Tender For Construction Of 132Kv Dedicated Transmission Line To Traction Sub-Station Of Imphal Railway Station On Turnkey Basis
Tender Overview
Project Description
Tender for Construction Of 132Kv Dedicated Transmission Line To Traction Sub-Station Of Imphal Railway Station On Turnkey Basis
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-Sep-2026 | Corrigendum for Construction of 132KV dedicated transmission line to traction Sub-Station of Imphal Railway Station on turnkey basis. | Technical Bid | 08-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | A. 132KV TRANSMISSION LINE |
| 2 | Towers |
| 3 | i) DC+6 (C-type Tower) (2 to 30 Degree) |
| 4 | ii) DD+6 (D-Type Tower) (30 to 60 Degree) |
| 5 | ii) DD+18 (D-Type Tower) (30 to 60 Degree) |
| 6 | Galvanised Bolts & Nuts with spring washers |
| 7 | Templates adjustable for |
| 8 | i) DC-Type Tower (0 to 30 Degree) |
| 9 | ii) DD-Type Towers( 30 to 60 Degree) |
| 10 | iii) DD+18 Type Tower (0 to 30 Degree) |
| 11 | iv) Galvanised Bolts & Nuts |
| 12 | Tower accessories |
| 13 | i) Pipe Earthing |
| 14 | ii) Danger Plate |
| 15 | iii) Number Plate |
| 16 | iv) Phase Plate(Set of Three) |
| 17 | v) Bird guard (Set of three) |
| 18 | vi) Anti climbing device(with Barbed wire) |
| 19 | Conductor ACSR \\"Panther\\" |
| 20 | Conductor accessories |
| 21 | i) Compression Joint |
| 22 | ii) Repair Sleeve |
| 23 | iii) Vibration Damper |
| 24 | iv) P.G. Clamp |
| 25 | Earth / Ground wire(7/3.66cm) |
| 26 | Earthwire/Ground wire accessories |
| 27 | i) Compression Joint |
| 28 | ii) Tension Clamp |
| 29 | iii) Vibration Damper |
| 30 | iv) Repair Sleeve |
| 31 | v) Earth Bond |
| 32 | Disc Insulator |
| 33 | i) 120KN |
| 34 | Hardware for Insulator Strings |
| 35 | i)Single Tension fittings |
| 36 | ii)Double Tension fittings |
| 37 | Tool & Plants |
| 38 | i)Hydraulic Compressor (100MT) HMT |
| 39 | ii)Hand Winch with 150m Rope 12 |
| 40 | iii) Come along clamp for conductor |
| 41 | iv) Come along clamp for earthwire |
| 42 | v) Pulley/Roller Heavy duty for conductor |
| 43 | vi) Pulley/Roller Heavy duty for earthwire |
| 44 | vii) Die set for panther |
| 45 | viii) Die set for earthwire |
| 46 | ix) Turn table 5 ton capacity with foot breaking arrangement |
| 47 | B. 132KV LINE BAY |
| 48 | 145KV, 12.5KA, 800A SF6 Gas Circuit Breakers, single phase or 3 phase, Auto reclosing |
| 49 | Motor Operated 145 KV, 800A, 12.5KA Out Door Isolators |
| 50 | i) with E/Blade |
| 51 | ii) without E/Blade |
| 52 | iii) Insulators for above isolators |
| 53 | 120 KV, 10KA LA with Insulating Base & Surge Counters |
| 54 | 132 KV Line CT |
| 55 | 132 KV CVT |
| 56 | 132 KV PT |
| 57 | Incomer Line Control & Relay Panel |
| 58 | Transfer Bay Control & Relay Panel |
| 59 | SWITCHYARD & COMPOUND LIGHTING |
| 60 | i) Lighting DB |
| 61 | ii) 250W SON Lamps with Fittings on Poles |
| 62 | iii) 100W LED Lamps on Switchyard structure |
| 63 | iv) Bay Marshalling Box |
| 64 | FIRE-FIGHTING EQUIPMENT |
| 65 | i) 50Lb, Dry Powder Type for switchyard |
| 66 | ii) Foam Type, 1 gallon wall mounted for battery room |
| 67 | iii) CO2, 10Lb Capacity extinguisher wall mounted for control room |
| 68 | iv) Sand Bucket (4 Ltr) stand with 6 buckets per stands for swithchyard and control room |
| 69 | D.C Equipments:- |
| 70 | i) 110V, 250AH Battery with Accessories(Maint. free) |
| 71 | ii) 110V, 250AH Battery Charger Float Cum Boost. |
| 72 | iii) 110V DC Distribution Board |
| 73 | iv) 48V, 250AH normal discharge Battery (Dry chargeable, 24 cells) |
| 74 | v) 48V Battery Charger Float Cum Boost. |
| 75 | LTAC Panel (9 feeder) |
| 76 | PLCC equipments |
| 77 | i) Line traps with connecting clamps |
| 78 | ii) PLCC terminal |
| 79 | iii) Protection coupler |
| 80 | iv) Coupling device(for phase to phase coupling) |
| 81 | GI Switchyard equipment structures (4 bays) |
| 82 | Power and Control Cables |
| 83 | Bus bar i/c insulator strings, connectors, shielding wires, conductors, post insulators etc |
| 84 | Earthing (Grid) system with GI Flats of (50x6mm) and earth electrode (GI Pipe & 75mm dia & solid/plates) |
| 85 | A. 132KV TRANSMISSION LINE |
| 86 | Towers |
| 87 | i) DC+6 (C-type Tower) (2 to 30 Degree) |
| 88 | ii) DD+6 (D-Type Tower) (30 to 60 Degree) |
| 89 | ii) DD+18 (D-Type Tower) (30 to 60 Degree) |
| 90 | Galvanised Bolts & Nuts with spring washers |
| 91 | Templates adjustable for |
| 92 | i) DC-Type Tower (0 to 30 Degree) |
| 93 | ii) DD-Type Towers( 30 to 60 Degree) |
| 94 | iii) DD+18 Type Tower (0 to 30 Degree) |
| 95 | iv) Galvanised Bolts & Nuts |
| 96 | Tower accessories |
| 97 | i) Pipe Earthing |
| 98 | ii) Danger Plate |
| 99 | iii) Number Plate |
| 100 | iv) Phase Plate(Set of Three) |
| 101 | v) Bird guard (Set of three) |
| 102 | vi) Anti climbing device(with Barbed wire) |
| 103 | Conductor ACSR \\"Panther\\" |
| 104 | Conductor accessories |
| 105 | i) Compression Joint |
| 106 | ii) Repair Sleeve |
| 107 | iii) Vibration Damper |
| 108 | iv) P.G. Clamp |
| 109 | Earth / Ground wire(7/3.66cm) |
| 110 | Earthwire/Ground wire accessories |
| 111 | i) Compression Joint |
| 112 | ii) Tension Clamp |
| 113 | iii) Vibration Damper |
| 114 | iv) Repair Sleeve |
| 115 | v) Earth Bond |
| 116 | Disc Insulator |
| 117 | i) 120KN |
| 118 | Hardware for Insulator Strings |
| 119 | i)Single Tension fittings |
| 120 | ii)Double Tension fittings |
| 121 | Tool & Plants |
| 122 | i)Hydraulic Compressor (100MT) HMT |
| 123 | ii)Hand Winch with 150m Rope 12 |
| 124 | iii) Come along clamp for conductor |
| 125 | iv) Come along clamp for earthwire |
| 126 | v) Pulley/Roller Heavy duty for conductor |
| 127 | vi) Pulley/Roller Heavy duty for earthwire |
| 128 | vii) Die set for panther |
| 129 | viii) Die set for earthwire |
| 130 | ix) Turn table 5 ton capacity with foot breaking arrangement |
| 131 | B. 132KV LINE BAY |
| 132 | 145KV, 12.5KA, 800A SF6 Gas Circuit Breakers, single phase or 3 phase, Auto reclosing |
| 133 | Motor Operated 145 KV, 800A, 12.5KA Out Door Isolators |
| 134 | i) with E/Blade |
| 135 | ii) without E/Blade |
| 136 | iii) Insulators for above isolators |
| 137 | 120 KV, 10KA LA with Insulating Base & Surge Counters |
| 138 | 132 KV Line CT |
| 139 | 132 KV CVT |
| 140 | 132 KV PT |
| 141 | Incomer Line Control & Relay Panel |
| 142 | Transfer Bay Control & Relay Panel |
| 143 | SWITCHYARD & COMPOUND LIGHTING |
| 144 | i) Lighting DB |
| 145 | ii) 250W SON Lamps with Fittings on Poles |
| 146 | iii) 100W LED Lamps on Switchyard structure |
| 147 | iv) Bay Marshalling Box |
| 148 | FIRE-FIGHTING EQUIPMENT |
| 149 | i) 50Lb, Dry Powder Type for switchyard |
| 150 | ii) Foam Type, 1 gallon wall mounted for battery room |
| 151 | iii) CO2, 10Lb Capacity extinguisher wall mounted for control room |
| 152 | iv) Sand Bucket (4 Ltr) stand with 6 buckets per stands for swithchyard and control room |
| 153 | D.C Equipments:- |
| 154 | i) 110V, 250AH Battery with Accessories(Maint. free) |
| 155 | ii) 110V, 250AH Battery Charger Float Cum Boost. |
| 156 | iii) 110V DC Distribution Board |
| 157 | iv) 48V, 250AH normal discharge Battery (Dry chargeable, 24 cells) |
| 158 | v) 48V Battery Charger Float Cum Boost. |
| 159 | LTAC Panel (9 feeder) |
| 160 | PLCC equipments |
| 161 | i) Line traps with connecting clamps |
| 162 | ii) PLCC terminal |
| 163 | iii) Protection coupler |
| 164 | iv) Coupling device(for phase to phase coupling) |
| 165 | GI Switchyard equipment structures (4 bays) |
| 166 | Power and Control Cables |
| 167 | Bus bar i/c insulator strings, connectors, shielding wires, conductors, post insulators etc |
| 168 | Earthing (Grid) system with GI Flats of (50x6mm) and earth electrode (GI Pipe & 75mm dia & solid/plates) |
| 169 | A. 132KV TRANSMISSION LINE |
| 170 | Survey |
| 171 | i) Detail survey |
| 172 | ii) Check survey & Profile |
| 173 | iii)Jungle Cutting |
| 174 | Setting of Stubs |
| 175 | i) DC+6 Type Tower |
| 176 | ii) DD+6 Type Towers |
| 177 | iii) DD+18 Type Tower |
| 178 | Erection of Tower |
| 179 | i) Tower |
| 180 | iii) Galvanized Bolts & Nuts |
| 181 | Stringing of panther Conductor |
| 182 | Stringing of Earthwire |
| 183 | Excavation works |
| 184 | i) Normal dry soil |
| 185 | ii) Soil Investigation (L.S.) |
| 186 | Concreting works |
| 187 | i) P.C.C. 1:2:4 (L.S.) |
| 188 | ii) Reinforcement Steel (L.S.) |
| 189 | iii) Back filling and gap levelling of Volumes |
| 190 | Installation of Conductor Accessories |
| 191 | i) Compression Joint |
| 192 | ii) Repair Sleeve |
| 193 | iii) Vibration Damper |
| 194 | iv) P.G Clamp |
| 195 | Installation of Earthwire Accessories |
| 196 | i) Compression Joint |
| 197 | ii)Tension Clamp |
| 198 | iii)Vibration Damper |
| 199 | iv) Repair Sleeve |
| 200 | v) Earth Bond |
| 201 | Tack welding of Nuts & Bolts and application of Zinc rich Paints |
| 202 | Installation of Tower Accessories |
| 203 | i) Pipe Earthing |
| 204 | ii) Danger Plate |
| 205 | iii) Number Plate |
| 206 | iv) Phase Plate(Set of Three) |
| 207 | v) Bird Guard (Set of Three) |
| 208 | vi) Anti climbing device(with Barbed wire) |
| 209 | Disc Insulator |
| 210 | i)120KN |
| 211 | Hardware for Insulator Strings |
| 212 | i) Single Tension fittings |
| 213 | ii) Double Tension fittings |
| 214 | Crossing (LS) |
| 215 | i) Streams/Nullahs below 250 Mtr |
| 216 | ii) 132KV Line |
| 217 | iii) 11KV Line |
| 218 | Tower Testing Charges |
| 219 | ii) C-Type Towers |
| 220 | iii) D-Type Towers |
| 221 | B. 132KV LINE BAY |
| 222 | 145KV, 12.5KA, 800A SF6 Gas Circuit Breakers, single phase or 3 phase, Auto reclosing |
| 223 | Motor Operated 145 KV, 800A, 12.5KA Out Door Isolators |
| 224 | i) with E/Blade |
| 225 | ii) without E/Blade |
| 226 | iii) Insulator for above isolators |
| 227 | 120 KV, 10KA LA with Insulating Base & Surge Counters |
| 228 | 132 KV Line CT |
| 229 | 132 KV CVT |
| 230 | 132KV PT |
| 231 | Incomer Line Control & Relay Panel |
| 232 | Transfer Bay Control & Relay Panel |
| 233 | SWITCHYARD & COMPOUND LIGHTING |
| 234 | i) Lighting DB |
| 235 | ii) 250W SON Lamps with Fittings on Poles |
| 236 | iii) 100W LED Lamps on Switchyard structure |
| 237 | iv) Bay Marshalling Box |
| 238 | FIRE-FIGHTING EQUIPMENT |
| 239 | i) 50Lb, Dry Powder Type for switchyard |
| 240 | ii) Foam Type, 1 gallon wall mounted for battery room |
| 241 | iii) CO2, 10Lb Capacity extinguisher wall mounted for control room |
| 242 | iv) Sand Bucket (4 Ltr) stand with 6 buckets per stands for swithchyard and control room |
| 243 | D.C Equipments: |
| 244 | i) 110V, 250AH Battery with Accessories(Maint. free) |
| 245 | ii) 110V, 250AH Battery Charger Float Cum Boost. |
| 246 | iii) 110V DC Distribution Board |
| 247 | iv) 48V, 250AH normal discharge Battery (Dry chargeable, 24 cells) |
| 248 | v) 48V Battery Charger Float Cum Boost. |
| 249 | LTAC Panel (9 feeder) |
| 250 | PLCC equipments |
| 251 | i) Line traps with connecting clamps |
| 252 | ii) PLCC terminal |
| 253 | iii) Protection Coupler |
| 254 | iv) Coupling device(for phase to phase coupling) |
| 255 | GI Switchyard equipment structures (4 bays) |
| 256 | Power and Control Cables |
| 257 | Bus bar i/c insulator strings, connectors, shielding wires, conductors, post insulators etc |
| 258 | Earthing (Grid) system with GI Flats of (50x6mm) and earth electrode (GI Pipe & 75mm dia & solid/plates) |
| 259 | Civil Works |
| 260 | Land development |
| 261 | Construction of equipment & tower foundation (4 bays) |
| 262 | Construction of cable trenches |
| 263 | PCC & Stone spreading for surface insulation (4 bays) |
| 264 | 2.5Mtr (Tall above Ground Level), GI (No.10SWG) Wire Netting Switchyard Fencing with 3 Mtr long Angle Iron Post (65x65x6)mm with PCC(1:2:4) Muffing ( 1/5 of Height). Entry Iron Gate of size ( 2 x 2Sq.mtr) should also be provided (100m X 80m) |
| 265 | Total Supply of Plant and Equipment |
| 266 | Total Freight Insurance Charges |
| 267 | Total Erection Price |
| 268 | BOQ3 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 16 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender