Tender For Tender**: Augmentation Of Transformer Capacity At 132 Kv S/S Kashipur, 220 Kv S/S Kamaluaganja, Haldwani, 132 Kv S/S Kathgodam, Haldwani And 132 Kv S/S Kichha In Kumaon Zone Under Package-2
Tender Value
Ref. Documents
Estimated cost
Bid Submission
19 Oct 2026
23 days left
EMD
1.27 Crore
Bank guarantee accepted
Document Fee
29500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Tender**: Augmentation Of Transformer Capacity At 132 Kv S/S Kashipur, 220 Kv S/S Kamaluaganja, Haldwani, 132 Kv S/S Kathgodam, Haldwani And 132 Kv S/S Kichha In Kumaon Zone Under Package-2
BOQ
| Sl. No. | Item Description |
| 1 | Please Enable Macros to View BoQ information Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superitending Engineer (C AND P-II) Name of Work/Tender**: “Augmentation of Transformer capacity at 132 kV S/s Kashipur, 220 kV S/s Kamaluaganja, Haldwani, 132 kV S/s Kathgodam, Haldwani and 132 kV S/s Kichha in kumaon Zone under Package-2” Contract No: PTCUL/E-Tender/C&P-II/SS-06/2026-27 |
| 2 | Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NOTE:- The bidder has to fill the rates/details in green cells only NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sr. No. Particulars Item Code / Make Qty. Unit Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P (without GST) Unit Freight Packing Forwarding Unloading & Stacking Insurance for transit cum 30 days storage RS P (Without GST) VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without GST inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 3 | Price Schedule-A (Supply) for (AUGMENTATION OF TRANSFORMER CAPACITY FROM 3X40MVA TO (2X80+1X40) MVA AT 132 KV SUBSTATION KASHIPUR) |
| 4 | 80 MVA, 132/33kV, Three Phase Transformer including first filling of oil, alongwith Fibre Optic Temperature Measurement System complete with all associated accessories |
| 5 | Nitrogen Injection Fire Prevention & Extinguishing System complete with accessories |
| 6 | Online DGA Multigas For Transformer as per technical specification |
| 7 | 145 KV, 5-Core C.T (1-phase) ,800/400/1 A, accuracy class 02.S without Junction Box |
| 8 | Juction box of 145 KV CT |
| 9 | 120 KV Lightning Arrester (LA) |
| 10 | 132/33 KV Transformer control panel (HV & LV) |
| 11 | 132/33 KV Transformer protection panel (HV &LV) |
| 12 | 145 KV SF-6 Circuit Breaker, 3 Phase along with support structure |
| 13 | 132 KV Isolator for three phase without E/S, 1600 Amp |
| 14 | 36 KV SF-6 Circuit Breaker, 3 Phase |
| 15 | 36 KV CT , 4 core, 1600/800/400/1 A (0.2S accuracy class) without junction box |
| 16 | Juction of 36 KV CT |
| 17 | 30 KV Lightning Arrester (LA) |
| 18 | 36 KV Isolator for three phase without E/S, 1600 Amp |
| 19 | GI Lattice structure including Anchor bolts & GI nuts & bolts. |
| 20 | Control Cable Copper (PVC) |
| 21 | 2X 2.5mm (Armoured) |
| 22 | 4 X 2.5 mm (Armoured) |
| 23 | 6 X 2.5 mm (Armoured) |
| 24 | 10 X 2.5 mm (Armoured) |
| 25 | Control Cable Aluminium (PVC) |
| 26 | 3.5 core, 35sqmm (Armoured) |
| 27 | MS Flat size as per site requirement |
| 28 | 40 mm MS 03 meter electrodes |
| 29 | Flexible copper bond |
| 30 | Insulator strings, Disc Insulators, Hardware, conductor, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for 132/33KV Transformer bay |
| 31 | Insulator strings, Disc Insulators, Hardware, conductor, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for Replacement of 33Kv Bus (for Two Bus) with ACSR Twin Mooose Conductor |
| 32 | Price Schedule-A (Supply of Material) for (AUGMENTATION OF TRANSFORMERS CAPACITY FROM 120 MVA (3×40 MVA) TO 160 MVA (2×40 MVA + 1×80 MVA) AT 220 KV SUBSTATION, KAMALUAGANJA, HALDWANI) |
| 33 | Supply of the following equipments/material as per the approved technicial specifications/drawings/GTP at 220 KV substation Kaamaluaganja, Haldwani |
| 34 | 80 MVA, 132/33 KV, 3-Phase Transformer including Bushings, All Accessories, First Filling of Oil, Online Bushing Monitoring System, Fibre Optic Temperature Measurement System with all associated accessories |
| 35 | Nitrogen Injection Fire Prevention & Extinguishing system for 80 MVA, 132/33 KV, 3-Phase Transformer |
| 36 | Online Dissolve Gas Analysis System (Multi Gas Type) for 80 MVA, 132/33 KV, 3-Phase Transformer |
| 37 | Oil Storage Tank (15 KL) |
| 38 | 145 KV SF6 Circuit Breaker |
| 39 | 145 KV Horizontal Double Break Bus Isolator without Earth Switch |
| 40 | 145 KV Current Transformer, 5-Core, Ratio (800/400/1A), Accuracy Class-0.2S with CT Clamp with Rod Type Bushing (Without thread bushing) |
| 41 | Junction Box for 145 KV CT |
| 42 | 145 KV Potential Transformer (Accuracy Class-0.2) |
| 43 | 145 KV Bus Post Insulator (Soild Core Type) |
| 44 | Junction Box for 145 KV CVT/PT |
| 45 | Transformer Protection Control and Relay Panel with Differential and Restricted Earth Fault Protection (HV & LV) |
| 46 | 120 KV LA (10 KV, Gapless Type) |
| 47 | 33 KV SF6 Circuit Breaker |
| 48 | 33 KV Double Break Bus Isolator without Earthswitch |
| 49 | 30 KV Lightening Arrester |
| 50 | 33 KV CT (1600/800/1A) Rod Type Bushing (Without Thread Bushing) with CT clamp |
| 51 | Junction Box for 33 KV CT/PT |
| 52 | 33 KV Potential Transformer (Accuracy Class-0.2) |
| 53 | 33 KV Bus Post Insulator (Soild Core Type) |
| 54 | ACSR Moose Conductor |
| 55 | Auxiliary Control and Power Cables |
| 56 | 2.5 Sq.mm, 10 Core Armoured Copper Control Cable |
| 57 | 2.5 Sq.mm, 06 Core Armoured Copper Control Cable |
| 58 | 2.5 Sq.mm, 4 Core Armoured Copper Control Cable |
| 59 | 2.5 Sq.mm, 2 Core Armoured Copper Control Cable |
| 60 | Insulator Strings, Disc Insulators, Hardware, Bus Bar Material, Cable Trays, Earthing Material (40 mm MS Rod for Earth Mat and 75×12 mm & 50×6 mm MS Flat for Structure/Equipments Earthing), Bay MB, Clamps, Connectors, Earthwire, etc. for 132 KV Bays & Bus |
| 61 | Insulator Strings, Disc Insulators, Hardware, Bus Bar Material, Cable Trays, Earthing Material (40 mm MS Rod for Earth Mat and 75×12 mm & 50×6 mm MS Flat for Structure/Equipments Earthing), Bay MB, Clamps, Connectors, Earthwire, etc. for 33 KV Bays |
| 62 | Price Schedule-A (Supply of Material) for (AUGMENTATION OF TRANSFORMER CAPACITY FROM 80 MVA (2×40 MVA) TO 160 MVA (2×40 + 1×80 MVA) INCLUDING CONSTRUCTION OF ASSOCIATED 132 KV & 33 KV BAYS AT 132 KV SUBSTATION KATHGODAM, HALDWANI) |
| 63 | Supply of the following equipments/material as per the approved technicial specifications/drawings/GTP at 132 KV substation Kathgodam, Haldwani. |
| 64 | 80 MVA, 132/33 KV, 3-Phase Transformer including Bushings, All Accessories, First Filling of Oil, Online Bushing Monitoring System, Fibre Optic Temperature Measurement System with all associated accessories |
| 65 | Nitrogen Injection Fire Prevention & extinguishing system for 80 MVA, 132/33 KV, 3-Phase Transformer |
| 66 | Online Dissolve Gas Analysis System (Multi Gas Type) for 80 MVA, 132/33 KV, 3-Phase Transformer |
| 67 | Oil Storage Tank (15 KL) |
| 68 | 145 KV SF6 Circuit Breaker |
| 69 | 145 KV Horizontal Double Break Bus Isolator without Earth Switch |
| 70 | 145 KV Current Transformer, 5-Core, Ratio (400/200/1A), Accuracy Class-0.2S with CT Clamp with Rod Type Bushing (Without thread bushing) |
| 71 | Junction Box for 145 KV CT |
| 72 | 145 KV Potential Transformer (Accuracy Class-0.2) |
| 73 | 145 KV Bus Post Insulator (Solid Core Type) |
| 74 | Junction Box for 145 KV CVT/PT |
| 75 | Transformer Protection Control and Relay Panel with Differential and Restricted Earth Fault Protection (HV & LV) |
| 76 | 120 KV LA (10 KV, Gapless Type) |
| 77 | 33 KV SF6 Circuit Breaker |
| 78 | 33 KV Double Break Bus Isolator without Earthswitch |
| 79 | 30 KV Lightening Arrester |
| 80 | 33 KV CT (800/400-1A) Rod Type Bushing (Without Thread Bushing) with CT clamp |
| 81 | Junction Box for 33 KV CT/PT |
| 82 | 33 KV Potential Transformer (Accuracy Class-0.2) |
| 83 | 33 KV Bus Post Insulator (Soild Core Type) |
| 84 | Lattice Type Structure with N&B and Anchor Bolts |
| 85 | Auxiliary Control and Power Cables |
| 86 | 2.5 Sq.mm, 10 Core Armoured Copper Control Cable |
| 87 | 2.5 Sq.mm, 06 Core Armoured Copper Control Cable |
| 88 | 2.5 Sq.mm, 4 Core Armoured Copper Control Cable |
| 89 | 2.5 Sq.mm, 2 Core Armoured Copper Control Cable |
| 90 | Insulator Strings, Disc Insulators, Hardware, Bus Bar Material, ACSR Conductor, Cable Trays, Earthing Material (40 mm MS Rod for Earth Mat and 75×12 mm & 50×6 mm MS Flat for Structure/Equipments Earthing), Bay MB, Clamps, Connectors, Earthwire, etc. for 132 KV Bays |
| 91 | Insulator Strings, Disc Insulators, Hardware, Bus Bar Material, ACSR Conductor, Cable Trays, Earthing Material (40 mm MS Rod for Earth Mat and 75×12 mm & 50×6 mm MS Flat for Structure/Equipments Earthing), Bay MB, Clamps, Connectors, Earthwire, etc. for 33 KV Bays |
| 92 | Price Schedule-A (Supply) for (AUGMENTATION OF TRANSFORMER CAPACITY OF 132 KV SUBSTATION KICHHA FROM 3×40MVA TO 1x80 MVA+2×40 MVA) |
| 93 | Transformers |
| 94 | 80 MVA 132/33 kV, Three Phase Transformer including first filling of oil, alongwith fibre optic Temperature Measurement System complete with all associated accessories. |
| 95 | Online DGA Multigas type |
| 96 | 145 KV SF6 circuit breaker 3 phase along with support structure |
| 97 | Auxiliary Control and Power Cables |
| 98 | 2.5 Sq.mm, 10 Core Armoured Copper Control Cable |
| 99 | 2.5 Sq.mm, 06 Core Armoured Copper Control Cable |
| 100 | 2.5 Sq.mm, 4 Core Armoured Copper Control Cable |
| 101 | 2.5 Sq.mm, 2 Core Armoured Copper Control Cable |
| 102 | Main Earth Mat and Riser (MS Round 40 mm Dia) |
| 103 | 75×12 mm MS Flat |
| 104 | 50×6 mm MS Flat |
| 105 | Steel Structure Lattice Type with Bolts and Nuts |
| 106 | 33 KV Bus & Bay Equipments |
| 107 | 33 KV Lightening Arrester with counter |
| 108 | 33 KV current transformer ( 3-Core ) without junction box |
| 109 | Insulator Strings, Disc Insulators, Hardware, ACSR Moose Conductor, Bus Bar Material, Cable Trays, Bay MB, Clamps, Connectors, Earthwire, Earthing Materials etc. (Transformer Bay of Twin Moose ACSR Conductor and has to be connected with existing 33 kV Main Bus) |
| 110 | 33 KV Bus Post Insulators/ Solid Core Insulator |
| 111 | Steel Structure Lattice Type with Bolts and Nuts Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superitending Engineer (C AND P-II) Name of Work/Tender**: “Augmentation of Transformer capacity at 132 kV S/s Kashipur, 220 kV S/s Kamaluaganja, Haldwani, 132 kV S/s Kathgodam, Haldwani and 132 kV S/s Kichha in kumaon Zone under Package-2” Contract No: PTCUL/E-Tender/C&P-II/SS-06/2026-27 |
| 112 | Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NOTE:- The bidder has to fill the rates/details in green cells only NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SI.No. Description of Material Item Code / Make Qty. Unit Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P (without GST) Unit Freight Packing Forwarding Unloading & Stacking Insurance for transit cum 30 days storage RS P (Without GST) VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without GST inRs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 113 | Price Schedule-B (Erection Work) for (AUGMENTATION OF TRANSFORMER CAPACITY FROM 3X40MVA TO (2X80+1X40) MVA AT 132 KV SUBSTATION KASHIPUR) |
| 114 | Dismantling of old 40 MVA, 132/33 KV transformer and its accessories after draining of its oil in empty drums, opening of all jumpers, disconnection of earth strips and dismantling of its RTCC panel, control & relay panel etc. Filling with nitrogen gas in emptied transformer after vaccumising it. |
| 115 | Dragging, loading, cartage of 40 MVA T/F , T/F oil and its accessories such as RTCC panel, oil drums from 132 KV Sub-station Kashipur yard to desired place. |
| 116 | Erection,testing,commissioning of 80 MVA, 132/33 KV 3 phase power transformer on plinth including cartage of transformer to plinth by dragging , erection of marshalling boxes, electrical connections, centrifuging and filling of oil, erection commissioning of RTCC panel, earthing and other associated works required for proper energization of transformer as per direction of Engineer-in-charge. |
| 117 | Erection,commissioning, testing of Nitrogen Injection Fire Prevention & Extinguishing System and its all accessories complete as per direction of Engineer in charge |
| 118 | Online DGA Multigas For Transformer as per technical specification |
| 119 | Erection of Lattice type structure along with Anchor bolts, nuts & bolts complete |
| 120 | Erection,commissioning, testing of 145 KV CT ,5 Core (1-phase) 800/400/1 A (0.2S accuracy class) with junction box including modification of its base structure as per site requirement as per direction of Engineer in charge. |
| 121 | Erection of 120 KV Lightning arrestor (LA) complete |
| 122 | Testing and commissioning of 145 KV SF-6 circuit breaker including dismatling of old cables and connections. |
| 123 | Erection of 145 KV Isolator for three phase without E/S, 1600 Amp |
| 124 | Erection,commissioning, testing of 36KV SF-6 circuit breaker. |
| 125 | Erection,commissioning, testing of 36KV CT 1600/800/400/1 A (0.2S accuracy class) with junction box as per direction of engineer incharge. |
| 126 | Erection of 30 KV Lightning Arrestor (LA) |
| 127 | Erection of 36 KV Isolator for three phase without E/S, 1600 Amp |
| 128 | Erection,commissioning, testing of 132 KV Transformer control panel (HV & LV) |
| 129 | Erection, commissioning, testing of Transformer protection panel (HV &LV) |
| 130 | Complete laying,ferulling and preparing cable schedule of Armoured Control Cable/Power Cable |
| 131 | 2X 2.5mm (Armoured) |
| 132 | 4 X 2.5 mm (Armoured) |
| 133 | 6 X 2.5 mm (Armoured) |
| 134 | 10 X 2.5 mm (Armoured) |
| 135 | 3.5 core, 35sqmm (Armoured) |
| 136 | Dismentalling of old 132KV / 33KV Bus bar including all jumper, droper of various feeders, gun fittings, disk insulator,clamps etc. |
| 137 | Insulator strings, Disc Insulators, Hardware, conductor, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for 132/33Kv Transformer bay |
| 138 | Earthing of all structures & equipments with MS flat including Painting of all earth strips of all equipments with two coat of green enamel paint after applying one coat of redoxide primer all work as per direction of Engineer-in-charge. |
| 139 | Erection of 40 mm MS 03 meter electrodes |
| 140 | Dismantling of old 145 KV CTs including its safe cartage from switchyard to store at 132 KV Sub-station Kashipur |
| 141 | Dismantling of old 145 KV Isolator including its safe cartage from switchyard to store at 132 KV Sub-station Kashipur |
| 142 | Dismantling of old 145 KV Circuit Breaker including its safe cartage from switchyard to store at 132 KV Sub-station Kashipur |
| 143 | Dismantling of old 120 KV LAs including its safe cartage from switchyard to store at 132 KV Sub-station Kashipur |
| 144 | Dismantling of old 36 KV CTs including its safe cartage from switchyard to store at 132 KV Sub-station Kashipur |
| 145 | Dismantling of old 36 KV Isolator including its safe cartage from switchyard to store at 132 KV Sub-station Kashipur |
| 146 | Dismantling of old 36 KV Circuit Breaker including its safe cartage from switchyard to store at 132 KV Sub-station Kashipur |
| 147 | Dismantling of old 30 KV LAs including its safe cartage from switchyard to store at 132 KV Sub-station Kashipur |
| 148 | Insulator strings, Disc Insulators, Hardware, conductor, bus-bar material, cable trays, Bay MB, clamps, connectors, earthwire, earthing material etc. for Replacement of 33Kv Bus (for Two Bus) with ACSR Twin Mooose Conductor |
| 149 | Price Schedule-B (Civil Work for plinth, foundations ,trenches etc.) |
| 150 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or pits of any size including earth filling, dressing of sides and ramming of bottoms including getting out the excavated soil and disposal of surplus excavated soil as directed,including all heads and lifts. (all kinds of soil) |
| 151 | Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering -All work upto plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 152 | Cement concrete 1:2:4 (1 cement :2 coarse sand:4graded stone aggregate 20mm nominal size ) in pavements, laid to required slope and camber in panels as required including consolidation finishing and timping complete as per direction of engineer in charge. |
| 153 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering , shuttering, finishing and reinforcement -All work upto plinth level1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 154 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level including cost of centering, shuttering, finishing and reinforcement. 1:1:5:3 (1 cement : 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size). |
| 155 | Brick work with common burnt clay F.P.S (non modular) of class designation 7.5 in foundation and plinth in cement mortar 1:4 ( 1 cement : 4 coarse sand). |
| 156 | 12 mm cement plaster of mix 1:4 (1cement : 4 fine sand ) |
| 157 | Structural steel work riveted bolted or welded in built up sections, trusses and framed work, including cutting, hoisting fixing in position applying a priming coat of approved steel primer all complete |
| 158 | Steel reinforcement for RCC work including starightening, cutting , bending, placing in position and binding all complete upto plinth level : Cold twisted bars |
| 159 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 160 | Providing and spreading granular sub base/base/ surface course with local material such as RBM (river bed material) in uniform layer with motor grade on surface, mixing by mix in place method with rotavator and compacting with smooth wheeled roller to achive the desired density. |
| 161 | Supplying and spreading 40 mm (single size) cruched stone aggregate as per IS:383/1970 above the grating as per direction of Engineer-in-charge complete in all respect. |
| 162 | Price Schedule-B (Dismantling, Erection, Testing & Commissioning) for (AUGMENTATION OF TRANSFORMERS CAPACITY FROM 120 MVA (3×40 MVA) TO 160 MVA (2×40 MVA + 1×80 MVA) AT 220 KV SUBSTATION, KAMALUAGANJA, HALDWANI) |
| 163 | Safe and proper dismantling of the following existing/old/unusable equipments/material/auxilary structures as per standard procedures and their loading, unloading, shifting and stacking in store room/designated place including cost of all labour and T&P, complete in all respect as per the direction of the engineer incharge. |
| 164 | 40 MVA, 132/33 KV transformers (1 No.) with its attachments, peropheral & accessories including shifting of them to a suitable place |
| 165 | Nitrogen Injection Fire Prevention & extinguishing system installed on 40 MVA, 132/33 KV, Three-Phase Transformers |
| 166 | 145 KV Circuit Breaker |
| 167 | 145 KV Isolator |
| 168 | 145 KV Current Transformer |
| 169 | 120 KV Lightening Arrestor |
| 170 | Transformer Protection Control and Relay Panel |
| 171 | 33 KV Circuit Breaker |
| 172 | 33 KV Isolator |
| 173 | 33 KV Current Transformer |
| 174 | 30 KV Lightening Arrestor |
| 175 | Safe and proper erection, testing & commissioning of the following equipments/material as per standard erection documents/procedures including cost of all consumables, material, labour and T&P, complete in all respect as per the direction of the engineer incharge. |
| 176 | 80 MVA, 132/33 KV, 3-Phase Transformer including Bushings, All Accessories, First Filling of Oil, Online Bushing Monitoring System, Fibre Optic Temperature Measurement System with all associated accessories |
| 177 | Nitrogen Injection Fire Prevention & extinguishing system for 80 MVA, 132/33 KV, 3-Phase Transformer |
| 178 | Online Dissolve Gas Analysis System (Multi Gas Type) for 80 MVA, 132/33 KV, 3-Phase Transformer |
| 179 | Oil Storage Tank (15 KL) |
| 180 | 145 KV SF6 Circuit Breaker |
| 181 | 145 KV Horizontal Double Break Isolator without Earth Switch |
| 182 | 145 KV Current Transformer, 5-Core, Ratio (800/400/1A), Accuracy Class-0.2S with CT Clamp with Rod Type Bushing (Without thread bushing) and Junction Box |
| 183 | Junection Box for 145 KV CT/CVT/PT |
| 184 | 145 KV Potential Transformer (Accuracy Class-0.2) |
| 185 | 145 KV Bus Post Insulator (Soild Core Type) |
| 186 | Transformer Protection Control and Relay Panel with Differential and Restricted Earth Fault Protection (HV & LV) |
| 187 | 120 KV LA |
| 188 | 33 KV SF6 Circuit Breaker(3-Phase) |
| 189 | 33 KV Double Break Bus Isolator without Earthswitch |
| 190 | 30 KV Lightning Arrester |
| 191 | 33 KV CT (800/400-1A) Rod Type Bushing (without thread bushing ) with CT clamp |
| 192 | 33 KV Potential Trensformer (Accuracy-0.2) |
| 193 | Junection Box for 33 KV CT/PT |
| 194 | 33 KV Bus Post Insulator (Soild Core Type) |
| 195 | 2.5 Sq.mm, 10 Core Armoured Copper Control Cable |
| 196 | 2.5 Sq.mm, 06 Core Armoured Copper Control Cable |
| 197 | 2.5 Sq.mm, 4 Core Armoured Copper Control Cable |
| 198 | 2.5 Sq.mm, 2 Core Armoured Copper Control Cable |
| 199 | Insulator Strings, Disc Insulators, Hardware, Bus Bar Material, ACSR Conductor, Cable Trays, Earthing Material (40 mm MS Rod for Earth Mat and 75×12 mm & 50×6 mm MS Flat for Structure/Equipments Earthing), Bay MB, Clamps, Connectors, Earthwire, etc. for 132 KV Bays & Bus |
| 200 | Insulator Strings, Disc Insulators, Hardware, Bus Bar Material, ACSR Conductor, Cable Trays, Earthing Material (40 mm MS Rod for Earth Mat and 75×12 mm & 50×6 mm MS Flat for Structure/Equipments Earthing), Bay MB, Clamps, Connectors, Earthwire, etc. for 33 KV Bays |
| 201 | Price Schedule-B (Miscellaneous Civil Works) |
| 202 | Earth work in excavation by mechanical or/and manual means in foundations, trenches, pits etc. of any size including dressing of sides and ramming of bottoms in all types of soil and getting out the excavated soil and its disposal to a suitable place including cost of all labour and T&P complete in all respect as per the direction of engineer incharge. |
| 203 | Demolision of old RCC structures/works by mechanical or/and manual means, stacking of reusable steel bars and disposal of unservicable material to a suitable place including cost of all labour and T&P complete in all respect as per the direction of engineer incharge. |
| 204 | Steel reinforcement for RCC work with cold twisted steel bars of suitable sizes as per drawings including straightening, cutting, bending, placing in position and binding including cost of all material, labour and T&P complete in all respect as per the direction of engineer incharge. |
| 205 | Structural steel works of riveted, bolted or welded types in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer including cost of all material, labour and T&P complete in all respect as per the direction of engineer incharge. |
| 206 | Providing and laying in position specified grade of reinforced cement concrete, including the cost of centering, shuttering, finishing and reinforcement with all works up to plinth level in the following ratios of cement, coarse sand and 20 mm nominal size aggregate including cost of all material, labour and T&P complete in all respect as per the direction of engineer incharge. |
| 207 | Cement, Coarse Sand & 20 mm Aggregate Ratio 1:4:8 |
| 208 | Cement, Coarse Sand & 20 mm Aggregate Ratio 1:2:4 |
| 209 | Cement, Coarse Sand & 20 mm Aggregate Ratio 1:1.5:3 |
| 210 | Brick work with common burnt clay FPS bricks of class designation 7.5 conforming to IS 1007-1992 in superstructures i.e. in foundations and above plinth level with cement mortar 1:4 (1 cement:4 coarse sand) including cost of all material, labour and T&P complete in all respect as per the direction of engineer incharge. |
| 211 | Plaster work in 12 mm thickness with cement plaster of mix 1:4 (1 cement:4 fine sand) |
| 212 | Price Schedule-B (Erection, Testing & Commissioning) for (AUGMENTATION OF TRANSFORMER CAPACITY FROM 80 MVA (2×40 MVA) TO 160 MVA (2×40 + 1×80 MVA) INCLUDING CONSTRUCTION OF ASSOCIATED 132 KV & 33 KV BAYS AT 132 KV SUBSTATION KATHGODAM, HALDWANI) |
| 213 | Safe and proper erection, testing & commissioning of the following equipments/material as per standard erection documents/procedures including cost of all consumables, material, labour and T&P, complete in all respect as per the direction of the engineer incharge. |
| 214 | 80 MVA, 132/33 KV, 3-Phase Transformer including Bushings, All Accessories, First Filling of Oil, Online Bushing Monitoring System, Fibre Optic Temperature Measurement System with all associated accessories |
| 215 | Nitrogen Injection Fire Prevention & extinguishing system for 80 MVA, 132/33 KV, 3-Phase Transformer |
| 216 | Online Dissolve Gas Analysis System (Multi Gas Type) for 80 MVA, 132/33 KV, 3-Phase Transformer |
| 217 | Oil Storage Tank (15 KL) |
| 218 | 145 KV SF6 Circuit Breaker |
| 219 | 145 KV Horizontal Double Break Isolator without Earth Switch |
| 220 | 145 KV Current Transformer, 5-Core, Ratio (400/200/1A), Accuracy Class-0.2S with CT Clamp with Rod Type Bushing (Without thread bushing) and Junction Box |
| 221 | Junection Box for 145 KV CT/CVT/PT |
| 222 | 145 KV Potential Transformer (Accuracy Class-0.2) |
| 223 | 145 KV Bus Post Insulator (Soild Core Type) |
| 224 | Transformer Protection Control and Relay Panel with Differential and Restricted Earth Fault Protection (HV & LV) |
| 225 | 120 KV LA |
| 226 | 33 KV SF6 Circuit Breaker(3-Phase) |
| 227 | 33 KV Double Break Bus Isolator without Earthswitch |
| 228 | 30 KV Lightning Arrester |
| 229 | 33 KV CT (800/400-1A) Rod Type Bushing (without thread bushing ) with CT clamp |
| 230 | 33 KV Potential Trensformer (Accuracy-0.2) |
| 231 | Junection Box for 33 KV CT/PT |
| 232 | 33 KV Bus Post Insulator (Soild Core Type) |
| 233 | Lattice Type Structure with N&B and Anchor Bolts |
| 234 | Auxiliary Control and Power Cables |
| 235 | 2.5 Sq.mm, 10 Core Armoured Copper Control Cable |
| 236 | 2.5 Sq.mm, 06 Core Armoured Copper Control Cable |
| 237 | 2.5 Sq.mm, 4 Core Armoured Copper Control Cable |
| 238 | 2.5 Sq.mm, 2 Core Armoured Copper Control Cable |
| 239 | Insulator Strings, Disc Insulators, Hardware, Bus Bar Material, ACSR Conductor, Cable Trays, Earthing Material (40 mm MS Rod for Earth Mat and 75×12 mm & 50×6 mm MS Flat for Structure/Equipments Earthing), Bay MB, Clamps, Connectors, Earthwire, etc. for 132 KV Bays |
| 240 | Insulator Strings, Disc Insulators, Hardware, Bus Bar Material, ACSR Conductor, Cable Trays, Earthing Material (40 mm MS Rod for Earth Mat and 75×12 mm & 50×6 mm MS Flat for Structure/Equipments Earthing), Bay MB, Clamps, Connectors, Earthwire, etc. for 33 KV Bays |
| 241 | Price Schedule-B (Miscellaneous Civil Works) |
| 242 | Earth work in excavation by mechanical or/and manual means in foundations, trenches, pits etc. of any size including dressing of sides and ramming of bottoms in all types of soil and getting out the excavated soil and its disposal to a suitable place including cost of all labour and T&P complete in all respect as per the direction of engineer incharge. |
| 243 | Demolision of old RCC structures/works by mechanical or/and manual means, stacking of reusable steel bars and disposal of unservicable material to a suitable place including cost of all labour and T&P complete in all respect as per the direction of engineer incharge. |
| 244 | Steel reinforcement for RCC work with cold twisted steel bars of suitable sizes as per drawings including straightening, cutting, bending, placing in position and binding including cost of all material, labour and T&P complete in all respect as per the direction of engineer incharge. |
| 245 | Structural steel works of riveted, bolted or welded types in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer including cost of all material, labour and T&P complete in all respect as per the direction of engineer incharge. |
| 246 | Providing and laying in position specified grade of reinforced cement concrete, including the cost of centering, shuttering, finishing and reinforcement with all works up to plinth level in the following ratios of cement, coarse sand and 20 mm nominal size aggregate including cost of all material, labour and T&P complete in all respect as per the direction of engineer incharge. |
| 247 | Cement, Coarse Sand & 20 mm Aggregate Ratio 1:4:8 |
| 248 | Cement, Coarse Sand & 20 mm Aggregate Ratio 1:2:4 |
| 249 | Cement, Coarse Sand & 20 mm Aggregate Ratio 1:1.5:3 |
| 250 | Brick work with common burnt clay FPS bricks of class designation 7.5 conforming to IS 1007-1992 in superstructures i.e. in foundations and above plinth level with cement mortar 1:4 (1 cement:4 coarse sand) including cost of all material, labour and T&P complete in all respect as per the direction of engineer incharge. |
| 251 | Plaster work in 12 mm thickness with cement plaster of mix 1:4 (1 cement:4 fine sand) |
| 252 | Price Schedule-B ( Erection) (AUGMENTATION OF TRANSFORMER CAPACITY OF 132 KV SUBSTATION KICHHA FROM 3×40MVA TO 1x80 MVA+2×40 MVA) |
| 253 | 80 MVA 132/33 kV, Three Phase Transformer including first filling of oil, alongwith fibre optic Temperature Measurement System complete with all associated accessories. |
| 254 | Online DGA Multigas type |
| 255 | 145 KV SF6 circuit breaker 3 phase along with support structure |
| 256 | Auxiliary Control and Power Cables |
| 257 | 2.5 Sq.mm, 10 Core Armoured Copper Control Cable |
| 258 | 2.5 Sq.mm, 06 Core Armoured Copper Control Cable |
| 259 | 2.5 Sq.mm, 4 Core Armoured Copper Control Cable |
| 260 | 2.5 Sq.mm, 2 Core Armoured Copper Control Cable |
| 261 | Main Earth Mat and Riser (MS Round 40 mm Dia) |
| 262 | 75×12 mm MS Flat |
| 263 | 50×6 mm MS Flat |
| 264 | Steel Structure Lattice Type with Bolts and Nuts |
| 265 | Nitrogen Injection Fire Prevention and Extinguishing System for Transformer |
| 266 | 33 KV Bus & Bay Equipments |
| 267 | 33 KV Lightening Arrester with counter |
| 268 | 33 KV current transformer ( 3-Core ) without junction box |
| 269 | Insulator Strings, Disc Insulators, Hardware, ACSR Moose Conductor, Bus Bar Material, Cable Trays, Bay MB, Clamps, Connectors, Earthwire, Earthing Materials etc. (Transformer Bay of Twin Moose ACSR Conductor and has to be connected with existing 33 kV Main Bus) |
| 270 | 33 KV Bus Post Insulators/ Solid Core Insulator |
| 271 | Steel Structure Lattice Type with Bolts and Nuts |
| 272 | Dismantling and re-erection |
| 273 | 132 kV Surge Arrester (Dismantling) |
| 274 | 132 kV Surge Arrester (Erection) |
| 275 | 33 kV Surge Arrester |
| 276 | Lattice structure |
| 277 | Dismantling of 132 /33 KV 40 MVA power transformer including all associated accesories from 132 KV/ 33 KV substation Kichha inside the substation shifting as per the instruction of engineer in charge. including cost of dismantaling, loading, unloading, cartage, labour , T&P etc. complete in all respect. |
| 278 | 40 MVA 132/33 kV, Three Phase Transformer including first filling of oil, alongwith fibre optic Temperature Measurement System complete with all associated accessories at 132 KV/ 33 KV substation Kichha including shifting upto the plinth, erection, testing and commissioning as per technical specification. |
| 279 | Price Schedule-B (Civil) |
| 280 | Foundation of Transformer |
| 281 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m disposed soil to be leveled and neatly dressed. (all kinds of soil) |
| 282 | Cement concrete 1:4:8 (1 cement :4 coarse sand:8 graded stone aggregate 40mm nominal size ) in pavements, laid to required slope and camber in panels as required including consolidation finishing and timping complete. |
| 283 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level including cost of centering, shuttering, finishing and reinforcement. 1:1:5:3 (1 cement : 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size). |
| 284 | Brick work with machine perforated bricks of class designation 125 conforming to IS 2222- 1991 in superstructure above plinth level up to floor five level in cement mortar 1:4 ( 1 cement : 4 coarse sand) With F.P.S. bricks. |
| 285 | 12 mm cement plaster of mix 1:4 (1cement : 4 fine sand ) |
| 286 | Steel reinforsement for RCC work and angle required for cable trench etc including straightening, cutting, bending, placing in position, and binding, welding etc.(including Supply) |
| 287 | Foundation of structures |
| 288 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m disposed soil to be leveled and neatly dressed. (all kinds of soil) |
| 289 | Cement concrete 1:4:8 (1 cement :4 coarse sand:8 graded stone aggregate 40mm nominal size ) in pavements, laid to required slope and camber in panels as required including consolidation finishing and timping complete. |
| 290 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level including cost of centering, shuttering, finishing and reinforcement. 1:1.5:3 (1 cement : 1.5 coarse sand 3 graded stone aggregate 20 mm nominal size). |
| 291 | Brick work with machine perforated bricks of class designation 125 conforming to IS 2222- 1991 in superstructure above plinth level up to floor five level in cement mortar 1:4 ( 1 cement : 4 coarse sand) With F.P.S. bricks. |
| 292 | 12 mm cement plaster of mix 1:4 (1cement : 4 fine sand ) |
| 293 | Steel reinforsement for RCC work and angle required for cable trench etc including straightening, cutting, bending, placing in position, and binding, welding etc.(including Supply) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Superitending Engineer (C AND P-II) Name of Work/Tender**: “Augmentation of Transformer capacity at 132 kV S/s Kashipur, 220 kV S/s Kamaluaganja, Haldwani, 132 kV S/s Kathgodam, Haldwani and 132 kV S/s Kichha in kumaon Zone under Package-2” Contract No: PTCUL/E-Tender/C&P-II/SS-06/2026-27 |
| 294 | Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) * Tender is of composite nature comprising of supply of goods and supply of services NOTE:- The bidder has to fill the GST AMOUNT on The green cells of AMOUNT COLOUM(4) ONLY. In case any discrepancy is observed in amount carried from BoQ1 & BoQ2 sheet as below, the value given in BoQ1 & BoQ2 sheet shall prevail. NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Particulars Item Code / Make Quantity Units Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Pleas Enter ZERO Only AMOUNT VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 295 | Total Price Schedule-A (Supply) from BoQ1 sheet WITHOUT GST |
| 296 | Total Price Schedule-B ( Erection , Dismantling, Testing & Commissioning and Misc. Civil Works ) from BoQ2 sheet WITHOUT GST |
| 297 | Add GST* Amount on (Total of Price Schedule-A + Total of Price Schedule-B above) Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only |
AI Tender Summary
Tender Timeline
Sep 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 23 daysOct 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender