Tender For Special Repair Bldg No T-7, T-13, T-14, T-15 & T-16 And special Repair To Hard Standing And Allied Works At Repair Bay Of Fd Wksp Coy At Shivmandir In Sukna Mil Stn Under Ge Sukna.
Tender Value
79.83 Lakhs
Estimated cost
Bid Submission
15 Oct 2026
24 days left
EMD
1.44 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gangtok → sikkim
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair Bldg No T-7, T-13, T-14, T-15 & T-16 And special Repair To Hard Standing And Allied Works At Repair Bay Of Fd Wksp Coy At Shivmandir In Sukna Mil Stn Under Ge Sukna.
BOQ
| Sl. No. | Item Description |
| 1 | S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specified |
| 2 | S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specified |
| 3 | Dismantling old CGI/PGI sheets of any description as in roof covering complete |
| 4 | Dismantling unframed timber scantling 40Sqcm and over in section in any position. |
| 5 | M & L mild steel work as in tubular trusses including special shaped washer etc complete in using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240 complete all as specified and directed. |
| 6 | Erection only mild steel work as in tubular trusses including special shaped washer etc complete in using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240 complete all as specified and directed. |
| 7 | Dismantling wrought iron or mild steel / structural steel work of any description not otherwise provided for complete all as specified and directed. |
| 8 | S & F Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with attachment conforming to Fe-410-W and gde-E-250 as in gusset plate |
| 9 | S&F mild steel screw bolts (machine made) dia 16 to 20mm and length exc 22.5cm but n.exc 30cm with hexagonal or square heads at one end or screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut |
| 10 | Taking down chowkat with shutter without taking off shutter from the frame exc 1.5 Sqm n.exc 4 Sqm each |
| 11 | Taking down chowkats with shutter (without taking off shutter from the frame) not exc 1.5 Sqm each. |
| 12 | S&F 125X60mm size pressed steel door frames of doors with one or more rebates including necessary fixing lugs, hinges lock strike plate, etc complete as specified |
| 13 | S & F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides and covered on both side with 6mm thick decorative face veneer with lipping/frame to match all as specified and directed. |
| 14 | S&F factory made wire guazed (panel will be wire guazed in lieu of plain PVC sheet) PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top rails, bottom rails stiles & lock rail. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. The wire gauze shall be wrapped on an additional square 8 mm MS Solid tube and this tube shall be welded to MS tubes. The wire gauge shall be stretched to tighten firmly complete all as specified and directed. Note:- Wire cloth / wire mesh shall be measured seperately |
| 15 | M&L for anodised aluminium power coated frame for doors, sliding window three track ,ventilator etc with one or more rebates including all jointing cleats,etc complete all as specified and directed. |
| 16 | M &L anodised aluminium powder coated (Thick not less than 50 micron) aluminium window and ventilator shutter , slide type without sash bars,aluminium section weighing 0.55 kg /m including necessary jointing cleats,glazing clips,ruber packing, anodised aluminium snap beading, screw, including all fitting etc complete all as specified and directed. |
| 17 | S&F 4.80 mm thick plain sheet glass, ordinary quality fixed with aluminium frame work exc 0.5 sqm in each pane. |
| 18 | S& F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples. |
| 19 | M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge |
| 20 | S&F for 10 mm thick Toughned glass (eteching as required) as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required and Double action floor spring hydraulically regulated complete all as specified and as directed. |
| 21 | S&F framed work such as grills, grating, etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders; framed baluster; walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 22 | S&F 250 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed. |
| 23 | S&F of 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed, all as specified and directed. |
| 24 | S&F of 150mm size extruded aluminium alloy handles, fabricated type, anodised, all as specified and directed. |
| 25 | M&L for plain cement concrete (1:3:6), type C1 (using 20mm graded crushed stone aggregate) as in bed plate and filling in pressed steel door frame, lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed. |
| 26 | S&F in repairs Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as directed and specified. |
| 27 | M&L Brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 all as specified |
| 28 | M&L Brick work with sub class 'B' bricks straight or curved on plan any radius in half Brick thick wall built in cement mortar 1:4 complete all as specified and directed . |
| 29 | M&L for brick work with subclass 'B' bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 and pointed cement mortar 1:6 with using old size bricks(Except brick ) |
| 30 | M&L for brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 with using old size brick (Except brick ) |
| 31 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, for ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling. Complete all as specified and directed. |
| 32 | M&L Rendering 15 mm thick on other than fair faces of brick work or concrete sur-faces in cement mortar 1:6 for finished even and fair complete all as specified and directed |
| 33 | M&L Rendering 15 mm thick on fair faces of brick work or concrete sur-faces in cement mortar 1:4 using water proofing compound @ 3% by wt of cement for finished even and smooth (without using extra cement) (WPC will be measured and paid separately) |
| 34 | Taking down cement plaster on Brick or concrete surfaces incl racking out joints hacking for key scrubbing down with water etc complete |
| 35 | M&L for prepration of new plastered surfaces of wall applying two coat of oil emulsion distemper over a coat of alkali resistant cement primer over 2mm thick of wall care putty to obtained smoothness of plastered surfaces complete all as specified and directed. |
| 36 | M&L preparation of new plastered wall surfaces and including applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 37 | M&L preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 38 | M&L for two coat of synthetic enamel paint (1st grade quality) over a primed new steel surfaces of girth 10 cm incl preparation of surfaces. |
| 39 | M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick Screed bed or bedding layer for laying floor finishes in CM 1:6 etc complete all as specified and directed by Engr-in-charge. |
| 40 | All as per Sl item No 39 above but in skirting / dado etc. laid over and including backing coat 10 mm thick in CM 1:4. |
| 41 | M/L Glazed ceramic tiles 350x250x7mm / 450x350x7mm mm thick coloured tiles as in dado, skirting and vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick 1:4 cement mortar including roughening surface of old concrete complete all as specified. |
| 42 | Dismantling of floor, hearth or wall tiles including cement mortar bedding ( but not backing) and remvoing rubbish off the premishes all as per specified and directed. |
| 43 | M&L 75 mm thick Cement concrete type C-2, 1:3:6 (40 mm graded stone aggregate) for sub base filling complete all as specified and directed. |
| 44 | M&L 2nd class hard wood plain fillets, square, rectangular or triangular in section exc 13 & not exc. 25 sqcm, wrought, fixed with screws/nails complete all as specified and as directed. |
| 45 | M&L 18/19mm thick pre-laminated medium density fibre (MDF) board, both side laminated of approved colour, medium density, flat pressed single layer type or three layer type with BWR type adhesive, fixing with screw to timber/steel frame work complete all as specified and as directed. |
| 46 | Dismantling boarding, any description fixed in any position with nails/screws including frame work complete all as specified and as directed. |
| 47 | S&F 75mm long Butt hinges extruded brass with brass/bronze hinge pin, bright polished and fixed complete all as specified and as directed. |
| 48 | S&F 75mm long Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and as directed. |
| 49 | S&F 40mm dia, brass polished cupboard knobs fixed with nut, screw and washer of brass, bright finished complete all as specified and as directed. |
| 50 | M&L RCC 1:2:4 type B1 (20 mm graded aggregate) as in slabs supported on walls, beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 51 | M&L for RCC B1 1:2:4 with using 20mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 52 | M&L for RCC (nomial mix) type B1 1 :2:4 with using 20mm graded stone agg as in Chajjas complete all as specified and as directed. |
| 53 | Demolition of RCC in any description description and in any position complete all as specified and as directed. |
| 54 | Formwork to soffits of suspended slabs such as roof slabs , floorslabs ,landing and similar work not exc 200 mm thick (horizontal or slope) complete all as specified and as directed. |
| 55 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, slab cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc and finished rough surfaces of concrete flat complete all as specified and as directed. |
| 56 | M&L for Formwork to sides of rough finished flat surfaces of concrete chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed. |
| 57 | M&L for Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 58 | All as per Sl item 57 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed. |
| 59 | Supply only liquid water proofing compound complete all as specified and directed. |
| 60 | M & L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in marble dust with admixture white cement (1:2) using of pigment to match with shade of granite including cutting and polishing types over 20mm thick screed bed in CM(1:6) complete all as specified and directed. |
| 61 | M&L for 75mm thick PCC(1:3:6) Type C2 using 40mm graded stone aggregate and finished even and smooth without using extra cement as in plinth protection complete all as specified and directed. |
| 62 | Demolition of cement concrete in ground floor and paving not exc 15 cm thick below or above ground level complete all as specified and directed. |
| 63 | S&F 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to Anodised aluminium snap grid frame size 605x605 mm work for false ceiling Hangers with 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed incl necessary demolition ceiling boards any thickness incl cover fillets complete. |
| 64 | S&F in Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing including dismantilng of old sheets complete all as specified and directed. |
| 65 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 66 | M&L for 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand Complete all as specified and directed. |
| 67 | M&L for chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick set and jointed and pointed in neat cement slurry in floor with grey cement and pigment over and including cement screed 15 mm thick in CM 1:6 complete all as specified and directed. |
| 68 | M & L 100 mm thick PCC 1:4:8 Type D-2 (using 40 mm graded aggregate) footpath/ sub base filing/ path/ base for hard standing Complete all as specified and directed. |
| 69 | Demolition of cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 70 | M&L for Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 71 | M&L PCC Type C1, 1:3:6 with using 20mm graded stone aggregate as in kerbs for sides of path, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and includes formwork straight or curved as directed. |
| 72 | Taking down carefully existing copper/aluminum point wiring (Light, fan, socket or power) complete including fixture and fittings such as switches , ceiling roses , pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surfaces of walls, floors etc as per existing specification complete all as specified and as directed by Engr-in-Charge. |
| 73 | M & L for point wiring with two single core 1.5 sqmm concealed wiring ,PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc. complete all as specified & as directed for the following :- |
| 74 | One Light point controlled by one switch 5/6 Amps. |
| 75 | One bell point controlled by one switch 5/6 Amp |
| 76 | One fan/exhaust fan point controlled by one switch 5/6 Amps. |
| 77 | One switch socket outlet point 5/6 Amps on independent board. |
| 78 | One switch socket outlet point 5/6 Amps on same board. Please Enable Macros to View BoQ information |
| 79 | One switch socket outlet point 5/6 Amps on same board. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 24 daysOct 16, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender