Tender For Mt Garage With Office And Store At 2Nd Aapbn Aalo.
Tender Value
1.13 Crore
Estimated cost
Bid Submission
21 Sep 2026
1 days left
EMD
1.13 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
West Siang → Arunachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Mt Garage With Office And Store At 2Nd Aapbn Aalo.
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing brick work in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 2 | Dismantling doors, windows and clerestory windows (steel or wood) shutters including chowkhats, architrave, hold fasts etc complete and stcking within 50 m lead. B) of area beyond 3 sq.m |
| 3 | Dismantling the tile work in floors and roofs laid in cement including stacking of materials within 50 m lead.b)For thickness of tiles above 25 mm and up to 40 mm |
| 4 | Dismantling cement, asbestos, celotax or other ceiling or partition hard board partition wall including stacking of serviceable materials and disposal of unserviceable materials within 50 m lead. |
| 5 | Dismantling precast concrete or stone slabs in wall, partition walls etc including stacking within 50 m lead. B). Thickness above 38 mm and up to 75 mm |
| 6 | Dismantling ballies in posts, purlins or rafters including stacking within 50 m lead. |
| 7 | Dismantling GI sheet roofing including ridges, hips, valleys and gutters etc and stacking the material within 50 m lead. |
| 8 | Dismantling GI sheet roofing including ridges, hips, valleys and gutters etc and stacking the material within 50 m lead. |
| 9 | Demolishing RCC work including stacking of steel bars and disposal of un-serviceable materials within 50 metres lead. |
| 10 | Demolishing cement concrete 1 : 4 : 8 or leaner mix including disposal of material within 50 m lead. |
| 11 | Demolishing cement concrete 1 : 3 : 6 or richer mix including disposal off material within 50 metres lead. |
| 12 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 13 | Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete. |
| 14 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 15 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:b) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level.(Wall) |
| 16 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 17 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.c) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 18 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 19 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 20 | Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 21 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 ( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 22 | Brick work with best available local bricks in plinth and in Superstructure in cement mortar 1:3 (1 cement : 3 fine sand). |
| 23 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 24 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 25 | Providing and laying damp proof course 50 mm thick with cement concrete 1 : 2 : 4 (cement : 2 coarse sand : 4 stone aggregate 10 mm nominal size) |
| 26 | Chequered terrazzo tiles 22 mm thick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete:a) Light shades using white cement |
| 27 | Granite Stone 12mm thick in flooring, slabs, skirtings, risers of steps and Dado in 12mm thick cement Plaster 1:3 (1 Cement : 3 coarse sand) painted with white cement slurry. |
| 28 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. |
| 29 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |
| 30 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth. |
| 31 | Centring and shuttering including strutting, propping etc and removal of form work for |
| 32 | b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 33 | c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 34 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 35 | e) Column, pillars, posts and struts etc. |
| 36 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 37 | Neat cement punning. |
| 38 | Finishing walls with wall putty of approved brand and munufacture and required shed on new work (three or more coat) to give an even shed. |
| 39 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 40 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 41 | Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.c) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 42 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 43 | Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 44 | Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 ( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). |
| 45 | Brick work with best available local bricks in plinth and in Superstructure in cement mortar 1:3 (1 cement : 3 fine sand). |
| 46 | Reinforcement of RCC work including bending, binding and placing in position complete. |
| 47 | Providing and fixing MS grills of required pattern in wooden/MS Angle/Brick wall frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill. At windows & Ventilators etc. |
| 48 | Providing and fixing Staillness steel (Grade-304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, I/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer-in charge, (for payment purose only weight of stainless steel member shall be considered excluding fixing acessories such as nuts, bolts, fasteners etc). As per the instruction of Engineer. |
| 49 | Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately). |
| 50 | White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry. |
| 51 | White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry. (Toilet) |
| 52 | Providing and fixing plain timber Door and steel angle 45x45x5mm fasten with steel strip of 25mmx4mm, including steel chowkat and necessary iron fittings and screws including painting with smoke grey paint two or more coat above priming coat. |
| 53 | Providing and fixing Glazed window in steel frame of angle 25mmx 25mmx4mm in frame of 30x30x4mm fastened with bead/putty including steel chowkhat ,Gril& necessary fittings & screws as per design and drawing including painting with Red Oxide paints.. |
| 54 | Centring and shuttering including strutting, propping etc and removal of form work for c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height). |
| 55 | d) Lintels, beams, girders, bressumers and cantilevers etc. |
| 56 | e) Column, pillars, posts and struts etc. |
| 57 | 12 mm cement plaster 1 : 3 (1 cement : 3 fine sand). |
| 58 | Finishing walls with wall putty of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. As directed by the Engineer incharge. |
| 59 | Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 60 | Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade. |
| 61 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete. |
| 62 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade. |
| 63 | Applying priming coat with ready mixed pink primer of approved brand and manufacture on Steel work complete. |
| 64 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for Steel work of approved brand and manufacture in all shades on new work to give an even shade. |
| 65 | Construction of Septic Tank 3.8 mx2.8m x1.8m as per complete standard drawing & design. |
| 66 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design. |
| 67 | Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-level flushing cistern with fittings and brackets 40 mm white porcelain in enamel led flush band, 20 mm over flow pipe with specials and mosquito proof coupling of approved municipal design complete including cutting and making good the walls and floors where required. |
| 68 | Providing and fixing white vitreous china water closet squating pan (Indian types WC Pan) size 580 mm with 100 mm and sand iron P or S Trap, 12.5 litre high level CI Flushing cistern (of approved make) with fittings RS or CI Brackets,32 mm dia galvanized steel telescopic flush pipe with fittings and clamps, 20 mm GI overflow pipe with specials and mosquito proof coupling of appeoved municipal design and GI chain and pull complete including painting of cistern and fitting, cutting making good the walls and floors where required. a). Long pan patten WC Pan |
| 69 | Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC. (250mmX130mmx30mm) |
| 70 | Providing and fixing CP Brass chain and rubber plug complete for sink or wash basins. |
| 71 | Providing and fixing MI Fisher union for wash basin. B) 40 mm dia. |
| 72 | Providing and fixing CP brass or MI trap for wash basin and sinks. B). 40 mm dia. |
| 73 | Providing and fixing sand Cast iron/cast iron(spun) soil, waste and Vent Pipes. (b) 75 mm dia |
| 74 | Providing and laying cement concrete 1 : 5 : 10(1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design. a) 100 mm dia SW pipes |
| 75 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality. |
| 76 | Constructing brick masonry manhole with 2nd class bricks in cement mortar1 : 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete1:4: 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cementc oncrete1:2:4mix(1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a)Insidesize90x80cmand45cmdeepincludingCIcoverwithframe(light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg). |
| 77 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers. |
| 78 | Providing and fixing 100 mm sand CI 'P' or 'S' trap. |
| 79 | Construction of water storage Tank (size 2 x 2 x 1.8 mtrs) as per complete standard drawing & design. |
| 80 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).a) 15 mm nominal bore (internal work). |
| 81 | Providing and fixing GI pipes complete with GI fittings including trenching and refillingetc (external work).b) 32 mm nominal bore(Externall work). |
| 82 | Providing and fixing brass stop cock of approved quality |
| 83 | b) 20 mm nominal bore |
| 84 | Providing and fixing brass bib cock of approved quality.15 mm nominal bore |
| 85 | Providing fixing best quality PVC sintex of aproved quality. |
| 86 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 87 | Crusher Run Macadam Base (Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller toclause 410 to form a layer of sub-base/Base) (i) For 53 mm maximum size |
| 88 | Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site,laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 daySep 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender