Public Administrative Department Local Bodies Closing in 5 days TDR #57517362

Tender For Repair/Renovation Of Mcd Dispensary And Its Staff Quarters In Block 26 Trilokpuri In Ward No. 191, Mayur Vihar Phase-I Shah (South) Zone.Sub-Head :- Provision Of electrical installation & Fans For Staff Quarters & One Ac For Medicine Room

Issued by Local Bodies · Delhi, Delhi
Tender Value
2.19 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
5 days left
EMD
4607
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Renovation Of Mcd Dispensary And Its Staff Quarters In Block 26 Trilokpuri In Ward No. 191, Mayur Vihar Phase-I Shah (South) Zone.Sub-Head :- Provision Of electrical installation & Fans For Staff Quarters & One Ac For Medicine Room In Dispensary .

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Sep-2026 corrigendum_6 Other 21-Sep-2026

BOQ

Name of Work:- Repair/Renovation of MCD Dispensary and its staff quarters in Block 26 Trilokpuri in Ward no. 191, Mayur Vihar Phase-I Shah (South) Zone.Sub-Head :- Provision of EI & Fans for staff quarters & one AC for Medicine Room in Dispensary .
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
2Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
3Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 5/6 &15/16A modular switch, connections etc. as required.
4Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
5Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
7Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (a) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
8Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
9Supply of 10'' (250 mm )sweep, 1250 rpm exhaust fan Fresh air Typecomplete with shutter, blades etc as required.
10Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
11Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door
12Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole
13Supplying and fixing following rating ,double pole,240 volt,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required 63 Amps
14LED Batten light (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness ≥1.20 mm 18-22 watt
15Supply , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU),copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 1.5 TR with 5 Star BEE Rating
16S/I/T/ C of 4 KVA Voltage stabilizer having input voltage 150V - 270V and output voltage of 195 V -245 V .
17S/I/T/C of stand for split AC
18S/I/T/C of copper pipe for split AC
19S/I/T/C of Drain Pipe
20S/I/T/C of 3 Core, 4 Sqmm. Electrical wire for Air Conditioner
21Supplying and fixing brass batten/ angle holder including connection etc. as required.
22Supply of 9 Watt LED retrofit lamp suitable for B22 holder
23Supply ,Installation, testing and commisioning of ceilling fan with Brush Less Direct Current (BLDC) Motor , class of insulation :B,3 nos. metal(Aluminium alloy) blades, 30cm long down rod , 2 nos. canopies ,shackle kit , saftey rope, copper winding , steel /AL body Power Factor not less than 0.9 , Service value (CM/M/W) minimum as below , 350 RPM (tolerence as per IS:374-2019), THD ( Total Hormonic Distortion) less than 10% , suitable for operation with regulator for speed control and all remaining accessories including saftey pin , nut bolts , washers, temperature rise =75 degree C (max.), insulation resistance more than 2 mega ohm , suitable for 230 V , 50 HZ, single phase AC ceilling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. (c) 1200mm, service value >=6.0 CM/Min/Watt , air delivery 210 CM/ Min (Minimum)
24Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >70 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy > 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above90°B). 70 watt
25P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
26Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57517362
AUTHORITY Local Bodies
TENDER VALUE 2.19 Lakhs
LAST DATE 21-09-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Repair/Renovation Of Mcd Dispensary And Its Staff Quarters In Block 26 Trilokpuri In Ward No. 191, Mayur Vihar Phase-I Shah (South) Zone.Sub-Head :- Provision Of electrical installation & Fans For Staff Quarters & One Ac For Medicine Room In Dispensary .
Basic Detail
Tender No EEE-I/2026-27/6.4
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 15 Sep 2026
Submission Date 21 Sep 2026
Open Date 01 Jan 0001
Finance
Tender Value 2.19 Lakhs
Tender Fee 590
EMD 4607
Exemption Not Available
Document List
5997a140-14d7-4a29-b835-8c3318ac461c.html
BOQ_339181.xls
condition.pdf
Tendernotice_1 (10).pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

5997a140-14d7-4a29-b835-8c3318ac461c.html

xls

BOQ_339181.xls

pdf

condition.pdf

pdf

Tendernotice_1 (10).pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders