Housing Urban and Rular Development Government Departments Closing in 7 days TDR #57520806

Tender For General-Running Maintenance Contract For Various Offices Under Pwd Electrical Section Thiruvalla -2026-2027-General Electrical Work

Issued by Government Departments · Pathanamthitta, Kerala
Tender Value
84662
Estimated cost
Bid Submission
23 Sep 2026
7 days left
EMD
2117
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathanamthitta → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for General-Running Maintenance Contract For Various Offices Under Pwd Electrical Section Thiruvalla -2026-2027-General Electrical Work

BOQ

Name of Work:- GENERAL-Running maintenance contract for various offices under PWD Electrical Section Thiruvalla -2026-2027-General Electrical Work
Sl. No. Item Description
1AMC of Offices Coming under PWD Electrical Section Thiruvalla
290.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
390.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
4OD61813/2026-2027:Supply, conveyance, installation, testing and commissioning of 1x20W box type LED light fittings with all accessories and lamp in place of defective fittings and giving connections as required
5OD61812/2026-2027:Supply, installation, testing and commissioning of 700lm pressure die cast housing Bulk head with IP65 protection & IK 08 having efficacy not less than 105lm/W and giving connection with 3 core flex wire as required.
6OD61816/2026-2027:Supply and installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.<br>300 / 305 mm sweep light duty exhaust fan
71.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
8OD61817/2026-2027:Supply and renewing ceiling fan Capacitor
91.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
10OD61814/2026-2027:Supply and fixing Step fan regulator - socket size
111.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
121.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
131.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
141.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
151.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
161.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
171.23.1:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
181.23.3:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch
191.23.4:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 amp socket outlet
201.23.5:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet
211.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
221.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
231.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
241.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
251.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
261.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
271.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
281.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
291.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
301.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
311.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
321.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
332.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
342.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole
352.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
362.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
372.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
382.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
392.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
402.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps
41OD61806/2026-2027:Bi Pin holder for flourescent fittings
42OD61815/2026-2027:Supply & fixing 32A HRC Fuse Base with HRC Fuse link
43OD61809/2026-2027:Supply & fixing 32 A, 2 Way neutral links mounted on DMC/SMC base
44OD61810/2026-2027:Charges for dismantling the existing EI complete, making good the damages of walls and conveying the dismantled materials for storage
45OD61811/2026-2027:Supply and fixing Surge Protection Device (SPD), Type1+2 , discharge current 50kA(L-N), 70kA(N-E), protection level-1.5kV as required
46OD61807/2026-2027:Supply and fixing meter box (SMC) having following specification. 1. Hinged door, seperate compartment for energy meter and accessories 2. Transparent window for viewing meter reading. 3. Suitable arrangement for fixing MCB/Isolator, single phase energy (KWh) meter etc. 4. 32A DP MCB. 5. 32A HRC fuse base with 25A fuse link 6. 32 A, 2 Way neutral links mounted on DMC/SMC base
471.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
4890.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
4990.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
5090.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57520806
AUTHORITY Government Departments
TENDER VALUE 84662
LAST DATE 23-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for General-Running Maintenance Contract For Various Offices Under Pwd Electrical Section Thiruvalla -2026-2027-General Electrical Work
Basic Detail
Tender No PWD/BLDG/TR/10017/2026
Bidding Type Tender
Location
City Pathanamthitta
State Kerala
Key Dates
Publish Date 15 Sep 2026
Submission Date 23 Sep 2026
Open Date 26 Sep 2026
Finance
Tender Value 84662
Tender Fee 555
EMD 2117
Exemption Not Available
Document List
1viewsbd_merged.pdf
b06192ff-0a88-4a66-94cd-7cf04b3d02bd.html
BOQ_1474008.xls
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
pdf

1viewsbd_merged.pdf

html

b06192ff-0a88-4a66-94cd-7cf04b3d02bd.html

xls

BOQ_1474008.xls

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders