Tender For Boys High School Hib Dangerpora Bwo Art Craft Room,Computer Room And Library Room.
Tender Value
60.84 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
4 days left
EMD
1.21 Lakhs
Bank guarantee accepted
Document Fee
1600
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baramulla → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Boys High School Hib Dangerpora Bwo Art Craft Room,Computer Room And Library Room.
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres All kinds of soil : |
| 2 | Providing & Laying of stone soling (dully hand packed)including watering dressing and ramming with all carriages loading un-loading and stacking etc complete |
| 3 | Providing & Laying of Nallah Muck/ RBm filling including watering dressing and ramming with all carriages loading un-loading and stacking etc complete |
| 4 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | CEMENT CONCRETE (CAST-IN-SITU)Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for:Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 11 | Brick work with FPS bricks of class designation 75 in super structure in cement mortar 1:6 (1 cement, 6 coarse sand) incl all carriages and headload |
| 12 | Providing wood work in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position Imported wood (KD) |
| 13 | Providing & fixing panelled or panelled & glazed shutters for doors & windows and clerestory windows including ISImarked black enamelled M.S Butt hingeswith necessary screws excluding panelling (approved imported wood KD) 35mm thick |
| 14 | Providing & fixing decorative plywood B/S decorative veneer (Type 1) confirming to IS 1328 BWR type |
| 15 | Providing & fixing of 40x5mm flat iron hold fast 40cm long including fixing to frameswith 10mm dia bolts nuts &wooden plugs and embedding in cement conc block 30x10x5cm 1:3:6mix 1cement:3coarse sand:6 graded st agg)20mm nominal size |
| 16 | 12mm Cement Plaster on the rough side of single or half brick wall of mix 1:6(1 cement:6 fine sand) |
| 17 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 18 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 19 | Providing glass panes 3.5 mm thick ) clerestory window shutters (Area of opening for glass panes excld portion inside shall be measured) |
| 20 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2 mm thick |
| 21 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 22 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 23 | Painting with silicon and acrylic emulsion based water thinnable sealer ofapproved brand and manufacture on wet or patchy portion of plasteredsurfaces: Two coats |
| 24 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. New work (two or more coats) over and including priming coat with cement primer |
| 25 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 26 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 27 | Providing High Rib colour coated GI sheet roofing fixed with polymer coated J or L hooks bolts & nuts 8mm dia with bitumen & GI limpet washers upto( a pitch of 60 degree) excld cost of perlins, rafters & tresses 0.50mm thick with zinc coating not less than 275g/sqm (JSW color Dura shine |
| 28 | Providing ridges of hips of width 60cm overall width plain GS sheets fixed with polymer coated J or L hooks bolts & nuts 8mm dia GI limpet & bitumen washers complete 0.50mm thick with zinc coating not less than 275g/sqm |
| 29 | Providing hardware items of standard quality as directed by site engineer.Concealed Lock |
| 30 | Towerbolts 100 mm |
| 31 | 150mm |
| 32 | Handles 150 mm |
| 33 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 34 | Lighting point (one lighting point includes wiring of lighting point in 1.5 sq.mm PVC insulated copper wire and 2.5 sq.mm PVC insulated multistrand copper wire,6 amp one way swittch6 amp S pole MCB,10 amp DP MCB,2 way DB MCB and hylem sheet with 16/15 Watt LED surface lights.including cost of channelsas per requirement.One point controlled by one 6 amp switch.( upto 10 meters)including Placing and fixing in position 25mm PVC Conduit pipes with necessary bends and other fittings in RCC Work directed by engineer incharge. |
| 35 | Heating point (one heatting point includes wiring of lighting point in 2.5 sq.mm PVC insulated copper wire and 4.00 sq.mm PVC insulated multistrand copper wire,16 amp one way swittch,10 amp S pole MCB,2 way DB MCB and hylem sheet.including Placing and fixing in position deep junction of cast iron with network Conduit pipes with necessary fittings in RCC Work. |
| 36 | Providing and fixing of wiring for Service Line in 10 sqmm pvc insulated multi strand copper wire flame retardant of approved company(havells, polycab, anchor etc)Iso certified incl. all charges complete. |
| 37 | Providing and fixing one fan point includes wiring for lighting points in 1.5sqmm pvc insulated copper wire and 2.5sqmm pvc in multi -strant copper wire 1200mm ceilling fan electronic fan dimmer.6Amp s pole MCB-10AMP DP MCB 2 Way DB for housing MCB or lightting circuits and hylem sheet.including Placing and fixing in position Fan clamp boxes with MS Fan clamps connected with network Conduit pipes with necessary fittings in RCC Work Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender