Tender For Repair And Maintenance Of electrical installation Work Of Various Community Centres Of Ward No. 4, 5, 6, 7, 8 & 9 Under Electrical Sub Division No. 2, M.C., Chandigarh.
Tender Value
4.99 Lakhs
Estimated cost
Bid Submission
23 Sep 2026
7 days left
EMD
9997
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of electrical installation Work Of Various Community Centres Of Ward No. 4, 5, 6, 7, 8 & 9 Under Electrical Sub Division No. 2, M.C., Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Make: ABB, Havell’s, Legrand, Northwest Wipro, Norisys, Captree (Murano), Schneider. DSR 1.25 |
| 2 | LED 100 WATT Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single cor cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. . Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). The luminary should be make Philips/ Crompton/ Havells/ Surya/ Wipro/ Bajaj/ Halonix. Dismantled light will be the property of the contractor. The work shall be executed upto entire satisfaction of EIC. DSR 8.17.3 |
| 3 | LED Batten light with Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light including dismantling of existing unserviceable light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short &Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 ,Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy>135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Make: Philips, Wipro, Bajaj, Havell’s, Twinkle, Surya, Halonix. 18- 22 Watt DSR 8.11.1 |
| 4 | Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 5 | 3 pin 5/6 amp switch outlet DSR 1.24.1 |
| 6 | 15/16 amps switch outlet DSR1.24.3 |
| 7 | 3 pin 5/6 amp socket outlet DSR1.24.4 |
| 8 | 15/16 amps socket outlet DSR 1.24.5 |
| 9 | LED Panel light Surface Type/Recess Type as per site requirement 2x2 ft., 36 WATT (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light Surface Type/Recess Type as per site requirement 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Make: PHILIPS, Wipro, Bajaj, Havells, Twinkle, Surya, Halonix. DSR 8.8.4 |
| 10 | Providing and fixing 125 A 36 KA 4 POLE rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Make : Legrand/ Seimens/ Schneider/ L&T/ABB |
| 11 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A Make : Legrand/ Seimens/ Schneider/ L&T/ABB DSR 2.13.2 |
| 12 | Supply & Erection of Three Phase Sensor based Timer and Contactor assembled in 22 gauge CRCA sheet enclosure duly powder coated with the following accessories (Three Phase) of Make Amsons /L&T/Scheinder or equivalent as approved by the Engineer-in-Charge. It shall conform to latest relevant IS Code:-1. It shall have 3 contactors of capacity 40 Amp. Each of made BCH, Legrand, L&T or Siemons. The contractor should be of AC-3 duty 2 pole, 220/240 V coil Voltage.2. It shall have Auto/Manual switch, light activated switching system with allied accessories as required. 3. It shall have kit-kat fuse unit of 40 Amp capacity. The fuse unit shall conform to latest relevant IS code for protection of timers, bakelite sheet & other components as per requirement as site. 4. It shall be housed in a powder coated 22 gauge M.S sheet cabinet fo its protection. 5.The device shall be provided/fixed in the existing pedestal box in such a way so that it operates at correct time i.e. at rising/setting of Sun. The Sensor shall be included time watch to operate as required. The work shall be executed to the entire satisfaction of Engineer-in-charge. Warranty:- IT SHOULD STAND WARRANTY FOR ONE YEAR TOWARDS ANY MANUFACTURING DEFECTS. |
| 13 | S/E of Ceiling Fans 1400mm sweep without fan regulator including M.S. pipe as per site requirement and wiring complete in all respect Make Bajaj (Sabse Tej EE) or equivalent of Crompton, Orient, Havells, Atomberg including making connection with 23/.076' flexible wire to be adjacent fan point with regulator . The work shall be executed to the entire satisfaction of Engineer in charge. |
| 14 | P/F of heavy duty Air Circulator Wall fans of size 450 mm, RPM 1400± 5%, power input 120-130 watt, 220-240 volt, 50Hz single phase, 3 speed of Make Crompton/ Havells/ Phillips/Bajaj/Khaitan. |
| 15 | Supply and Erection of Exhaust fan (heavy duty motor with copper wound metallic body) following size complete with motor, mettalic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation,epoxy powder coating along with mettalic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of EIC. Size 12\\" Sweep 900 RPM with louver of Havells make Turbo Force SP/ Orient make Industrial heavy duty / Crompton make HDEF EXHD 300- 6-1 / Bajaj make Supreme DLX only. |
| 16 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole Make: ABB, Havells, Schneider, Legrand, L&T, Hager. |
| 17 | Full stator copper rewiding of an ceiling fan (condensor type) of 1200/1400 mm sweep including (ball bearing if required) and cleaning and insulating the stator slots, sleeving, soldering, wrapping of cotton tape, re-assembling, varnishing and testing etc. complete in all respect. (in working condition) |
| 18 | MODULAR G.I. BOXESSupplying and fixing following sizes / modules, GI box along with Modular base & cover plate for modular switches in recess etc as required. Make: Legrand (Arteor), Hager(Insysta), Norysis (Cube), Captree (Murano), Schneider (ZENcelo). |
| 19 | 2 Module (75mmX75mm) |
| 20 | 3 Module (100mm x75 mm) |
| 21 | 4 Module(125mmX75mm) |
| 22 | 6 Module (200mm x 75mm) |
| 23 | 8 Module (125mm x125mm) |
| 24 | 12 Module (200mmX150mm) |
| 25 | Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/PVC conduit as required. |
| 26 | 1x1.5 mm sq. |
| 27 | 2x2.5 mmsq. |
| 28 | 2x4 mmsq. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysSep 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender