Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #57535065

Tender For Repair Maintenance Of Geyser /Solar Water Heater And Day To Day Complaints And Misc Fittings Fixture At Amritsar Cantt

Issued by Statutory Bodies & Commissions/Committees · Amritsar, Punjab
Tender Value
25 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
11 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Amritsar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Maintenance Of Geyser /Solar Water Heater And Day To Day Complaints And Misc Fittings Fixture At Amritsar Cantt

BOQ

Name of Work:- REPAIR MAINT OF GEYSER /SOLAR WATER HEATER AND DAY TO DAY COMPLAINTS AND MISC FITTINGS FIXTURE AT AMRITSAR CANTT
Sl. No. Item Description
1Attending of day to day geyser and solar complaints pertaining to winter appliances received in person on detailment at MES Service centre located at Old Amritsar Cantt Area by locating and rectification for geysers shock, sparking in geyser wiring , geyser not working etc fault from and Inspection taking down, opening, dismantling , descaling, replacing unserviceable items brushing and cleaning of storage tank and examining of water tightness of storage tank after cleaning and descaling and refixing in position complete all as specified and directed.Note - (i) The item required for replacement shall be paid separtely under respective schdule item has supply only. (ii) Necessary tools for tradesman shall be provided by the contractor. (iii) Complaints of normal nature shall be attended and rectified within 8Hrs of receipt of complaint. However, complaints of emergent nature i.e short circuit, earth fault etc shall be attended immediately on receipt of complaint round the clock. (iv) Contractor will deposit all the items to EM Store in advance and unsv items will be collected by the contractor as schedule of credit. (v) Electrician will report to AGE EM complaint cell at 9 O'Clock daily for collecting of complaints. Complaint received shall be rectified in the same day and after completion of complaint Electrician will report to complain cell for the completion report. (vi) Contractor deploy local electrician for the job so that urgent nature of complaint like noshort circuit and earth fault will also done on Holidays/ Sunday. (vii) For Non attending of urgent nature complaint within 24 hours a penalty of 100 RS/per day/per complaint will be levied on contractor.
2Supply only heating element of geyser ISI Marked any type (Triangular/Rond cup , square etc. as per sample) 2 KW Capacity of INCOLOY material (petty item such as nut ,bolt, clamps etc are deemed to be included in unit rate) complete all as specified and directed.Make:- Racold/theeta/ Havells
3Supply only heating element of geyser ISI Marked any type (Triangular/Rond cup, square etc as per sample.) 1.5 KW Capacity of INCOLOY material (petty item such as nut ,bolt, clamps etc are deemed to be included in unit rate) complete all as specified and directed.Make:- Racold/theeta/ Havells
4Supply only thermostat as per sample ISI marked for geyser any capacity all as specified and directed.Make:- Usha/Racold/Envy or equivalent ISI Marked
5Supply only thermal cut out as per sample ISI marked for geyser any capacity complete all as specified and directed.Make:- Havells/Racold/Usha or equivalent ISI Marked
6Supply only indicator lamp as per sample to geyser of any size and shape complete all as specified and directed.
7Supply only inner shell as per sample of suitable size made of stainless steel sheet of Fe 305 22 SWG ISI Marked can bear pressuure upto 0.8 MPa suitable for geyser of any type/Make and 25 litres capacity complete with all suitable accessories such as thermal insulation etc complete all as specified and directed as per sample.
8Supply only inner shell as per sample of suitable size made of stainless steel sheet of Fe 305 22 SWG ISI Marked can bear pressuure upto 0.8MPa suitable for geyser of any type/Make and 50 litres capacity complete with all suitable accessories such as thermal insulation etc complete all as specified and directed as per sample.
9Supply only inner base assembly as per sample complete with inlet ,outlet, thermostat pipes with drain plug and screw including clamps for holding the elements, nuts, bolt ,washer etc, ISI Marked for geyser of any type/Make and 25/50 litres capacity complete all as specified and directed.
10Supply and fixing in replacement of copper wire, 3 core, flexible type of size 2.5 sqmm etc complete all as specified and directed.
11Supply only bottom cover plate (two halves) and fix with new bottom cover plate with matching colour of geysers of any type/Make and capacity complete all as speclfisd and directed.
12Supply only new multifunction valve(NRV) ISI marked made of cast copper alloy screwed both ends internally suitable for iron pipe of size 15mm complete all as specified and directed.
13Supply only safety pressure valve with vent to geyser as per latest ISI specification complete all as specified and directed.
14Material and labour for PVC connection suitable for hot water of size 15 mm x 600 mm long superior quality for geyser complete with brass adopter for geyser of any capacity complete all as specified and directed.Make : Prayag/shakti.
15M&L for Brazing / welding of inner tank at leaking spots up to five leakage of geyser of capacity 25/50 ltrs of any type and make of tank after checking up worn out nuts bolts and washers complete all as specified and directed.
16Supply and fixing in replacement of brass chormium plated angle valve, fancy type of size 15mm dia screwed down for high pressure, complete all as specified and directed.
17Supply and fixing in replacement of sheet metal enclosure (industrial type DB) complete in 2P+E configuration with plug and socket complete with one MCB SP B Curve type of capacity 20 Amp 10 KA complete all as specified and directed.
18Material and labour for grouting of nuts & Tee bolts as directed for fixing of 50/25 Itrs capacity geyser including cement work and colour matching on existing wall complete all as specified and directed.
19S & F in replacement of 16 Amp plug top with indicator complete all as specified and directed.Make Anchor /Havells/Plaza
20S & F Socket 16 Amp multipurpose shutter type fixed on laminated sheet top cover complete all as specified and directed.
21S & F Switch 16 Amp fixed on laminated sheet top cover complete all as specified and directed.
22Supply and fixing in replacement Brass chromium plated fancy type bib tabs of size 15 mm dia bore short body, screwed down for GI pipe or for brass ferrule and fixed complete all as specified and directed.
23Supply and Fixing in replacement BEE 5 star rated Storage water heater (Geyser) of 25 litre capacity 230V AC, 50HZ as per IS -2082:1993 having 2 KW INCOLOY glass coated element with ABS shock proof and rust proof outer body,high density PUF insulation 35 mm , MS Tank with glasslined coating from inside which can sustain pressure of minimum 8 Bar working pressure , class -I , vertical type with adjustable thermostate and thermal cutout capillary type , Magnesium anode 150 mm and dia 18mm ,Adjustable temperature control knob , FR garde electric cable with ISI mark plug top and having multifunction safety valve, making electric and water connection complete all as specified and directed.
24Supply and Fixing in replacement BEE 5 star rated Storage water heater (Geyser) of 50 litre capacity 230V AC, 50HZ as per IS -2082:1993 having 2 KW INCOLOY glass coated element with ABS shock proof and rust proof outer body,high density PUF insulation 35 mm , MS Tank with glasslined coating from inside which can sustain pressure of minimum 8 Bar working pressure , class -I , vertical type with adjustable thermostate and thermal cutout capillary type , Magnesium anode 150 mm and dia 18mm ,Adjustable temperature control knob , FR garde electric cable with ISI mark plug top and having multifunction safety valve, making electric and water connection complete all as specified and directed.
25M & L for sub main wiring with 1100 volt grade two single core PVC insulated and unsheathed cable with stranded copper conductor 4.0 sqmm drawn into and including electrical grade PVC conduit medium grade not less than 20 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 2.5 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed.Note:- Two runs of 4 sqmm main cable one run of 2.5 sqmm including one run of PVC Conduit for measurement one running metre.
26SOLAR WATER HEATING SYSTEM Disconnecting electrical connection and water connection of solar heating device carefully dismantling solar panel with water tube (copper assembly/ETC tube) rubber gasket; nut bolt; biding aluminum channel and glass carefully and servicing/Descaling/cleanning with acid & water circulation and wire brush and brazing of cooper tube checking of leakage if any . After servicing reassemble the same and testing of solar water heater complete all as specified and directed.
27Supply and fixing in replacement of gas kit set for ETC tube All as specified and directed.
28Supply and fixing in replacement of ETC tube holder without cups .All as specified and directed.
29Supply and fixing in replacement of solar evacuated tube of solar water heater as per existing suitable for 300/ 500 LPD , complete with washer etc complete all as specified and directed.Make - Solar Maxx/inter solar/Tata BP Solar
30Supply and fixing in replacement of aluminium foil for solar collector All as specified and directed.
31Supply and fixing in replacement of rubber grommet (for collector) complete all as specified and directed.Make : Inter Solar, Sintex, sun magic are equivalent make in market.
32Supply and fixing in replacement of MS dead flange complete all as specified and directed.
33Supply and fixing in replacement of hose pipe for collector (hot and cold)with round clamp complete all as specified and directed.
34Supply and fixing in replacement of brass flange complete all as specified and directed.
35Supply and fixing in replacement of Toughened/ tempered glass for solar collector having 4 mm thickness transmissivity more than 85 %.as per existing size complete all as specified and directed.
36Supply and fixing in replacement of heating element INCOLOY type for water heating system 3 KW as per sample ISI Marked with rubber gasket of suitable Sizecomplete all as specified and directed.Make: Racold/inter solar
37Supply and fixing in replacement of thermostate ISI marked suitable for solar heater complete all as specified and directed.
38Dismantling the complete assembly of solar hot water tank in replacement of supply and fixing 500 ltrs pre insulated hot water storage tank with stand (inner tank SS 304 ) removing insulated fixtures including all inlet outlet connections testing the leakages with compressed air, reshaping the squeezed portion of its original shape,filling of leak points with brazing /organ welding and reclading,connecting the removed water lines,testing of solar hot water tank complete all as specified and directed.
39Dismantling the complete assembly of solar hot water tank in replacement of supply and fixing 300 ltrs pre insulated hot water storage tank with stand (inner tank SS 304 ) removing insulated fixtures including all inlet outlet connections testing the leakages with compressed air, reshaping the squeezed portion of its original shape,filling of leak points with brazing /organ welding and reclading,connecting the removed water lines,testing of solar hot water tank complete all as specified and directed.
40Suppply and fixing GI Pipe size 25 MM dia med grade galvanised with all fitting complete all as specified and directed.
41Suppply and fixing GI Pipe size 20 MM dia med grade galvanised with all fitting complete all as specified and directed.
42Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of size 20 mm dia complete all as specified and directed.
43Suppply and fixing CPVC Pipe size 25 MM dia suitable for hot water with all fitting complete all as specified and directed.
44Suply and fixing gate valve gun metal with iron wheel head, screwed both ends for iron pipe and fixed size 25 mm dia complete all as specified and directed.
45Suply and fixing gate valve gun metal with iron wheel head, screwed both ends for iron pipe and fixed size 20 mm dia complete all as specified and directed.
46Supply and fixing Switch Socket Combined with Box 6/16Amp | Heavy Duty Product ISI Approval complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57535065
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 25 Lakhs
LAST DATE 06-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair Maintenance Of Geyser /Solar Water Heater And Day To Day Complaints And Misc Fittings Fixture At Amritsar Cantt
Basic Detail
Tender No GE/ASR-75/2026-27
Bidding Type Tender
Location
City Amritsar
State Punjab
Key Dates
Publish Date 15 Sep 2026
Submission Date 06 Oct 2026
Open Date 13 Oct 2026
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Available
Document List
02113ac6-28c2-47b2-a034-bf8519dbb445.html
BOQ_884984.xls
TENDER75.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

02113ac6-28c2-47b2-a034-bf8519dbb445.html

xls

BOQ_884984.xls

pdf

TENDER75.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders