Drinking Water Supply and Sanitation Government Departments Closing in 1 days TDR #57521868

Tender For Construction Of Open Well, Glsr And Providing ,Laying , Jointing Of Pipeline With Functional House Hold Tap Connection Work Under Dmft 17Th Gc With 1 Year Defeat Liability Period At Hab- Ambaver, Kaniya Bhatda, Jhalo Ka Bhilwara, Thala Pat

Issued by Government Departments · Rajsamand, Rajasthan
Tender Value
86.44 Lakhs
Estimated cost
Bid Submission
26 Sep 2026
1 days left
EMD
1.72 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rajsamand → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Open Well, Glsr And Providing ,Laying , Jointing Of Pipeline With Functional House Hold Tap Connection Work Under Dmft 17Th Gc With 1 Year Defeat Liability Period At Hab- Ambaver, Kaniya Bhatda, Jhalo Ka Bhilwara, Thala Patiya Gp-Banokada Block- Kumbhalgarh, District- Rajsamand.

BOQ

Name of Work:- Construction of Open well, GLSR and Providing ,Laying , Jointing of Pipeline with FHTCs work Under DMFT 17th GC with 1 year Defeat Liability Period at Hab- Ambaver, Kaniya Bhatda, Jhalo Ka bhilwara, Thala Patiya GP-Banokada Block- Kumbhalgarh, District- Rajsamand.
Sl. No. Item Description
1Construction of open well 4.0 m dia and 20 m depth .
2Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in lead of 50 mtr. All kinds of soil.
3From 0m to 2.5 m BGL
4Earth work in excavation in foundation trenches or drains including dressing of sides and ramnming of bottoms lift up to 1.5 mtr including traking out the excavated soil and depositing and refilling of jhiri with watering and ramming and deposals of surplus excavted soil as directed with a lead in a 50 mtr including stacking of useful material if available.
5Ordinary rock
6From 2.5m to 5.0 m BGL
7Hard rock (requiring blasting) useful material 30 %
8Fromm 5.0m to 6.0 m BGL
9From 6.0 to 20.0 m BGL
10Add extra over item No 2.1 and 2.2 for every additional; lift of 1.5 m or part thereof.
11In All Kind of soil
12From 1.5 to 2.5 m BGL
13In ordinary rock and hard rock
14From 2.5 to 3.0 m BGL
15From 3.0to 4.5 m BGL
16From 4.5 to 6.0 m BGL
17From 6.0 to 7.5 m BGL
18From 7.5m to 9.0 m BGL
19From 9.0 to 10.5 m BGL
20From 10.5 to 12.0 m BGL
21From 12.0 to 13.5 m BGL
22From 13.5 to 15.0 m BGL
23From 15.0 to 16.5 m BGL
24From 16.5 to 18.0 m BGL
25From 18.0 to 19.5 m BGL
26From 19.5 to 20.0 m BGL
27Add extra over item no 2.1 and 2.2 for excavation in saturated soil where pumping or bailing out of water is required including shorting strutting where required and dewatering.(Respective applicable rates)
28From 6.0 to 20.0 m BWL
29Centering & shuttering with ply wood or steel sheets including strutting , propping, barcing both ways with steel props and removal of form work up to floor Five level for:Walls (any thickness) including attached pilasters, buttresses, plinth and string course.
30Add extra for shuttering in circular work (in respective centering and shuttering items)Sqm 20%
31Providing and fabricating reinforcement for RCC work including straightening, cutting, bending, placing in position in binding (including cost of binding wire ) all complete up to floor five level
32Thermo mechanically treated bars (conforming to relevant IS:1786.)
33Providing and layiny in position specified grade of cement concrete for RCC Structure elements upto floor Five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement ; 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement for :
34Walls (any thickness) including attached pilasters buttresses, plinth and string courses fillets columns pillars pears abutments posts struts etc.
35M20 grade nominal mix .
36Structural steel work in single section fixed with connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr. height
37In flates, tees, angles & Channals
38In R.S. Joists
39Random rubble stone masonary for foundation and plinth in cement sand mortar above 30 cm thick wall in:
40Cement Mortar 1:4 ( 1 cement : 4 Sand )
41Random Rubble stone masonary for superstructure above plinth level one storey height above 30 cm. thick walls in :
42Cement mortar 1:4 ( 1 Cement : 4 Sand )
43Plaster on new surface on wall in cement sand mortar 1:3 including raking of joints etc. complete fine finish:
4420 mm thick
45Finishing wall with water proofing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding
46New Work ( Three or more coats)
47Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :12.46.1 Two or more coats on new work
48Labour charges for horizontal boring 100 mm dia in open well in rocky strata with all types of rock cutting & drilling tools etc. including all T&P required forjob including dewatering arrangement.
49Construction of tube well having dia 200mm and 200 meter depth .
50Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe.
51Nominal bore 200 mm dia.
52Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr.
53Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amendedup to date of following sizes
54200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)
55Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.
56200 mm dia
57Construction of RCC GLSR 50KL Cap.
58Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: -
59a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work.c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type).
60i) Providing and fixing MS ladder from ground to top slab with safety cage. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipe of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
61Rates for RCC GROUND LEVEL SERVICE RESERVOIR SEISMIC ZONE-II & III and SBC18T/sqm
6250 KL capacity
63Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
64100 mm
65Providing, lowering, laying, aligning, fixing in position in pipe line, manually operated DI D/F Resilient (Soft) seated Gate Valve EPDM Coated DI wedge 100% vaccum light, flange Dimention IS: 14846, of approved make PN 1.6 class and CI Tail Piece- 2 Nos. (IS: 5531- 1988- amended up to date- For CI Plane Ended Specials) of same size of following dia complete including all material like Instren Rubber Sheet of thickness- 6.00 mm (ISI Mark)- For Rubber Sheet), MS Nut Bolts (IS: 1363 Part I-1984- amended up to date), CI Detachable Joint (IS: 8794- 1988 amended up to date), labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. (Nominal Dia. in mm)
66Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
67100 mm dia
68Providing & Installation of pumpsets for pumping water from Proposed Open Well & Tube well
69Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.Rates are exclusive of GST.
70Up to 5.5 KW (7.5 HP) & head up to 120 mtr.
71Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.
72Above 5 HP and up to 10 HP
73Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes
7480 mm dia
75Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material and labour as per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.
7650 mm dia
77Supply of MS clamp, set of 50x6 mm flat form iron with nuts and bolts etc. holding the riser pipe assembly of submersible pump set.
78Supply & Fixing of ISi marked three core PVC flat submersible cable as per IS 694: 1990 or amended up to date and conductor as per class 5 of IS 8130: 1980 includ ing making connection etc.
793 core 4.0 mm2
80Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. Rates are exclusive of GST.
8110.0 Sq.mm, 4 core
82Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.
8350 mm dia
84Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect.
8550 mm dia
86Providing, laying and jointing rising mains.
87Providing, lowering, laying in trenches, aligning, fixing in position and jointing in trenches Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS: 8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 incl. all taxes (Central and Local) transportation and frieght charges, inspection charges, loading/unloadingcharges, stacking of pipes including cost of labour and material, specials(Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer in Charge.( excluding earth work) with excise Duty Exemption. Note:- Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
88Dia (mm) Type Class
89100 DI K-7
90Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air Valve Flanged/ Screwed type of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1,Body seat ring - Leaded tin bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS 6418 or Screwed type shall have external pipe threads conforming to IS 554 Fasteners - CS Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work.
91Class PN 1.0
9225 mm S-1 Type
93Earth work in excavatin by mechanical means (Hydraulic Excavator) manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets,and dressing of sides,ramming of buttoms.depth up to 1.5 mtr. including taking out the excavated soil, and than returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead od 50 mtr. including required all safety provisiond etc.
94All kinds of soil.
95Earth work in excavatin by mechanical means (Hydraulic Excavator) manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets,and dressing of sides,ramming of buttoms.depth up to 1.5 mtr. including taking out the excavated soil, and than returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50mtr. including alll safety provisions required.
96Ordinary Rock
97Hard Rock ( required blasting)
98Dismating of cement concrete pavement for pipe line . Line and chembers by mechanical means using pneumatic tools, cutting the peripheral edge by cc cutter. Breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated location and disposal of dimantled material up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document not extre payment shall be made be made for trench width than specified, re-handing of material/ earth to complete the tasks as per technical specification and scope of work.
99Providing and laying in position cement concrete M10 grade nominal mix 1 : 3: 6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material , labors, machinary, lighting guarding foe road restoration work in tenches of pipe line and chamber work Measurement for cc work to be made as per standard trench width specified in tender document and no extre payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.
100Providing, laying and jointing Distribution mains.
101Providing, lowering, laying in trenches, aligning, fixing in position and jointing in trenches Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS: 8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 incl. all taxes (Central and Local) transportation and frieght charges, inspection charges, loading/unloadingcharges, stacking of pipes including cost of labour and material, specials(Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer in Charge.( excluding earth work) with excise Duty Exemption. Note:- Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
102Dia (mm) Type Class
103100 DI K-7
104Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M.
105HDPE PE-80 PN-6
10675 mm dia
10790 mm dia
108110 mm dia
109P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.
11050mm dia nominal bore 'B' Class
111Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
112Manually Operated CI Sluice valve of Class PN-1.0
113Dia (mm) PN rating
11480mm 1.0
115100mm 1.0
116Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air Valve Flanged/ Screwed type of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1,Body seat ring - Leaded tin bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS 6418 or Screwed type shall have external pipe threads conforming to IS 554 Fasteners - CS Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work.
117Class PN 1.0
11825 mm S-1 Type
119Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of SS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
120Class PN 1.0
12180 mm dia
122Earth work in excavatin by mechanical means (Hydraulic Excavator) manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets,and dressing of sides,ramming of buttoms.depth up to 1.5 mtr. including taking out the excavated soil, and than returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead od 50 mtr. including required all safety provisiond etc.
123All kinds of soil.
124Earth work in excavatin by mechanical means (Hydraulic Excavator) manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets,and dressing of sides,ramming of buttoms.depth up to 1.5 mtr. including taking out the excavated soil, and than returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50mtr. including alll safety provisions required.
125Ordinary Rock
126Hard Rock ( required blasting)
127Dismating of cement concrete pavement for pipe line . Line and chembers by mechanical means using pneumatic tools, cutting the peripheral edge by cc cutter. Breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated location and disposal of dimantled material up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document not extre payment shall be made be made for trench width than specified, re-handing of material/ earth to complete the tasks as per technical specification and scope of work.
128Providing and laying in position cement concrete M10 grade nominal mix 1 : 3: 6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material , labors, machinary, lighting guarding foe road restoration work in tenches of pipe line and chamber work Measurement for cc work to be made as per standard trench width specified in tender document and no extre payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.
129Construction of Valve/ NRV Chambers
130Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.
131For Class-A loading
132Sluice valve chamber of size1.13m x0.85m x1.27m for pipe size-upto100mm
133Supply, installation, testing and commissioning of Solar Panghat with TW
134Providing, installation, testing and commissioning of AC submersible pump sets with inbuilt or individual solar pump controller with Maximum power point tracking (MPPT) for optimally use the solar panel and maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps..Solar pump shall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope .Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit, accidental short circuit and reverse polarity should be provided. A good reliable on/off switch be provided. The cable shall be ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date.The duty condition of pump set shall be as per scope of work and entire work shall be executed as per technical specification and direction of Engineer in charge.
1353.7 KW (5.0 HP)
136Supply, installation, testing and commissioning of MNRE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably design to withstand wind velocity up to 150km/hr. The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document.
137Providing, installation, testing and commissioning structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting for following staging and capacity of Rotational Moulded Polyethylene water storage tank on it as per indicative drawing given in the bid document. On the Polyethylene tanks, there shall be provision of suitable space for installation of solar panels up to 5.0 KW and further additional 2.5 KW on the side of Steel structure if required as per indicative drawing. Cost of solar panels is not included in this item . The structural steel shall be 120 micron hot dip galvanized iron and foundation of structure shall be in RCC with minimum depth as 2.0 mtr (other than rocky strata). The work includes P&F of Polyethylene Water Storage Tank(IS: 12701, ISI marked, indicating the BIS license No.) of approved make with cover. Providing & fixing 50 mm dia ISI marked G.I. class B pipe for inlet, outlet and over flow pipe and 32 mm GI class B pipe for wash out with GM gate valves at inlet and outlet pipe Including making connection etc. complete as per drawing, technical specification and direction of Engineer in In charge. The scope includes inlet GI pipe from ground level to water tank and outlet pipe from water tank to ground and up to 2.0 mtr away from foundation and overflow pipe is to be interconnected in distribution pipe line. Wash out pipe shall be taken up to a suitable point minimum 5.0 mtr away from tank. Water level controller shall installed to monitor level in tank and shall automatically shut off motor when tank is filled .
138Note: There shall be 5 year service warranty for structure, tank, fittings etc. and suitable provision shall be included in tender document.
1395000 Litre X 2 Nos. PE water tank, staging 10 meter.
140P&F G.I.Pipes (External Work ) with G.I. fittings excluding union (IS 1239 Mark ) including trenching and earth filling etc .
14180mm dia nominal bore
142Making Functional House Tap Connections ( FHTCs ).
143Providing Household Tap Connection as per technical specification and approved drawing as per relevant IS code (amended up to date) from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanical Integrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , not exceeding the flow of 7 LPM at 2 bar and a compression elbow, moulded in single piece/ fusion welded (Complete job) including digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including GM Full-way Valve (IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.
144Note: Road cut and restoration is not part of this item and paid separately.
145For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.
146P & F Bib cock (IS : 8931 mark), superior quality of approved make, chrome plated with complete brass body including brass handle with wt. 300 to 325 gm.15 mm nominal bore. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57521868
AUTHORITY Government Departments
TENDER VALUE 86.44 Lakhs
LAST DATE 26-09-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Construction Of Open Well, Glsr And Providing ,Laying , Jointing Of Pipeline With Functional House Hold Tap Connection Work Under Dmft 17Th Gc With 1 Year Defeat Liability Period At Hab- Ambaver, Kaniya Bhatda, Jhalo Ka Bhilwara, Thala Patiya Gp-Banokada Block- Kumbhalgarh, District- Rajsamand.
Basic Detail
Tender No SE18/26-27
Bidding Type Tender
Location
City Rajsamand
State Rajasthan
Key Dates
Publish Date 15 Sep 2026
Submission Date 26 Sep 2026
Open Date 28 Sep 2026
Finance
Tender Value 86.44 Lakhs
Tender Fee 1500
EMD 1.72 Lakhs
Exemption Available
Document List
3dc17f78-71e2-4db7-a2bb-a4ad0f33c911.html
BOQ_1060107.xls
TD18.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Sep 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

3dc17f78-71e2-4db7-a2bb-a4ad0f33c911.html

xls

BOQ_1060107.xls

pdf

TD18.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender