Communications and Information Technology Government Departments Closing in 9 days TDR #57529570

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Electrical System Or Installation; Service Provider - Making Temperory Power Supply Arrangement By Providing Of Bypass Arrangement I/

Issued by Government Departments · Bengaluru Urban, Karnataka
Tender Value
72943
Estimated cost
Bid Submission
28 Sep 2026
9 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Not Available
Quantity
1

Project Description

Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Electrical System Or Installation; Service Provider - Making Temperory Power Supply Arrangement By Providing Of Bypass Arrangement I/C S/F 2Nos Of Suitable Pvc Insulated Aluminium Conductor Cable About 0.5 Mtrs Each For Bupassing The 2Nos Cts Cleaning Insulating For Ht Insulation Arranging Of Shutdown Hescom Authorities Inspection Etc., Complete As Required , Supplying And Fixing Of Ht Current Transformer Of Ratios 2.5A/5A Ratio As Per Site Requirement With Burden Of 2.5 Va, Accuracy Class 0.2S And Suitable For 11Kv Ht Supply In The Existing Ht Metering Cubicle Panel I/C Reconnections With Existing Wires / Bus With Necessary Replacement / Suitable Modifications As Per Requirement, The Work Also Involves Arranging For Hescom Power Supply Shut Down & Mrt Aee For Testing & Commissioning Etc., As Required , Cleaning Of Ht Metering Cubicle Yard Vegetation Including Respreading The Metal Jelly, Cutting Bushes, Spreying Chemical, Cleaning Of Dust Etc., As Required. , Alteration Of Metering Cubicle Door Including Removing The Door Cover, Taking To Workshop, Bending, Back To Site, Fixing With Welding Etc., As Required. , Fault Rectification Of 7.5Kva Online Ups Including Cleaning, Tightning The Control Cards, Cleaning The Inverter Card With Blower, Tightning Of The Battery Leads, Cleaning The Battery Connector Terminals, Pouring The Distiled Water (10 Litres) To Battery Set, Applying Petrolium Jelly To Battery Terminals Etc., As Required. , S/F Of 3 Phase Ht Dolo Set Including Dolo Mounting Ms Structure, Alteration For Fixing Of Dolo Mounting Kit On Dp Structure And S/F Of 3 Nos 11Kv Pin Insulators, 3X2mtrs Acsr Conductor, Rectifiction Of Gos Operating Mechanism I/C Offering Shut Down From Eb Authorities Etc., As Required. , Repairs To Ups Wiring System For 4 Floors, Individual Circuit Checking Of Each Floors, Attending The Faults, Fault Rectification In Mcb Change Over And Mcb Dbs Wiring, Etc., As Required.

BOQ

Sl. No. Item TitleItem Description
1Making Temperory power supply arrangement by providing of BYPASS arrangement i/c S/F 2Nos of suitable PVC insulated aluminium conductor cable about 0.5 Mtrs each for bupassing the 2Nos CTs cleaning insulating for HT insulation arranging of Shutdown HESCOM authorities inspection etc., complete as requiredMaking Temperory power supply arrangement by providing of BYPASS arrangement i/c S/F 2Nos of suitable PVC insulated aluminium conductor cable about 0.5 Mtrs each for bupassing the 2Nos CTs cleaning insulating for HT insulation arranging of Shutdown HESCOM authorities inspection etc., complete as required
2Supplying and Fixing of HT current transformer of ratios 2.5A/5A ratio as per site requirement with Burden of 2.5 VA, Accuracy class 0.2S and suitable for 11KV HT supply in the existing HT metering cubicle panel i/c reconnections with existing wires / bus with necessary replacement / suitable modifications as per requirement, The work also involves \\" Arranging for HESCOM power supply shut down & MRT AEE for testing & commissioning etc., as requiredSupplying and Fixing of HT current transformer of ratios 2.5A/5A ratio as per site requirement with Burden of 2.5 VA, Accuracy class 0.2S and suitable for 11KV HT supply in the existing HT metering cubicle panel i/c reconnections with existing wires / bus with necessary replacement / suitable modifications as per requirement, The work also involves \\" Arranging for HESCOM power supply shut down & MRT AEE for testing & commissioning etc., as required
3Cleaning of HT metering cubicle yard vegetation including respreading the metal jelly, cutting bushes, spreying chemical, cleaning of dust etc., as required.Cleaning of HT metering cubicle yard vegetation including respreading the metal jelly, cutting bushes, spreying chemical, cleaning of dust etc., as required.
4Alteration of metering cubicle door including removing the door cover, taking to workshop, bending, back to site, fixing with welding etc., as required.Alteration of metering cubicle door including removing the door cover, taking to workshop, bending, back to site, fixing with welding etc., as required.
5Fault rectification of 7.5KVA online UPS including cleaning, tightning the control cards, cleaning the inverter card with blower, tightning of the battery leads, cleaning the battery connector terminals, pouring the distiled water (10 litres) to battery set, applying petrolium jelly to battery terminals etc., as required.Fault rectification of 7.5KVA online UPS including cleaning, tightning the control cards, cleaning the inverter card with blower, tightning of the battery leads, cleaning the battery connector terminals, pouring the distiled water (10 litres) to battery set, applying petrolium jelly to battery terminals etc., as required.
6S/F of 3 phase HT DOLO set including DOLO mounting MS structure, alteration for fixing of DOLO mounting kit on DP Structure and S/F of 3 Nos 11KV pin insulators, 3X2Mtrs ACSR conductor, rectifiction of GOS operating mechanism i/c offering shut down from EB authorities etc., as required.S/F of 3 phase HT DOLO set including DOLO mounting MS structure, alteration for fixing of DOLO mounting kit on DP Structure and S/F of 3 Nos 11KV pin insulators, 3X2Mtrs ACSR conductor, rectifiction of GOS operating mechanism i/c offering shut down from EB authorities etc., as required.
7Repairs to UPS wiring system for 4 floors, individual circuit checking of each floors, attending the faults, fault rectification in MCB change over and MCB DBs wiring, etc., as required.Repairs to UPS wiring system for 4 floors, individual circuit checking of each floors, attending the faults, fault rectification in MCB change over and MCB DBs wiring, etc., as required.

AI Tender Summary

OUR REF NO 57529570
AUTHORITY Government Departments
TENDER VALUE 72943
LAST DATE 28-09-2026
Authority
Authority Name Department Of Telecommunications
Work Description Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Electrical System Or Installation; Service Provider - Making Temperory Power Supply Arrangement By Providing Of Bypass Arrangement I/C S/F 2Nos Of Suitable Pvc Insulated Aluminium Conductor Cable About 0.5 Mtrs Each For Bupassing The 2Nos Cts Cleaning Insulating For Ht Insulation Arranging Of Shutdown Hescom Authorities Inspection Etc., Complete As Required , Supplying And Fixing Of Ht Current Transformer Of Ratios 2.5A/5A Ratio As Per Site Requirement With Burden Of 2.5 Va, Accuracy Class 0.2S And Suitable For 11Kv Ht Supply In The Existing Ht Metering Cubicle Panel I/C Reconnections With Existing Wires / Bus With Necessary Replacement / Suitable Modifications As Per Requirement, The Work Also Involves Arranging For Hescom Power Supply Shut Down & Mrt Aee For Testing & Commissioning Etc., As Required , Cleaning Of Ht Metering Cubicle Yard Vegetation Including Respreading The Metal Jelly, Cutting Bushes, Spreying Chemical, Cleaning Of Dust Etc., As Required. , Alteration Of Metering Cubicle Door Including Removing The Door Cover, Taking To Workshop, Bending, Back To Site, Fixing With Welding Etc., As Required. , Fault Rectification Of 7.5Kva Online Ups Including Cleaning, Tightning The Control Cards, Cleaning The Inverter Card With Blower, Tightning Of The Battery Leads, Cleaning The Battery Connector Terminals, Pouring The Distiled Water (10 Litres) To Battery Set, Applying Petrolium Jelly To Battery Terminals Etc., As Required. , S/F Of 3 Phase Ht Dolo Set Including Dolo Mounting Ms Structure, Alteration For Fixing Of Dolo Mounting Kit On Dp Structure And S/F Of 3 Nos 11Kv Pin Insulators, 3X2mtrs Acsr Conductor, Rectifiction Of Gos Operating Mechanism I/C Offering Shut Down From Eb Authorities Etc., As Required. , Repairs To Ups Wiring System For 4 Floors, Individual Circuit Checking Of Each Floors, Attending The Faults, Fault Rectification In Mcb Change Over And Mcb Dbs Wiring, Etc., As Required.
Basic Detail
Tender No GEM/2026/B/8039763
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 15 Sep 2026
Submission Date 28 Sep 2026
Open Date 29 Sep 2026
Finance
Tender Value 72943
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
67a2c259-31c1-467b-a146-373403f49f06.pdf
1789471104.xlsx
1789471157.pdf
1789471162.pdf
1789471167.pdf
ATC39_795cd5e8-89d4-4c7d-803f1789471682526_EEEHUBLI.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

67a2c259-31c1-467b-a146-373403f49f06.pdf

xlsx

1789471104.xlsx

pdf

1789471157.pdf

pdf

1789471162.pdf

pdf

1789471167.pdf

pdf

ATC39_795cd5e8-89d4-4c7d-803f1789471682526_EEEHUBLI.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders