Tender For Special Repair To Bldg No P-08 In Otm-I At Lgj Mil Stn
Tender Value
1.40 Crore
Estimated cost
Bid Submission
06 Oct 2026
2 days left
EMD
2.15 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
bathinda → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Bldg No P-08 In Otm-I At Lgj Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Taking down existing roof treatment of any description such as PCC, lime concrete, mud phuska, APP membrane etc. and any numbers of layers upto any thickness from roof including scraping and roughening old by picking, sweeping clean and washing down and removing debris outside MD land complete all as specified and directed by Engineer-in-Charge. |
| 2 | M & L for PCC 1:2:4 type B-0 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate mixed with water proofing compound as levelling course of roof padding finished even and fair complete all as specified and directed by Engineer-in-Charge. Note:- Water proofing compound shall be measured and paid for separately complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supply only Liquid water proofing compound ISI marked confirming to IS 2645 - 2003 complete all as specified and directed by Engineer-in-Charge. |
| 4 | Material and labour for repair of surface with GP-2 (General Purpose Grout) or repair mortar upto 15 mm thick as per site condition/ manufacturer’s instruction and including cracks shall be repaired with cement admixed with polymer as per manufacturer’s instructions complete all as specified and directed by Engineer-in-Charge. Make of material : Sika / Fosroc / Pidilite / Asian Paints / MBTCC (BASF) / I-CanNano or Techno commercial equivalent make approved by CWE in writing from make mentioned in |
| 5 | OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index not less than 106 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength >= 2 N/mm2 (ASTM D4541), elongation 350 to 400% as per ASTM D412 and crack bridging ability upto 2mm.(a) After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification.(b) Apply 1st coat of ShaliUrethane® BTD (white) @ 650 gm / m²(minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry. (c ) Apply 2nd & 3rd coat of ShaliUrethane® BTD (white) @ 650 gm / m² (minimum) or equivalent by brush/roller. Make : Fosroc/Sika/Choksey/Bostik/STP/ Asian Paints/Berger PaintsNote : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE.(iii) The manufacturer/authorised applicator shall give a warranty for the performance & durability for 10 years. |
| 6 | M & L for providing PCC 1:2:4 type B-1 (nominal mix) using 20 mm crushed stone aggregate for coving / gola along vertical parapets of size 100 mm X 100 mm with concrete including supply and mixing liquid WPC in mortar @ as per manufacturer instruction per bag of cement of 50 kg complete all as specified and directed by Engineer-in-Charge. |
| 7 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed by Engineer-in-Charge. |
| 8 | Material and labour for water proofing treatment to RCC sunken slab and adjoining vertical slab as described following any one method complete all as specified and directed by Engineer-in-Charge.Method 1:(A) Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, Smart Care Damp proof 2K, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5 Clean all working surface & made free from dirt, grease laitance etc. After inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 Cement : 1 Polymer : 4 Sand). Making Gola of size 75 mm X 75 mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 (1 Cement : 1 Polymer : 4 Sand). The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5 kg/sqm per coats, etc., complete as per manufactures specifications.(B) Bore Packing: All the borehole gaps between concrete surface and PVC pipe of various dia upto the neck level shall be filled with non-shrink free flow grout – Smart Care GP Grout having dual shrinkage compensation property. Before the bore packing, surface of the PVC pie and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent.(C) Apply 12-15 mm plaster on slab and vertical surface admixed with Smart Care Vitalia Neo @ 200ml per bag of cement before treatment.(D) 40 mm dia HDPE pipe to be provided as spout pipe in sunken portion.Method 2: (A) Supplying and applying two component cementitious & acrylic flexible water proofing & protective coating, two coats with 1 mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance, cm/km is 0.09 of Dr Fixit Pidifin 2k @ 1.5kg/sqm with a paint brush over existing slab surface and adjoining vertical surface. The Polyester reinforced coated net of 45 g/sqm, 2.5 mm X 2.5 mm is laying on the surface immediately on the first coat of two component modified polymer Dr Fixit pidifin 2k. After removal of all lose materials like dust etc. with wire brush coir brushes from surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based mortar/micro concrete, after that making the gola on surrounding wall’s junction and seal the vertical walls. In case of core cutting on the surface, the joint is seal with non-shrink grout.(B) The coating shall be terminated at 1600 mm in toilet/2100 mm in bathroom on vertical walls.(C) Apply 12-15 mm water proof plaster on slab and vertical surface admixed with Dr Fixit pidiproof LW+ @200ml per bag of cement before treatment.(D) 40 mm dia HDPE pipe to be provided as spout pipe in sunken portion.Make: Method 1 (Asian paint)/ Method 2 (Dr fixit) or Techno commercial equivalent in make mentioned in Appx ‘B’ approved by CWE Note :- (i) The treatment shall be carried out by authorised applicator (through specialized agency ) approved by CWE as per the manufacturer.(ii) PCC filling under sunken area will be measured & paid separately(iii) Treatment should be continue upto 450 mm height on vertical wall (all sides and floor) of sunken but only plan area of sunken will be measured for payment. |
| 9 | Material and labour for water proofing treatment to walls surfaces of toilets/baths/WC's (1600mm in toilet and 2100mm in bathroom on vertical wall surface) with following applications complete all as specified and directed by Engineer-in-Charge. by Engineer-in-Charge :-(a) Applying first coat of chemical pidifin 2K (Dr Fixit) on cleaned surfaces @ 0.86 Kg/Sqm (Minimum) and drying for 24 Hours(b) Applying second coat of chemical Pidifin 2K (Dr Fixit) @ 0.86 Kg/Sqm (minimum) over first coatMake : Dr fixit or Techno commercial equivalent |
| 10 | M&L 40 mm GI pipe medium grade, with all fittings and fixed to walls and ceilings and laid in floors made to shape as in spout pipe in sunken/ verandah/ Balcony complete all as specified and directed by Engineer-in-Charge. |
| 11 | Material & Labour for PCC (1:5:10) type E2 using 40mm graded AAC Block Sludge as filling of sunken floors complete all as specified and directed by Engineer-in-Charge. by Engineer-in-charge. |
| 12 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge. |
| 13 | M & L for RCC M25 (Design Mix) using 20 mm nominal size graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge. |
| 14 | M & L for RCC M25 (Design Mix) using 12.50 mm nominal size graded crushed stone aggregate as in chajjas complete all as specified and directed by Engineer-in-Charge. |
| 15 | M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. |
| 16 | M & L for TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. |
| 17 | M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and directed by Engineer-in-Charge. |
| 18 | M & L for formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of concretecomplete all as specified and directed by Engineer-in-Charge. |
| 19 | Taking down cement plaster on bricks or stone walls etc and including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge. |
| 20 | M & L for cement mortar (general purpose, factory made, for indoor use having bulk density (of dry mix) 1600 kg per cubic metre, wet density (after mixing) 1800 kg per cubic metre, dry density (after setting) 1800 kg per cubic metre, pot life 60 minutes, compressive strength ≥ 6 Mpa, capillary water absorption ≤ 0.40 kg/ sqm min 0.5, adhesion 0.5 N/sqmm fracture pattern: B, Water-vapour permeability coefficient μ 15/35 as per BS EN 998-01 : 2016, made using well graded manufactured sand filler, Portland cement & polymer binder, and chemical additives) for internal plaster 15 mm thick on brick wall, AAC block wall, PCC solid block wall or concrete surfaces including making groove of appropriate size and finishing even and smooth complete all as specified and directed by Engineer-in-Charge. |
| 21 | M & L for cement mortar (general purpose, factory made, for outdoor use having bulk density (of dry mix) 1600 kg per cubic metre, wet density (after mixing) 1800 kg per cubic metre, dry density (after setting) 1800 kg per cubic metre, pot life 60 minutes, compressive strength ≥ 6 Mpa, capillary water absorption ≤ 0.40 kg/ sqm min 0.5, adhesion 0.5 N/sqmm fracture pattern: B, Water-vapour permeability coefficient μ 15/35 as per BS EN 998-01 : 2016, made using well graded manufactured sand filler, Portland cement & polymer binder, and chemical additives) for external plaster 15 mm thick on brick wall, AAC block wall, PCC solid block wall or concrete surfaces including making groove of appropriate size and finishing even and fair complete all as specified and directed by Engineer-in-Charge. |
| 22 | M & L for cement mortar (general purpose, factory made, for indoor use having bulk density (of dry mix) 1600 kg per cubic metre, wet density (after mixing) 1800 kg per cubic metre, dry density (after setting) 1800 kg per cubic metre, pot life 60 minutes, compressive strength ≥ 6 Mpa, capillary water absorption ≤ 0.40 kg/ sqm min 0.5, adhesion 0.5 N/sqmm fracture pattern: B, Water-vapour permeability coefficient μ 15/35 as per BS EN 998-01 : 2016, made using well graded manufactured sand filler, Portland cement & polymer binder, and chemical additives) for internal plaster 5 mm thick on ceiling and finishing even and smooth complete all as specified and directed by Engineer-in-Charge. |
| 23 | M & L for applying white cement based polymeric putty conforming to IS 17545: 2021, average thickness 2 mm on new, old plastered surfaces, mixed with water in mechanical mixer, applying in one or more coats not exceeding the recommended thickness and keeping the gap/ the interval in subsequent coats, applying on the moistened wall surface uniformly in an upward direction with the help of a putty blade complete as per the manufacturer’s instructions and complete all as specified and directed by Engineer-in-Charge. |
| 24 | M & L for complete removal of existing finish on walls including chajjas, facias etc and preparing and applying white cement based polymeric putty conforming to IS 17545: 2021, average thickness 2 mm on old plastered surfaces completely removed from the existing treatment, mixed with water in mechanical mixer, applying in one or more coats not exceeding the recommended thickness and keeping the gap/ the interval in subsequent coats, applying on the moistened wall surface uniformly in an upward direction with the help of a putty blade complete as per the manufacturer’s instructions and complete all as specified and directed by Engineer-in-Charge. |
| 25 | M & L for preparing plaster surfaces of walls treated with any type of putty and applying acrylic distemper in two or more coats, VOC less than 50 gms/ litre as per IS 101 (Part 2/Sec 2), matt finish, medium washability, of approved shade, over a coat of primer as per the manufacturer’s instructions, applying using roller, keeping the gap/ the interval in subsequent coats, including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and directed by Engineer-in-Charge. |
| 26 | M & L for preparing plastered surfaces of wall treated with any type of putty including chajjas, facias etc. and applying premium acrylic smooth exterior paint (100% acrylic) with silicone additives in two or more coats, that offers an anti-algal, excellent resistance to ultraviolet radiation, dirt pick up resistance (DPUR) property, rich sheen, low VOC, of approved shade over a coat of primer as per the manufacturer’s instructions, applying using roller, keeping the gap/ the interval in subsequent coats, including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and directed by Engineer-in-Charge. |
| 27 | M&L for preparing plastered surfaces of Ceiling treated with any type of putty and smoothening the surfaces with sand paper/mechanised sanding etc (preparatary paint as directed), and applying two coat of 100% premium intetrior acrylic emulsion paint by using brush roller complete all as specified & directed by Engr-in-charge. |
| 28 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified & directed by Engr-in-charge. |
| 29 | M & L for double charge vitrified coloured tiles (approved shade), area of each tile exceeding 0.36 Sqm but not exceeding 1.44 Sqm, having thickness more than 8mm, premium quality having water absorption less than 0.08%, straight edge, stain free, glossy finish, square marbonite, laid as in floors/skirting etc., set and jointed including using type-2 adhesive (Medium Thick Bed Fixing) confirming to IS-15477:2019, fixed the tile using spacer 5mm or as per manufacturer’s instruction and joint filled with epoxy grout matching with the colour of tiles including necessary cutting as per site requirement, complete all as specified and directed by Engineer-in-Charge. |
| 30 | All as per Item no 29 here in before, on vertical surfaces such as skirtings ,set & jointed in neat and pointed in epoxy grout to match the floor tiles, over & including 10 mm thick screed in cement mortar (1:4) complete all as specified & directed by Engr-in-charge. |
| 31 | M & L for ceramic floor tiles as per IS 15622: 2017 and IS 13712: 2019, Group B II, anti-skid, glazed, unpolished, rectified, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, minimum 8 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and directed by Engineer-in-Charge. |
| 32 | M & L for ceramic wall tiles as per IS 15622: 2017 and IS 13712: 2019, Group B II, glazed, unpolished, rectified,300x600mm, minimum 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and directed by Engineer-in-Charge. |
| 33 | M & L for ceramic wall tiles as per IS 15622: 2017 and IS 13712: 2019, Group B II, glazed, unpolished, rectified, impressive digitally printed themes with unique highlighters in 3-D texture, 300x600mm minimum 8 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and directed by Engineer-in-Charge. |
| 34 | Dismantling stone slabs and tiles of any description or thickness, laid, bedded and pointed in any mortar as in floors, aprons etc complete all as specified and directed by Engineer-in-Charge. |
| 35 | M & L for 20 mm thick telephonic black granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and including 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge. |
| 36 | M&L for machine cut pre polished Green marble flooring 18-20 mm thick over cement screed base laid over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge. |
| 37 | M&L for machine cut pre polished Green marble 18-20 mm thick as in skirting and pillar laid over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as specified and directed by Engineer-in-Charge. |
| 38 | M&L for machine cut pre polished kota stone slab flooring 20-25 mm thick over cement screed base laid over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-Charge. |
| 39 | M & L for mirror polishing on marble/ granite/ Kota stone/ stone works wherever required using polishing with carborundum stone and buffing top with aluminium or tin oxide abrasive powder to give high gloss finish complete all as specified and directed by Engineer-in-Charge. |
| 40 | M & L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engineer-in-Charge. |
| 41 | M & L for ceramic anti-skid full body vitrified step tiles 10mm thick as per IS 15622: 2017 and IS 13712: 2019, group B Ia, glazed, polished, rectified, single piece length wise upto 1200 mm, bullnose, self-embossed, grooved, etc., minimum 8 mm thick in treads, landings, risers, etc. including 15 mm thick screed bed or bedding layer in cement mortar (1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and directed by Engineer-in-Charge. |
| 42 | Dismantling wall and ceilling boarding, (fiber, pulp, insulation, etc.) or insulation board /slab /blankets, any thickness, in snap grid complete all as specified and directed by Engineer-in-Charge. |
| 43 | Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm centre to centre to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications and as directed by Engineer-in-charge. |
| 44 | M & L for 4 mm thick plain fibre cement flat sheets type B, any category as per IS 14862: 2000 (non-asbestos) building boards, cured in HPSC (high pressure steam curing ) process, highly chemical stabilised, design and texture as approved, fixed to timber/GI /Aluminium framework with screw in ceilings flat or sloping complete all as specified and directed by Engineer-in-Charge. |
| 45 | Taking down chowkhats or frames n.exc 1.5 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer-in-Charge. |
| 46 | Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer-in-Charge. |
| 47 | Taking down wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and directed by Engineer-in-Charge. |
| 48 | M & L factory made uPVC white colour casement (Openable) Glazed window made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners, Area not exceeding 1.00 sqm each including supply and fixing following hardware items :-(a) casement handle made of zinc alloyed (white powder coated)(b) Stainless steel But Hinges - 03 Nos Each shutter (c) transmission gear made of mild steel with multi point locking system. (d) 5mm thick toughenend glass complete all as specified & directed by Engineer-in-Charge.Note: - (1) The cost of glass and all other connected accessories shall deemed to be included in the quoted unit rate (ii) Cutting holes of suitable depth in wall for inserting lugs etc including making good dismantled portion with PCC (1:2:4) type B-0 using 12 5mm graded crushed stone aggregate and cement mortar (1:3) shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. (iv) uPVC frame, sash and mullion extruded profiles (+- 5%) tolerance in dimension i.e. in depth & width of profile shall be acceptable. |
| 49 | M & L factory made uPVC white colour casement (Openable) Guaged window made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners Area not exceeding 1.00 sqm each including supply and fixing following hardware items :-(a) casement handle made of zinc alloyed (white powder coated)(b) Stainless steel But Hinges - 03 Nos Each shutter (c) transmission gear made of mild steel with multi point locking system. (d) 0.36mm nominal dia of stainless steel guaging with selected quality mesh complete all as specified & directed by Engineer-in-Charge.Note: - (1) The cost of and all other connected accessories shall deemed to be included in the quoted unit rate (ii) Cutting holes of suitable depth in wall for inserting lugs etc including making good dismantled portion with PCC (1:2:4) type B-0 using 12 5mm graded crushed stone aggregate and cement mortar (1:3) shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. (iv) uPVC frame, sash and mullion extruded profiles (+- 5%) tolerance in dimension i.e. in depth & width of profile shall be acceptable. |
| 50 | S & F factory made uPVC white colour fixed glazed ventilator made of frame 47 mm X 50 mm mullion 47 mm X 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 mm X 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, including Glass- 5 mm thick toughend glass pin head type complete all as specified and directed by Engineer-in-Charge.Note: (i) The cost of glass, wire mesh, fasteners and all other connected accessories shall deemed to be included in the quoted unit rate. (ii) Cost for making good to cutting holes/dismantled portion during taking down old, with PCC (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregate or cement mortar (1:3) shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. (iv) uPVC frame, sash and mullion extruded profiles ± 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Please Enable Macros to View BoQ information |
| 51 | S & F factory made uPVC white colour fixed glazed ventilator made of frame 47 mm X 50 mm mullion 47 mm X 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 mm X 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, including Glass- 5 mm thick toughend glass pin head type complete all as specified and directed by Engineer-in-Charge.Note: (i) The cost of glass, wire mesh, fasteners and all other connected accessories shall deemed to be included in the quoted unit rate. (ii) Cost for making good to cutting holes/dismantled portion during taking down old, with PCC (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregate or cement mortar (1:3) shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. (iv) uPVC frame, sash and mullion extruded profiles ± 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysOct 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents