Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #57533778

Tender For Repair Of Hsvp Office Building Sector-19 Hsvp, Kaithal (Balance Work) Providing And Applying Paint, Plaster, Polishing, Brick Work, Tile, Granite Etc Complete In All Respect. Including Three Year Mtc/ Defect Liability Period Free Of Cost A

Issued by Local Bodies · Karnal, Haryana
Tender Value
37.63 Lakhs
Estimated cost
Bid Submission
22 Sep 2026
0 days left
EMD
75260
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Karnal → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Of Hsvp Office Building Sector-19 Hsvp, Kaithal (Balance Work) Providing And Applying Paint, Plaster, Polishing, Brick Work, Tile, Granite Etc Complete In All Respect. Including Three Year Mtc/ Defect Liability Period Free Of Cost Ac Rs 37.63 Lacs

BOQ

Name of Work:- Repair of HSVP Office Building Sector-19 HSVP, Kaithal (Balance work) providing and applying Paint, Plaster, Polishing, Brick Work, Tile, Granite etc complete in all respect. Including three year mtc/ defect liability period free of cost AC Rs 37.63 Lacs
Sl. No. Item Description
1[11.15]6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge. [Through Rate]
2[11.94.1]Finishing walls with textured exterior paint of required shade : 1. New work (Two or more coats applied @ 3.28 litre/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm [Through Rate]
3[13.10.1]Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1. 4.0 mm thick glass panes [Through Rate]
4[13.41]Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). [Through Rate]
5[15.1.1.1]Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material as per clause 304 of MORTandH specifications Ordinary soil 1.1. Manual Means Depth up to 3 m [Through Rate]
6[17.70]Removal of existing IPB by manual means and disposal of dismantled material with all lead and lift as per technical specification clause 202.3. [Through Rate]
7[17.71]Relaying of available (removed and stacked) Interlocking Paver Block Pavement having thickness 100mm/80 mm/ 60 mm (average = 80mm) as per drawings and Technical Specification Clause 1504 [Through Rate]
8[22.103.1]Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 1. 15 mm nominal bore [Through Rate]
9[22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate]
10[22.105.1]Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore [Through Rate]
11[22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore [Through Rate]
12[22.14.2.2]Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 2.2. Flexible pipe 40 mm dia [Through Rate]
13[22.222.2.1]Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. 2.1. Single Socket Type B 160mm o/d SWR UPVC pipe lines laid complete [Through Rate]
14[23.28.8.6]Supplying, installation, Testing and Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency )85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short and Open circuit protection,THD ( 10% , P. F.=0.95, IP20, CRI )80, UGR (Unified Glare Rating) ( 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver and electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 6. Powder coated die cast / Extruded aluminium Body (Thickness >= 1.20 mm) 45 watt [Rate]
15[28.11]`Supplying and installing 1.5 mm thick SBS membrane, self-adhesive polymer modified bitumen comprising of a cross laminated HDPE carrier film. Membrane shall come with a BBA certification giving a durability of membrane up to the life of the structure and shall have Tensile Strength : L: 215N/50mm T: 220N/50mm ( as per BS EN12311-1), Elongation : L: 324% and T: 238% (as per BS EN12311-1), Water Vapour Permeability : Impermeable to ISO 12572 (as per BS EN 1931), Resistance to Hydrostatic Head: Min 60m( as per ASTM D5385), Adhesion to primed concrete : 4.9mm (as per ASTM D1000). The surface shall be primed using Bituminous Primer and membrane shall be installed with an edge lap of 50 mm and end lap of 150 mm. Membrane Termination shall be done by providing a groove cut of 30mm x 30mm, put the membrane inside the groove, nailing of aluminium flashing at 200mm c/c and sealing with a suitable PU Sealant at the termination of waterproofing membrane at minimum of 300mm height on the vertical wall, as per the manufacturer’s Specification. Membrane shall be protected using 8mm thick dimple board for protection as per manufacturer`s recommendation followed by backfilling. The rates are inclusive of surface preparation, crack filling, injection grouting at honeycombed areas, coving, priming all complete as per manufacturer methodology but excluding for protection board.` [Through Rate]
16[28.9]`Supplying and installing positive side waterproofing treatment for `Raft Slab` using 4-5mm thick blended polyethylene / polypropylene membrane incorporating a cell mesh, enabling the membrane to mechanically bond with the poured concrete. The membrane shall be supplied with one self-adhesive selvedge to provide sealed laps and comply with British Standard 8102 2009. Membrane shall have 125 years of certificate of durability and Water tightness test.The membrane should have the following typical properties : 1. Resistance to static loading (EN 12730 method B): 15 Kg2. Tensile Strength (EN 12311-2): L: )18MPa, T: )10MPa 3. Elongation at break (EN 12311-2): L: )800%, T: )600% 4. Elongation at peak load (EN 12311-2): L: )800%, T: )600%5. Crack Bridging (ASTM C1305): up to 5mm (100 cycles) 6. Durability of water tightness against durability (EN 1296/ EN 1928): Pass 7. Resistance to impact (EN 12691 Method A): 1500mm 8. Puncture Resistance (ASTM E154-08): 672N 9. Resistance to tear (nail shank): EN 12310-1): 720N (Longitudinal) 10. Reaction to fire (EN ISO 11925-2): Pass 11. Joint Strength (EN 12317-2): =220N (Lap) and =150N (Butt) 12. Resistance to Alkali(EN 1847/EN 1928)-Pass Membrane shall be installed over the entire PCC area with standard 80 mm selvedge laps and end laps overlaid as per manufacturer`s instructions. The rates are inclusive of supply and installation of membrane as per manufacturer methodology. The rates are inclusive of surface preparation, injection grouting at honeycombed areas all complete as per manufacturer methodology. ` [Through Rate]
17[4.14.1]Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1. All kinds of soil. [Through Rate]
18[5.30.1]Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : 1. Of area 3 sq. metres and below [Through Rate]
19[6.1.2]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 2. 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) [Through Rate]
20[6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) [Through Rate]
21[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate]
22[6.34.3]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 3. Cold twisted bars [Through Rate]
23[7.21.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
24[8.26.2.2]Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 2.2. Granite of any colour and shade Area of slab over 0.50 sqm [Through Rate]
25[9.50.1]Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main `T` runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross `T` of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main `T` at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross `T` of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main `T` runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 1. 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fibre manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rock wool of 48 kg /cum backing. [Through Rate]
26Analysis for rates for Providing and fixing 3 Stages Commercial Water Filtration System ISI marked with 50 Litre discharge capacity complete in all respect as desired by Engineer-in-charge.
27Analysis for rates for Providing and fixing Stainless Steel Water Chiller/Cooler ISI marked with 150/170 cooling capacity complete in all respect as desired by Engineer-in-charge.
28Analysis for rates for Providing and fixing 3 Stages Commercial Water Filtration System ISI marked with 50 Litre discharge capacity complete in all respect as desired by Engineer-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57533778
AUTHORITY Local Bodies
TENDER VALUE 37.63 Lakhs
LAST DATE 22-09-2026
Authority
Authority Name Haryana Urban Development Authority
Work Description Tender for Repair Of Hsvp Office Building Sector-19 Hsvp, Kaithal (Balance Work) Providing And Applying Paint, Plaster, Polishing, Brick Work, Tile, Granite Etc Complete In All Respect. Including Three Year Mtc/ Defect Liability Period Free Of Cost Ac Rs 37.63 Lacs
Basic Detail
Tender No 2026F893D847 468C 4B11 8A56 E12A2F762539240HSV
Bidding Type Tender
Location
City Karnal
State Haryana
Key Dates
Publish Date 16 Sep 2026
Submission Date 22 Sep 2026
Open Date 24 Sep 2026
Finance
Tender Value 37.63 Lakhs
Tender Fee 1000
EMD 75260
Exemption Available
Document List
65f1f0a9-526f-41e0-90d0-6a5d351d71ed.html
BOQ_627690.xls
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Sep 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

65f1f0a9-526f-41e0-90d0-6a5d351d71ed.html

xls

BOQ_627690.xls

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders