Drinking Water Supply and Sanitation Boards / Undertakings / PSU Closing in 6 days TDR #57516657

Tender For Improvement Of Internal And External Electrification Of Civil Office Building And Water Emergency Complex At C Lal Okhla Phase-2 Under Tughlakabad Constituency Ac-52.

Issued by Boards / Undertakings / PSU · Delhi, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Sep 2026
6 days left
EMD
27300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Improvement Of Internal And External Electrification Of Civil Office Building And Water Emergency Complex At C Lal Okhla Phase-2 Under Tughlakabad Constituency Ac-52. , S/O 20 W Led Batten Light. Make: Bajaj/ Havells/Crompton Djb Sor (E&M)2025- 19.1.2 , S/O 70 W Led Street Light. Make: Bajaj/ Havells/ Cromptondjb Sor (E&M)2025-19.10.6 , S/O 300 Mm Size Exhaust Fan. Make: Havells/Orient/ Crompton Djb Sor (E&M)2025-20.2.1 , S/O 450 Mm Size Air Circulators. Make: Havells/Orient/ Cromptondjb Sor (E&M)2025-20.3.1 , S/O Led Recess Light Fitting And Frame 600Mm X 600Mm (2Ft X 2 Ft.) (N.S) Wit Het Diffuser, Recess Mounting 36/40W. Make:- Phillipsdjb Sor (E&M)2025-19.9.1 , S/O 1200 Mm Size Ceiling Fan. Make: Havells/Orient/ Crompton Djb Sor (E&M)2025-20.1.2 , S/O Pvc/Xlpe Insulated (Heavy Duty) Electrical Cable For Working Voltage Up To And Including 1100 Volts To Is:1554 (Part-I) 1988/7098 (Part-I) With Aluminum Conductor- Isi Marked Power Cable- Aluminum For Size 10 Sq.Mm 2 Core Armored Cable. Make: Havells/ Grandley/ Gloster / Any Djb Approved Make. , Wiring For Light Point / Fan Point/ Exhaust Fan / Call Bell Point / With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Piano Type Switch, Phenol Laminated Sheet, Suitable Size Ms Box And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Requireddjb Sor Code E&M. 1.10.1 , Wiring For Circuit/ Sub Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wiredjb Sor Code E&M 1.14.2 , Wiring For Circuit/ Sub Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 4 Sq. Mm + 1 X 4 Sq. Mmearth Wiredjb Sor Code E&M 1.14.3 , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Requireddjb Sor Code E&M.1.32 , Laying And Fixing Of One Number Pvc Insulated And Pvc , Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required.Djb Sor Code E&M 10.7.1 , Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. Dsr (E&M)2022, Item Code-1.44 , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. Dsr (E&M)2022, Item Code-1.50.1 , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Poledjb Sor Code E&M 2.10.1 , Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 12 Way , Double Door Djb Sor Code E&M 2022 2.3.3 , Supply And Fixing Of Following Ways Surface/ Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protection Duly Power Painted, Inclusive Of 200 A Tinneddjb Sor Code E&M 2022 2.3.3 , Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. 63 annual periodical maintenance Four Poledjb Sor Code E&M 2.13.2 , Supplying And Fixing Following Double Pole 240V Rating, , Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. 63 annual periodical maintenance Djb Sor Code E&M 2.12.2 , Supplying And Fixing Of 32 Mm Dia X 2.00-Meter-Long G.I. Pipe (Medium Class) Bracket For Mounting Of Fluorescent / Hpmv / Hpsv Street Light Fitting On Pole Including Bending The Pipe To The Required Shape, 2 Nos. 40 Mm X 3 Mm Flat Iron Clamps With Nuts, Bolts And Washer, Painting The Flat Iron With Primer And Finish Paint Etc. As Required.Djb Sor Code E&M 13.34 , Earthing With G.I. Earth Pipe 4.5-Meter-Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Requireddjb Sor Code E&M.5.2 , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Requireddjb Sor Code E&M.5.16

BOQ

Name of Work:- Improvement of Internal and External electrification of Civil Office Building and Water Emergency Complex at C Lal Okhla Phase-2 under Tughlakabad constituency AC-52.
Sl. No. Item Description
1S/o 20 W LED Batten light. Make: Bajaj/ Havells/Crompton DJB SOR (E&M)2025- 19.1.2
2S/o 70 W LED street light. Make: Bajaj/ Havells/ CromptonDJB SOR (E&M)2025-19.10.6
3S/o 300 mm size Exhaust Fan. Make: Havells/Orient/ Crompton DJB SOR (E&M)2025-20.2.1
4S/o 450 mm size Air circulators. Make: Havells/Orient/ CromptonDJB SOR (E&M)2025-20.3.1
5S/o Led Recess Light fitting and frame 600mm X 600mm (2Ft x 2 Ft.) (N.S) wit HET diffuser, Recess Mounting 36/40W. Make:- PhillipsDJB SOR (E&M)2025-19.9.1
6S/o 1200 mm size Ceiling Fan. Make: Havells/Orient/ Crompton DJB SOR (E&M)2025-20.1.2
7S/o PVC/XLPE insulated (heavy Duty) Electrical Cable for working voltage up to and including 1100 volts to IS:1554 (part-I) 1988/7098 (part-I) with aluminum conductor- ISI marked power cable- aluminum for size 10 Sq.mm 2 core Armored cable. Make: Havells/ Grandley/ Gloster / Any DJB approved make.
8Wiring for light point / fan point/ exhaust fan / call bell point / with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenol laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as requiredDJB SOR CODE E&M. 1.10.1
9Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wireDJB SOR CODE E&M 1.14.2
10Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mmearth wireDJB SOR CODE E&M 1.14.3
11Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as requiredDJB SOR CODE E&M.1.32
12Laying and fixing of one number PVC insulated and PVC
13Sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.DJB SOR CODE E&M 10.7.1
14Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. DSR (E&M)2022, Item code-1.44
15Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. DSR (E&M)2022, Item code-1.50.1
16Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single poleDJB SOR CODE E&M 2.10.1
17Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door DJB SOR CODE E&M 2022 2.3.3
18Supply and fixing of following ways surface/ recess mounting, vertical type, 415 v, TPN MCB distribution board of sheet steel, dust protection duly power painted, inclusive of 200 A TinnedDJB SOR CODE E&M 2022 2.3.3
19Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 63 Amp Four poleDJB SOR CODE E&M 2.13.2
20Supplying and fixing following Double Pole 240V rating, , isolator in the existing MCB DB complete with connections, testing and commissioning etc. 63 Amp DJB SOR CODE E&M 2.12.2
21Supplying and fixing of 32 mm dia X 2.00-meter-long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 Nos. 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.DJB SOR CODE E&M 13.34
22Earthing with G.I. earth pipe 4.5-meter-long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as requiredDJB SOR CODE E&M.5.2
23Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as requiredDJB SOR CODE E&M.5.16 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57516657
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 21-09-2026
Authority
Authority Name Delhi Jal Board
Work Description Tender for Improvement Of Internal And External Electrification Of Civil Office Building And Water Emergency Complex At C Lal Okhla Phase-2 Under Tughlakabad Constituency Ac-52. , S/O 20 W Led Batten Light. Make: Bajaj/ Havells/Crompton Djb Sor (E&M)2025- 19.1.2 , S/O 70 W Led Street Light. Make: Bajaj/ Havells/ Cromptondjb Sor (E&M)2025-19.10.6 , S/O 300 Mm Size Exhaust Fan. Make: Havells/Orient/ Crompton Djb Sor (E&M)2025-20.2.1 , S/O 450 Mm Size Air Circulators. Make: Havells/Orient/ Cromptondjb Sor (E&M)2025-20.3.1 , S/O Led Recess Light Fitting And Frame 600Mm X 600Mm (2Ft X 2 Ft.) (N.S) Wit Het Diffuser, Recess Mounting 36/40W. Make:- Phillipsdjb Sor (E&M)2025-19.9.1 , S/O 1200 Mm Size Ceiling Fan. Make: Havells/Orient/ Crompton Djb Sor (E&M)2025-20.1.2 , S/O Pvc/Xlpe Insulated (Heavy Duty) Electrical Cable For Working Voltage Up To And Including 1100 Volts To Is:1554 (Part-I) 1988/7098 (Part-I) With Aluminum Conductor- Isi Marked Power Cable- Aluminum For Size 10 Sq.Mm 2 Core Armored Cable. Make: Havells/ Grandley/ Gloster / Any Djb Approved Make. , Wiring For Light Point / Fan Point/ Exhaust Fan / Call Bell Point / With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Piano Type Switch, Phenol Laminated Sheet, Suitable Size Ms Box And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Requireddjb Sor Code E&M. 1.10.1 , Wiring For Circuit/ Sub Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wiredjb Sor Code E&M 1.14.2 , Wiring For Circuit/ Sub Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. 2 X 4 Sq. Mm + 1 X 4 Sq. Mmearth Wiredjb Sor Code E&M 1.14.3 , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 A Modular Socket Outlet And 15/16 A Modular Switch, Connections Etc. As Requireddjb Sor Code E&M.1.32 , Laying And Fixing Of One Number Pvc Insulated And Pvc , Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required.Djb Sor Code E&M 10.7.1 , Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Up To 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. Dsr (E&M)2022, Item Code-1.44 , Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. Dsr (E&M)2022, Item Code-1.50.1 , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Poledjb Sor Code E&M 2.10.1 , Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 12 Way , Double Door Djb Sor Code E&M 2022 2.3.3 , Supply And Fixing Of Following Ways Surface/ Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protection Duly Power Painted, Inclusive Of 200 A Tinneddjb Sor Code E&M 2022 2.3.3 , Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. 63 annual periodical maintenance Four Poledjb Sor Code E&M 2.13.2 , Supplying And Fixing Following Double Pole 240V Rating, , Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. 63 annual periodical maintenance Djb Sor Code E&M 2.12.2 , Supplying And Fixing Of 32 Mm Dia X 2.00-Meter-Long G.I. Pipe (Medium Class) Bracket For Mounting Of Fluorescent / Hpmv / Hpsv Street Light Fitting On Pole Including Bending The Pipe To The Required Shape, 2 Nos. 40 Mm X 3 Mm Flat Iron Clamps With Nuts, Bolts And Washer, Painting The Flat Iron With Primer And Finish Paint Etc. As Required.Djb Sor Code E&M 13.34 , Earthing With G.I. Earth Pipe 4.5-Meter-Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal/ Coke And Salt As Requireddjb Sor Code E&M.5.2 , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing As Requireddjb Sor Code E&M.5.16
Basic Detail
Tender No NIT No.4/EE(EM)M-16/(26-27)
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 14 Sep 2026
Submission Date 21 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 27300
Exemption Available
Document List
5f6851bb-41de-409d-844d-457b8fd4543b.html
BOQ_397953.xls
Tendernotice_1 (20).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

5f6851bb-41de-409d-844d-457b8fd4543b.html

xls

BOQ_397953.xls

pdf

Tendernotice_1 (20).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders