Tender For Providing Led High Mast On Chhapraula Rob & Link Road Nh-91, Greater Noida.
Tender Value
57 Lakhs
Estimated cost
Bid Submission
25 Sep 2026
10 days left
EMD
1.15 Lakhs
Bank guarantee accepted
Document Fee
1760
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gautam Buddha Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Led High Mast On Chhapraula Rob & Link Road Nh-91, Greater Noida.
BOQ
| Sl. No. | Item Description |
| 1 | Supply & fixing of 30 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 4 mm. Top dia minium 150 mm, Bottom dia 500 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 8 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. UPPWD 2018 / Sl. No. 655 |
| 2 | Supply & fixing of 16 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 360 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect. UPPWD 2018 / Sl. No. 655 |
| 3 | Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.20.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as_ per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K /5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 Im/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS’ shall be submitted. Shape size and CCT shall be as approved by _ Engineer-in-Charge as _ per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).DSR (E&M)-2025 / SL. No. 8.17.5 |
| 4 | 200 watt |
| 5 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.UPPWD 2018 / Sl. No. 501 |
| 6 | 50 sq. mm 3.5 core (l) |
| 7 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer Incharge. UPPWD 2018 / Sl. No. 503 |
| 8 | 50 sq. mm 3.5 core (l) |
| 9 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. UPPWD 2018 / Sl. No. 504 |
| 10 | 25 sq. mm |
| 11 | 50 sq. mm |
| 12 | Supply and burying of Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm _ thick including accessories, and _ providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.DSR (E&M)-2025 / SL. No. 5.4 |
| 13 | Supply & Laying 90 mm dia. H.D.P.E. pipe for drawing of power cable across the road by drilling of 110 mm dia. at 1 mtr. below the road level thereby doing the work of providing H.D.P.E. pipe by manual Trenchless method PE-63/PN-8. Complete in all respect as per direction of E-I/c.GNIDA SOR 2025 / SL. No. 23 |
| 14 | S/F of G.I. Pipe 100 mm dia 'B' Class ZINDAL/ TATA Make including required required material T & P etc. complete in all respect as per direction of the Engineer - in Charge at SITESOR 37 / FTS No. 128181 |
| 15 | Supplying and drawing 3x2.5sq.mm of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.DSR (E&M)-2025 / SL. No. 1.17.12 |
| 16 | Providing and fixing 25 mm X 5 mm Gl. strip on surface or in recess for connections etc. as required.DSR (E&M)-2025 / SL. No. 5.15 |
| 17 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. UPPWD 2018 / Sl. No. 807 F (ii) |
| 18 | Supply & erection Section Double pole structure on ST pole 410 SP-62 with 1/6 over length of poles grouted with cement concrete in 1:3:6 (one cement: 3 coarse sand :6 Stone ballast) including plingthing of pole 30 cm above grade level, plastering of plinth including excavation & back filling etc. The double pole structure consist of 100X50X6mm 2.50 mtr. & 75X40X6mm 2.50 mtr. M.S. channel and bracings with M.S. clamp packing piece Nuts Bolts etc. The rate includes all materials labour T&P etc. Required for proper completion of work as per direction of E/I.GNIDA SOR 2025 / SL. No. 28 |
| 19 | Supply & Fixing of Cross arm made of 100X50X6 mm M.S. channel 2.5 mtr. long on poles with packing, piece, M.S. clamp, Nut bolts etc, complete in all respect, as per direction of E-I/C.GNIDA SOR 2025 / SL. No. 33 |
| 20 | Supply, installation, testing and commissioning of following capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade, including bus trunking arrangement on LV side including |
| 21 | supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), 1S: 1180 and duly ISI Marked and as per CPWD specifications complete in all respects etc as required at site . |
| 22 | The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 35 dg.C for oil and 40 dg. C up to 200 KVA and 40 dg.C for oil and 45 dg. C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shallbe used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 deg C, b) |
| 23 | Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMAstandard. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminum/ stainless steel material securely fixed on the outer body, easily accessible, as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked. |
| 24 | Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c)Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (%4\\" nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (174\\" nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); |) |
| 25 | Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); 0) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side — 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; |
| 26 | v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. DSR (E&M)-2025 Vol - II / SL. No. 3.12.1 |
| 27 | 63 KVA |
| 28 | Supply & Fixing of 0.3mtr. long top channel for pin made of 100X50X6 mm M.S. channel with M.S. clamp packing box nut bolt etc. complete in all respect, as per direction of E-I/C.GNIDA SOR 2025 / SL. No. 33 |
| 29 | Supply & Fixing of 11 KV Polymeric pin insulator with pin on poles or anywhere specified including bolts to fasten on pole cap/cross arm with the poles. (Jaishree, BHEL,RR, Hindustan, Yamuna, AD make) Complete in all respect, as per the direction of E-I/c.GNIDA SOR 2025 / SL. No. 67 |
| 30 | Supply & Fixing of 11 KV Polymeric Disc with Gun Fittings on cross arms/clamps fixed on poles including all Nut, blots & washer etc. (Jaishree, BHEL, RR, Hindustan, Yamuna, AD, make) Complete in all respect, as per the direction of E-I/c.GNIDA SOR 2025 / SL. No. 68 |
| 31 | Supply & fixing of 11 KV TPMO set of 'Relco' make or equivalent with Insulators and other accessories required for proper completion of work, as per direction of E-I/C.GNIDA SOR 2025 / SL. No. 45 |
| 32 | Supply & fixing of 11 KV Drop-out type fuse set channel type of 'Relco' or equivalent make with Insulators and other accessories required for proper completion of work, as per direction of E-I/C.GNIDA SOR 2025 / SL. No. 46 |
| 33 | Supply and laying of 3 core standered aluminium conductor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098 (Part-II with latest amendments) II KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps etc.UPPWD 2018 / Sl. No. 506 (f) |
| 34 | 120 sq, mm 3 core |
| 35 | Supply, Installation, Testing & Commissioning of outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of grade as required. complete in all respect as required for proper completion of work as per direction of Engineer-in-charge. (Make Raychem/C.C.I./Frontec)DSR (E&M)-2025 / SL. No. 23.5.2 |
| 36 | 3C X 120 Sq.mm |
| 37 | Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect. UPPWD 2018 / Sl. No. 634 |
| 38 | Labour Cess and GST will be paid extra as per govt. orders Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 15, 2026
11:30 IST
Tender Published
Tender notice published.
TodaySep 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender