Tender For Extension Of 132Kv Main I Main Ii And Transfer Bus Alongwith Construction Of 04 Nos. 132Kv Bays And Other Associated Works At 132Kv Substation Asha Under Etd Hardoi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
12 Oct 2026
26 days left
EMD
1.71 Lakhs
Bank guarantee accepted
Document Fee
1770
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Extension Of 132Kv Main I Main Ii And Transfer Bus Alongwith Construction Of 04 Nos. 132Kv Bays And Other Associated Works At 132Kv Substation Asha Under Etd Hardoi
BOQ
| Sl. No. | Item Description |
| 1 | Supply |
| 2 | Earthing |
| 3 | MS Strip (75x10 mm) |
| 4 | MS Strip (50x6 mm) |
| 5 | MS Strip (25x6 mm) |
| 6 | MS Round Bar 40mm |
| 7 | 40mm dia MS Electrode of 3 Metre length |
| 8 | GI pipes of different sizes |
| 9 | 2\\" GI pipe for Pilfer Proof metering |
| 10 | 1\\" GI pipe for Pilfer Proof metering |
| 11 | 60W LED light fitting (for Bays) |
| 12 | Retro reflating name plates |
| 13 | 10kV Insulation tester (Megger or equivalent make ) |
| 14 | Fire Extinguisher |
| 15 | 50 Litre Mechanical foam type poratable /trolly /wheel mounted extinguisher |
| 16 | Supply of following Fire extinguisher carbon dioxide as per IS specn. No. 2878/1986 and tech. specn. Enclosed. |
| 17 | 22.5kg |
| 18 | 4.5kg |
| 19 | Supply of sand buckets as per tec. Specn. |
| 20 | Supply of stands for sand buckets suitable for 10 bucket as per tech. specn. |
| 21 | Bus Post Clamps suitable for |
| 22 | PG Clamp Moose/Panther |
| 23 | PG clamp Panther/Panther |
| 24 | PG clamp Moose/Moose |
| 25 | 132KV Isolator clamp for panther |
| 26 | Flexible copper bond 16mm dia, 500mm length |
| 27 | Bus Post clamp suitable for panther |
| 28 | Twin Panther |
| 29 | Moose |
| 30 | Twin moose |
| 31 | 132KV tension Insulator string and associated hardware fitting without turn buckle suitable for moose conductor |
| 32 | 132KV tension Insulator string and associated hardware fitting with turn buckle suitable for moose conductor |
| 33 | 132KV suspension Insulator string and associated hardware fitting with drop clamp suitable for moose conductor. |
| 34 | Battery & Battery charger |
| 35 | 110V, 200AH Batteries complete set |
| 36 | Battery charger for 110V 200AH Batteries |
| 37 | LT Switchgear |
| 38 | 110V DC Distribution board |
| 39 | 415V AC Lighting Distribution Board |
| 40 | 415V ACDB |
| 41 | Erection Work |
| 42 | Carriage of Structure & Other Materials. |
| 43 | Sorting out and stacking of main & auxiliary structure as per BOM at EFU Naini (Allahabad) |
| 44 | Loading of structure on Pt. Truck / trailer at EFU Naini. |
| 45 | Transportation of structure from EFU Naini, Allahabad to different sub-stations |
| 46 | Unloading and proper stacking of structure parts at different Sub-stations |
| 47 | Structure & Earthing Material |
| 48 | EREC,STRUCTURES, MAIN/AUX, INCLACCS: with MS angles, channels, plates, nuts, bolts, step bolts, U bolts, spring washers, etc. and any other required material |
| 49 | LAYG MS BAR700MM-40MM DIA 40mm for Main Earthmat |
| 50 | LAY,ELECTRODE,MS ROUND,40MMX3M,BLW GND 40mm Dia MS Electrode (3 M Long) |
| 51 | FRESH EARTHG,W/FLAT,75X10MM |
| 52 | FRESH EARTHG,W/FLAT,50X6MM |
| 53 | FRESH EARTHG,W/FLAT,25X6MM |
| 54 | Circuit Breaker |
| 55 | Erection of 145KV SF6 Circuit Breakers |
| 56 | Isolator |
| 57 | Erection of 145KV,1250A,31.5KA, Line Isolator(LI) Motorised without PI |
| 58 | Erection of 145KV,1250A,31.5KA, Bus Isolator(BI) Motorised without PI |
| 59 | Erection of 145KV,1250A,31.5KA, Tandem Isolator(TI) Motorised without PI |
| 60 | Current Transformer |
| 61 | Erection of 145kV CT For Feeders Ratio (800-400-200/1-1-1 A) Polymer Type |
| 62 | Erection of Terminal Connector for 145KV CT |
| 63 | Erection of Junction Box for 145KV CT |
| 64 | CRP & SAS (as per Technical Specification of SAS) |
| 65 | Erection of Simplex type Control & Relay Panels as per Technical Specification of SAS for 132KV Feeder along with two point earthing with the help of 26x6mm MS Flat. |
| 66 | Integration of existing C&R Panel with existing SAS |
| 67 | Potential Transformer |
| 68 | Erection of 145KV PT of 0.2 acc. Class |
| 69 | Erection of Terminal Connector for 145KV PT |
| 70 | Erection of Junction Box for 145KV PT |
| 71 | Surge Arrester |
| 72 | Erection of 120kV Polymer type Surge Arrester |
| 73 | Post Insulator |
| 74 | Erection of 145kV Porcelain Bus Post Insulator |
| 75 | Erection of 145kV, 72.5kV Porcelain Bus Post Insulator |
| 76 | Control Cable |
| 77 | 1.1 KV PVC FRLS Unarmoured Copper Control Cable |
| 78 | LAYING 2CX2.5SQMM UNARM CTRL CABLEincluding Terminations of cables (COMPLETE IN ALL RESPECT) |
| 79 | LAYING 4CX2.5SQMM UNARM CTRL CABLEincluding Terminations of cables (COMPLETE IN ALL RESPECT) |
| 80 | LAYING 6CX2.5SQMM UNARM CTRL CABLEincluding Terminations of cables (COMPLETE IN ALL RESPECT) |
| 81 | LAYING 10CX2.5SQMM UNARM CTRL CABLEincluding Terminations of cables (COMPLETE IN ALL RESPECT) |
| 82 | Energy Meter and Cubicle |
| 83 | EREC OF ABT ENERGY METER |
| 84 | EREC OF ABT ENERGY METERING PANEL with one main & one check rack |
| 85 | Equipment for data integration to SAMAST Module |
| 86 | INSTALLATION,DCU/GATEWAY/ETC including installation of Network Switch-16 Port, (14Cu+2 FO with FO Communication module (industrial frade), LIU (Light Interfacing Unit) with patchcord & accessories, Network Switch-08 Port, Data Concentrator (DCU)/ Communication Gateway (IG), laying of Lan Cable, PVC Conduit Pipe-3/4, OFC Cable Armoured (6P), HDPE Conduit Pipe 32mm |
| 87 | SWITCH,NETWORK,16 PORT,14CU+2FO |
| 88 | DATA CONCENTRATOR,DCU/COMM GATEWAY |
| 89 | CABLE,LAN |
| 90 | CONDUIT PIPE,PVC,FLXBLE,50MM |
| 91 | CABLE,FIBER OPTIC,ARMRD,6CORE |
| 92 | LIU,6 PORT,W/ACCS |
| 93 | SWITCH,NETWORK,8 PORT,6CU+2FO |
| 94 | Pilfer Proofing Work |
| 95 | GI pipes of the cable with GI Pipes of following sizes, complete bending and fixing of pipes along with making threads, elbow and other required material of 145kV CTs and PTs. |
| 96 | 2\\" GI pipe for Pilfer Proof metering |
| 97 | 1\\" GI pipe for Pilfer Proof metering |
| 98 | Fire Fighting Equipments |
| 99 | FIRE EXT,MECH FOAM,50LTR |
| 100 | FIRE EXT,CO2,IS 2878/1986,22.5KGS |
| 101 | FIRE EXT,CO2,IS 2878/1986,9KGS |
| 102 | FIRE EXT,CO2,IS 2878/1986,4.5KGS |
| 103 | SAND BUCKET |
| 104 | STAND FOR SAND BUCKET |
| 105 | Conductors |
| 106 | CONDUCTOR,ACSR MOOSE |
| 107 | CONDUCTOR,ACSR PANTHER |
| 108 | Hardware Fittings and Connectors |
| 109 | PG Clamp Moose/Panther |
| 110 | PG clamp Panther/Panther |
| 111 | PG clamp Moose/Moose |
| 112 | 132KV Isolator clamp for panther |
| 113 | Flexible copper bond 16mm dia, 500mm length |
| 114 | Bus Post clamp suitable for panther |
| 115 | Twin Panther |
| 116 | Moose |
| 117 | Twin moose |
| 118 | FITT,BLTD,SINGLE TENSION,MOOSE WITH TURN BUCKLE |
| 119 | FITT,BLTD,SINGLE TENSION,MOOSE WITHOUT TURN BUCKLE |
| 120 | FITT,BLTD,SINGLE SUSPENSION,MOOSE |
| 121 | FITT,BLTD,SINGLE SUSPENSION,PANTHER |
| 122 | Battery & Battery charger |
| 123 | 110V, 200AH Batteries complete set |
| 124 | Battery charger for 110V 200AH Batteries |
| 125 | LT Switchgear |
| 126 | 110V DC Distribution board |
| 127 | 415V AC Lighting Distribution Board |
| 128 | 415V ACDB |
| 129 | Misc Work |
| 130 | Providing & fixing of updated single line diagram in PVC sheet of size 6x6 feet of complete 132/33 KV switchyard of 132 KV S/S, Asha as per instruction by concerned JE/SDO. |
| 131 | Safe Loading of 1 No. Drums of ACSR Moose/Panther Conductor on suitable Vehicle after due Shifting from Storage Place to Loading Place at 132KV Sub-station, Asha. (1 Job per Drum) |
| 132 | Safe Loading of 1 No. Drums of ACSR Moose/ Panther Conductor on suitable Vehicle after due Shifting from Storage Place to Loading Place at different sub-station with TC Zone, Lucknow (1 Job per Drum). |
| 133 | Safe Carriage of above ACSR Moose/ Panther Conductor in Drums, Loaded on the Vehicle arranged by the Contractor from various sub-stations within TC Zone Lucknow to Safe Unloading Place at Existing 132/33KV Sub Station, Asha (Approx. Distance 300 Km). |
| 134 | Providing & Fixing of Junction Box of size 280 × 225 × 150 mm duly made of 16 SWG Sheet and Painted with Smoke Grey Colour Synthetic Enamel Paint and Fitted with 1 No. 6 Amp. SP MCB on Anodized M.S. Channel, 1 No. Bakelite Fuse Fitting with 6 Amp. NS 6 type HRC Fuse, 1 No. Copper Neutral Link, Bakelite Terminal Block of 4 Terminals, Cable Glands suitable for 2C × 2.5 mm2 / 4C × 2.5 mm2 size Incoming / Outgoing Control Cables etc., then Installation of Junction Box on M.S. Round Pole at designated Height with the help of suitable M.S. Clamps alongwith Earthing of the Junction Box with 12 SWG G.I. Wire including Cable Terminations with Satisfactory Testing & Commissioning |
| 135 | Laying of 2C x 2.5sq.mm size/ 4C x 2.5sq.mm size Control cables from LT A.C.D.B. Cubical to various junction Boxes for Switchyard Lighting through through Excavated Trench of size 300x600 mm, Covering the cables with River Sand & Brick Lining along & Over the Cable, then Back filling & levelling of the trench after Laying of Cables. |
| 136 | Laying of above Control Cables from L.T. Lighting Junction Box to LED Street Light Fittings by clamping with suitable M.S. Strip Clamp with proper Dressing etc. |
| 137 | NOC from Directorate of Electrical safety, Lucknow for 4 nos. line bays |
| 138 | Making of Shielding Mesh, Diamond earthing, Delta etc and earthing of various equipments and elements with following details: |
| 139 | Making of Shielding Mesh for 3nos. 132KV LA by Fabrication of 06nos 3 Meter Long Electrode with 40 mm dia. M.S. Rod having 150 mm Long Conical Shape and then its Piercing Vertically in the Ground with top 500 mm below Ground Level, its Welding with 75x10 mm size M.S. Flat for Making of Shielding Mesh for LAs and Finally, Connecting the Shielding with Main Earth Mat at 2 Places and finally Painting with Black Anti-Corrosive Paint, with due Digging of Earth / Trench, its Back Filling. Two no risers of 75x10mm MS Flat will be welded with exixting main earth mat to Auxiliary structure, one separate riser will be taken from the laid earth mat to corresponding LA through surge counter for making of proper mesh. |
| 140 | Painting of M.S. Earthing Strips by Rubbing with Sand Paper & Wire Brush, then Painting with 1 coat of Red Oxide Primer & 2 coats (The 2nd coat of Paint shall be applied at the gap of 48 hrs. when 1st coat of Paint is done & Checked by concerned A.E. / J.E.) of 1st quality Synthetic Enamel Paint of Asian / Berger / Nerolac make in Bus Green / Black Colour as per Details below : |
| 141 | 75 × 10 mm size M.S. Earthing Strip in Bus Green Colour |
| 142 | 50 × 6 mm size M.S. Earthing Strip in Bus Green Colour |
| 143 | 25 × 5 mm size M.S. Earthing Strip in Black Colour Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysOct 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender