Tender For Annual Maintenance Contract For Transformer, Vcb, L.T. Panel And D.G. Set In Multi Storey Building, Omicron-1A, Greater Noida.
Tender Value
2.26 Crore
Estimated cost
Bid Submission
25 Sep 2026
10 days left
EMD
4.53 Lakhs
Bank guarantee accepted
Document Fee
4040
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gautam Buddha Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Maintenance Contract For Transformer, Vcb, L.T. Panel And D.G. Set In Multi Storey Building, Omicron-1A, Greater Noida.
BOQ
| Sl. No. | Item Description |
| 1 | Maintenance of Indoor floor mounted totally enclosed including all loading - unloading, testing and comisioning caringfrom site to workshop & back to site etc. coimpartmentalized, extendable type PCC/ PMCC/MCC Cubicle Panel Board having 36 MVA, 50 kA breaking capacity of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure Chemically treated with seven tank process before painting for surface treatment and powder coated, with suitable electrolytic grade high conductivity PVC sleeved aluminium (E91-E) busbars shall be sized for maximum 0.8 A/mm2 current density, extensible type. complete in all respect asper direction of E/I. Make L&T, ABB, Schneider. GNIDA Approved Rate |
| 2 | Air Circuit Breaker (ACB) |
| 3 | Supply and Replacement Air circuit Breaker (3200 amp) |
| 4 | Supply and Replacement Air circuit Breaker (1600 amp) |
| 5 | Supply and Replacement Air circuit Breaker (1000/1250 amp) |
| 6 | Supply and Replacement Air circuit Breaker (830 amp) |
| 7 | Supply and Replacement 530 amp |
| 8 | Supply and Replacement 400 amp |
| 9 | Supply and Replacement 315 amp |
| 10 | Supply and Replacement 160 amp |
| 11 | Supply and Replacement 125 amp |
| 12 | Supply and Replacement 100 amp |
| 13 | Supply and Replacement 63 amp |
| 14 | Maintenance of 33 Kv & 11 Kv 1000 MVA, 400 A, Indoor, drawout type Three HT Vaccum Circuit Breaker Panel (1 Incomer + 2 outgoing) with CT and PT including all loading - unloading, testing and commisioning carrying from site to workshop & back to site etc. PT appropriate rating for metering and protection along with required Indicating lamps, protection relay and Indicating meters, etc. complete in all respects as per IS, Specification including loading and unloading. complete in all respect as per direction of E/I. GNIDA Approved Rate |
| 15 | HT Indoor Switch gear Panel - 11 KV |
| 16 | Supply and Replacement CT/PT |
| 17 | Supply and Replacement HT Fuse &MCB |
| 18 | Supply and Replacement Cable joint kit |
| 19 | Supply and Replacement Protective relay |
| 20 | Preventive Maintenance (quarterly & as when required) |
| 21 | S&F of 200 Amp. Four pole mouled case type on load change over switch with enclosure includind the cost of labour, T & P and material required for proper completion of the work as per direction and satisfaction of Engineer in charge. UPPWD-2018/379A |
| 22 | Maintenance of diesel generator with engine, alternator & DG Controller Set, including all loading - unloading, testing and commissioning caring from site to workshop & back to site etc. complete in all respect as per direction of E/I. GNIDA Approved Rate |
| 23 | 1000 KVA (Cummins) ( for 02 Nos. DG Set) |
| 24 | Filter Lubricating Oil |
| 25 | Supply and Replacement Element Air Cleaner |
| 26 | Supply and Replacement Belt |
| 27 | Fuel Filter |
| 28 | Supply and Replacement Gas Kit Cylinder Head |
| 29 | Supply and Replacement Battery pulse lite |
| 30 | Indicator Restriction |
| 31 | Supply and Replacement Electronic Accessories |
| 32 | Preventive Maintenance (quarterly & as when required) |
| 33 | Separator Fuel Water |
| 34 | Maintenance of 33000 / 433 Volts, 2000 KVA,ONAN, Dyn-11, continuous duty type step-down transformer with on load tap change including all loading unloading, testing and commissioning cashing from site to workshop & back to site etc, with other standard fittings, accessories and along with required foundation for transformer including loading and unloading. complete in all respect as per direction uf E/I. GNIDA APPROVED RATE |
| 35 | 2000 KVA Distribution Transformer (VOITAMP) |
| 36 | Dehydration |
| 37 | Oil Filteration |
| 38 | S/R Protective Relay |
| 39 | S/R Bus- Bar (3200 amp.) |
| 40 | S/R Silica Gel Breather |
| 41 | Preventive Maintenance (quarterly & as when required.) |
| 42 | Supply & fixing of 8mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 135 mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. UPPWD-2018/643 |
| 43 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 30Watt. to 40 Watt. Confirming to IP 66 protection complete in all respect. CAT-AA UPPWD-2018/1420 |
| 44 | Supply and fixing of LED Tube Light with battensuitable for up to 1 X 22 watt LED tube light fittingincluding tube on Surface complete in all respect. CAT-AA UPPWD-2018/1413 |
| 45 | Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighterhaving Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-AA UPPWD-2018/1402 |
| 46 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. UPPWD-2018/501 |
| 47 | 6 sq. mm 4 core |
| 48 | 10 sq. mm 4 core |
| 49 | 16 sq. mm 4 core |
| 50 | 150 sq. mm 3-1/2 core |
| 51 | 240 sq. mm 3-1/2 core |
| 52 | 300 sq. mm 3-1/2 core |
| 53 | Supply, delivery, laying, testing &commissioning of 33KV (E) XLPE cable having compact circular stranded aluminium conductor The conductor should have screening of extruded semi conducting compound, cross linked polythylane (XLPE), insulation screening of the extruded semin conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to It IS: 7098 (Part-amendments) for following mentioned sizes. should be operational at 33 KV, 50 Hz. AC system in ground at a depth of 1200 mm belowW ground level overa cushion of 75 mm thick sand alround and protected with bricks on sides and at the top surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/| with Complete all respect. The price are inclusive of all earth work such as digging, back filing, supply& spreading of good earth all around the cable, supply 8& providing cable identification markers. The installation should be complete in all respects and as per requirement of the job as per direction of Engineer-in charge. GNIDA-SOR-2024/03 |
| 54 | 33 KV XLPE Cable 3C X 240 Sqmm |
| 55 | Supply, Installation, Testing & Commissioning of Straight through cable jointing kit for L.T. PVC armored cable jointing. . Complete in all respect as required for proper completion of work As per direction of Engineer-in-charge. GNIDA-SOR-2024/07 |
| 56 | 3.5/4C x 16Sq.mm. |
| 57 | 3.5/4C x 150Sq.mm. |
| 58 | 3.5/4Cx 240Sq.mm. |
| 59 | 3.5/4Cx 300Sq.mm |
| 60 | Supply, Installation, Testing & Commissioning of Straight through cable jointing kit for 33KV XLPE armoured cable jointing. Complete in all respects as required for proper completion of work as per direction of E-i/c. GNIDA-SOR-2024/08 |
| 61 | 3C X 300 Sq.mm |
| 62 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. UPPWD-2018/504 |
| 63 | 10 sqmm |
| 64 | 16 Sqmm |
| 65 | 70 Sqmm |
| 66 | 150 Sqmm |
| 67 | 240 Sqmm |
| 68 | 300 Sqmm |
| 69 | Operation of HT Panel, 33 KV VCB/Transformer, isolator panel, Main LT Panel Sub panel, internal lighting & external lighting panel, Diesel Generator. (FTS-144730)1. Operation of DG Set during power failure.2. Change over during power failure.3. Taking of all running load reading every 2 hours4. Maintain of DG running record. |
| 70 | Work of scope of Transformer: Visual inspection of transformer1. Checking of relays of transformer2. Checking of cooling systems3. Checking of oil level. |
| 71 | Scope of work of H.T. / L.T. panel:Visual inspection of breaker1. Through cleaning of breaker2. Lubrication of moving parts of drive mechanism.3. Lubrication of closing & tripping mechanism4. Checking of Gear box assembly5. Checking of Test service auxiliary switch operation6. Checking of tripping mechanism operation7. Checking of breaker auxiliary switch operation.8. Sprin'g charging limit switch operation.9. Checking of front drive key operation in test & service position.10. Checking of trip coil resistance11. Checking of closing coil resistance. |
| 72 | Operation of light 1. Substation O/M2. Street light O/M3. Technical Supervisor - 01 No.4. D.G. Operator/ Electrician - 06 No.5. Helper - 01 No. |
| 73 | Grand Total (AMC period 03 Year) |
| 74 | Labour Cess and GST will be paid extra as per govt. orders Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 15, 2026
11:30 IST
Tender Published
Tender notice published.
TodaySep 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓