Tender For Addn / Altn And special Repair To Certain Md Accn At Ii Line At Comd Hosp (Ec) Complex Kolkata
Tender Overview
Project Description
Tender for Addn / Altn And special Repair To Certain Md Accn At Ii Line At Comd Hosp (Ec) Complex Kolkata
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Oct-2026 | Corrigendum No. 01 | Other | 12-Oct-2026 |
| 2 | 01-Oct-2026 | Corrigendum No. 01 | BOQ | 12-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | NOTE (Applicable for all items) :-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.2. It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer. |
| 2 | (BLDG Works)Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. (Upto 4th storey) |
| 3 | All as per item No. 1 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 4 | All as per item No. 1 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 5 | Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition). (Upto 4th storey) |
| 6 | All as per item No. 4 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 7 | All as per item No. 4 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 8 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for flat rough finished flat surface of concrete.(Upto 4th storey) |
| 9 | All as per item No. 7 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 10 | All as per item No. 7 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 11 | M&L for Reinforced cement concrete (nominal mix) Type B1 (1:2:4) (20mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. (Upto 4th storey) |
| 12 | All as per item No. 10 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 13 | All as per item No. 10 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 14 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.(Upto 4th storey) |
| 15 | All as per item No. 13 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 16 | All as per item No. 13 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 17 | Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders (Upto 4th storey) |
| 18 | All as per item No. 16 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 19 | All as per item No. 16 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 20 | M&L for brick work with flyash old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. (Upto 4th storey) |
| 21 | All as per item No. 19 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 22 | All as per item No. 19 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 23 | M&L for brick work with flyash old size bricks, straight or curved on plan to any radius in half brick thick walling built in cement mortar (1:4) complete all as specified and directed.(Upto 4th storey) |
| 24 | All as per item No. 22 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 25 | All as per item No. 22 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 26 | Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.(Upto 4th storey) |
| 27 | All as per item No. 25 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 28 | All as per item No. 25 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 29 | M&L for 5 mm thick cement plaster on ceiling in cement mortar (1:3) on concrecte surface , surface finished even and fair with out using extra cement complete all as specified and directed.(Upto 4th storey) |
| 30 | All as per item No. 28 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 31 | All as per item No. 28 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 32 | M&L for 20mm thick cement plaster (in two layer) on fair face of Brick surface with CM (1:4) mixed with WPC finish surface even and smooth with out using extra cement complete all as specified and directed.(Upto 4th storey) |
| 33 | All as per item No. 31 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 34 | All as per item No. 31 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 35 | M&L for 15mm thick cement plaster with CM (1:6) on other than fare face of brick wall finsh even and smooth without using extra cement complete all as directed.(Upto 4th storey) |
| 36 | All as per item No. 34 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 37 | All as per item No. 34 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 38 | Dismantling removing all unsound concrete, plastered material by chipping/chiseling gently at all effected and adjoining areas of concrete etc till sound surface is reached all various locations in building subsequently cleaning the surfaces by hair brush and air blower and removing rubbish off the premises and disposing at the dumping site as approved by local authorities including hoisting assembling and fixing of double layer steel scaffolding to external perimeter of building complete all as specified and directed . (Upto 4th storey) |
| 39 | All as per item No. 37 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 40 | All as per item No. 37 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 41 | Removing of concrete all around reinforcement bar upto 12 mm dia and over from behind the reinforcing bars average 25mm (but not less than 15mm air gap)by manual methods (using wire brushing ,chiseling etc) and applying chloride free rust removing chemical on rusting steel reinforcement bar and removing all rust from steel reinforcement bar by emery paper and cleaning the area thoroughly by water and allow it to dry and totally rust free of reinforcement bar all as complete as per manufacturer's instruction as specified. Make( Rust removing chemical ):- Reebaklens RR of FOSROC or equivalents solutions SIKA/STP. (Upto 4th storey) |
| 42 | All as per item No. 40 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 43 | All as per item No. 40 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 44 | Material , labour and preparation of existing reinforcement surface by brush and application of two component epoxy zincrich primer on existing reinforcement surface of minimum specific gravity 1.75, adhesive bond strength with steel is 1.50N/mm2 and maximum coverage area 5.00 Sqm per litre. complete all as specified. Make- Nitozinc primer of FOSROC or equivalents.(Upto 4th storey) |
| 45 | All as per item No. 43 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 46 | All as per item No. 43 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 47 | Material and labour for introducing new reinforcement bars upto 12 mm dia and over for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified.(upto 4 storied bldg) |
| 48 | All as per item No. 46 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 49 | All as per item No. 46 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 50 | M&L for supply, mixing and placement of micro-concrete cement based prepacked single component chloride free, sulphate free, non-shrink, free flow. elf compacting, ready to use after mixing water in specified proportion of Sika Rep Microconcrete-4 or renderoc-RG of Fosroc in required thickness as per manufacture's instruction and all as directed ,compressive strength (ASTN C 109,cm cube) of 35 MPa at 28 days at various locations in Bldgs including epoxy resin bonding agent Nitobond EP and necessary form work complete all as per manufactures specification.(upto 4 storied bldg) |
| 51 | All as per item No. 49 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 52 | All as per item No. 49 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 53 | M&L for providing and applying at two component structural grade polymer modified reinforcement mortar Fosroc Renderoc S2 or equivalent product of SIKA upto a thickness of 30 mm over a coat of epoxy resin bonding agent Nitobond EP. The cured mortar shall achieve a minimum compressive strength of 12N/mm2 in a day & 45 N/mm2 in 28 days with Flexural strength 8N/mm2 in 28 days Chloride diffusion coefficient shall be Nil after 24 hours when tested by Accelerated electrochemical chloride ion diffusion test method and the depth of carbonation shall be Nil after 24 hours when tested by Accelerated carbonation test. in addition to this percentage of water absorption should be 0.45 after 24 hours in immersion test at various locations in Bldgs complete all as per manufacture's specification.(upto 4 storied bldg) |
| 54 | All as per item No. 52 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 55 | All as per item No. 52 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 56 | Material , labour for applying of high efficiency polymeric resin base film forming curing agent/compound over concrete surface and maximum coverage area 5.00 Sqm per litre as per manufacturers instruction complete all as specified.(upto 4 storied bldg) Make:- Concure LP90 of FOSROC or equivalents solutions SIKA/STP/ Maruti / Choksey chemicals. |
| 57 | All as per item No. 55 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 58 | All as per item No. 55 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 59 | M&L for providing and applying a flexible expansion joint membrane of minimum 150mm wide and 1mm thick, expoband one of FOSROC or equivalent over the prepared joint using a two part epoxy adhesive nitobond PC 40 of Fosroc or equivalent. The minimum tensile strength of the membrane should be more than 12 N/mm2 and elongation at break should be more than 400%. The installation of the membrane should be carried out as per manufactures specification.(Upto 4th storey) |
| 60 | All as per item No. 58 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 61 | All as per item No. 58 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 62 | M & L for providing and inserting mild steel shear key bars/levelling gauges of required length and diameter in reinforced/plain concrete for drilling suitable holes in RCC Slab/ wall/ column/ beams toa depth as directed for anchoring steel reinforcement bars including washing with water inserting lokfix 'E' of Fosroc or equivalent in the holes at various location in Bldgs complete all as per manufactures specification .(Upto 4th storey) |
| 63 | All as per item No. 61 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 64 | All as per item No. 61 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 65 | Material & Labour for applying Anti carbonation coating as per manufacturer's specification of approved brand, manually using brushes on the hardened concrete/plastered surfaces after cleaning the surface and removing all loose particles, deposits etc complete including one coat of primer and two coats coatings as directed. (Upto 4th storey) |
| 66 | All as per item No. 64 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 67 | All as per item No. 64 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 68 | Material & Labour for Carbon Fibre Wrapping - Nitowrap CWS – 450 GSM Providing and carrying out Fosroc make carbon fibre wrapping Nitowrap CWS (450 GSM) - High Performance high strength, carbon fibre system for structural strengthening to R.C. members. Surface Preparation : Proper surface preparation to be carried out including cleaning, removal of loose material, dust etc, executing required repairing like epoxy injection grouting, polymer modified mortar, epoxy touching Putty , rounding off edges of structural members to 25mm etc . Application : Prepared substrate shall be primed with Nitowrap 30 epoxy primer supplied in pack size 4 Lit (Base-4.1 kg and Hardener -0.46 kg) at a coverage of 8-10 m2/litre/coat, allow the primer to cure for 24 hours followed by application of first coat of saturant Nitowrap 410 supplied in pack size 5kg ( Base - 3kg and hardener - 2kg) (having Tensile strength >30 MPa; Elongation > 2.1% ; Fibre strength > 4900 MPa ; Fibre E-Modulus >230 GPa & Flexural Modulus > 1700 MPa when tested as per ASTM D638 Type I and ASTM D 790 & Glass Transition Temperature > 50 °C as per ASTM E 1356) to be carried out at a coverage of 3.5 to 4 m2/lit/Coat at around 250 microns WFT, cutting of Nitowrap CWS (available in standard roll width of 500 mm and roll length of 50 mtr & 100 mtr) in required size and wrap over wet saturant keeping minimum 150 mm overlap, rolling the same using hard roller to impragnent saturant and again applying second coat of saturant using suitable bush or roller etc, completing as per specification and as directed by Engg.-in-charge. Nitowrap CW fabric used shall exhibit the following properties - fiber density of 1.8 g/cc, dry fibre thickness 0.40mm and shall have tensile strength > 4900 MPa ; tensile modulus > 230 GPa and ultimate elongation of 2.1%.The adhesion of the entire system(FRP Sheet, Saturant and primer combined) with concrete shall be > 3.5 MPa with concrete failure as per ASTM D 4541 complete as per specification and as directed. (Upto 4th storey) |
| 69 | All as per item No. 67 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 70 | All as per item No. 67 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 71 | M&L for providing grouting in RCC walls and slabs by drilling holes @300 mm c/c upto half of the wall depth in zigzag manner using a drill machine and fixing a nozzle of 20mm dia, for injecting of epoxy grout till the refusal of injected grout material (grouting operation pressure shall be in between 2 to 4Kg per sq cm) followed by cutting the exposed nozzle so as to make the wall/ slab free from the grouting pipe and to seal the gap with polymer modified mortar.(upto 4 storied bldg) (Make- Fosroc conbextra Ep10(M) or equivalent. |
| 72 | All as per item No. 70 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 73 | All as per item No. 70 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 74 | Taking down chowkhats or frame with shutter (without taking off shutters from the frame) exc 1.5 sqm n.exe 4 sqm each.(Upto 4th storey) |
| 75 | All as per item No. 73 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 76 | All as per item No. 73 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 77 | Taking down rusted steel windows/ventilators/pvc door of any description and size including shutters complete all as specified and as directed.(Upto 4th storey) |
| 78 | All as per item No. 76 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 79 | All as per item No. 76 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 80 | S & F factory made 2nd H/W plain solid straight chowkhats,wrought framed rebated on the solid,rounded or chamfered put together with glue pinned at joints complete all as specified and directed. (Upto 4th storey) |
| 81 | All as per item No. 79 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 82 | All as per item No. 79 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 83 | M&L for factory made 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on one sides with one face covered with decorative face veneer with lipping/frame to match complete all as specified and directed.(Upto 4th storey) |
| 84 | All as per item No. 82 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 85 | All as per item No. 82 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 86 | S&F for Factory made, 2nd class Hard wood of thickness 35 mm, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated with sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as directed. (upto 4 storied bldg) |
| 87 | All as per item No. 85 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 88 | All as per item No. 85 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 89 | S&F for Factory made single extruded WPC(Wood polymer composite) solid door Frames of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60(Suspension grade), calcium carbonate & natural fibres and non-toxic additives fabricated with mitre joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), mimimum compressive strength of 58 N/Sqmm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant & fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as directed. (upto 4 storied bldg) |
| 90 | All as per item No. 88 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 91 | All as per item No. 88 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 92 | S & F for Factory made single extruded WPC(Wood polymer composite) solid flush door shutter of 30mm size comprising of virgin PVC polymer of K value 58-60(Suspension grade), calcium carbonate & natural fibres and non-toxic additives fabricated with mitre joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum density of 650 Kg/cum, screw withdrawal strength of 1800 N(Face) & 900 N (Edge), mimimum compressive strength of 50 N/Sqmm, modulas of elasticity 850 N/sqmm & resistance to spread of flame of class A category with property of termite/borer proof , water/moisture proof & fire retardant & fixing with SS butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per dirns of EIC. (upto 4 storied bldg) |
| 93 | All as per item No. 91 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 94 | All as per item No. 91 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 95 | Supply and fix aluminium anodised (powder coated) Three track sliding window frame with shutters with (2 nos glazed and one wire gauzed shutter) including all necessary joining cleats, hold fast, EPDM gasket, snap beading and locking arrangements fixed with screws to wall etc. complete with glazing and including 5.50 mm thick tinted glass to aluminium frame work using push type gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers as specified with the following section of frame and shutter:- (A) Sections for shutter :- (i) \\"H' section 38 x 20 x 1.50 mm thick. (ii) 'Interlock' section 38 x 20x 1.50 mm thick. (iii) 'Edge & Bottom' section 41 x 20 x 1.50 mm thick.(B) Section for frame :- (i) Top & Sides 92.36 X 29.70X 1.50mm thick. (ii) Bottom 92.36 X 29.70X 1.50mm thick complete all as specified and directed (upto 4 storied bldg). |
| 96 | All as per item No. 94 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 97 | All as per item No. 94 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 98 | M&L for providing chemical emulsion for Post Constructional Antitermite Treatment of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed (upto 04 storey High of building). |
| 99 | All as per item No. 97 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 100 | All as per item No. 97 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 101 | M&L for one coat of synthetic enamelled paint on old decorated wooden surface exc 10cm width or girth including preparation complete all as specified and as directed (upto 04 storey High of building). |
| 102 | All as per item No. 100 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 103 | All as per item No. 100 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 104 | M&L in repair for Cub-boards shutters made with Prelaminated Particle board 18/19 mm thckness , interior grade prelaminated one side with decorative choice lamination, fixed with screws to timber frame work complete in all respect as specified.(upto 4 storied bldg) |
| 105 | All as per item No. 103 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 106 | All as per item No. 103 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 107 | Material & labour preparation of new steel and iron surfaces of any description area exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide and zinc chrome primer, complete in all respect as specified. (upto 04 storey High of building) |
| 108 | All as per item No. 106 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 109 | All as per item No. 106 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 110 | S&F 4.0 mm thick sheet glass ordinary quality, frosted on one side fixed to aluminium frame work n. exc 0.5 Sq. m in each pane complete all as specified & as directed. (upto 4 storied bldg) |
| 111 | All as per item No. 109 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 112 | All as per item No. 109 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 113 | Supply only Integral water proofing compound complete in all respect as specified.(upto 12 storey High of building) |
| 114 | S&F aluminium 6 levers Mortice lock, vertical type, size 100 mm complete all as specified & as directed.(upto 4 storied bldg) |
| 115 | All as per item No. 113 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 116 | All as per item No. 113 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 117 | S&F Stainless steel handles 150mm long, bright polished complete all as specified .(upto 4 storied bldg) |
| 118 | All as per item No. 116 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 119 | All as per item No. 116 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 120 | S&F 40mm dia, cupboard knobs of brass polished fixed with nut, screw and washer of mild steel, bright finished complete all as specified & as directed.(upto 4 storied bldg) |
| 121 | All as per item No. 119 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 122 | All as per item No. 119 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 123 | S&F 300mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bots and sliding bolts of extruded or cast aluminium alloy complete all as specified .(upto 4 storied bldg) |
| 124 | All as per item No. 122 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 125 | All as per item No. 122 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 126 | S&F 200mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bots and sliding bolts of extruded or cast aluminium alloy complete all as specified.(upto 4 storied bldg) |
| 127 | All as per item No. 125 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 128 | All as per item No. 125 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 129 | S&F Stainless steel barrel tower bolts of extruded section with 150 mm long bolt, all as specified .(upto 4 storied bldg) |
| 130 | All as per item No. 128 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 131 | All as per item No. 128 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 132 | S&F 100mm MS Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed (upto 4 storied bldg). |
| 133 | All as per item No. 131 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 134 | All as per item No. 131 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 135 | S&F for Stainless steel wire cloth having 0.36 mm nominal dia of wire and average width of appreature 1.40 mm and fixed with stainless wire staples complete, all as specified .(upto 4 storied bldg) |
| 136 | All as per item No. 134 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 137 | All as per item No. 134 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 138 | S&F in repair Mild steel 200 mm hellical door spring suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed.(upto 4 storied bldg) |
| 139 | All as per item No. 137 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 140 | All as per item No. 137 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 141 | S&F floor door stopper overall length of cover plate 150mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor.(upto 4 storied bldg) |
| 142 | All as per item No. 140 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 143 | All as per item No. 140 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 144 | S&F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), clamps; hold fasts; wall ties; and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.(upto 4 storied bldg) |
| 145 | All as per item No. 143 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 146 | All as per item No. 143 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 147 | S&F 100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.(upto 4 storied bldg) |
| 148 | All as per item No. 146 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 149 | All as per item No. 146 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 150 | S&F magnet catcher fixed in cabnet shutter (one portion) and wooden frame (other portion) with screw complete all as specified and directed.(upto 4 storied bldg) |
| 151 | All as per item No. 149 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 152 | All as per item No. 149 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 153 | Dismantling floor, earth, wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises, and removal of unserviceable tiles out of Mod land where directed by Engr-in-Charge complete all as specified and as directed.(upto 4 storied bldg) |
| 154 | All as per item No. 152 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 155 | All as per item No. 152 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 156 | M&L non-skid joint free ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.06sqm but n.exceeding 0.11 sqm in toilet/bath floor etc.set and jointed with adesive and pointed in epoxy grout with spacers including Screed bed or bedding layer 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed.(upto 4 storied bldg) |
| 157 | All as per item No.155 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 158 | All as per item No. 155 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 159 | M&L for glazed ceramic (coloured) tiles of size 450x300x6-7mm thick as in vertical surface/dado set and jointed in adesive and pointed in white or coloured cement to match over 10mm thick screed bed in CM (1:3) complete all as specified and directed.(upto 4 storied bldg) |
| 160 | All as per item No.158 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 161 | All as per item No. 158 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 162 | M&L non-skid ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.18 sqm but n.exceeding 0.38 sqm in floor etc.set and jointed with adesive and pointed in epoxy grout with spacers over screed bed 15 mm(1:6) complete all as specified & as directed incl .(upto 4 storied bldg) |
| 163 | All as per item No.161 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 164 | All as per item No. 161 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 165 | M&L non-skid ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.18sqm but n.exceeding 0.38 sqm in skirting etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed 10 mm(1:4) complete all as specified & as directed.(upto 4 storied bldg) |
| 166 | All as per item No. 164 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 167 | All as per item No. 164 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 168 | Dismantling of stone slabs and tiles of any description or thickness in floors,aprons etc laid, bedded & pointed in any mortar(upto 4 storied bldg) |
| 169 | All as per item No. 167 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 170 | All as per item No. 167 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 171 | S&F stainless steel Bearing hinges 100mm, cast brass, with Stainless steel hinge pin, bright polished and fixed, typeB-11.(upto 4 storied bldg) |
| 172 | All as per item No. 170 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 173 | All as per item No. 170 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 174 | S&F Brass chromium plated curtain rod brackets complete all as specified and directed.(upto 12 storied bldg) |
| 175 | S&F in repair stainless steel kitchen rack / plate rack of size 36\\"x31\\"x10\\" , made of stainless steel sheet 0.63 mm thick etc complete all as specified and as directed by Engineer-in-charge.(upto 12 storey High of building) |
| 176 | M&L for two coats of synthetic enamel paint over a coat of pink primer area exc.10cm width or girth over new wooden surfaces including preparation of surface complete complete in all respect as spd (upto 04 storey High of building) |
| 177 | All as per item No. 175 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 178 | All as per item No. 175 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 179 | S&F in repair sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes;including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm all as specified and directed.(upto 12 storied bldg) |
| 180 | M & L for Cement concrete in saucer drains Type B1 (1:2:4) (40 mm graded aggregate) slope maintained as per site requirement complete in all respect as specified. |
| 181 | S&F in repair reinforced concrete pipes, class NP3, laid and jointed complete with collars, dia of bore of pipe 200mm with all fittings complete all as specified and directed. |
| 182 | M&L for 100 mm thick PCC type B1 (1:2:4) (20 mm graded stone aggregate) as in flooring,hardstanding or at any place finished even and smooth with using extra cement,complete all as specified and directed. |
| 183 | M&L for 75mm thick PCC (1:3:6), type C2, using 40mm graded stone aggte as in plinth protection / paving, surface finished even & smooth with using extra cement complete as specified and directed. |
| 184 | Demolition of cement concrete (unreinforced) above ground floor n.exe 15cm thickness(below or above ground level) and removing the material outside MOD land complete as specified and directed.(upto 4 storied bldg) |
| 185 | All as per item No. 183 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 186 | All as per item No. 183 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 187 | M&L for 25mm thick cement concrete type B-0, (1:2:4) using 12.5mm graded aggregate complete all as specified.(upto 4 storied bldg) |
| 188 | All as per item No. 186 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 189 | All as per item No. 186 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 190 | M&L for PCC (1:5:10) Type E2 (using 40mm graded crushed stone/brick aggregate) as in filling sunken floor complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building) |
| 191 | All as per item No. 189 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 192 | All as per item No. 189 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 193 | Supply and applying two coats of High performance elastomeric cementitious waterproof coating sandwiched with 45 GSM glass fibre reinforcement on the entire floor and 1.0 m of all walls of all toilets as per following methodology:- Cleaning of exposed concrete surface by mechanical means or by hydro blasting to remove laitance, loose particles, contamination etc. which may hinder bonding. Coving of RCC joints with PCC (1:1.5:3) mixed with Integral Water Proofing compound. Applying one coat of Waterproofing membrane to concrete surfaces followed by application of 45GSM glass fibre on the wet surface. Applying second coat of waterproofing membrane at the right angles to the direction of first coat. Second coat shall be applied after the first coat gets dry. Sprinkling fine aggregate immediately after the application of second coat to get the mechanical key for protective plaster including backfilling of sunken. Curing to Water proofing membrane to be carried out for minimum period of 3 days with ponding complete. The Water Proofing Product Should have Mixed density: 1.68g/cc (brushable consistency). Adhesion to concrete : >1N/mm2. Static crack accommodation: 1mm.( Fosroc/Elantas beck/Kunal conchem) ( Make : SIKA/FOSROC/Hindcon ). (upto 4 storied bldg) |
| 194 | All as per item No. 192 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 195 | All as per item No. 192 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 196 | Bore packing of all the Spouts to be done with grouting admixture mixes with Cement Concrete / Mortar @225 ml per bag of Cement. (upto 4 storied bldg) |
| 197 | All as per item No. 195 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 198 | All as per item No. 195 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 199 | Cutting chases, pinning in. making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth. (upto 12 storey High of building) |
| 200 | Taking up or down 20mm bore steel water tubing and connections,including cleaning for removal to store(GI Pipe) complete all as specified and as directed.(upto 12 storey High of building) |
| 201 | Taking up or down 25mm bore steel water tubing and connections,including cleaning for removal to store(CPVC Pipe) complete all as specified and as directed .(upto 12 storey High of building) |
| 202 | Taking up or down 40mm or 50mm bore steel water tubing and connections,including cleaning for removal to store(CPVC Pipe) complete all as specified and as directed .(upto 12 storey High of building) |
| 203 | Taking down CPVC pipe 50 mm bore with fittings complete all as specified and directed.(upto 12 storey High of building) |
| 204 | Dismantling of 100mm pvc (swr) pipes jointed in cement mortar and taking out of trenches, if required .(upto 12 storey High of building) |
| 205 | S&F 20 mm bore (Outer dia) CPVC pipes of SDR 11and plain CPVC SDR 11 fitting fixed on wall or floor (concealed ), ceiling or laying in floors complete with all fitttings as directed.(upto 12 storey High of building) |
| 206 | S&F in 25 mm bore (Outer dia) CPVC pipes of SDR 13.5 and plain CPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete with all fitttings as directed. (upto 12 storey High of building) |
| 207 | S&F in 40 mm bore (Outer dia) CPVC pipes of SDR 13.5 and plain CPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete with all fitttings as directed. (upto 12 storey High of building) |
| 208 | S&F 50 mm bore (Outer dia) CPVC pipes of SCH-40 and plain UPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete with all fitttings as directed. (upto 12 storey High of building) |
| 209 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls.(upto 12 storey High of building) |
| 210 | S&F 20 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA).(upto 12 storey High of building) |
| 211 | S&F 25 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA).(upto 12 storey High of building) |
| 212 | S&F 20mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA).(upto 12 storey High of building) |
| 213 | S&F 25mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA).(upto 12 storey High of building) |
| 214 | S&F 50 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA).(upto 12 storey High of building) |
| 215 | S&F 50 mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA).(upto 12 storey High of building) |
| 216 | S&F PVC (SWR) bends 110mm dia .(upto 12 storey High of building) |
| 217 | S&F PVC (SWR) junction single, (Single T) equal or unequal 110 mm dia.(upto 12 storey High of building) |
| 218 | S&F PVC (SWR) junction double, (Double T) equal or unequal 110 mm dia.(upto 12 storey High of building) |
| 219 | S&F in repairs vitreous China wash down water closet pan ( padestal pattern) incl PVC seat cover , (excluding fixing bolts, flushing cistern and flush pipe) , including connection to drain ( or outgoing pipe) and to flushing pipe , etc., complete complete all as specified.(upto 12 storey High of building) |
| 220 | S&F in repairs vitreous china wash hand basin, white, flat back, size 550mm x 400mm, exc chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed.(upto 12 storey High of building) |
| 221 | S&F in repairs Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed.(upto 12 storey High of building) |
| 222 | S&F in repair 15mm bore Brass CP angular stop cock type with crutch or butterfly handle complete all as specified and as directed by Engineer-in-Charge.(upto 12 storey High of building) |
| 223 | S & F in repairs 15 mm Dia CP Bib taps,fancy type with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.(upto 12 storey High of building) |
| 224 | S & F in repairs 15 mm Dia CP Bib taps (Two-in-one), fancy type with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed . (upto 12 storey High of building) |
| 225 | S & F in repairs 15 mm Dia CP stop cock(concealed type), with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed . (upto 12 storey High of building) |
| 226 | S&F in repairs 15 mm bore CP pillar taps, with capstan heads, chromium plated, Fancy type screwed down for pipe, high pressure ,complete all as specified and directed.(upto 12 storey High of building) |
| 227 | S & F in repairs 25 mm Dia brass gun metal gate valve , with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed .(upto 12 storey High of building) |
| 228 | S&F in repair CP Health faucet with all necessary fittings . Make : Prayag/Cera/Jaquar or equivalent Make : Prayag/Cera/Jaquar or equivalent.(upto 12 storey High of building) |
| 229 | S&F in repair 600 mm PVC connection pipe 15 mm size with PTMT nut of following length complete all as specified and directed .(upto 12 storey High of building) |
| 230 | S&F in repair 90/110 mm floor trap fixed in floor with grating incl jointing with solvent (1:2:4) cement concrete,complete all as spd and directed.(upto 12 storey High of building) |
| 231 | S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete in all respect as specified and directed.(upto 12 storey High of building) |
| 232 | S&F in repair brass CP Shower roses in repair with or without swivel joints, 125mm size, including fixing to steel pipes or union comlete all as specified and directed.(upto 12 storey High of building) |
| 233 | S&F in repair CP Soap dish, fixed to plugs with chromium plated brass screws comlete all as specified and directed.(upto 12 storey High of building) |
| 234 | S&F in replacement Curtain rails with Decorative type drappery Rod along with all fittings of 25 mm dia except brackets complete all as specfied and directed. (upto 12 storey High of building) |
| 235 | S&F in repair brass CP Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specfied and directed. (upto 12 storey High of building) |
| 236 | S&F in repair PVC valveless, symphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia of make as approved by GE complete all as specified & directed. (upto 12 storey High of building) |
| 237 | S&F UPVC Louvers type ventilator assembled partially with PVC exhaust fan of 200mm sweep and partially fixed with frosted glass of area n.exc 0.5 sqm including all necessary fittings complete all as specified and directed. (upto 4 storied bldg) |
| 238 | All as per item No. 236 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 239 | All as per item No. 236 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 240 | Supply and fixing of rotational moulded polythene water storage tank 1000 litre capacity ISI marked (cylindrical, vertical, double layered with closed top) hoisted and fixed in position including PVC float valve 20mm bore weight not less than 210gms Complete including dismantling of old unserviceable water tank, removing from site including all necessary fittings complete all as specified and directed.(upto 12 storey High of building) |
| 241 | Taking out/Stripping of old Roof treatment membranes/Tar felt incl layer of cement mortar of any type carefully from roof surfaces (without damaging roof ) and incl preparation of old roof surfaces by picking, sweeping, cleaning and washing down with water to remove dust & receive new treatment complete all as specified and directed.(upto 12 storey High of building) |
| 242 | Material and labour for carry out waterproofing treatment to sound, moisture free concrete surface using Nitoproof 600PF - Liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks upto 2 mm. System includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., and application of Nitoproof WB Primer, Water dispersible epoxy primer followed by two coats of Nitoproof 600PF coverage @ 2.0 kg/m2 to achieve 1.5 mm WFT in two coats followed by laying of separation layer of 120 gsm non-woven geotextile layer before carry out protection screed etc. complete including all tools and tackles as per manufacturer’s specification. Nitocote 600PF cured material shall be having crack bridging of 2 mm, Elongation (ASTMD 412) – >600 %, Tensile Strength (ASTM D412) –2.5 N/mm2, Recovery from Elongation (ASTM D412) – 95 %, 85% Solid Content, Tear Resistance (ASTM D624) – 15 Kn/m, Shore A Hardness (ASTM D2240) – 60, Water vapour transmission- 0.6 g/m2/hr, Water Permeability @ 5 Bar (BS EN 12390)-Nil, Service Temperature – -40°C to 70°C, Flash Point > 70 °C, Viscosity-60p, Specific Gravity-1.5. The item rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, shifting of debris outside the site premises, surface preparation, etc. complete as per design, drawing & instructions of EIC. Cost of 120 gsm non-woven geotextile and average 40mm Screed concrete Shall be paid separately.(upto 12 storey High of building) |
| 243 | Supply & Laying Geotextiles of 120 Gsm over the waterproofing coating to avoid damage during screed casting complete as per specification and as directed.(upto 12 storey High of building) |
| 244 | Supply & laying of average 40 mm thick (at RW outlet) protective screed over the waterproof coating at proportion of (1:2:4) admixed with suitable integral waterproofing compound conforming IS 2645:2003 @ 200ml per bag of cement and reinforced with PP fibres with proper slope towards RW pipes. Green stage saw cutting on the screed will be done in panels (3m X 3m) with a groove size of 10mm X 15mm Complete as per specification and as directed.(upto 12 storey High of building) |
| 245 | Dismantling of old plain or corrugated steel sheeting, any gauge, thickness including nanital or similar pattern roof coverings compete all as specified.(upto 4 storied bldg) |
| 246 | All as per item No. 244 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 247 | All as per item No. 244 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 248 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.(upto 4 storied bldg) |
| 249 | All as per item No. 247 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 250 | All as per item No. 247 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 251 | S&F for Pre painted galvalume aluminium zinc coating GI based semi corugated/ Manglore pattern steel sheet 0.50mm thick Hi-Rib colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.(upto 4 storied bldg) |
| 252 | All as per item No. 250 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 253 | All as per item No. 250 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 254 | S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Confirming to IS-1161-1979, Fe 410 Gde-E-250 quality-A complete all as specified and directed.(upto 4 storied bldg) |
| 255 | All as per item No. 253 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 256 | All as per item No. 253 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 257 | S & F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes of Fe 410-W (Gde-E250) quality-A complete all as specified and directed.(upto 4 storied bldg) |
| 258 | All as per item No. 256 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 259 | All as per item No. 256 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 260 | S&F mild steel (galvanized) framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.(upto 4 storied bldg) |
| 261 | All as per item No. 259 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 262 | All as per item No. 259 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 263 | Preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint area tarred exc 0.1 sq. m but n exc 0.5 sq. m each complete all as specified and directed.(upto 4 storied bldg) |
| 264 | All as per item No. 262 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 265 | All as per item No. 262 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 266 | M&L complete removal of old decorated surfaces with sander machine and finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade, two coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed.(upto 4 storied bldg) |
| 267 | All as per item No. 265 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 268 | All as per item No. 265 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 269 | Material & Labour for applying Two coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.(upto 4 storied bldg) |
| 270 | All as per item No. 268 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 271 | All as per item No. 268 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 272 | M&L for preparation of new plastered surfaces and applying two coat of acrylic distemper on ceiling complete in all respect as specified.(upto 4 storied bldg) |
| 273 | All as per item No. 271 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 274 | All as per item No. 271 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 275 | M&L preparation of old surface and applying one coats of acrylic distemper on ceiling to match with the new one all complete in all respect as specified.(upto 4 storied bldg) |
| 276 | All as per item No. 274 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 277 | All as per item No. 274 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 278 | M&L for preparation of newly plastered wall surface two coats of oil bound distemper over a coat of primer on complete all as specified and directed.(upto 4 storied bldg) |
| 279 | All as per item No. 277 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 280 | All as per item No. 277 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 281 | M&L preparation of old decorated surface by complete removal of existing treatment with sander machine and applying two coats of oil emulsion distemper over a coat of primer on wall complete in all respect as specified.(upto 4 storied bldg) |
| 282 | All as per item No. 280 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 283 | All as per item No. 280 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 284 | M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete as specified and directed.(upto 4 storied bldg) |
| 285 | All as per item No. 283 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 286 | All as per item No. 283 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 287 | Material and labour for Providing cement concrete type B-1 (1:2:4) (using 12.5 mm graded stone aggregate) as in benching concrete,coping etc complete all as specified and directed. |
| 288 | M&L for Machine cut kota stone slab flooring in stair case including riser and tread with single piece slab of 20-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete, including over 20 mm thick screed bed in CM (1:6) all as specified and directed.(upto 4 storied bldg) |
| 289 | All as per item No. 287 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 290 | All as per item No. 287 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 291 | Mirror polishing on kota stone/stone work where-ever required to give high gloss finish complete.(upto 4 storied bldg) |
| 292 | All as per item No. 290 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 293 | All as per item No. 290 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 294 | S&F Continuous (Piano) hinges, mild steel, bright finished or electro galvanized, width of flaps (When open) 30 mm at any storey of building complete all as specified & as directed. (upto 04 storey High of building) |
| 295 | All as per item No. 293 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 296 | All as per item No. 293 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 297 | S&F 100mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.(upto 04 storey High of building) |
| 298 | All as per item No. 296 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 299 | All as per item No. 296 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 300 | S&F Hasp and staple, safety type,brass with mild steel hinge pin including bolt to hinge plate and fixed with screws at any storey of building complete all as specified & as directed(upto 04 storey High of building). |
| 301 | All as per item No. 299 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 302 | All as per item No. 299 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 303 | M&L for 18-20 mm thick black granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, indow-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.(upto 4 storied bldg) |
| 304 | All as per item No. 302 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 305 | All as per item No. 302 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 306 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situation.(upto 4 storied bldg) |
| 307 | All as per item No. 305 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 308 | All as per item No. 305 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 309 | M&L for screed bed or bedding layer of mortar 20 mm thick in CM (1:6) for laying floor finishes.(upto 4 storied bldg) |
| 310 | All as per item No. 308 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 311 | All as per item No. 308 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 312 | S&F in repairs Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.(Make:-Cera Cat-2024, Cat No-F1018402 or Equivalent) (upto 4 storey bldg). |
| 313 | All as per item No. 311 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 314 | All as per item No. 311 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 315 | Dismantling of roof tiling including cement mortar bedding and remove the tiles/rubbish outside the MOD land, complete all as specified and as directed. (upto 12 storied bldg). |
| 316 | Demolition of cement concrete on roof n.exe 15cm thickness and remove the malba/rubbish outside the MOD land, complete all as specified and as directed. (upto 12 storied bldg). |
| 317 | S&F 16 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA).(upto 12 storey High of building) |
| 318 | S&F 16 mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA).(upto 12 storey High of building) |
| 319 | Dismantling of 75 mm pvc (swr) pipes jointed in cement mortar and taking out of trenches, if required .(upto 12 storey High of building) |
| 320 | S&F 75mm bore PVC(SWR) pipe single socket in any length rubber ring joints complete in all respect as specified. |
| 321 | S&F 75mm bore PVC(SWR) pipe bend single socket complete in all respect as specified. |
| 322 | S&F PVC (SWR) 75 mm bore junction single, (Single T) equal or unequal complete in all respect as specified. |
| 323 | S&F for 75mm dia PVC (SWR) vent cowl any radius complete all as specified and directed. |
| 324 | (Spcl Item)M&L for 2mm thick wall care putty on internal and external wall including rubbing with sand paper/sander machine to achieve a smooth surface & sharp straight edges etc. complete all as specified & as directed (upto 4 storey bldg). |
| 325 | All as per item No. 323 above but from 5 storied to 8 storied of building complete all as specified and as directed. |
| 326 | All as per item No. 323 above but from 9 storied to 12 storied of building complete all as specified and as directed. |
| 327 | (Road, Path, Culvert etc)M&L for precast cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) kerbs stone rounded or chamfered on edges as in edge of path, hard standing built in cement mortar (1:6) complete all as specified and as directed. |
| 328 | M&L 60 mm thick machine pressed precast interlocking paver block of M-35 Grade any shape and size with grey cement and pigment confirming to IS 15658-2006 complete all as spd and directed. |
| 329 | Material and labour for pre-polished cement concrete designed coloured chequered tiles glossy finish of area n exc 0.16 sqm as in floor set and jointed in neat cement slurry with grey pigment cement and pigments to match the shade of the tiles and laid over and including 15 mm thick screed bed in cement mortar (1:6) over 40mm PCC (1:2:4) type B-0, complete all as specified and as directed. |
| 330 | M&L PCC (1:4:8) type D-2 (using 40mm graded aggregate) as in sub base complete all as specified and as directed. |
| 331 | Hard core of gauge in exc. 63mm broken stone boulders deposited and spred and leveled in layers in.exc. 15mm thick complete all as specified and directed. |
| 332 | M&L sand filling under floor or in floor or paving, laid in including watering and consolidation true surface for laying paver block complete all as specified and as directed. |
| 333 | (Internal Electrification)Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.all as specified and directed by Engr-in- Charge |
| 334 | Material and labour in replacement for point wiring with 1.5 sqmm PVC insulated FRLSH unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through non metallic rigid PVC heavy duty of size 25mm dia having wall thickness not less than 1.8mm with all accessories and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick bakelite sheet cover or for fixing of switch/sockets/regulators etc as per site requirement after and including taking down of old existing point wiring including fitting and making good the distrubed surfaces as per the existing complete all as specified and as directed. Note:- Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc. |
| 335 | All as per item No 333 here-in-before but for one light point / one fan Point /one Bell Point controlled by one way switch complete as specified and directed. |
| 336 | All as per item No 333 here-in-before but for one light point controlled by two way switch with 1.5 sqmm cable complete as specified and directed. |
| 337 | All as per item No 333 here-in-before but for 3 pin 6 Amps socket outlet on the same board with 1.5 sqmm cable complete as specified and directed. |
| 338 | All as per item No 333 here-in-before but for 3 pin 6 Amps switch socket combination on the Independent board with 1.5 sqmm cable complete as specified and directed. |
| 339 | All as per item No 333 here-in-before but for switch socket combination 2 in 1,3 pin 5/15 Amp on independent board with 2.5 Sqmm PVC unsheathed copper cable and 2.5 sqmm copper conductor cable as earth continuity conductor complete as directed.( 264+88) for Power Point & Geyser Point |
| 340 | M & L in replacement for switch socket combination 2 in 1, 5 pin 5 Amps, 240 V Flush type, all as specified. |
| 341 | Supply and fix in replacement switch socket combination 2 in 1,5/15 Amps, 230 Volts, flush type universal complete all as specified and as directed by the Engr-in-Charge. |
| 342 | S & F in replacement socket outlet 2 in 1, 5 pin 5 Amp,230 Volts flush type. |
| 343 | Supply and fixing in replacement switch piano, flush type 5 Amps 230 Volt single pole, one way complete all as specified and as directed by the Engr-in-Charge. |
| 344 | Supply and fixing in replacement switch piano, flush type 5 Amps 230 Volt single pole, two way complete all as specified and as directed by the Engr-in-Charge. |
| 345 | Supply and fixing in replacement of 16 Amp switch flush type 230 volts single pole white/ivory finish all as specified & directed. |
| 346 | Supply and fixing in replacement of socket multipurpose flush type 2 in 1 type (3 and 3 pin ) 5/16 Amps, 230V, AC white / ivory finish all as specified and directed. |
| 347 | Supply and fixing in replacement ceiling rose surface bakelite three terminal 65 x 50mm, PVC/Polycarbonate,isolated body complete all as specified and as directed by the Engr-in-Charge. |
| 348 | S&F in replacement bell push, flush button single pole 6 amps 230 volts AC with polycarbonate body all as specified and directed by Engineer-in-Charge. |
| 349 | Supply & Fixing in replacement Bell multi music type, complete all as specified and as directed by Engineer-in-Charge. |
| 350 | S&F in replacement fan regulator electronic, flush type humming with (step type) polycarbonate body suitable to control speed of fan from 0 to 100% and connecting electrically all as specified and directed by Engineer-in-Charge. |
| 351 | Supply and fixing of Lamp holder, PVC/Polycarbonate type with cord grip cap suitable forpendant fittings, complete all as specified and directed. |
| 352 | Supply & fixing main stream battens fitting LED 20/22 watt tube 4 feet long fixing on PVC/wooden round block complete with all accessories, prewired and flexible wire twin core from ceiling rose to terminal block all as directed. |
| 353 | Supply & fixing main stream battens fitting LED 10 watt tube 2 feet long fixing on PVC/wooden round block complete with all accessories, prewired and flexible wire twin core from ceiling rose to terminal block all as directed. |
| 354 | Supply & fixing LED bulb, B22 base, 9/10 watt, lumen output> 90Lum/W, CRI> 70, 5700-6500K Color temp, PF>0.9, THD< 20% suitable for lamp holder complete all as specified and directed |
| 355 | Supply & fixing Surface mounted LED bulk head light fitting 9/10W, IP66, Iumen output >65 lum/watt, color temp 5700- 6500K,CRI>70, THD<20%, PF>0.9, operating voltage 220-240 V in high pressure die cast aluminum housing in polycarbonate cover with clear prismatic diffuser and lamp holders etc complete making connections, complete all as specified & directed. |
| 356 | Supply and fix LED building security light 30 Watt IP 65 along with fixing accessories on wall/ pole complete all as directed. Make:Crompton cat no-ERP-427-30-57-HL2-LM-NBK Or Equivalent Havells /C&S /Jaquar |
| 357 | Supply laying and testing of cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electic power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16.0 Sqmm 4.0 core complete after taking down old XLPE cable of any size all as specified and directed.(Note: Used for BBT to TPN Connection.) |
| 358 | Material and labour for sub-main wiring (concealed type) for main DB's to sub DB's with PVC (FR-LSH) insulated & unsheathed two runs of 6.0 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 6.0 sq mm PVC (FRLSH) insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, including drawn through sutaible size of casing caping/PVC rigid conduit 25mm dia and having thickness 1.6 mm including accessories carefully and taken down old existing aluminium/copper sub main wiring with accessories complete all as directed by the Engr-in-Charge. Make :- RR Kable/Havells/Polycab. Note : Three runs of 6.0 sqmm cable and one RM of PVC Conduit shall constitute one unit. |
| 359 | All as per Item No 357 here in before but of size 4.0 Sqmm complete all as per specified and as directed.(For AC Point) |
| 360 | Supply and Fixing MCB, single pole, 240 Volts, of capacity (6-32 Amps) 'C' series breaking capacity 10 KA. Make :-IndoAsian/ Havells/L&T/Legrand. |
| 361 | Supply and fixing MCB SPN, 40 to 63 Amps, 240 Volts , breaking capacity 10KA complete all as directed. Make :- IndoAsian/Havells/L&T/Legrand. |
| 362 | Supply and fixing MCB TPN 63 Amps, 415 volts, , breaking capacity 10KA complete all as directed. Make :- IndoAsian/Havells/L&T/Legrand. |
| 363 | Supply and fixing as MCB DB SPN (double door) 12 ways including copper bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge. Make :- IndoAsian/Havells/L&T/Legrand. |
| 364 | Supply and fixing MCB DB TPN (double door) 4 Ways including copper bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall all as specified and directed by the Engr-in-Charge. Make :- IndoAsian/Havells/L&T/Legrand. |
| 365 | M&L for taking out unserviceable DBs of any type / capacity incl MCBs for fixing of new or old all as directed |
| 366 | Taking down geyser , any type and Refixing complete all as specified and directed. |
| 367 | Taking down Ceiling/Exhaust fan, sealing cable end, dismantling blades and removing fan and blades deposit to store for safe custody and refixing at the same position after repairing, greasing, changing of bearing/capacitor if required, complete all as specified and directed. |
| 368 | Supply and fix power unit 32 Amps including socket 25 AMp ,06 module metal box box for mounting of power unit complete as specified and directed. |
| 369 | Earthing complete with galvanised earth plate electrode 600x600x6.0mm thick, buried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected with galvanised iron earth strip 32x6mm by means of bolts, nuts, check nuts and washer of galvanised iron or steel complete with 40 mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test piont etc. in and including light frade GI protection pipe 40mm bore up to 5m lenght for drawing in earth lead wire , all as shown in electrical plate No.3 of SSR Part-1 complete with necessary earth work in any type of soil, removal to a distance not exc. 50m, testing on completion complete all as specified & directed. |
| 370 | Supply and fix ,installtion and commissing Sandwich type Bus duct with Aluminum alloy conductors treated (Including dismalnting taking down )over the entire surface with 5 galvanic processes(copper plating +tinplating) through out the conductors.The conductors are insulated and separated from each other by a double layer of polyester film (0,20mm)classF(155°C), aV1self-extinguishing insulating material, non-desiccant,with highdielectric strength and in compliancewith the in candescent wire test as per IEC 60695-2-1(CEI50.11). Reference standard :IEC61439-6 Aluminum Feeder busway (3L+N+PE) Protection degree: IP54 for Indoor and Outdoor with climate screen Rated Voltage: 1000V Impulse Voltage:12kVPower Frequency with stand Voltage:2.2kV Salt spray test:1500HrsMechanical Strength:IK10, Length in R/M-802. SCPAL630A4CPE1FLGFAB (4CIP55) SCP 630A -02 Nos3. LocallyFabricated(withoutMCCB) SCP 630A -02 Nos4. 1000AENDCOVER (NA) Accessories_SCP 630A -02 Nos5. VERTL.HANGERW/BRACKT&SPRING (A(BKT+SPR)) Accessories_SCP 630A -22 Nos6. PIB160A+ROH+SUITABLEFORMCCB(withoutMCCB) TOB_SCP 63A -22 Nos (Inculding Taking down Bus Bar System)(NOTE-: Four Runs of Aluminum Bus Bar Sandwich type 630A, 35KA Shall constitute 1 R/M) |
| 371 | (Lightening Protection)Supply and fixing air termination, single pointed, aluminium rod 12mm dia and 300mm long with all accessories required for fixing/mounting on 40mm GI pipe light grade including taking down old unserviceable and make good the disturbed surface complete all as specified and as directed. |
| 372 | Supply & fixing single galvanised strip of size 32x6 mm galvanised iron in proper positon saddles on porcelain insulator and fixing screws for roof conductors and down conducrors from top to the building ring point to the test points of the building as required after and including taking out old unsv and make good the disturbed surface complete all as specified and directed. |
| 373 | Supply & fixing single aluminium strip of size 25 x 3 mm aluminium strip in proper positon saddles on porcelain insulator and fixing screws for ring conductors from top to the building air termination point to the ring conductor of the building as required after and including taking out old unsv and make good the disturbed surface complete all as specified and directed. |
| 374 | Taking down old U/s GI strip of any size and making good surfaces all complete as specified and directed by engg-in-charge |
| 375 | Supply & fixing for Test point box of suitable size including terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw and connected with earthing strip including taking out old unsv and make good the disturbed surface complete all as per directed. |
| 376 | Materials and labour for earthing as complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender