Housing Urban and Rular Development Government Departments Closing in 5 days TDR #57528740

Tender For repair maintenance Electrical & Mech. Services At Nes Electrical Division M-251, Delhi. (Sh:- Miscellaneous E & M Works At Various Pwd Sites)

Issued by Government Departments · Delhi, Delhi
Tender Value
9.42 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
5 days left
EMD
18845
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for repair maintenance Electrical & Mech. Services At Nes Electrical Division M-251, Delhi. (Sh:- Miscellaneous E & M Works At Various Pwd Sites)

BOQ

Name of Work:- RMO Elect. & Mech. Services at NES Electrical Division M-251, Delhi. (SH:- Miscellaneous E & M works at various PWD sites)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group C
2Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
33 x 1.5 sq. mm
43 x 4 sq. mm
56 x 4 sq. mm
63 x 6 sq. mm
7Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a). 25 mm
8Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
9Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
10Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
118 Module (125mmX125mm)
12Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
135/6 amps switch
1415/16 A switch
153 pin 15/16 A socket outlet
16Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
176 way (4 + 18), Double door
18Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
19Single pole
20Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
21100 A
22LED Batten light (System lumen efficacy ≥105 <120lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm)
2340 watt
24LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)
2536 Watt
26Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Outdoor unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drainpipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filtration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391as required.
272.0 TR with 5 Star BEE Rating
28Supplying and Fixing 400 mm PVC Wall Fan suitable for operation on 230 volt, ±10%, 50 Hz supply to fixed by making necessary arrangements on the wall i/c testing etc. as reqd.
29S.I.T. C. of 15 Ltr. Capacity vertical storage type water heater (Geyser) 2 KW (5 Star Rated) heating elements, S.S. Tank having auto cut off thermostat, thermal cut off, pressure release valve etc. complete i/c installation on wall with hauz pipe connection, suitable fixing arrangement, 3 core cable/ cord with 15/16 Amps. 3 pin plug upto nearest power outlet etc. as reqd.
30Supplying of one Number Following size. XLPE insulated PVC outer sheathed armoured with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098/(Pt.-I)/88 with ammendment No. 1 in following manners. 3.5 x 70 sq. mm (In open duct)
31Supplying of one Number Following size. XLPE insulated PVC outer sheathed armoured with standard aluminium conductor suitable for rated voltage of 1.1 KV grade ISI marked confirming to IS 7098/(Pt.-I)/88 with ammendment No. 1 in following manners. 3.5 x 70 sq. mm (In pipe)
32Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 70 sq. mm (38mm)
33Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
34Supplying and Fixing heavy duty 300 mm dia Metal Exhaust Fan confirming to IS 2312/67 having 900 RPM suitable for operation on 230 volt + 10%, 50 Hz supply to fixed by making opening/existing opening on wall i/c connection with 1.5 Sq. mm PVC single core cable i/c testing etc. as required.
35Supplying, Installation, Testing and Commissioning of stainless steel storage type water Cooler 150/150 Ltr. capacity, fully stainless steel suitable for operation on 230 V+10% 50 Hz single phase AC supply i/c making water line and electrical connection etc. as required.
36Supplying, Installation, Testing and Commissioning of Reverse Osmosis (R.O. System) water Purification unit as per technical specification attached i/c Providing suitable wall/floor mounting bracket, water connection from the available water inlet points with suitable C.P. angle valve and outlet upto the nearest drain with suitable PVC pipe, complete etc. as required.Capacity:- 50 LPH CapacityMembrane:- 75/100 GPD (4 Nos)Input Power Rating:- 230 Volt AC, 50 Hz % of Rejection in TDS - 90% (Approx.)Indicator:- TD level of output water Tank full indication Audio Beep and No waterAuto Flush TimerDry Run ProtectionU.V. Sterilization
37Note:- During the preparation of any running or final bill by the contractor it is essential that the contractor shall submit GST paid invoice, E-way bill and delivery challan for all items without these documents the bill will not be considered submitted in proper form & shall be returned back to the contractor by Junior Engineer (E). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57528740
AUTHORITY Government Departments
TENDER VALUE 9.42 Lakhs
LAST DATE 21-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for repair maintenance Electrical & Mech. Services At Nes Electrical Division M-251, Delhi. (Sh:- Miscellaneous E & M Works At Various Pwd Sites)
Basic Detail
Tender No 76/EE(E)/PWD NES ED/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 15 Sep 2026
Submission Date 21 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 9.42 Lakhs
Tender Fee Ref. Documents
EMD 18845
Exemption Available
Document List
7e240b75-659e-4b2b-ae09-fc491b1a545f.html
BOQ_398067.xls
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

7e240b75-659e-4b2b-ae09-fc491b1a545f.html

xls

BOQ_398067.xls

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders