Tender For Comprehensive Maintenance Services (B/R And E/M) Including Repair/Replacement Of Joinery, Sanitary Fitting, Roof Treatment False Ceiling,Wiring, Electrical Fitting And All Misc Works Services At Depot Regt (Corps Of Signal) Incl Somnathpur
Tender Overview
Project Description
Tender for Comprehensive Maintenance Services (B/R And E/M) Including Repair/Replacement Of Joinery, Sanitary Fitting, Roof Treatment False Ceiling,Wiring, Electrical Fitting And All Misc Works Services At Depot Regt (Corps Of Signal) Incl Somnathpuri & Khandari Farm Under Ge (East) Jabalpur.
BOQ
| Sl. No. | Item Description |
| 1 | Schedule \\"A\\" |
| 2 | Dismantling of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articlesas in walls/parapet wall,s removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces . |
| 3 | M&L for Brick work with sub class ‘B’ brick, straight or curved as plan exc 6m mean radiusbuilt in cement mortar 1:6 complete . |
| 4 | M&L for Brick work with sub class ‘B’ brick, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete . |
| 5 | Taking down cement plaster / terrazzo of any description thickness including raking out joints hacking for key scrubbing down with water all as specified. |
| 6 | M&L for 15 mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all specified and directed. |
| 7 | M&L rendering on concrete/brick surfaces 15mm thick in CM 1:4 surface finished even and smooth without using extra cement complete all as specified |
| 8 | M&L 5mm thick rendering in Cement Mortar 1:3 on Concrete Surfaces, ceiling etc finished surface Even and Smooth, without using extra cement |
| 9 | M&L for preparation of newly plastered surfacces and applying three coat of white wash as in ceilling complete all as specified and as directed. |
| 10 | M&L for Preparing Newly Plastered Surfaces of internal wall and applying two Coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and as directed. |
| 11 | M&L for Preparing Newly Plastered Surfaces of external wall and applying two Coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and as directed. |
| 12 | M&L 3mm thick wallcare putty on wall complete |
| 13 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces & also providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth. complete all as specified and directed. |
| 14 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets including E- Grid frame work complete all as specified and directed. |
| 15 | S&F suspended false ceiling system using Chicago metallic (E-grid) exposed suspended system, grid size 600x600mm compressing of GI powder coated main runner of dimension 39mmx24mm x 0.8mm thick (Thickness comprising of GI/0.5mm+PPPCGS/0.3mm & weight of runner 1.35 Kg for 3600mm length), cross Tee of dimension 29mm x 24mm x 0.7mm thick (Thickness comprising of GI/0.5mm+PPPCGS/0.3mm & weight of Tee 0.195Kg for 600mm length) and wall angle of dimension 22.2mm x 22.2mm x 0.65mm thick (Thickness comprising of GI/0.35mm + PPPCGS/0.30mm & weight of angle 0.700 Kg for 3050mm length) with and including 4mm thick HSPC (High Pressure Steam Cured) pre-primed, self embossed, textured designer board, water, termite & fire resistant for insulation and acoustic purpose to be placed in the grid system duly suspended with 4mm dia GI bar hangers fixed with steel dash through fasteners from purlins with butterfly clips (wt 0.007 Kg/clip), hold down clips (wt - 0.0035 Kg/clip), with provn of light fixture complete all as per manufacturer instructions and as directed. (Make : Armstrong/Everest). |
| 16 | Fixing only 6mm to thick in ceiling flat or sloping Non asbestos cement building boards fixed or laid/inserted to timber/GI/Aluminium frame work fixed with screw as per manufacturer's instructions all as specified and directed |
| 17 | Dismantling of asbestos cement (corruga ted, semicorrugated, etc.) sheets in roof coverings |
| 18 | M&L Pre-painted galvatume aluminium zinc coating GI based corrugatged steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified. |
| 19 | M&L Pre-painted galvatume aluminium zinc coating GI based corrugatged steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified |
| 20 | M&L for 6mm thick asbestos cement,corrugated and semi corrugated sheets in roof fixed with L- type or J type or crank hook bolts all as specified and directed. |
| 21 | Fixing only 6mm thick asbestos cement,corrugated and semi corrugated sheets in roof fixed with L- type or J type or crank hook bolts all as specified and directed. |
| 22 | Dismantling timber fillets,posts rafter purlin under 40 sqcm framed work in sectional area,complete all as specified and as directed. |
| 23 | Dismantling timber in scantling 40 Sqcm and over in section framed work in any position complete all as specified and directed. |
| 24 | Dismantling wroght iron or mild steel work of any description not oterwise provide for |
| 25 | S&F hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc; flat iron fillets (for securing wire mesh etc,) including all necessary drilling bolting or riveting, etc and similar work conforming to Fe410-0 or Fe 310-0 complete all as specified and directed. |
| 26 | Fixing only wind ties all as specified and as directed. |
| 27 | S&F mild steel screw bolt (machine made) with square or hexagonal head at one end, screwed other, fitted with washer and one hexagonal or square n exc 5cm, long and 5 to 10mm dia complete all as specified and directed. |
| 28 | S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to a common rafters, fixed with angle cleats or other connecting plates of Gde Fe 410 -W (Gde E- 250)Quality - A , complete all as specified and directed. |
| 29 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in lintels upto 1.5 clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers ,apex stones, bed plates, water troughs and the like including use of formwork (straight or curved) ,including weathering, slightly rounded or chamfered angles and throating, all as specified and as directed (Note :-reinforcement where provided shall be measured and paid seprately) |
| 30 | M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed. |
| 31 | Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9 mm dia or securing with clips complete. |
| 32 | Mild steel TMT bars 5 mm and over upto and including 10 mm dia in stirrups,spaces and binders cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire ( annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 33 | Dismantaling floor hearth or wall tiling/china moisac including cement mortar bedding (but not backing ) , removing serviceable tiles to store and rubbish off the premises complete all as specified. |
| 34 | M&L for glazed ceramic coloured tiles of size 450 x 300 x 6 to 7 mm,450x350 or 350x250 6 to 7mm thick on vertical surface such as skirting/dado etc. ,set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile with & including rendering 10 mm thick cement plaster in cement mortar 1:4 finished rough to fix tiles complete all as specified and directed. |
| 35 | Glazed ceramic Coloured tiles 300mmx200mm x 6 to 7 mm thick, on vertical surfaces of walls ( DADO) etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match ( in patches to match the existing colour /shed) over and including 10mm thick rendering in CM 1:4 all as directed. |
| 36 | M&L Non skid coloured ceramic tiles 7 to 8mm thick square/ rectangular area of Each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match, laid over and including 15mm thick cement screed bed in cement mortar 1:6 complete all as specified and directed. |
| 37 | M&L for joint free Non Skid coloured ceramic tiles 7 to 8 mm thick square / rectangular) area of Each tile coloured exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match ( in patches to match the existing colour /shed) over and including screed bed 15mm thick rendering in CM 1:6 all as directed. |
| 38 | M&L Vitrified ceremic tiles (9 to 10 mm thick), in LIGHT SHADE, (Square/rectangular) polished, area of Each tile not exceeding 0.36 Sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specfied and directed. |
| 39 | M&L for Vitriefied ceramic tiles (9 to 10 mm thick) LIGHT SHADE(square/rectangular) polished area of Each tiles not exceeding 0.36 Sqm as in vertical surfaces such as dados/skirting etc set and jointed in neat cement slury and in coloured cement to match Coloured including plaster (backing coat) 1:4 CM 10mm thick complete all as specified and directed. |
| 40 | M&L for Granite (of any type ) 20 mm thick work (table rubbed and polished ) in steps ,jambs,pilllars,window cill,cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2)using marble dust with admixture of pigment to match with shade of Granite laid over 20mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 41 | Demolition of cement concrete in ground floor and paving not exc 15cm thickness (below or above ground level) all as specified. |
| 42 | M&L for 25MM thick cement concret Type B-1 1:2:4 (Using 20mm graded stone aggregate ) complete all as specified and directed. |
| 43 | M&L 75 mm thick PCC 1:4:8 type D2(using 40 mm graded stone aggregate) as in sub base complete all as specific and direction |
| 44 | Material and labour 20- 25 mm thick machine cut kota stone flooring 20 to 20 mm thick over cement screed base laid and jointed with neat cement slurry mixed with pigment to match the shade of the slab laid over 20 mm thick bedding layer in cement mortar 1:6 including rubbing and polishing complete all as specified.. |
| 45 | M&L 20 to 25 mm thick machine cut kota stone as in vertical surfaces risers of steps , skirting, dado and pillars etc set and jointed in neat cement slurry and pointed with grey cement mixed with pigment to match the colour of stone slab laid over and including 10 mm thick rendering in cement mortar 1:4 including rubbing and mirror polishing complete all as specified. |
| 46 | M&L 75 mm thick PCC 1:3:6 type C-2 using 20mm graded aggregate as in plinth protection finishing even & fair without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 gde and three part of sand ( all by weight) complete. |
| 47 | Taking down chowkhats or frame (with shutter w/o taking off shutter from the frame) area not exc 1.5 Sqm Each all as specified. |
| 48 | Taking down chowkhats or frame (with shutter w/o taking off shutter from the frame) area exc 1.5 Sqm but n-exc 4 Sqm Each . |
| 49 | Taking down Shutters of any description n.exc 1 Sqm Each |
| 50 | Taking down Shutters of any description exc 1 Sqm but n exc 2.0 Sqm Each |
| 51 | Refixing of shutters including taking down easening and adjusting and also refixing hardware as required including renewal of unserviceable screws etc. of any description n exc 1.0 Sqm Each, in same opening all as specified and as directed. |
| 52 | S&F pressed steel door frame 105x60 mm with one or more rebated incl necessary fixing lugs hings, lock strick , etc complete, as specified and directed. |
| 53 | Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed ® size 125x 60 mm |
| 54 | S&F 2nd class H/W plain solid straight chowkhat or frame, wrought framed rebated on the solid, rounded or chamfered put together with flue pinned at joints etc and in position . |
| 55 | S&F, Powder coated (minimum thickness of powder coating 50 micron) Aluminium anodised sections for doors/windows/ventilators with one or more rebates including joining cleat for fixing etc complete with frames, shutters and grills of size directed by Engineer-in-charge including handles, tower bolts, grills, etc complete all as specified and directed. Note:- Floor door spring, sheet glass, wire cloth, lock, etc shall be measured and paid seperately. |
| 56 | M&L PCC 1:3:6 type C1 using 20mm graded stone aggregate as in filling of pressed steel door frame complete all as specified and directed. |
| 57 | S & F 30 mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides decorative face veneer with lipping/frame to match supplied and fitted to chowkats, complete all as specified and directed. |
| 58 | S & F 30 mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides supplied and fitted to chowkats.all as specified and directed. |
| 59 | S & F factory made 35 mm thick plain, framed, panelled shutters (Two panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces and size of the members of shutter are as per IS – 1003 (Part – I) made of kiln seasoned & chemically pressure treated 2nd class hardwood rail and style complete all as specified and directed. |
| 60 | S & F 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part -I,section 8,clause 8.24 (a) complete all as specified and as directed.fitted to chowkhats for doors etc complete. |
| 61 | S&F for 30mm 2nd class H/W glazed skelton shutter for window/ventilator, open rebated and prepared to receive glass , gauze etc (with sash bars) edges of framing plain chamfered or rounded , fitted with cut and mitered beads for securing glass etc; size of members of shutters as specified in SSR Part -I,section 8,clause 8.24 (a) complete all as specified and as directed. |
| 62 | S&F steel windows with side hung shutter including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or weldedcomplete all as specified and directed. |
| 63 | S&F steel windows with side hung shutter including projecting type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or weldedcomplete all as specified and directed. |
| 64 | S&F steel windows or ventilators, fixed type with glazing bars. |
| 65 | S&F PVC door frame size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinf with MS square tube supplying & fixing in opening as per specificationn make Rajshree. |
| 66 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails . M,S frame shall be covered with heat moulded plain colour PVC ,C, channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rails , lock rails and bottom rails on either side and as gap insert for top rail and bottom rail Panelling of plain colour PVC sheet to be fitted in the M.S frame welded /sealed to the stiles & rails with suitable PVC sheet beading , and jointed together with solvent cement , supplying and fising in the frame at site as per specification and drawing. Make Rajshree |
| 67 | S&F, aluminium anodised, barrel tower bolts of extruded section with length of bolt 200 mm and fixed complete all as specified and directed |
| 68 | S&F, aluminium anodised, barrel tower bolts of extruded section with length of bolt 150 mm and fixed complete all as specified and directed |
| 69 | S&F, aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy with length of bolt 300 mm and fixed complete all as specified and directed. |
| 70 | S&F, 100mm butt hinges extruded aluminium alloy with galvanised mild steel hinge pin,Type-B-21 complete all as specified and directed. |
| 71 | S&F mild steel cold rolled medium weight butt hinges 75mm size fixed screws to wooden frames or with welding to steel frames all as specified and directed by Engr-in-charge. |
| 72 | S&F continuos (piano) hinges,mild steel bright finish or electrogalvanised,width of flaps 30 mm all as specified and directed. |
| 73 | S&F extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed. |
| 74 | S&F extruded aluminium alloy handles, fabricated type, anodised of size 125 mm complete all as specified and directed. |
| 75 | S&F 150mm long floor door stopper of aluminium alloy body and tongue with hard drawn steel springcomplete all as specified and directed. |
| 76 | S&F door closer hydraulically regulated designation No-2 universal type of aluminium body fixed to door frames with screws or by welding complete for door shutters of 850 to 1000mm in width all as specified and directed by Engr-in-charge. |
| 77 | S&F 300mm long mild steel ordinary rat tail rod pattern springs,including roller and roller plate complete all as specified and directed. |
| 78 | S&F 125mm hasp and staples,aluminium anodized including bolt to hinges plate and fixed with screws complete all as specified and directed |
| 79 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staple/ wooden beads complete all as specified. |
| 80 | S&F in repair 9 mm thick prelaminated particle board interior grade,prelaminated both sides with decorative choice laminaions fixed with screw to timber/steel frame work as in repair all as specified |
| 81 | S&F in repair 18/19 mm thick prelaminated particle board interior grade,prelaminated both sides with decorative choice laminaions fixed with screw to timber/steel frame work as in repair all as specified |
| 82 | S&F 3mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in Each pane complete all as specified |
| 83 | S&F 4mm thick figured glass, pinn headed type and glazing with oil putty in square n. exc 0.5 Sqm Each panes complete all as specified |
| 84 | Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new one complete all as specified |
| 85 | S&F 5.5mm thick Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in Each pane complete all as specified |
| 86 | S&F 5.5mm thick Sheet glass,ordinary quality and glazing with oil putty in square exc 0.5 sq. m in Each pane complete all as specified |
| 87 | S&F mild steel framed work conforming to Fe.290.Gde-E-165 such as guard bars/grills,grating etc with end of bars shouldered and/or riveted or forged into spikes and similar works including one shop coat of zinc chromate primer complete all as specified. |
| 88 | S&F framed work as in doors or gates of angle or other section with gusset plates ,rails,braces etc complete drilled for fixing of steel gate sheeting or other covering,doors ,etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering ,runing rails and guides ) and hanging also fastning and fixing complete all as specified and directed. confirming to FE-290 ( Gde E-165). |
| 89 | M&L for Cutting holes in brick walls in exc half brick and nexc one brick in cement in mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 complete all as specified and directed. |
| 90 | Taking down old steel tubing & connection including cleaning for refixing for 15mm bore pipe complete all as specified |
| 91 | Taking down old steel tubing & connection including cleaning for refixing for 20mm bore pipe complete all as specified |
| 92 | Taking down old steel tubing & connection including cleaning for refixing for 25mm or 32 mm bore pipe complete all as specified |
| 93 | S & F Tubes medium grade, 15mm bore galvanised with all fittings and fixed complete to wall (Conceiled)and ceiling or laid in floors Complete all as specified and directed. |
| 94 | S&F Tubes medium grade, 20mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors Complete all as specified and directed. |
| 95 | S&F Tubes medium grade, 25mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors Complete all as specified and directed. |
| 96 | Re-fixing Tubes medium grade, 15mm bore galvanised with all fittings and fixed complete to wall (Conceiled)and ceiling or laid in floors Complete all as specified and directed. |
| 97 | Re-fixing Tubes medium grade, 20mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors |
| 98 | Re-fixing Tubes medium grade, 25mm bore galvanised with all fittings and fixed complete to wall and ceiling or laid in floors Complete all as specified and directed. |
| 99 | M&L for Cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete. |
| 100 | S& F in repairs Stop valve / Angle valve fancy type cast copper alloy chromium plated screwed down high pressure with capstan heads screwed both ends for iron pipe or for union and fixed 15mm bore complete all as specified and directed. |
| 101 | S& F in repairs Stop valve / Angle valve concealed type cast copper alloy chromium plated screwed down high pressure with capstan heads screwed both ends for iron pipe or for union and fixed 15mm bore complete all as specified and directed. |
| 102 | S& F in repairs 15 mm bore bib tap cast copper alloy, chromium plated, long body fancy type with capstan headed, screwed down, screwed for iron pipe complete all as specified and directed. |
| 103 | S& F in repairs 15 mm bore chromium plated brass WHB mixer fancy type swan neck long nose screwed down high pressure with or without lettered hot and cold and flynuts 15 mm dia complete all as specified and directed. |
| 104 | S&F in repair 15mm dia pillar tap cast copper alloy chromium plated capstan head screwed down high pressure with or without lettered hot or cold with long screw shank and fly nutt screw for iron pipe |
| 105 | S&F in repair Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall Size 915mmx460mm with bowl size 410mm x330mm x 160mm . |
| 106 | S&F in repair staniless steel sink 1mm thick without drainage board for kitchen with plug , waste pipe , washers, including cantilever cast iron brackets , connecting union to waste pipe etc, overall size 495x420mm with bowl size 410x330x160mm . |
| 107 | S&F Soap dish, stainless steel approx size 160mm x 160mm x 90mm complete all as specified and directed. |
| 108 | S&F in repair PVC connection 450 mm long, 15mm size with PTMT nuts complete all as specified |
| 109 | S&F in repair PVC connection 600 mm long, 15mm size with PTMT nuts complete all as specified |
| 110 | S&F in repairs 10 ltr PVC valve less symphonic action type flushing cistern, low level white with inlet ball valve float and handle with flush pipe complete all as spfd |
| 111 | S&F in repairs grating doom 125mm dia PTMT with waste hole (Min weight 40 grms) |
| 112 | S& F in repairs chromium plated shower rose 125 mm size and 15mm dia with or without swivel joints including fixing to pipe and union complete all as specified and directed |
| 113 | S&F 600x450 bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board of commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers Complete all as specified and directed. |
| 114 | S & F in repairs Towel rail 600 mm long and 20 mm dia brass chromium plated D type fixed with screws and wooden or plastic cleats complete all as specified and directed. |
| 115 | M&L for 100mm dia cast iron floor trap plain with grating including jointing and fixed with cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 116 | M&L for 75mm dia PTMT multi floor trap plain with grating including jointing with solvent cement complete all as specified 7and directed. |
| 117 | Taking down eaves gutters and rainwater pipes (any size or pattern ),including all fittings,heads,shoes,bends,swan necks etc.including cleaning or refixing or removal to store. |
| 118 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or trenches ,110 mm bore complete all as specified. |
| 119 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or trenches,75 mm bore complete all as specified. |
| 120 | S&F PVC (SWR) bends any radius 110 mm bore complete all as specified. |
| 121 | S&F PVC (SWR) bends any radius 75 mm bore complete all as specified. |
| 122 | S&F, 75mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. |
| 123 | S&F, 110mm bore PVC (SWR) junction single, (Single T) equal or unequal with access door complete all as specified and directed. |
| 124 | S&F in repair vitreous China squatting pan of pattern Orissa Pan , size 580 x440 mm white with integral foot rests any pattertn (excl flushing cistern and flush pipe) complete incl provn of lime concrete bedding connection to flush pipe , trap etc & making good. |
| 125 | S&F in repair vitreous china wash down water closet pan Padestal pattern white excluding fixing bolts, flushing cistern and flush pipe with and incl 'P' or 'S' trap and making good to floor to match with existing all as specified and directed. |
| 126 | S&F, in repair PTMT bottle trap ( with internal partition) 32mm bore having minimum water seal of 25mm(Minimum weight 32mm-260 gms complete all as specified and directed. |
| 127 | S& F in repairs Vitreous China wash hand basin, white, flat back, size 550mm x 400mm including brass coupling, mild steel brackets fixed to wall, with pedestal complete all as specified and directed. |
| 128 | S& F in repairs Vitreous China wash hand basin, white, flat back, size 550mm x 400mm including brass coupling, mild steel brackets fixed to wall, complete all as specified and directed. |
| 129 | S&F in repairs vitreous China bowl urinal flat back of size 465x355x265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern flush pipe and waste pipe) including connections to flushing pipe and out going pipes etc complete all as specified and directed |
| 130 | S & F in repairs Vitreous china urinal half stall type ,white including connection to flushing pipe and outgoing pipe complete all as specified and directed. |
| 131 | S&F CP waste fittings brass chromium plated for WHB/sink 32mm dia with long screws sinks and fly nuts , flenge end bedded in red led cement and other in fixed all as specified and directed. |
| 132 | S&F CP waste fittings brass chromium plated for sink 40mm dia with long screws sinks and fly nuts , flenge end bedded in red led cement and other in fixed all as specified and directed. |
| 133 | M&L for Preparation of newly steel surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint complete all as specified |
| 134 | M&L for Preparation of newly wooden surface of any description over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of pink primer com all as specified. |
| 135 | S& F Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100 mm bore of pipe complete all as specified and directed. |
| 136 | S & F in repair Gun-metal, globe or gate valves 20mm, with iron wheel head, screwed both ends for iron pipe and fixed. |
| 137 | S & F in repair Gun-metal, globe or gate valves 25mm, with iron wheel head, screwed both ends for iron pipe and fixed. |
| 138 | Dismantling exc 500 and n.exc 1000 ltr cpacity water tanks and removing to store. |
| 139 | S&F for 1000 ltr capacity Rotational moulded polyethylene water storage tank (cylindrical vertical closed top) hoisted and fixed in positions all as specified in SSR Part-I,including 25 mm dia of ball valves high pressure of PTMT with epoxy coated aluminium rod &highdensity plastic ball screwed for iron pipe and fixed .Note : PVC tank shall be ISI marked and having Triple layers. |
| 140 | M & L for Machine pressed precast coloured concrete interlocking paver block M 35 grade any shape and size of 60mm thickness with grey cement and pigment complete all specified and directed. |
| 141 | M&L for 50mm thick Sand filling under floors or infoundations including watering and consolidation as in cushening layer below interlocking paver tiles well compacted to a true surface. |
| 142 | M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in Sub base of flooring, complete all as specified and directed. |
| 143 | M&L Stone kerb of machine pressed coloured precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate, block of size 30cmX30cmX15cm finished at top bullnosed shape and finished surface even and smooth using coloured pigment and jointed in CM 1:6 struck finished, applying two coats of paints in zebra pattern as directed by Engr-in-Charge |
| 144 | S & F in repair Ball brass valves(25 mm), high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed |
| 145 | Roughening surfaces of old concrete floor/terrace by picking incl. taking down existing detoriated / decayed tar felt PCC tiles or any type of treatment including loose surface, scraping with scraper, chiseling, scraping of surface with wire brush or any other method, sweeping clean & washing down with water to remove dust etc. and removing the scraped materials debris to a distance not exc. 50 m. |
| 146 | M&L for wire brushing and cleaning top surface of tiles,lime terracing or cement concrete,including flashing and junction of parapet,etc,and surface painting with a layer of blown bitumen of any penetration applied hot @1.70 kg per sqm.blinded with grit or pea size gravel @ 0.006 cu.m per sqm and lightly tampered (area of flashing etc.shall be added to the roof area. |
| 147 | M&L for 10 mm thick screed bed or bedding layer in CM 1:3 mixed with water proofing compound @ 3 % by weight of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc complete all as specified and directed. |
| 148 | M&L for APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric ( wt not less than 150 gms /sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 ltr/Sqm by forced complete all as specified and directed. Four course roof treatment consists of as under :- (a) Applying one coat of bituminous primer conforming to IS-3384 @ 0.30 Ltr per sqm.(b) Laying of APP based membrane as specified thickness and weight.(c) Applying two coat of aluminium paint @ 100ml/sqm. |
| 149 | M & L Bitumastic gola, with 80/25 bitumen and coarse sand mixture, 1:3 by weight, 8cmx8cm at the junction of roofing to vertical, complete all as specified and directed. |
| 150 | M&L for APP based polymeric membrane minimum weighing 3.50 kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 160 gm/sqm) laid over primed surface including bituminous primer conforming to IS-3384-1965 applied @ 0.3 ltr/ Sqm by forced application complete all as speficied.Three course roof treatment consists of as under :-(i) Applying one coat of bituminous primer conforming to IS-3384-1965 @ 0.30 ltr/Sqm.(ii) Laying APP based membrane as specififed.(iii) Applying a layer of blown grade bitumen 85/25 @ 1.2 Kg/Sqm conforming to IS : 702 |
| 151 | M&L for Cement concrete tiles 25 cm x 25 cm x 22 mm thick, machine pressed including provision of 15 mm thick screed bed in CM 1:4 with using water proofing compound joints shall be filled with grey cement but no pigment complete all as specified and directed. |
| 152 | M&L for fillet of 75mm size using PCC 1:2:4 type B-1 (using 20 mm graded aggregate) at the junction of all horizontal and vertical surfaces complete all as specified and directed. |
| 153 | Supply only Integral water proofing compound all as specified and directed. |
| 154 | Preparation of old decorated plastered/un-plastered surfaces of any height of walls of any description, pillars, cornices by brooming washing, rubbing down and stopping of distempered and paintefd surface wire brushing, scrubbing down smoke, soot, mould moss and efflorescent, salts, trading oil and greasy spots and applying two coat of cement base paint complete all as specified and directed. |
| 155 | All as per item No 10 but two coat on ceiling |
| 156 | ALL as per item No 10 but two coat of colour wash |
| 157 | ALL as per item No 10 but two coat of colour wash |
| 158 | ALL as per item No 10 but one coat of cement base paint |
| 159 | M&L preparing surfaces of old wooden surfaces of any description not otherwise described over 10 cm width or girth and applying, one coat of synthetic enamel paint complete all as specified. |
| 160 | All as in item No above but not exc 10 cm width or girth on wooden surface |
| 161 | M&L preparing surfaces of old steel surfaces of any description not otherwise described but applying one coats of synthetic enamel paint on old steel surface. |
| 162 | All as in item No above but not exc 10 cm width or girth on steel surface |
| 163 | Internal Electrification |
| 164 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, includingfixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and makinggood disturbed surfaces of walls, floors, etc. |
| 165 | Taking down sub main wiring complete including fitting and fixtures, removing materials for taking credit and making good disturbed surfaces of walls, floors, roof etc, all as specified and as directed. |
| 166 | Taking down carefully unserviceable DBs any type/size With MCCBs/MCBs//Isolator etc and disconnecting and making good disturbed surfaces complete all as directed. |
| 167 | M&L for complete point wiring with 1.5 Sqmm single core multi stranded copper conductor FRLS insulated and sheathed medium duty cable in colour code including continuous earth wire with cable of size 1.5 sqmm multistranded copper conductor FRLS insulated drawn in and including concealed PVC rigid conduit medium grade ISI marked terminated into GI/pressed steel modular terminal boxes etc complete all as specified and as directed for the following :- |
| 168 | One light/fan point or one fan point controlled by one swich with cable 1.5 sq. mm size complete all as specified and as directed by Enger In charge. |
| 169 | One 3 pin socket outlet, 5 amps, independent, with cables 1.5 sq. mm size |
| 170 | One 3 pin socket outlet 5 amps on the same board with other switches, with cables 1.5 sq.mm size complete all as specified and as directed by Engr In charge |
| 171 | One 3 pin 5 amps socket outlet independent but below the switch board of light points inthe same vertical plane, with cables. 1.5 sq. mm size complete all as specified and as directed by Engr In charge |
| 172 | One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sqmm size complete all as specified and as directed. |
| 173 | Ditto all as per srl item No 26 above but for one 3 pin modular socket outlet 15/16 amps independent with cable of size 2.5 sqmm for point wiring and 2.5 sqmm as in continuous earth wire. |
| 174 | M & L in of point wiring complete with 1.5 Sqmm single core multi stranded copper conductor FRLS insulated and unsheathed medium duty cable in colour code including contineous earth wire with cable of size 1.5 sqmm copper conductor flexible FRLS insulated drawn in existing concealed/surface Pvc/Steel conduit and including terminated into suitable module modular metal flush boxes of make :Elvira indoasian or equivalent in list of makes including white cover plate with frame as per relevant IS for mountinf swiches ,sockets,fan regulators etc complete all as specified and as directed for One light point controlled by one 6 Amps one way switch.. |
| 175 | All as per above item No-11 but One ceiling Fan, Exhaust Fan point controlled by one 6 Amps switch. |
| 176 | All as per above item No-11 but One bell/buzzer point controlled by one bell push button on independent. |
| 177 | All as per above item No-11 but One 3 pin socket out let 6 Amp point on independent board |
| 178 | All as per above item No-11 but One 3 Pin socket out let 6 Amp point on the same board with other switch. |
| 179 | All as per above item No-11 but with 2.5 Sqmm cable for 16 Amps switch sockets out let point on independent board including 2.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor. |
| 180 | S&F switch modular one way 06 Amp,1 module all as specified and directed. |
| 181 | S&F switch modular one way 16 Amp,1 module all as specified and directed. |
| 182 | S&F Moduler socket 6A-3 Pin 2 module 230v AC all as specified and direction. |
| 183 | S&F Modular socket 6A-3/16A-3 Pin 2 module 230v AC all as specified and direction. |
| 184 | S&F Modular bell push type one way 6 Amp 1 module all as specified and direction. |
| 185 | S&F modular type fan regulator 2 module all specified and direction |
| 186 | Supply and fixing of fan regulator socket type stepped type (electronic) polycarbonate for AC ceilling fan all as specified and direction. |
| 187 | Supply and fixing in replacement of Ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and as directed by Engr In charge |
| 188 | Supply and fixing in replacement of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed by Engr In charge |
| 189 | Supply and fixing of LED lamp suitable for B22 holder of capacity 7 Watt. |
| 190 | Supply and fixing in replacement of LED lights fitting 1x 18, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete complete all as specified and as directed by Engr In charge |
| 191 | Supply and fixing in replacement of LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engr In charge |
| 192 | Supply and fixing in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete complete all as specified and as directed by Engr In charge |
| 193 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete complete all as specified and as directed by Engr In charge |
| 194 | Supply and fixing of Vertical Distribution Board (VTP&N) 4 way double door suitable for MCCB 4 pole of cap upto 100 Amp as incomer and out going MCBs SP and should be IP 43 protected with Copper Bus Bars, Neutral Links, Earthing bar all as specified and directed. |
| 195 | Supply and fixing of MCCB four pole 100 Amp, 16 KA, 415 volts with adjustable thermal settings complete all as specified and as directed by Engr In charge |
| 196 | Supply & fix in replacement of Distribution Board MCB TPN 4 way double door suitable for MCB four pole as incomer and out going MCBs and should be IP 43 protected with Copper BusBars, Neutral Links, Earthing bar complete all as specified and as directed by Engr In charge |
| 197 | Supply & fix in replacement of sheet metal enclosure double door MCB distribution board. Single pole & neutral (SPN) 240 volts 12 way with IP-43 IK-09 protection double door complete all as specified and as directed by Engr In charge |
| 198 | All as per item No 39 but 8 Way double door complete all as specified and as directed by Engr In charge |
| 199 | All as per item No 39 but 4 Way double door complete all as specified and as directed by Engr In charge |
| 200 | Supply and fixing in replacement of MCB TPN 40 TO 100 AMP, 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning. |
| 201 | Supply and fixing MCB SPN 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 202 | Supply & fixing in replacement of MCB , 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. |
| 203 | Supply & fixing in replacement of rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm and 50 mm deep conplete. |
| 204 | Supply & fixing in replacement of rectangular block for mounting switches, socket, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 175 mm x 100mm and 50 mm deep conplete. |
| 205 | Supply & fixing in replacement of MCB SPN 40 to 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 206 | Supply & fixing in replacement of sub main wiring with single core cable 2 x 6 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade in rigid PVC conduit (Concealed) medium grade alongwith 1x6 Sq mm FRLS insulated unheathed stranded copper conductor cable as earth wire connected with main earth dolly including chiseling, cutting & making good to match with the existing surface complete all as specified and directed. |
| 207 | Supply & fixing in replacement of sub main wiring with single core cable 2 x 4 sq mm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade in rigid PVC conduit (Concealed) medium grade alongwith 1x4 Sq mm FRLS insulated unheathed stranded copper conductor cable as earth wire connected with main earth dolly including chiseling, cutting & making good to match with the existing surface complete all as specified and directed. |
| 208 | Taking down the defective ceiling fan 1200 mm sweep BLDC /Normal of any sweep and make after disconnecting electrically & mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:-(a) Servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete.(b) M& L for ceiling fan opening, cleaning, drying of ceiling fan including re-winding or BLDC Circuit plate the burnt/short circuited PCB or winding with same guage supper enameled copper wire to maintain speed at load. (c) M&L for preparing surface scrabing, finishing and Painting of ceiling fan by applying one coats of synthetic enamel paint after preparation of surface complete. |
| 209 | All as per ser Item No 51 above for exhaust fan/Wall mounting fan of size 300 MM sweep, any make, single phase, 230 volts, 50 HZ, AC complete. |
| 210 | Supply & fixing in replacement of ball bearing suitable for ceiling fans 1200 mm dia sweep. |
| 211 | Supply & fixing in replacement of ball bearing suitable for exhaust fans 300 mm dia sweep. |
| 212 | Supply & fixing in replacement of Capacitor 2.5 mfd for ceiling fans. |
| 213 | Supply & fixing in replacement of Capacitor 4 mfd for exhaust fans. |
| 214 | Supply & fixing in replacement of gun metal bush suitable for ceiling fans of 1200 mm sweep. |
| 215 | Supply & fixing in replacement of gun metal bush suitable for exhaust fans of 300 mm sweep. |
| 216 | Supply & fixing in replacement of three core flexible wire 1 Sqmm for connecting up ceiling fans , exhaust fans/wall mounting fan etc. |
| 217 | Supply & fixing in replacement of the wheel type rubber bush suitable size of fan with nut,bolt,washers,locking clip etc. suitable for hanging the ceiling fans |
| 218 | Supply & fixing in replacement of the mounting clamps with nut, bolt, washers, locking clip etc complete suitable fans for fixing at the top of down rod suitable for fixing the ceiling fan. |
| 219 | Supply & fix in replacement of ceiling fan down rod of MS pipe 15mm bore 1.2 Mtr length including cutting/threading making tide for fixing providing check nuts wachers and clamp with rubber bush etc complete. |
| 220 | Supply & fix in replacement of Casing Caping of size 20 mm, ISI marked complete all as specified. |
| 221 | M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 222 | Supply & fix in replacement of Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. |
| 223 | Taking down carefully storage type water heaters (Geyser) of any type and make of capacity 25 ltrs for servicing after disconnecting their electrical and water connections. De-scaling the inner container, heating element, base assembly using diluted hydrochloric acid and cleaning thoroughly. Filling the inner container with water and detecting leakage including brazing as required to stop the leakage, if any, reassembling the geysers after replacing the u/s spare parts, filling water and testing the geysers by applying pressure by means of hand/foot operated pump, to ensure leak proof. Refixing geyser in the same original position/location and making the electrical/water supply connections incl testing on completion complete all as specified and directed. (Note for sr item no 81 & 82 : (i) Items required to be replaced will be measured and paid separately under relevent items of the Schedule (ii) The rate for fixing of new spare parts are deemed to be included in quoted unit rate of above items) |
| 224 | Supply & fix in replacement of geyser elements 1.5 KW as per existing pattern fitted in the geyser all as specified and directed. |
| 225 | Supply & fix in replacement of Thermostat suitable for any make & type of Geyser 25/35/50 ltr capacity complete all as specified and directed. |
| 226 | Supply & fix in replacement of lamp for geysers red/green all as per site requirement and specified. |
| 227 | Supply & fix in replacement of PVC connection 15 mm size with PTMT nuts of length 450 mm as inlet for cold water including taking down the old unserviceable PVC connection pipe complete all as specified and as directed by EIC. |
| 228 | Supply & fixing in repairs PVC connection 15 mm size, spirally reinforced with stainless steel wire inside the pipe for outlet hot water pipe connection, with brass nuts at both ends of length 450 mm including taking down the old unserviceable PVC pipe all as specified and as directed by EIC. |
| 229 | Supply & fix in replacement of inner tank of 25 ltr capacity of tinned/ copper of approved make all as specified and directed as per site requirement. |
| 230 | Supply & fix in replacement of 3 core multi strand copper conductor PVC insulated cable 2.5 Sqmm1100 volts grade complete all as specified and directed by Engr-in-Charge. |
| 231 | Supply and fixing of modular metal flush box 2 module complete all as specified and directed. |
| 232 | Supply and fixing of modular metal flush box 3 module complete all as specified and directed. |
| 233 | Supply and fixing of modular metal flush box 6 module complete all as specified and directed. |
| 234 | Supply and fixing of modular metal flush box 8 module complete all as specified and directed. |
| 235 | Supply and fixing of modular White cover with frame plate 2 module complete all as specified and directed. |
| 236 | Supply and fixing of modular White cover with frame plate 3 module complete all as specified and directed. |
| 237 | Supply and fixing of modular White cover with frame plate 6 module complete all as specified and directed. |
| 238 | Supply and fixing of modular White cover with frame plate 8 module complete all as specified and directed. |
| 239 | Schedule of credit amount of Rs 3,55,973.00 to be deducted during AOC Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 28 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 35 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender