Health and Family Welfare Boards / Undertakings / PSU Closing in 18 days TDR #57529821

Bids Are invited for Thromoboelastograph Coagulation Analyzer With Accessories - The Machine Should Measure Viscoelastic Properties Of Blood S Le , Must Be Fully Automatic And Does Not Require Any Additional Computer/Module/Software To Run A Test. ,

Issued by Boards / Undertakings / PSU · Muzaffarpur, Bihar
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Oct 2026
18 days left
EMD
69300
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Muzaffarpur → Bihar
EMD Exemption
Available
Quantity
1

Project Description

Bids Are invited for Thromoboelastograph Coagulation Analyzer With Accessories - The Machine Should Measure Viscoelastic Properties Of Blood S Le , Must Be Fully Automatic And Does Not Require Any Additional Computer/Module/Software To Run A Test. , It Should Perform Comprehensive Hemostasis Analysis Including Platelet Mapping Rapidly And Accurately Of Blood S Le On Point Of Care Or In Laboratory , Based On Automatically Loaded Microfluidic Cartridge/Cassette System For Monitoring Global Hemostasis And Platelet Mapping , Must Provide All Parameters From Clot Formation To Clot Lysis Numerically And Graphically , Portable, Small Footprint, Compact, Vibration Resistant And User Friendly , Should Be Able To Perform In Native Or Citrated Or Heparinised Blood S Le , Test Preparation Should Not Require Complex Pipetting And Mixing , Must Have An Inbuilt Touch Screen To View The Graph And Numeric Results. , Should Include A Thermal Printer With Adequate Printer Paper Roll For Printing Of Reports From Equipment Directly. , Should Have A Self-Monitoring Quality Control System And Provide Test Kits For Quality , Reagents Should Have Stability And Longer Self-Life. , Any Other Essential Hardware/Software/Items Required To Make All The Above Things Functional Should Be Provided. , Please Specify Power Consumption , All Necessary Standards And Norms (As Applicable) , The Individual Reagent As Per Annexure A Should Be Supplied With The Equipment For 20 Tests Each. , General Terms: , Training: , Local Service Support: Should Have Local Office And Service Support/Service Engineer For Attending The Breakdown Calls. Details To Be Submitted. , Response Time: Should Not Be More Than 06 Hrs From Lodging A Breakdown Complaint On Toll Free Or By Email. , Warranty- 2 Years , Cmc- Cost Per Annum Will Be Considered For All Bidders For 8 Years After Warranty , Warranty And Cmc Should Include A) Two Preventive Maintenance And Unlimited Breakdown Calls Along With Spares.B) All Bought Out Items Quoted Along With The Main System (Local/Non-Local) And Ups Should Be Covered. C) Yearly Calibration/Validation/Qa, Testing And Measuring Equipment Used Should Be Traceable To Si Units Through National/ International Standards (As Per Nabl/Nabh Norms). D) Pm Kit If Any. E) All Upgrades/Update, No Seperate Licence Fees Will Be Payable. , Back To Back Assurance To Be Taken By The Supplier From Oem To Supply Spares For Minimum 10 Years And To Be Submitted. , Penalty Clause:

BOQ

Sl. No. Item TitleItem Description
1The machine should measure viscoelastic properties of blood sampleThe machine should measure viscoelastic properties of blood sample
2Must be fully automatic and does not require any additional computer/module/software to run a test.Must be fully automatic and does not require any additional computer/module/software to run a test.
3It should perform comprehensive hemostasis analysis including platelet mapping rapidly and accurately of blood sample on point of care or in laboratoryIt should perform comprehensive hemostasis analysis including platelet mapping rapidly and accurately of blood sample on point of care or in laboratory
4Based on automatically loaded microfluidic cartridge/cassette system for monitoring global hemostasis and platelet mappingBased on automatically loaded microfluidic cartridge/cassette system for monitoring global hemostasis and platelet mapping
5Must provide all parameters from clot formation to clot lysis numerically and graphicallyMust provide all parameters from clot formation to clot lysis numerically and graphically
6Portable, Small footprint, compact, vibration resistant and user friendlyPortable, Small footprint, compact, vibration resistant and user friendly
7Should be able to perform in native or citrated or heparinised blood sampleShould be able to perform in native or citrated or heparinised blood sample
8Test preparation should not require complex pipetting and mixingTest preparation should not require complex pipetting and mixing
9Must have an inbuilt touch screen to view the graph and numeric results.Must have an inbuilt touch screen to view the graph and numeric results.
10Should include a Thermal Printer with adequate printer paper roll for printing of reports from equipment directly.Should include a Thermal Printer with adequate printer paper roll for printing of reports from equipment directly.
11Should have a self-monitoring quality control system and provide test kits for qualityShould have a self-monitoring quality control system and provide test kits for quality
12Reagents should have stability and longer self-life.Reagents should have stability and longer self-life.
13Any other essential hardware/software/items required to make all the above things functional should be provided.Any other essential hardware/software/items required to make all the above things functional should be provided.
14Please specify power consumptionPlease specify power consumption
15All necessary standards and norms (As applicable)All necessary standards and norms (As applicable)
16The individual reagent as per Annexure A should be supplied with the equipment for 20 tests each.The individual reagent as per Annexure A should be supplied with the equipment for 20 tests each.
17General terms:General terms:
18Training:Training:
19Local Service Support: Should have local office and service support/service engineer for attending the breakdown calls. Details to be submitted.Local Service Support: Should have local office and service support/service engineer for attending the breakdown calls. Details to be submitted.
20Response Time: Should not be more than 06 hrs from lodging a breakdown complaint on toll free or by email.Response Time: Should not be more than 06 hrs from lodging a breakdown complaint on toll free or by email.
21Warranty- 2 yearsWarranty- 2 years
22CMC- cost per annum will be considered for all bidders for 8 years after warrantyCMC- cost per annum will be considered for all bidders for 8 years after warranty
23Warranty and CMC Should include a) two preventive maintenance and unlimited breakdown calls along with spares.b) All bought out items quoted along with the main system (local/non-local) and UPS should be covered. c) Yearly calibration/Validation/QA, Testing and measuring equipment used should be traceable to SI units through National/ International standards (as per NABL/NABH norms). d) PM kit if any. e) All upgrades/update, no seperate licence fees will be payable.Warranty and CMC Should include a) two preventive maintenance and unlimited breakdown calls along with spares.b) All bought out items quoted along with the main system (local/non-local) and UPS should be covered. c) Yearly calibration/Validation/QA, Testing and measuring equipment used should be traceable to SI units through National/ International standards (as per NABL/NABH norms). d) PM kit if any. e) All upgrades/update, no seperate licence fees will be payable.
24Back to back assurance to be taken by the supplier from OEM to supply spares for minimum 10 years and to be submitted.Back to back assurance to be taken by the supplier from OEM to supply spares for minimum 10 years and to be submitted.
25Penalty Clause:Penalty Clause:

AI Tender Summary

OUR REF NO 57529821
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 06-10-2026
Authority
Authority Name Tata Memorial Centre
Work Description Bids Are invited for Thromoboelastograph Coagulation Analyzer With Accessories - The Machine Should Measure Viscoelastic Properties Of Blood S Le , Must Be Fully Automatic And Does Not Require Any Additional Computer/Module/Software To Run A Test. , It Should Perform Comprehensive Hemostasis Analysis Including Platelet Mapping Rapidly And Accurately Of Blood S Le On Point Of Care Or In Laboratory , Based On Automatically Loaded Microfluidic Cartridge/Cassette System For Monitoring Global Hemostasis And Platelet Mapping , Must Provide All Parameters From Clot Formation To Clot Lysis Numerically And Graphically , Portable, Small Footprint, Compact, Vibration Resistant And User Friendly , Should Be Able To Perform In Native Or Citrated Or Heparinised Blood S Le , Test Preparation Should Not Require Complex Pipetting And Mixing , Must Have An Inbuilt Touch Screen To View The Graph And Numeric Results. , Should Include A Thermal Printer With Adequate Printer Paper Roll For Printing Of Reports From Equipment Directly. , Should Have A Self-Monitoring Quality Control System And Provide Test Kits For Quality , Reagents Should Have Stability And Longer Self-Life. , Any Other Essential Hardware/Software/Items Required To Make All The Above Things Functional Should Be Provided. , Please Specify Power Consumption , All Necessary Standards And Norms (As Applicable) , The Individual Reagent As Per Annexure A Should Be Supplied With The Equipment For 20 Tests Each. , General Terms: , Training: , Local Service Support: Should Have Local Office And Service Support/Service Engineer For Attending The Breakdown Calls. Details To Be Submitted. , Response Time: Should Not Be More Than 06 Hrs From Lodging A Breakdown Complaint On Toll Free Or By Email. , Warranty- 2 Years , Cmc- Cost Per Annum Will Be Considered For All Bidders For 8 Years After Warranty , Warranty And Cmc Should Include A) Two Preventive Maintenance And Unlimited Breakdown Calls Along With Spares.B) All Bought Out Items Quoted Along With The Main System (Local/Non-Local) And Ups Should Be Covered. C) Yearly Calibration/Validation/Qa, Testing And Measuring Equipment Used Should Be Traceable To Si Units Through National/ International Standards (As Per Nabl/Nabh Norms). D) Pm Kit If Any. E) All Upgrades/Update, No Seperate Licence Fees Will Be Payable. , Back To Back Assurance To Be Taken By The Supplier From Oem To Supply Spares For Minimum 10 Years And To Be Submitted. , Penalty Clause:
Basic Detail
Tender No GEM/2026/B/8025931
Bidding Type Tender
Location
City Muzaffarpur
State Bihar
Key Dates
Publish Date 15 Sep 2026
Submission Date 06 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 69300
Exemption Available
Document List
7df60997-671d-4fb9-b37e-6e2f827ddd14.pdf
1789389912.xlsx
thromboelastograph_2026-09-11-11-42-51_ca6d327e24bd23100f4549a518226e44.xlsx

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
pdf

7df60997-671d-4fb9-b37e-6e2f827ddd14.pdf

xlsx

1789389912.xlsx

xlsx

thromboelastograph_2026-09-11-11-42-51_ca6d327e24bd23100f4549a518226e44.xlsx

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders