Public Administrative Department Local Bodies Closing in 10 days TDR #57524638

Tender For Annual Maintenance Contract For Transformer, Vcb, L.T. Panel And D.G. Set In Multi Storey Building, Omicron-1A, Greater Noida.

Issued by Local Bodies · Gautam Buddha Nagar, Uttar Pradesh
Tender Value
2.26 Crore
Estimated cost
Bid Submission
25 Sep 2026
10 days left
EMD
4.53 Lakhs
Bank guarantee accepted
Document Fee
4040
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gautam Buddha Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Annual Maintenance Contract For Transformer, Vcb, L.T. Panel And D.G. Set In Multi Storey Building, Omicron-1A, Greater Noida.

BOQ

Name of Work:- Annual Maintenance contract for Transformer, VCB, L.T. Panel and D.G. Set in Multi Storey Building, Omicron-1A, Greater Noida.
Sl. No. Item Description
1Maintenance of Indoor floor mounted totally enclosed including all loading - unloading, testing and comisioning caringfrom site to workshop & back to site etc. coimpartmentalized, extendable type PCC/ PMCC/MCC Cubicle Panel Board having 36 MVA, 50 kA breaking capacity of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure Chemically treated with seven tank process before painting for surface treatment and powder coated, with suitable electrolytic grade high conductivity PVC sleeved aluminium (E91-E) busbars shall be sized for maximum 0.8 A/mm2 current density, extensible type. complete in all respect asper direction of E/I. Make L&T, ABB, Schneider. GNIDA Approved Rate
2Air Circuit Breaker (ACB)
3Supply and Replacement Air circuit Breaker (3200 amp)
4Supply and Replacement Air circuit Breaker (1600 amp)
5Supply and Replacement Air circuit Breaker (1000/1250 amp)
6Supply and Replacement Air circuit Breaker (830 amp)
7Supply and Replacement 530 amp
8Supply and Replacement 400 amp
9Supply and Replacement 315 amp
10Supply and Replacement 160 amp
11Supply and Replacement 125 amp
12Supply and Replacement 100 amp
13Supply and Replacement 63 amp
14Maintenance of 33 Kv & 11 Kv 1000 MVA, 400 A, Indoor, drawout type Three HT Vaccum Circuit Breaker Panel (1 Incomer + 2 outgoing) with CT and PT including all loading - unloading, testing and commisioning carrying from site to workshop & back to site etc. PT appropriate rating for metering and protection along with required Indicating lamps, protection relay and Indicating meters, etc. complete in all respects as per IS, Specification including loading and unloading. complete in all respect as per direction of E/I. GNIDA Approved Rate
15HT Indoor Switch gear Panel - 11 KV
16Supply and Replacement CT/PT
17Supply and Replacement HT Fuse &MCB
18Supply and Replacement Cable joint kit
19Supply and Replacement Protective relay
20Preventive Maintenance (quarterly & as when required)
21S&F of 200 Amp. Four pole mouled case type on load change over switch with enclosure includind the cost of labour, T & P and material required for proper completion of the work as per direction and satisfaction of Engineer in charge. UPPWD-2018/379A
22Maintenance of diesel generator with engine, alternator & DG Controller Set, including all loading - unloading, testing and commissioning caring from site to workshop & back to site etc. complete in all respect as per direction of E/I. GNIDA Approved Rate
231000 KVA (Cummins) ( for 02 Nos. DG Set)
24Filter Lubricating Oil
25Supply and Replacement Element Air Cleaner
26Supply and Replacement Belt
27Fuel Filter
28Supply and Replacement Gas Kit Cylinder Head
29Supply and Replacement Battery pulse lite
30Indicator Restriction
31Supply and Replacement Electronic Accessories
32Preventive Maintenance (quarterly & as when required)
33Separator Fuel Water
34Maintenance of 33000 / 433 Volts, 2000 KVA,ONAN, Dyn-11, continuous duty type step-down transformer with on load tap change including all loading unloading, testing and commissioning cashing from site to workshop & back to site etc, with other standard fittings, accessories and along with required foundation for transformer including loading and unloading. complete in all respect as per direction uf E/I. GNIDA APPROVED RATE
352000 KVA Distribution Transformer (VOITAMP)
36Dehydration
37Oil Filteration
38S/R Protective Relay
39S/R Bus- Bar (3200 amp.)
40S/R Silica Gel Breather
41Preventive Maintenance (quarterly & as when required.)
42Supply & fixing of 8mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 135 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. UPPWD-2018/643
43Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 30Watt. to 40 Watt. Confirming to IP 66 protection complete in all respect. CAT-AA UPPWD-2018/1420
44Supply and fixing of LED Tube Light with battensuitable for up to 1 X 22 watt LED tube light fittingincluding tube on Surface complete in all respect. CAT-AA UPPWD-2018/1413
45Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighterhaving Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-AA UPPWD-2018/1402
46Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. UPPWD-2018/501
476 sq. mm 4 core
4810 sq. mm 4 core
4916 sq. mm 4 core
50150 sq. mm 3-1/2 core
51240 sq. mm 3-1/2 core
52300 sq. mm 3-1/2 core
53Supply, delivery, laying, testing &commissioning of 33KV (E) XLPE cable having compact circular stranded aluminium conductor The conductor should have screening of extruded semi conducting compound, cross linked polythylane (XLPE), insulation screening of the extruded semin conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to It IS: 7098 (Part-amendments) for following mentioned sizes. should be operational at 33 KV, 50 Hz. AC system in ground at a depth of 1200 mm belowW ground level overa cushion of 75 mm thick sand alround and protected with bricks on sides and at the top surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/| with Complete all respect. The price are inclusive of all earth work such as digging, back filing, supply& spreading of good earth all around the cable, supply 8& providing cable identification markers. The installation should be complete in all respects and as per requirement of the job as per direction of Engineer-in charge. GNIDA-SOR-2024/03
5433 KV XLPE Cable 3C X 240 Sqmm
55Supply, Installation, Testing & Commissioning of Straight through cable jointing kit for L.T. PVC armored cable jointing. . Complete in all respect as required for proper completion of work As per direction of Engineer-in-charge. GNIDA-SOR-2024/07
563.5/4C x 16Sq.mm.
573.5/4C x 150Sq.mm.
583.5/4Cx 240Sq.mm.
593.5/4Cx 300Sq.mm
60Supply, Installation, Testing & Commissioning of Straight through cable jointing kit for 33KV XLPE armoured cable jointing. Complete in all respects as required for proper completion of work as per direction of E-i/c. GNIDA-SOR-2024/08
613C X 300 Sq.mm
62Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. UPPWD-2018/504
6310 sqmm
6416 Sqmm
6570 Sqmm
66150 Sqmm
67240 Sqmm
68300 Sqmm
69Operation of HT Panel, 33 KV VCB/Transformer, isolator panel, Main LT Panel Sub panel, internal lighting & external lighting panel, Diesel Generator. (FTS-144730)1. Operation of DG Set during power failure.2. Change over during power failure.3. Taking of all running load reading every 2 hours4. Maintain of DG running record.
70Work of scope of Transformer: Visual inspection of transformer1. Checking of relays of transformer2. Checking of cooling systems3. Checking of oil level.
71Scope of work of H.T. / L.T. panel:Visual inspection of breaker1. Through cleaning of breaker2. Lubrication of moving parts of drive mechanism.3. Lubrication of closing & tripping mechanism4. Checking of Gear box assembly5. Checking of Test service auxiliary switch operation6. Checking of tripping mechanism operation7. Checking of breaker auxiliary switch operation.8. Sprin'g charging limit switch operation.9. Checking of front drive key operation in test & service position.10. Checking of trip coil resistance11. Checking of closing coil resistance.
72Operation of light 1. Substation O/M2. Street light O/M3. Technical Supervisor - 01 No.4. D.G. Operator/ Electrician - 06 No.5. Helper - 01 No.
73Grand Total (AMC period 03 Year)
74Labour Cess and GST will be paid extra as per govt. orders Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57524638
AUTHORITY Local Bodies
TENDER VALUE 2.26 Crore
LAST DATE 25-09-2026
Authority
Authority Name Greater Noida Industrial Development Authority
Work Description Tender for Annual Maintenance Contract For Transformer, Vcb, L.T. Panel And D.G. Set In Multi Storey Building, Omicron-1A, Greater Noida.
Basic Detail
Tender No SM/(E-TENDER CELL)/2026/811 DATED-10.09.2026
Bidding Type Tender
Location
City Gautam Buddha Nagar
State Uttar Pradesh
Key Dates
Publish Date 15 Sep 2026
Submission Date 25 Sep 2026
Open Date 28 Sep 2026
Finance
Tender Value 2.26 Crore
Tender Fee 4040
EMD 4.53 Lakhs
Exemption Not Available
Document List
7a9f33ed-c144-4cb3-aee2-39ea7c96a2eb.html
BOQ_2231160.xls
PreQ_Annu_Maint_Cont_Tran_1.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 15, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Sep 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

7a9f33ed-c144-4cb3-aee2-39ea7c96a2eb.html

xls

BOQ_2231160.xls

pdf

PreQ_Annu_Maint_Cont_Tran_1.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender