Tender For General-Budget 2025-26(20% Provision) Development And Beautification Of Thaliparamba 7Th Mile Junction-In Kannur Distric-Providing Decorative Lights-General Electrical Work
Tender Value
8.35 Lakhs
Estimated cost
Bid Submission
23 Sep 2026
1 days left
EMD
20888
Bank guarantee accepted
Document Fee
1845
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kannur → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for General-Budget 2025-26(20% Provision) Development And Beautification Of Thaliparamba 7Th Mile Junction-In Kannur Distric-Providing Decorative Lights-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Footpath Lighting |
| 2 | OD29280/2026-2027:Supply installation testing commissioning of Decorative Pole 3.2/3 meter height above theground level made out of GI, tubular pole having two section section, bottom section ofminimum 900/1000mm with base dia of 114mm and upper section of minimum 2300/2000mmwith minimum dia of 60mm. The pole shaft shall be as per IS 1161. The pole shall have base plate ofdimension 200x200x12mm/round minimum 200mm including minimum16mm diameter 4 numbers foundation bolts of450mm bolt length, 200mm pitch circle diameter manufactured from special steel along withnuts, washers, The pole shall be with inbuilt control gear tray at bottom section. The controlgear tray is prewired with 1.5 Sq.mm cable, 6A SP MCB and 32A stud type 4 wayterminal block for loop-in / loop-out arrangement, 6 A 2 Way terminal connector and provisionfor earthing.The pole shall be suitable for wind loadings as per IS 875 part 3 1987. Designcomply EN40 standard and basic wind speed 169kmph. Pole should hot dip galvanized to 65microns to IS 2629:985/ IS 4759:1996 / IS 2633:1986. The Pole should be given with two coatsof epoxy primer and above that it should be given marine coating. The complete system shouldbe hot dipped Galvanised. (Kesslec ECO/K lite COLOMBIA/eqvt ). |
| 3 | OD29283/2026-2027:Supply Installation, testing and commissioning of 45W Decorative classic LED street lantern, BIS certified with a luminaire body made of spun and cast aluminium, permanently sealed optical block (IP66) with heatsink and a clear/Opal PMMA protector (IK07), control gear compartment accessed from top for ease of serviceability. Excellent photometry to optimally cater to different applications. Suitable for vertical mounting for 60mm diameter pipe. Highly efficient temperature resistant lenses for symmetric light distribution with several optical options providing excellent photometry to optimally cater to different applications. Overallsystem efficiency of 100lm/W at correlated colour temperature (CCT) of 3000K colourrendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I ratedvoltage 240Vac, Power Factor ? 0.95, with BIS certified potted driver having internal surgeprotection of 4/4 kV and an additional surge protection device (SPD) of 10/10 kV (in bothCommon & Differential Modes). (Kesslec Aden 45W WW LED/ Techno commercial equivalent model of reputed company) |
| 4 | 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 5 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 6 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 7 | OD82554/2026-2027:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel as required. |
| 8 | 90.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 9 | 90.12.5.3:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sq mm |
| 10 | 9.1.2:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (19mm) |
| 11 | 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 12 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 13 | OD29275/2026-2027:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation 32/40 mm or nearest size |
| 14 | OD29284/2026-2027:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench 32/40 mm or nearest size |
| 15 | 90.16.2.4:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class) |
| 16 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 17 | 90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG) |
| 18 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 19 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 20 | 90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet |
| 21 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board |
| 22 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 23 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 24 | OD82653/2026-2027:Supply and fixing 25A AC3, MNX 25, 2 Pole power contactor (L&T) conforming to IS/IEC 60947-4-1 & IEC60947-4-1 in the existing enclosure and giving connection as required- |
| 25 | OD29285/2026-2027:Supply and fixing Digital Time switch 240V AC DIN/BASE mounting in the existing enclosureand giving connection as required- (L&T110-240 V Digital Time Switch 67DDTO) |
| 26 | OD29282/2026-2027:Supply and fixing 32A HRC fuse base with HRC fuse link- |
| 27 | OD29277/2026-2027:Supply and fixing of Neutral link 32 A, 2 Way neutral links mounted on DMC/SMC base- |
| 28 | 1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 29 | 90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run |
| 30 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 31 | OD82656/2026-2027:Supply and providing test joint for the earthing system using 2 Nos of the following sizes of strips including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required. 2 x 25 x 3 mm GI strip |
| 32 | OD82657/2026-2027:Supply and providing earth lead from the test joint to the earth electrode using the following sizes of conductors/ strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required.25 mm X 3 mm G.I. strip |
| 33 | OD82709/2026-2027:Supply and laying bare earthing conductors of the following sizes laid 0.75 m belowground level including excavating trench of suitable size and refilling etc. as required(in ordinary soil).3.15 mm copper conductor (10 SWG) |
| 34 | OD29276/2026-2027:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 25x6 mm brass nut and bolt |
| 35 | OD29286/2026-2027:Supply and fixing 32mm dia 6Kgff/cm2 PVC Pipe including fixing the pipe withclamp/clips atetc. as required (for service pipe) |
| 36 | OD29278/2026-2027:Hire and Labour charges for Conreate core cutting Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 daySep 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender