| Sl. No. | Item Description |
| 1 | S&F Pre- painted colour galvalume aluminium Zinc coating GI based corrugated tile profile steel sheet 0.50 mm thick of colour sepcified by the Engr-in-charge having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges fixed with self tapping screws etc complete all as directed including dismantling of existing sheet & neccessary scaffloding arrangement. Note :- Work shall be executed upto 10.5m height. |
| 2 | S&F 80 mm thick Heavy duty Factory made Precast plain / perforated RCC M-30 drain cover slab reinforcement with 10 mm dia TMT steel bars of Fe- 500 grade and providing black painted set and jointed in cement mortar 1:4 complete including removal of damaged drain cover from the IMA Premises complete all as specified and directed. |
| 3 | S & F factory made Prepainted/powder coated 2 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 with arrangement of fixing PVC pipe of 200 mm dia etc complete all as directed including dismantling of existing sheet & neccessary scaffloding arrangement. Note :- Work shall be executed upto 10.5m height. |
| 4 | M&L for PVC (SWR) pipe 200 mm bore single socketed, in any length with rubber ring joints,fixed to walls/valley gutter etc including dismantling of damage pipe with all fittings complete all as specified and directed. |
| 5 | S&F PVC (SWR) 200 mm bore bends in any radius complete all as specified and directed. |
| 6 | S&F stack clamps made out of 25mm X 5 mm flat iron and 16mm dia round iron stays, for fixing 200 mm bore pipe including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed |
| 7 | Dismantling wrought iron or mild steel work of any description not otherwise provided for support of valley gutter/roof etc complete all as specified and directed. |
| 8 | S&F mild steel framed work of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles to support valley gutter, as necessary, gusset plates, riveting, hooks conforming to Fe.290.Gde-E-165 etc including neccessary scaffloding arrangement complete all as specified and directed. Note :- Work shall be executed upto 10.5m height. |
| 9 | M&L for forming construction joint 30 mm deep x 10 mm wide filled with sealing compound Grade A, including removing old damaged filling materials from joints of play courts, including cleaning, site clearance complete all as specified and directed. |
| 10 | M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth and applying one coat of synthetic enamel paint with approved shade complete all as specified and directed upto 10.5 m height. Note :- Painting shall be carried out on old angle iron post/truss of play courts shed etc. |
| 11 | M&L for Preparation of old painted steel surfaces of any description, n.exc 10 cm in width or girth and applying one coat of synthetic enamel paint with approved shade complete all as specified and directed upto 10.5 m height. Note :- Painting shall be carried out on old angle iron post/truss of play courts shed etc. |
| 12 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as directed and specified upto 10.5 m height. |
| 13 | M & L for Preparation of old plastered/unplastered surfaces of wall and applying one coat of weather proof exterior emulsion paint (Apex paint of Asian Paint / Weather proof of berger) or equivalent of approved make on walls complete all as directed upto 10.5 m height. |
| 14 | M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates as in hard standing 100 mm thick laid in panels and finished even and smooth without using extra cement using upto full depth Preformed Polymer based filler dividing strip, 3 mm thick filled with sealing compound complete including demolotion of existing flooring all as specified and directed. |
| 15 | M&L for non-skid premium quality (1st quality) (Group B1 a) water absorption E<0.008 % coloured exterior grade tiles, any pattern of size 300 x 300 mm/400x 400 mm 10-12 mm thick set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade as in floor/steps/riser over and incl 15 mm thick screed bed/rendering in CM 1:4 complete all as specified and as directed. |
| 16 | M&L for 75 mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection or paving in similar places and finishing the surface even & smooth with out using extra cement including making joints 12mm wide to the full depth of PCC at every 3 meter and every change of direction and filling the same with mixture of bitumen & sand in ratio (1:1) by weight including necessary form work etc and including demolition of existing old cement concrete, complete all as specified and directed. |
| 17 | Dismantling of existing depressed/sunk interlocking paver block of any thickness and shape, supply & spreading a layer of sand of required thickness and refixing the block in matching level of near by surface complete all as specified & directed. |
| 18 | M&L for Rubberised polished precast coloured cement concrete Interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade complete with & including 25mm thick sand cushioning layer including dismantling of existing damaged flooring etc complete, all as specified and directed. |
| 19 | M&L for PCC 1:4:8 type D-2, using 40 mm graded stone agg as in foundation, filling, mass concrete and sub base of floor including demolition of existing old concrete complete all as specified and directed. |
| 20 | M&L for Providing cement concrete type B1, 1:2:4 (20mm graded stone aggregate) in kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 21 | M&L for Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6.00m mean radius built in cement mortar(1:6) including demolition of brick work/stone masonry built in cement mortar complete all as specified and directed. |
| 22 | M&L, for Rendering 12 mm thick in cement mortar 1:4 on new brick or concrete surfaces with mixing WPC as per manufacturers instructions, surfaces finished even and smooth without using extra cement complete all as specified and directed. ( Note :- WPC shall be paid separately if directed) |
| 23 | M&L for Rendering 12 mm thick on brick or concrete surface with WPC as per manufacturers instructions, surfaces finished even and smooth without using extra cement complete including taking down cement plaster on brick or stone walling built in CM 1:4 including raking out joints hacking for key scrubbing down with water all as specified and directed. ( Note :- WPC shall be paid separately if directed) |
| 24 | Supply only liquid water proofing compound complete all as specified & directed. |
| 25 | M&L for Preparation of new plastered/unplastered surfaces of wall and applying two coats of weather proof exterior emulsion paint (Apex paint of Asian Paint / Weather proof of berger) including one coat of exterior primer on walls complete all as specified and directed. |
| 26 | Material and labour for steel tubular swaged pole 11 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 55 including painting with anti corrosive paint internally complete and externally complete with two coat of synthetic enamel aluminium paint over a coat of red oxide primer and preparation of surface including marking of pole Nos with black paint complete all as specified and as directed. |
| 27 | Material and labour for plain cement concrete 1:4:8, type D2 using 40 mm graded stone aggregate for foundation filling of poles as mass concrete complete all as specified and directed. |
| 28 | Material and labour for PCC 1:2:4, type B-1 using 20 mm graded crushed stone aggregate as in coping of poles/stays etc complete all as specified and directed. |
| 29 | Material and labour for plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate for foundation filling of poles as mass concrete complete all as specified and directed. |
| 30 | Supply and fix shock proof and rust proof pole mounted junction box (SMC) of size 140mm x 140mm x 90mm for security lighting system complete with all accessories and including MCB SP 6 Amp, 100 Amp rated heavy aluminium bus bar mounting on saddle, 2 terminals, pole clamp with nut bolts etc with necessary mounting arrangement in the junction box with pole all as specifed and directed.Make: Sintex Industries Ltd/ Supreme Industries/ Naithani Plastic Moulding Works. |
| 31 | Supply and fix LED street light fitting 90 watt energy saving and enviromental friendly long life made up of pressure die cast aluminium housing with toughened glass and high power LED with secondary optics as lightnig source embedded PC cover having top opening seprate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV built in surge protection device suitable for pole dia 54 mm (max) not less than 120 LPW including taking down existing fitting of any type and in any position complete all as directed. |
| 32 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 4 core complete all as directed. |
| 33 | Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth in soft/loose soil for laying cable/ taking out under ground cable, GI pipes and bricks laid under cable and getting out in soft/loose soil complete all as directed. |
| 34 | Returning, filling in trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick in soft/loose soil after cables/pipes are laid and tested complete all as directed. |
| 35 | Removing the excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as directed. |
| 36 | S&F double wall corrugated high density polyethylene (HDPE) pipe for laying of electric cable of size 63 mm outer diameter and 51 mm inner diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. |
| 37 | Material and labour for earthing with galvanised steel earth plate electrode 60cmX60cmX 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized earth lead wire 4 mm dia by means of nuts,bolts,check nuts & washers of galvanized iron or steel,protected by 15mm bore light grade galvanised iron pipe and connected to main switch board,including all necessary excavation & earth work in hard dense soill including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternate layers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 6mm MS rod for handle and necessary testing complete all as shown in electrical plate No 3 of SSR part-I all as specified and directed. |
| 38 | Material and Labour for galvanised steel tubes light grade 40 mm bore for bracket of street/security light length 1.20RM including welding, bend to shape and fixed with 2 SET 40X3MM FI clamp including nuts and bolts complete all as directed. |
| 39 | Material and Labour for PVC insulated copper conductor flexible cable 1100 Volts grade Cross section area of size 1.5 Sq mm 3 Core laid in trenches/pole complete all as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender