Tender For Construction Of Iti At Tripari,Block Kharar District Sas Nagar,Punjab. (Balance Work)
Tender Value
2.53 Crore
Estimated cost
Bid Submission
25 Sep 2026
7 days left
EMD
5.07 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
S.a.s Nagar → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Iti At Tripari,Block Kharar District Sas Nagar,Punjab. (Balance Work)
BOQ
| Sl. No. | Item Description |
| 1 | Civil Works Construction of Main Building Two storeyReinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.Beams Ground Floor |
| 2 | First Floor |
| 3 | Second Floor |
| 4 | Cold twisted deformed (Ribbed/ Tor steel) Bars (Fe 415 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including binding & bending and placing in position complete |
| 5 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. Ground Floor |
| 6 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 7 | Providing and fixing in position gratings 150mm x 150mm for gully trap.(a) H.C.I. Grating including painting with black bitumastic superior paint of approved manufacture three coats. |
| 8 | Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. |
| 9 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping (Using mechanical mixer for mixing of material). Second Floor |
| 10 | Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : (iv)Udaipur Green Marble Tiles of thickness 18mm to 20mm (b) Slabs sizes below 0.50 SqmGround Floor |
| 11 | Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishingGround Floor |
| 12 | First Floor |
| 13 | Extra rate for First Floor |
| 14 | Providing and laying vitrified floor tiles 600x600mm size premium quality, manufactured using Double Charge Technology, with water absorption less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 fine sand) for new flooring laid with cement based high polymer modified quick set tile adhesive (water based) of approved make IS 15477 marked using 5 Kg adhesive per sqm of tile area in average 3mm thickness over existing base, including grouting the joints (Tiles to be laid with 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout). with cement based grout and matching pigments etc., complete (Design is homogenous throughout the tile body). Ground Floor |
| 15 | First Floor |
| 16 | Extra rate for First Floor |
| 17 | Coloured Granite stone tiles 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.Ground Floor |
| 18 | Extra labour for projected nosing of stair case of any shape and design |
| 19 | Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. Ground Floor |
| 20 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
| 21 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : For fixed portion & Chaukhat |
| 22 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 23 | Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop.18.48 csr |
| 24 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) With float glass panes of 5.5 mm thickness. |
| 25 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineer-in-charge. |
| 26 | Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 5mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for styles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc.complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge. |
| 27 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973, Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick |
| 28 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 29 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300mm x 16mm |
| 30 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two coats to get required finish |
| 31 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 32 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. With ordinary quality Paint |
| 33 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 34 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 35 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 36 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 37 | Construction of Plinth protection complete as per drawing.Earth work in exavation in foundations, trenches, etc. in all kinds of soil where pick jumper work is not involved and not exeeding 2.0 Mtr. depth and subsequent filling around masonary in 15 cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 Mtr. complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of material) |
| 38 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material). |
| 39 | 12.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge. |
| 40 | Construction of Boundary Wall With Grill 12.5 mm thick cement plaster 1:4. |
| 41 | Construction of Internal Concrete Roads, Pavements with Pavers & foot Path Earth filling with good quality earth obtained from out side including compensation of earth, loading, unloading, carriage from outside the peremises to site of work, spreading, laying watering compacting with road roller complete as per specifications. |
| 42 | Cement concrete 1:4:8 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type |
| 43 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge IS Code: 15658(2006) |
| 44 | Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours. |
| 45 | Plain cement concrete M-20 grade precast kerb 250mm high with bottom width 165mm and top width 115mm fixed in position including carriage to site of work complete as per technical clause 408 of MORT&H specifications |
| 46 | Providing and fixing 160 mm dia SWR U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge CSR (30.81i) |
| 47 | Providing and fixing 160 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. (CSR 30.81ii) |
| 48 | Expansion Joint for Horizontal Joints |
| 49 | Vertical Joints |
| 50 | Public Health WorkSub Head-1.1 Internal Sewerage SystemProviding and fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS -13592 of approved make (to the approval of Engineer-in-charge )including cutting, jointing, wastage, but excluding cost of lead jointing.Type - B110mm o/d SWR UPVC pipe line laid complete |
| 51 | 90 mm o/d SWR UPVC pipe line laid complete |
| 52 | Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonage pipes as per as per IS - 14735 of approved make (to the approval of Engineer-in-charge) including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 110mm i/d pipesCowls |
| 53 | Collars |
| 54 | Single Tea with door |
| 55 | Elbow 90 degree (all side socket) |
| 56 | P Trap/Floor Trap 110mm x 110mm (extra) |
| 57 | For 90 mm i/d pipesElbow 90 degree (all side socket) |
| 58 | Cowls |
| 59 | Collars/ Coupler |
| 60 | Single Y-Junction |
| 61 | Floor Trap (110 x 75) |
| 62 | With90mm i/d outlet deep seal at Ground Floor |
| 63 | With 90mm i/d outlet shallow seal at First Floor |
| 64 | Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. M.S. Holder bats clamps for 100mm i/d H.C.I. pipes |
| 65 | M.S. Holder bats clamps for 90mm i/d H.C.I. pipes |
| 66 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 67 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement,R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal |
| 68 | 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal |
| 69 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.uPVC Pipe 6 Kgf/cm2 50mm i/d |
| 70 | Sub Head-1.2 Internal Water Supply SystemProviding ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B-Class Premium make such as (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete.Note:- (Minor remaining connecting lines as per site conditions)- 15mm i/d |
| 71 | 20mm i/d |
| 72 | 25mm i/d |
| 73 | 32mm i/d |
| 74 | 40mm i/d |
| 75 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm qty same as GI P 15mm i/d to 25 mm |
| 76 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.Through wall 11.43 cm thick |
| 77 | Through wall 22.86 cm thick |
| 78 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.15mm i/d G.I. Union |
| 79 | 20mm i/d G.I. Union |
| 80 | 25mm i/d G.I. Union |
| 81 | 32mm i/d G.I. Union |
| 82 | 40mm i/d G.I. Union |
| 83 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete.25mm i/d Brass Ball valves |
| 84 | 40mm i/d Brass Ball valves |
| 85 | Painting G.I. Pipes and Specials with synthetic enamel Paint in all shades as per I.S.I. specification on existing or new work, two coats paints including cleaning rubbing surface, etc15mm & 20mm i/d G.I. Pipe |
| 86 | 25mm & 32mm i/d G.I. Pipe |
| 87 | 40mm & 50mm i/d G.I. Pipe |
| 88 | Sub Head - 1.3 Sanitary InstallationProviding and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 89 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer in charge ) consisting of 10 ltr. PVC flushing cistern, PVC short bend 32mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer in charge. |
| 90 | Providing and fixing in position Chinaware wall hunged European type water closet with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. Chinaware wall mounted E.W.C without cistern including seat cover complete in all respect. |
| 91 | Providing and fixing in position Metropole flush valve 32mm size dual flow (Concealed body) with exposed shut off provision and round plate complete in all respect. |
| 92 | Providing and fixing jet spray with 2'-6\\" long PVC pipe.With PTMT nut |
| 93 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 94 | Providing and fixing in position vitreous Chinaware white large flat back or angular lipped front urinal 610 mm high of approved make (to the approval of the Engineer-in-charge) (610 mm x 410 mm x 380mm) consisting of C.P. waste 32 mm dia and C.P. brass spreader, complete. |
| 95 | Providing and fixing partition for different type of urinals.19 to 20 mm thick Granite stone partition size 375mm x 750mm |
| 96 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect.Size 49 cm dia (above counter round) qty as per Table Atached |
| 97 | Size 550 mm x 400 mm |
| 98 | Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 99 | Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. |
| 100 | Providing and fixing in position best quality stainless steel sinks with complete fitting. Rectangular Sink with Deluxe Border Single Bowl Overall Size 700 mm x 555 mm x 230 mm |
| 101 | Providing & fixing in position best Indian make PVC flexible tube connection. PVC tube connection of size 15 mm x 375 mm with PTMT nutQty same as WC+WB+Urinal+Steel sink |
| 102 | Providing and fixing PVC waste pipe 32mm complete in all respect.Qty same as WB+Urinal+Steel sink+ Drinking water (-) Bottle trap |
| 103 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 104 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.C.P. brass towel Rails size 15mm dia 610mm long |
| 105 | C.P brass towel ring |
| 106 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.C.P. brass Bib cock long nose/ long body without flange |
| 107 | C.P Brass bib cock without flange |
| 108 | Providing & Fixing in postion stop cock / Angle valve (as approved by the Engineer-in-charge). C.P.brass 15mm Angle valvewithout flange |
| 109 | C.P.brass 15mm Concealed stop cock with flangeFor Jet Spray Connection |
| 110 | Providing & Fixing in position C.P. Brass flange of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 111 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 50mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect. |
| 112 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) |
| 113 | Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. Brass Accessories:C.P. brass toilet paper holder |
| 114 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.C.P. Brass khunti with 3 pegs |
| 115 | Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect. |
| 116 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks 4000 ltr Capacity |
| 117 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball Brass Ball Cock with rod and Plastic Ball 32mm i/d |
| 118 | Brass Ball Cock with rod and Plastic Ball 25mm i/d |
| 119 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.G.I. tank nipple 25mm i/d |
| 120 | G.I. tank nipple 32mm i/d (for flush valve) |
| 121 | Construction of Plateform complete as per specification & as desired by Enginer-in-chargeFor 2000 ltr Water Tank |
| 122 | For 500 & 1000 ltr Water Tank |
| 123 | Providing and fixing in position Grab Bar vertical swing white epoxy coated model WAC-WHT-BG0800 make Jaguar or any equivalent approved make (to the approval of the Engineer-in-charge) fixed in to wall with nylon fastener, brass screws along EWC complete in all respect. |
| 124 | Sub Head-1.4 Flooring and Wall TileBase course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling (Using mechanical mixer for mixing of material) including carrageGround FloorMale, Female & Handicapped Toilet |
| 125 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregateto be laid below the topping. Using machanical mixer for mixing of material includirng carrage |
| 126 | Extra rate for First Floor |
| 127 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 128 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :Ground Floor |
| 129 | First Floor |
| 130 | Extra Rate for First Floor |
| 131 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 300 x 300mm mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.First Floor |
| 132 | Extra Rate for First Floor |
| 133 | Coloured Granite stone tiles 5mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.Ground Floor |
| 134 | First Floor |
| 135 | Extra Rate for First Floor |
| 136 | Extra labour for projected nosing of stair case of any shape and design |
| 137 | Sub Head -1.5 Drinking Water Cooler & Air ConditionsProviding & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.Water Cooler Full Steel Body 60/80 ltr Capacity without Stablizer |
| 138 | Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer |
| 139 | AUTOMATIC VOLTAGE STABLIZER:Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having ain silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet ox of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-Automatic Voltage Stablizer 2 KVA |
| 140 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 141 | Providing, supply & installation of Toshiba make 3/3/2-Star rating with EER>3.5 Fixed Speed Model (Hi-wall Cooling only without installation kit i.e. Copper Pipe) or any other equivalent make Split type Air Conditioner of 1.5 Ton capacity suitable for 230 Volts single phase supply with nature friendly refrigerant R32 or equivelant capable of performing the following functions :- (i) Cooling (ii) Dehumidifying (iii) Air Circulation (iv) Filtering |
| 142 | Providing and fixing Plug Top for fixing with stabilizer complete in all respect. |
| 143 | Providing and installing Automatic Voltage Stabilizer copper winding and having suitable range for input and output of 4 KVA capacity of reputed make along with Ampere Meter, Volt Meter & 3 core wire of 1½ metre length complete in all respect make V-Guard, Liv Guard, Luminous and any other equivalent make. |
| 144 | Providing and fixing refrigerant copper pipe for Split type Air Conditioner including insulation complete suitable for 1.5 tr/2.0 tr Cap Air Conditioner make Total Line or any other equivalent make. |
| 145 | Providing and fixing 15 mm i/d PVC drain pipe with specials for Split type Air Conditioner complete in all respects of approved make. |
| 146 | Providing and fixing PVC 70/76, 3 Core Electrical Wire for Split type Air Conditioner complete in all respects make Finolex, Havels or any other equivelant make. |
| 147 | Providing and fixing PVC 4 Core Power Cable for Split type Air Conditioner of make Finolex/Havels or any other equivelant make complete in all respects. |
| 148 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.for laying Copper Pipe, Electrical Wire and Drain Pipe of Split tyoe Air Conditioners 1.5 / 2.0 Ton capacity and making good the same with Cement / Plaster of Paris (POP) to its original condition complete in all respect |
| 149 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. Size 75 mm x 75 mm |
| 150 | Providing and fixing powder coated angle iron stand heavy duty including grouting for out door unit complete in all respects. |
| 151 | Sub Head-2-Estate Water Supply Estate Water Supply including submersible pumpExcavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.Earth work upto 1.5 m. Depth All classes of soil except rockyFor 50mm pipe line |
| 152 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class,premium make such as (Jindal Hisar) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.50mm i/d |
| 153 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.50mm i/d G.I. Union |
| 154 | Providing, fixing and jointing ISI Marked Gun-Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.50mm i/d Gun Metal peet valve heavy pattern. |
| 155 | Providing GM ferrule as per IS:2692 drilling and tapping cast iron pipe lines of all diametres and screwing in Ferrule and connections complete in all respect.25mm i/d Ferrule heavy duty |
| 156 | Drilling of 500mm dia bore with reverse rotary rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site. Complete in all respects.Drilling of 500mm dia bore with reverse rotary rig upto 150 mtr depth BGL. |
| 157 | Drilling of 500mm dia bore with reverse rotary rig beyond 150 mtr depth upto 300 mtr depth |
| 158 | 1. Erection and dismantling of boring plant including all arrangement for the transportation of the boring equipment to site of work from the store of contractor at site and back are to be made by the contractor at his own cost. All rates should be quoted for supplying the material at site of work. Pits for collection of Water and Water for drilling tube-well be arranged by the firm/ contractor at site at his own cost.2. In case the bore is converted into a tube-well payment of bore shall be made up to the bail plug plus margin (7% of main bore drilling or as actual as per field requirement whichever is less) required for sustaining the main bore. The test bore beyond margin shall be paid at the rate of test bore drilling.Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect. |
| 159 | Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. 200mm Nominal Diameter (Weight 41.6 kg/mtr) 8.00mm Thickness |
| 160 | 150 mm Nominal Diameter (Weight 25.35 kg/mtr) 6.30mm Thickness as per analysis attached |
| 161 | Supplying, fixing and lowering of stainless steel cage type wite wound screen as per , ISI 8110-2000 or latest ISI marked , duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore .150mm internal diameter (slot size 0.75mm) 6.30 mm thickness |
| 162 | Supplying and fixing of bail plug of M.S pipe complete with inverted U-hook attached to the bottom plug Complete in all respects.150mm internal diameter (weight 25.35 kg per metre) 6.30 mm thickness |
| 163 | Providing and fixing M.S. taper / reducer made out of 6 mm thick M.S. sheet complete in all respect.Reducer 200mm x 150 mm |
| 164 | Supplying, fixing and lowering of stainless steel socket as per IS 8110-2000 or latest, ISI marked duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore complete in all respect.150mm Internal Diameter |
| 165 | Supplying, lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S pipe duly welded with suitable grade welding electrode complete in all respects150mm Internal Diameter |
| 166 | Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.200mm Internal Diameter |
| 167 | Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. |
| 168 | Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. |
| 169 | Supplying at site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments .( to be paid as per actual length of pipe) |
| 170 | Earth,Surkhi, Sand, Earth, Fly Ash, Bajri, Ballast, Stone Boulders, Kankar and Building Rubbish, Earth.Supplying of tibba sand /local sand over gravel packing & clayseal, upto G.Level between pipe assembly and bore including carriage . Complete job in all respect (upto 90 mt depth approx.) |
| 171 | Supplying of clay to provide imprevious layer in between pipe assembly and bore above gravel packing including carriage of material. Complete in all respect. (As per BIS 2800-2019) |
| 172 | Provision for Sterilisation of tubewell with sodium hypochorlide/ chlorination of well as per IS code 2800: 2019 complete job. The well shall be disinfected or sterilized as per IS code 2800:2019 or latest, after the development by pump and before the final test. All wells regardless of the use should be sterilized on completion to prevent or retard the growth of corrosion or incrustation fostering organisms. This should be done by introducing chlorine into the water in the well and immediate aquifer surrounding the well .The volume of water in the screen and casing should be estimated and sufficient chlorine added to yield for water with chlorination of 1000 ppm. The solution should be poured into the well and thoroughly mixed in the well by surging with pump. The solution should remain in the well for at leaset 6 hours during which it should be surged at about 2 h interval. After expiration of contact time , the well should be pumped initially back into the well for abour 30 minute and late to waste until there is little of no odour or taste of chlorine in the discharged water . IT has been found that using hypochlorite is of 10% concentration, the requirement of hypochlorite is 10 litre for every cubic meter of water in the well to produce. |
| 173 | Supplying and fixing Mild steel centering guide made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 174 | Testing of water sample for Heavy metal from approved laboratory (Aluminium, selemium, cadmium, chromium, lead, mercury, arsenic, nickel, pesticide etc.) |
| 175 | Development and Stabilizing of the tubewell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.Capacity of Air compressor 550 cfm at 600 PSI |
| 176 | Development and Stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 177 | Pumping MachineryProviding, installing, testing and commissioning of 1 no. Electrically driven pumping set of reputed make , capable of deleviring 125 lpm against a head of 121 mt (7.50 BHP) . Complete in all respects |
| 178 | Supplying lowering of 65 mm dia GI pipe as per IS 1239 including sockets . Complete in all respects |
| 179 | Providing and fixing of submerssible of 2.50 mm ² core cable , complete in all respect (Tubewell to pump room within building complex) |
| 180 | Providing installing, testing and commissioning of electricity , 1 HP to 12.50 HP oil immersed 2 set contactor Complete job including indicators, switches, over load functions , line fault protection , power saving functions as per manufacturer specifications, details & enclosure etc. Complete in all respect including carriage , GST as applicable& installation charges |
| 181 | Providing and installing 80 mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects |
| 182 | Prov. Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator ,suitable for delivering 0.5 to 6 Litres of Bleaching Powder Solution/Sodium Hypo solution per hour under maximum delivery pressure up to 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS. standard specifications. |
| 183 | Rising MainProviding, Stringing out P.V.C. Pipes ISI Marked as per ISI-4985 casting along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including excavation and specials90 mm o/d pipe of 10kg/sqcm from tubewell to node point B |
| 184 | Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)80 mm I/d |
| 185 | Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete @ 3Kg Each (2x3kg = 6kg) |
| 186 | Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (size 0.6m x 0.6m) |
| 187 | Sub Head-3 Estate Sewerage including Septik tank & sockage pitProviding, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.110 mm i/d pipesFor Sewer Line GT to IC 6mtr each 110mmd |
| 188 | 160 mm o/d pipesFor Sewer Line IC to IC and IC to MH 6mtr each |
| 189 | 200 mm o/d pipes |
| 190 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.For depth exceeding 3.0 m but not exceeding 4.5 m B.G.L.For all classes of soil except rocky |
| 191 | Sand Fillling around UPVC PipeFor covering Sewer Line Type II |
| 192 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 63.464 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects.Inside size75x120cm and 120 cm deep |
| 193 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.84 upto 1.80 m increase in depth.Inside size 75x120 cm |
| 194 | Repair of existing Septic Tank size 6.00 Mtr x 4 Mtr. Working depth 2.70 mtr and such as replacment of damaged man hole covers, rendering / replastering of tank, Vent cowls, dislting and cleaning etc. as per actual site conditions complete as per drawing / specification and to the entire satisfaction of Engineer-in-charge. |
| 195 | Repair of existing damaged Soakage pit such as replacment of damaged man hole covers, patch works, dislting and cleaning etc. as per actual site conditions complete as per drawing / specification and to the entire satisfaction of Engineer-in-charge. |
| 196 | Disilting all types of main sewers 760 mm and onwards internal dia by silt clearing machines addopting all safety measures and disposal of silt upto 5km complete in all respects. (CSR item no. 29.70 ) |
| 197 | Disilting of manhole including all safety measures, cost of container T & P and disposal of silt upto 5km complete in all respects. (inlcuding cleaning of rain water haudies & manholes)Depth upto 3 m. |
| 198 | Sub Head-4 Roof Top Rain water Harvesting SystemProviding, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications.200mm o/d pipe of 4 Kgf. / sqcmFor Storm water Line 200mm i/d UPVC pipe as per Detail attached |
| 199 | 160mm o/d pipe of 4 Kgf. / sqcmFor connection of Road gully and water line @ 6mtr. Each per road gully |
| 200 | Excavation in trenches with straight or open cutting in a street, lanes or in a open area with 3D/JCB or excavator including manually dressing bed, trimming sides & slide slope for sewer & manhole to full depth as shown in drawing, including, dressing to correct sections and dewatering, provision for diversion for traffic,protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching etc. fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level removal of surplus spoils from the site of works upto chain (15 m), complete in all respects. For depths not exceeding 3.0 metre B.G.L. For all classes of soil except rocky |
| 201 | Construction of Haudi internal size 0.90mtr x 0.90mtr & 0.90mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x600 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-chargeHaudi Inside size 90x 90 cm and90 cm deep |
| 202 | Construction of Haudi internal size 0.45mtr x 0.45mtr & 0.45mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x450 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-chargeNo. of Haudi @ 5mtr. C/c Distance of Rain water Pipe line Please Enable Macros to View BoQ information |
| 203 | Construction of Haudi internal size 0.45mtr x 0.45mtr & 0.45mtr depth in Brick masonary 1:5, bed 40mm thick cement concrete 1:2:4, 150mm thick base lean concrete 1:8:16, RCC Slab cover 75mm thick inside plaster, cement rendering & RCC man hole cover 450x450 mm clear inside opening rectangular RCC Manhole cover with frame Light Duty complete as per Drawing attached & as desired by the Engineer-in-chargeNo. of Haudi @ 5mtr. C/c Distance of Rain water Pipe line Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysSep 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender