
1031FODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails
1032Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable vizties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
1033F&I of Anti Fog Disc Insulator Stack
1034Disc insulator suitable for Quad ACSR Moose (400 KV TL)-210 KN
1035Disc insulator suitable for Quad ACSR Moose (400 KV TL)-320 KN
1036F&I of HARDWARE FITTINGS
1037Hardware fittings for Quad ACSR Moose Conductor-Double Suspension String (Pilot) 210x2 kN
1038Hardware fittings suitable for Quad ACSR Moose Conductor-Double Tension String 160X4 kN
1039Survey as per Specification
1040Detail Survey
1041Check Survey
1042Concreting of foundation including all Labour, materials, equipment, excavation shuttering, head loading, back filling etc complete for handling, transportation, batching, mixing, placing, levelling, curing etc complete inclusive of cost of cement and reinforcement steel.
1043DD+3 (2Nos.)
1044DD+6 with Auxiliary cross arm (2Nos.)
1045Setting of Stubs
1046Setting of Stubs using adjustable probe (1Set=1No. of Tower)
1047Erection of following type tested lattice type galvanised steel suspension/Angle tower with stubs and cleats, different type of GI HT Nuts & Bolts, washers for the towers, hangers and all accessories, tower superstructure complete including step bolts, Welding of all nuts & bolts up to the bottom cross arm level including all charges of transportation, materials etc.
1048DD+3 (2Nos.)
1049DD+6 with Auxiliary cross arm (2Nos.)
1050Installation/Fitting of Tower Accessories
1051Fitting of Danger plates.
1052Fitting of Phase plates.(Set of Three)
1053Fitting of Number plates.
1054Fitting of anti climbing device
1055Fitting of Circuit Plate
1056Bird Diverters as per CEA
1057Stringingof ACSR Conductor
1058Stringing of power conductors including transportation from Stores and distribution of conductors and accessories to sites and laying, stringing, tensioning , clamping, jointing, jumpering and hoisting of insulators complete including cost of all fittings and accessories not specifically mentioned elsewhere per route Km (Double circuit Tower for Quad Circuit Line) of line.
1059Grounding of towers (Pipe earthing / counterpoise earthing) with 3 metre long 50 mm dia G I pipe along with 50x6 mm GS flat, including cost of all materials, such as GI pipes, GI bolts & nuts and washer, salt, coke etc as per Specification including Soil Resistivity Testing
1060DD+6 with Auxiliary cross arm
1061Protection of Tower
1062Painting of towers with bituminous paints of approved quality up to 5 metres from ground level including the cost of paints. (1No.=1Tower)
1063Erection and Stringing of OPGW CABLE/HARDWARE/FITTINGS AND TERMINATIONS
1064Stringing of 96 Fibre (DWSM)OPGW Fibre Optic cable including transportation and distribution of OPGW and accessories to site and laying, stringing, tensioning , clamping, jointing , complete including all fittings and accessories not specifically mentioned elsewhere per route Km of line alongwith Installation of Hardware set for above 96 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories like suspension assembly, tension assembly, dead end tension assembly at line terminations, tension double end set for splice location, vibration dampers, earthing clamps, down lead clamps, in-line spice enclosures etc.
1065Metallic joint box suitable for 96F OPGW alongwith splice kit for line and sub interface
1066Installation of FODP
1067FODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails
1068Installation of Fibre Optic approach cable (DWSM 96F)
1069Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable vizties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
1070Installation of 96 Fibre (DWSM) Fibre Optic approach cable
1071SUPPLY of Following type tested Lattice type Galvanized steel suspension / Angle tower with stubs and cleats , different type of G.I HT Nuts & Bolts, washer, spring washer for the towers, hanger and all accessories, tower super structure complete including step bolts. Supply of black bituminous paint for three coats up to a height of 500mm above the cooping (legs & bracing members). All Supply should confirm to the Technical Specification.
1072DD+12
1073220kV DD+12
1074220kV DD+18
1075132kV Crossing Gantry
1076Supply of Tower Accessories
1077Procurement of Danger plates.
1078Procurement of Phase plates.(Set of Three)
1079Procurement of Number plates.
1080Procurement of anti climbing device
1081Procurement of Circuit Plate
1082Bird Diverters as per CEA
1083Supply of AAAC Conductor
1084AAAC Panthar conductor
1085Supply of Power Conductor Accessories
1086Stock bridge type Vibration Damper
1087Mid Span Compression Joint for Conductor
1088Repair Sleeve for Conductor
1089Supply of Tower earthing Accessories
109050 NB dia, 3 mtr long GI pipe electrode (driven) with test link
109150x6 mm GS flat as required
1092Counter Poise Earthing (per Tower)
1093Other earthing accessories like GS steel wires, lugs etc
1094Supply of Fibre Optic Cables
109548 Fibre (DWSM) OPGW fibre optic cable
109648 Fibre Optic Approach Cable (DWSM96F)
1097Supply of OPGW HARDWARE/FITTINGS AND TERMINATIONS
1098OPGW Suspension Assembly
1099OPGW double tension pass through assembly
1100OPGW Double Tension Assembly for splicing location
1101OPGW Tension Single Dead-end Set
1102OPGW Vibration Damper c/w pre-formed armour rods
1103Down Lead Clamp
1104Metallic joint box suitable for 48F OPGW alongwith splice kit for line and sub interface
1105Loop bracket
1106Supply of FODP
1107FODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails
1108Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable vizties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
1109Supply of Anti Fog Disc Insulator Stack
1110Disc insulator suitable for Single AAAC Panther (132 KV TL)-70 KN
1111Disc insulator suitable for Single AAAC Panther (132 KV TL)-90 KN
1112Supply of HARDWARE FITTINGS
1113Hardware fittings for Single AAAC Panther Conductor-Single Suspension String 70 kN (Pilot)
1114Hardware fittings suitable for Single AAAC Panther Conductor-Double Tension String 2x90 kN
1115Hardware fittings suitable for Single AAAC Panther Conductor-Single Tension String 90 kN
1116F&I of Following type tested Lattice type Galvanized steel suspension / Angle tower with stubs and cleats , different type of G.I HT Nuts & Bolts, washer, spring washer for the towers, hanger and all accessories, tower super structure complete including step bolts. Supply of black bituminous paint for three coats up to a height of 500mm above the cooping (legs & bracing members). All Supply should confirm to the Technical Specification.
1117DD+12
1118220kV DD+12
1119220kV DD+18
1120132kV Crossing Gantry
1121F&I of Tower Accessories
1122Procurement of Danger plates.
1123Procurement of Phase plates.(Set of Three)
1124Procurement of Number plates.
1125Procurement of anti climbing device
1126Procurement of Circuit Plate
1127Bird Diverters as per CEA
1128F&I of AAAC Conductor
1129AAAC Panthar conductor
1130F&I of Power Conductor Accessories
1131Stock bridge type Vibration Damper
1132Mid Span Compression Joint for Conductor
1133Repair Sleeve for Conductor
1134F&I of Tower earthing Accessories
113550 NB dia, 3 mtr long GI pipe electrode (driven) with test link
113650x6 mm GS flat as required
1137Counter Poise Earthing (per Tower)
1138Other earthing accessories like GS steel wires, lugs etc
1139F&I of Fibre Optic Cables
114048 Fibre (DWSM) OPGW fibre optic cable
114148 Fibre Optic Approach Cable (DWSM96F)
1142F&I of OPGW HARDWARE/FITTINGS AND TERMINATIONS
1143OPGW Suspension Assembly
1144OPGW double tension pass through assembly
1145OPGW Double Tension Assembly for splicing location
1146OPGW Tension Single Dead-end Set
1147OPGW Vibration Damper c/w pre-formed armour rods
1148Down Lead Clamp
1149Metallic joint box suitable for 48F OPGW alongwith splice kit for line and sub interface
1150Loop bracket
1151F&I of FODP
1152FODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails
1153Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable vizties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
1154F&I of Anti Fog Disc Insulator Stack
1155Disc insulator suitable for Single AAAC Panther (132 KV TL)-70 KN
1156Disc insulator suitable for Single AAAC Panther (132 KV TL)-90 KN
1157F&I of HARDWARE FITTINGS
1158Hardware fittings for Single AAAC Panther Conductor-Single Suspension String 70 kN (Pilot)
1159Hardware fittings suitable for Single AAAC Panther Conductor-Double Tension String 2x90 kN
1160Hardware fittings suitable for Single AAAC Panther Conductor-Single Tension String 90 kN
1161Survey as per Specification
1162Detail Survey
1163Check Survey
1164Concreting of foundation including all Labour, materials, equipment, excavation shuttering, head loading, back filling etc complete for handling, transportation, batching, mixing, placing, levelling, curing etc complete inclusive of cost of cement and reinforcement steel.
1165DD+12
1166220kV DD+12
1167220kV DD+18
1168132kV Crossing Gantry
1169Setting of Stubs
1170Setting of Stubs using adjustable probe (1Set=1No. of Tower/Gantry)
1171Erection of following type tested lattice type galvanised steel suspension/Angle tower with stubs and cleats, different type of GI HT Nuts & Bolts, washers for the towers, hangers and all accessories, tower superstructure complete including step bolts, Welding of all nuts & bolts up to the bottom cross arm level including all charges of transportation, materials etc.
1172DD+12
1173220kV DD+12
1174220kV DD+18
1175132kV Crossing Gantry
1176Installation/Fitting of Tower Accessories
1177Fitting of Danger plates.
1178Fitting of Phase plates.(Set of Three)
1179Fitting of Number plates.
1180Fitting of anti climbing device
1181Fitting of Circuit Plate
1182Bird Diverters as per CEA
1183Stringingof ACSR Conductor
1184Stringing of power conductors including transportation from Stores and distribution of conductors and accessories to sites and laying, stringing, tensioning , clamping, jointing, jumpering and hoisting of insulators complete including cost of all fittings and accessories not specifically mentioned elsewhere per route Km (6 conductors for Double Circuit Line) of line.
1185Grounding of towers (Pipe earthing / counterpoise earthing) with 3 metre long 50 mm dia G I pipe along with 50x6 mm GS flat, including cost of all materials, such as GI pipes, GI bolts & nuts and washer, salt, coke etc as per Specification including Soil Resistivity Testing
1186Grounding of towers (Pipe earthing / counterpoise earthing) with 3 metre long 50 mm dia G I pipe along with 50x6 mm GS flat, including cost of all materials, such as GI pipes, GI bolts & nuts and washer, salt, coke etc as per Specification including Soil Resistivity Testing
1187Protection of Tower
1188Painting of towers with bituminous paints of approved quality up to 5 metres from ground level including the cost of paints. (1No.=1Tower/Gantry)
1189Erection and Stringing of OPGW CABLE/HARDWARE/FITTINGS AND TERMINATIONS
1190Stringing of 48 Fibre (DWSM)OPGW Fibre Optic cable including transportation and distribution of OPGW and accessories to site and laying, stringing, tensioning , clamping, jointing , complete including all fittings and accessories not specifically mentioned elsewhere per route Km of line alongwith Installation of Hardware set for above 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories like suspension assembly, tension assembly, dead end tension assembly at line terminations, tension double end set for splice location, vibration dampers, earthing clamps, down lead clamps, in-line spice enclosures etc.
1191Metallic joint box suitable for 48F OPGW alongwith splice kit for line and sub interface
1192Installation of FODP
1193FODP 96F: Indoor Type, rack mounted with FCPC coupling and pig tails
1194Installation of Fibre Optic approach cable (DWSM 96F)
1195Installation hardware set for above 96 Fibre, Fibre Optic Approach Cable vizties/clips/cleats, conduits, ducts, supports, fittings, accessories etc for extending OPGW from sub-station end tower/gantry to FODP at control/ communication room by splicing fibres of OPGW with FOAC in joint box at tower/gantry and splicing FOAC in FODP at control/ communication room.
1196Installation of 48 Fibre (DWSM) Fibre Optic approach cable Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57535763
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 16-10-2026
Authority
Authority Name Assam Electricity Grid Corporation Limited
Work Description Tender for Construction Of New 400/132Kv Umrangshu Grid Substation Along With Associated Transmission System At Dima Hasao District, Assam.
Basic Detail
Tender No AEGCL/MD/Tech-32/400kV Umrangshu/2026/BID
Bidding Type Tender
Location
City Dima Hasao
State Assam
Key Dates
Publish Date 16 Sep 2026
Submission Date 16 Oct 2026
Open Date 17 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee 30000
EMD 11.20 Crore
Exemption Available
Document List
20d6410f-5925-4f5e-a140-bc57702f666c.html
Additinal_Documents.rar
Bid_Volume_I.pdf
Bid_Volume_II.pdf
BOQ_84775.xls
IFB.pdf
Tendernotice_1 (31).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 23 days
Oct 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

20d6410f-5925-4f5e-a140-bc57702f666c.html

rar

Additinal_Documents.rar

pdf

Bid_Volume_I.pdf

pdf

Bid_Volume_II.pdf

xls

BOQ_84775.xls

pdf

IFB.pdf

pdf

Tendernotice_1 (31).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders