Rural Development Local Bodies Closing in 13 days TDR #57516617

Tender For Proposed Devolopment Plan Of Gd Block Ground Under Bidhanagar Municipal Corporation

Issued by Local Bodies · 24 Paraganas North, West Bengal
Tender Value
3.07 Crore
Estimated cost
Bid Submission
29 Sep 2026
13 days left
EMD
6.15 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Proposed Devolopment Plan Of Gd Block Ground Under Bidhanagar Municipal Corporation

BOQ

Name of Work:- PROPOSED DEVOLOPMENT PLAN OF GD BLOCK GROUND UNDER BIDHANAGAR MUNICIPAL CORPORATION
Sl. No. Item Description
1Seating Gallery (27.8 m x 3 m) 1st
2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
4Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
5Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
61:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
7Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
8Fabrication and manufacturing of solid precast concrete element with provisions of shearkeys, connecting loops, dowel tubes and proper lifting accessories for walls, beams, slabs, stairs, column etc, of various thickness, shape and size of different concrete grades manufactured in controlled factory environment with approved methodology including moulds (Pallet system, Tilts form, table moulds, battery moulds, vertical moulds, beam moulds, column moulds, staircase moulds, Facade mould, etc.), mixing, transporting and placing of concrete, vibrating, curing, finishing, making necessary cutout/holes of required sizes for services, yard handling & stacking all complete as per IS 11447:1985 and as per approved shop drawings and design mix as per the direction of Engineer-in-Charge (Cost of reinforcement, Mechanical, Electrical and Plumbing inserts will be paid separately).Note: Excess/less cement over the specified cement content used as per design mix is payable/recoverable separately)Concrete grade M-35 (Cement content 370 kgs)
9Thermo-Mechanically Treated bars of grade Fe-500D or more.
10Centering and shuttering including strutting, propping etc. and removal of form for
11Columns, Pillars, Piers, Abutments, Posts and Struts
12Lintels, beams, plinth beams, girders, bressumers and cantilevers
13Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
14Structural steel work in single section, fixed with or without connecting plate, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
15Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc.,including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer, including welding and bolted with special shaped washers etc. complete.
16Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
17Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
18Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
19Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
2075 mm bend
2175 mm Shoe
22Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
23Seating Gallery (27.8 m x 3 m) 2nd
24Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
26Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
27Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
281:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
29Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
30Fabrication and manufacturing of solid precast concrete element with provisions of shearkeys, connecting loops, dowel tubes and proper lifting accessories for walls, beams, slabs, stairs, column etc, of various thickness, shape and size of different concrete grades manufactured in controlled factory environment with approved methodology including moulds (Pallet system, Tilts form, table moulds, battery moulds, vertical moulds, beam moulds, column moulds, staircase moulds, Facade mould, etc.), mixing, transporting and placing of concrete, vibrating, curing, finishing, making necessary cutout/holes of required sizes for services, yard handling & stacking all complete as per IS 11447:1985 and as per approved shop drawings and design mix as per the direction of Engineer-in-Charge (Cost of reinforcement, Mechanical, Electrical and Plumbing inserts will be paid separately).Note: Excess/less cement over the specified cement content used as per design mix is payable/recoverable separately)Concrete grade M-35 (Cement content 370 kgs)
31Thermo-Mechanically Treated bars of grade Fe-500D or more.
32Centering and shuttering including strutting, propping etc. and removal of form for
33Columns, Pillars, Piers, Abutments, Posts and Struts
34Lintels, beams, plinth beams, girders, bressumers and cantilevers
35Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
36Structural steel work in single section, fixed with or without connecting plate, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
37Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc.,including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer, including welding and bolted with special shaped washers etc. complete.
38Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
39Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
40Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
41Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
4275 mm bend
4375 mm Shoe
44Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
45Seating Gallery (40 m x 6 m)
46Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
47Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
48Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
49Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
501:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
51Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
52Fabrication and manufacturing of solid precast concrete element with provisions of shearkeys, connecting loops, dowel tubes and proper lifting accessories for walls, beams, slabs, stairs, column etc, of various thickness, shape and size of different concrete grades manufactured in controlled factory environment with approved methodology including moulds (Pallet system, Tilts form, table moulds, battery moulds, vertical moulds, beam moulds, column moulds, staircase moulds, Facade mould, etc.), mixing, transporting and placing of concrete, vibrating, curing, finishing, making necessary cutout/holes of required sizes for services, yard handling & stacking all complete as per IS 11447:1985 and as per approved shop drawings and design mix as per the direction of Engineer-in-Charge (Cost of reinforcement, Mechanical, Electrical and Plumbing inserts will be paid separately).Note: Excess/less cement over the specified cement content used as per design mix is payable/recoverable separately)Concrete grade M-35 (Cement content 370 kgs)
53Thermo-Mechanically Treated bars of grade Fe-500D or more.
54Centering and shuttering including strutting, propping etc. and removal of form for
55Columns, Pillars, Piers, Abutments, Posts and Struts
56Lintels, beams, plinth beams, girders, bressumers and cantilevers
57Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
58Structural steel work in single section, fixed with or without connecting plate, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
59Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc.,including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer, including welding and bolted with special shaped washers etc. complete.
60Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
61Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
62Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
63Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
6475 mm bend
6575 mm Shoe
66Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
67Store Room
68Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
69Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
70Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
71Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
721:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
73Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
74All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
75Thermo-Mechanically Treated bars of grade Fe-500D or more.
76Centering and shuttering including strutting, propping etc. and removal of form for
77Columns, Pillars, Piers, Abutments, Posts and Struts
78Lintels, beams, plinth beams, girders, bressumers and cantilevers
79Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, ofapproved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the jointswith white cement and matching pigments etc., complete.
80Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminiumsnap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)1.80 Kg per Sqm
81With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
82Powder coated aluminium (minimum thickness of powder coating 50 micron)10 kg per Sqm
83Pre-laminated particle board with decorative lamination on both sides
84Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles(best make of approved quality) for aluminium doors including necessary cutting and makinggood etc. complete.
85Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300- 550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875- 1987, ISO 800-1984 and IS: 801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ArchitekV2.5.16/ Revitarchitecture- 2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, LShapedAngles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched withdimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchorbolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT.The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
86Providing and fixing of external wall system on Light gauge steel frame work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000,category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make. A grove of 2 mm to 3mm shall be maintained and groves shall be sealed withsilicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm and internal face 12.5mm thick gypsumplaster board fixed on 8mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamlessfinish.(cost of frame work to be paid for separately).
87Providing and fixing in all exterior face panels breathable vapour barrierunderneath the cement fiber board as per National Building Code 2009complete as per direction of Engineer-in-charge.
88Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with selfdrilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm.
89Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183,having density 48 kg/m3, 50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wallwith screw, rawel plug & washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge.
9050 mm PIR insulated roof panel, PPGI/PPGL skin, including fasteners, sealant, trims and installation
91Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
92Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
93Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
9475 mm bend
9575 mm Shoe
96Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
97Store Room Electrical
98Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
99S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
100Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
1015/6 A, 3 pin socket outlet
10215/16 amp , one way switch
10315/16 amp , 6 pin socket outlet
104Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
1053 module
106Supplying and fixing batten/ angle holder including connection etc. as required.
10712-15 watt
10818-22 Watt
109LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
110400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
111S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
112SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
113Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
114Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
115Refree Room
116Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
117Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
118Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
119Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
120Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
1211:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
122Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
123All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
124Thermo-Mechanically Treated bars of grade Fe-500D or more.
125Centering and shuttering including strutting, propping etc. and removal of form for
126Columns, Pillars, Piers, Abutments, Posts and Struts
127Lintels, beams, plinth beams, girders, bressumers and cantilevers
128Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, ofapproved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the jointswith white cement and matching pigments etc., complete.
129Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminiumsnap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)1.80 Kg per Sqm
130With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
131Powder coated aluminium (minimum thickness of powder coating 50 micron)10 kg per Sqm
132Pre-laminated particle board with decorative lamination on both sides
133Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles(best make of approved quality) for aluminium doors including necessary cutting and makinggood etc. complete.
134Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300- 550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875- 1987, ISO 800-1984 and IS: 801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ArchitekV2.5.16/ Revitarchitecture- 2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, LShapedAngles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched withdimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchorbolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT.The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
135Providing and fixing of external wall system on Light gauge steel frame work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000,category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make. A grove of 2 mm to 3mm shall be maintained and groves shall be sealed withsilicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm and internal face 12.5mm thick gypsumplaster board fixed on 8mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamlessfinish.(cost of frame work to be paid for separately).
136Providing and fixing in all exterior face panels breathable vapour barrierunderneath the cement fiber board as per National Building Code 2009complete as per direction of Engineer-in-charge.
137Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with selfdrilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm.
138Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183,having density 48 kg/m3, 50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wallwith screw, rawel plug & washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge.
13950 mm PIR insulated roof panel, PPGI/PPGL skin, including fasteners, sealant, trims and installation
140Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
141Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
142Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
14375 mm bend
14475 mm Shoe
145Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
146Refree Room Electrical
147Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
148S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
149Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
1505/6 A, 3 pin socket outlet
15115/16 amp , one way switch
15215/16 amp , 6 pin socket outlet
153Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
1543 module
155Supplying and fixing batten/ angle holder including connection etc. as required.
15612-15 watt
15718-22 Watt
158LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
159400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
160S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
161SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
162Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
163Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
164Coach Room No 1
165Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
166Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
167Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
168Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
169Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
1701:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
171Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
172All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
173Thermo-Mechanically Treated bars of grade Fe-500D or more.
174Centering and shuttering including strutting, propping etc. and removal of form for
175Columns, Pillars, Piers, Abutments, Posts and Struts
176Lintels, beams, plinth beams, girders, bressumers and cantilevers
177Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, ofapproved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the jointswith white cement and matching pigments etc., complete.
178Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminiumsnap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)1.80 Kg per Sqm
179With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
180Powder coated aluminium (minimum thickness of powder coating 50 micron)10 kg per Sqm
181Pre-laminated particle board with decorative lamination on both sides
182Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles(best make of approved quality) for aluminium doors including necessary cutting and makinggood etc. complete.
183Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300- 550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875- 1987, ISO 800-1984 and IS: 801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ArchitekV2.5.16/ Revitarchitecture- 2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, LShapedAngles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched withdimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchorbolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT.The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
184Providing and fixing of external wall system on Light gauge steel frame work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000,category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make. A grove of 2 mm to 3mm shall be maintained and groves shall be sealed withsilicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm and internal face 12.5mm thick gypsumplaster board fixed on 8mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamlessfinish.(cost of frame work to be paid for separately).
185Providing and fixing in all exterior face panels breathable vapour barrierunderneath the cement fiber board as per National Building Code 2009complete as per direction of Engineer-in-charge.
186Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with selfdrilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm.
187Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183,having density 48 kg/m3, 50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wallwith screw, rawel plug & washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge.
18850 mm PIR insulated roof panel, PPGI/PPGL skin, including fasteners, sealant, trims and installation
189Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
190Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
191Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
19275 mm bend
19375 mm Shoe
194Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
195Coach Room No 1 Electrical
196Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
197S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
198Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
1995/6 A, 3 pin socket outlet
20015/16 amp , one way switch
20115/16 amp , 6 pin socket outlet
202Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
2033 module
204Supplying and fixing batten/ angle holder including connection etc. as required.
20512-15 watt
20618-22 Watt
207LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
208400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
209S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
210SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
211Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
212Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
213Coach Room No 2
214Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
215Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
216Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
217Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
218Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
2191:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
220Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
221All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
222Thermo-Mechanically Treated bars of grade Fe-500D or more.
223Centering and shuttering including strutting, propping etc. and removal of form for
224Columns, Pillars, Piers, Abutments, Posts and Struts
225Lintels, beams, plinth beams, girders, bressumers and cantilevers
226Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, ofapproved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the jointswith white cement and matching pigments etc., complete.
227Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminiumsnap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)1.80 Kg per Sqm
228With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
229Powder coated aluminium (minimum thickness of powder coating 50 micron)10 kg per Sqm
230Pre-laminated particle board with decorative lamination on both sides
231Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles(best make of approved quality) for aluminium doors including necessary cutting and makinggood etc. complete.
232Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300- 550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875- 1987, ISO 800-1984 and IS: 801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ArchitekV2.5.16/ Revitarchitecture- 2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, LShapedAngles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched withdimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchorbolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT.The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
233Providing and fixing of external wall system on Light gauge steel frame work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000,category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make. A grove of 2 mm to 3mm shall be maintained and groves shall be sealed withsilicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm and internal face 12.5mm thick gypsumplaster board fixed on 8mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamlessfinish.(cost of frame work to be paid for separately).
234Providing and fixing in all exterior face panels breathable vapour barrierunderneath the cement fiber board as per National Building Code 2009complete as per direction of Engineer-in-charge.
235Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with selfdrilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm.
236Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183,having density 48 kg/m3, 50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wallwith screw, rawel plug & washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge.
23750 mm PIR insulated roof panel, PPGI/PPGL skin, including fasteners, sealant, trims and installation
238Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
239Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
240Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
24175 mm bend
24275 mm Shoe
243Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
244Coach Room No 2 Electrical
245Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
246S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
247Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
2485/6 A, 3 pin socket outlet
24915/16 amp , one way switch
25015/16 amp , 6 pin socket outlet
251Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
2523 module
253Supplying and fixing batten/ angle holder including connection etc. as required.
25412-15 watt
25518-22 Watt
256LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
257400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
258S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
259SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
260Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
261Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
262Doctor Room
263Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
264Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
265Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
266Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
267Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
2681:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
269Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
270All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
271Thermo-Mechanically Treated bars of grade Fe-500D or more.
272Centering and shuttering including strutting, propping etc. and removal of form for
273Columns, Pillars, Piers, Abutments, Posts and Struts
274Lintels, beams, plinth beams, girders, bressumers and cantilevers
275Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, ofapproved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the jointswith white cement and matching pigments etc., complete.
276Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminiumsnap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)1.80 Kg per Sqm
277With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
278Powder coated aluminium (minimum thickness of powder coating 50 micron)10 kg per Sqm
279Pre-laminated particle board with decorative lamination on both sides
280Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles(best make of approved quality) for aluminium doors including necessary cutting and makinggood etc. complete.
281Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300- 550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875- 1987, ISO 800-1984 and IS: 801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ArchitekV2.5.16/ Revitarchitecture- 2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, LShapedAngles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched withdimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchorbolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT.The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
282Providing and fixing of external wall system on Light gauge steel frame work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000,category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make. A grove of 2 mm to 3mm shall be maintained and groves shall be sealed withsilicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm and internal face 12.5mm thick gypsumplaster board fixed on 8mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamlessfinish.(cost of frame work to be paid for separately).
283Providing and fixing in all exterior face panels breathable vapour barrierunderneath the cement fiber board as per National Building Code 2009complete as per direction of Engineer-in-charge.
284Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with selfdrilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm.
285Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183,having density 48 kg/m3, 50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wallwith screw, rawel plug & washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge.
28650 mm PIR insulated roof panel, PPGI/PPGL skin, including fasteners, sealant, trims and installation
287Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
288Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
289Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
29075 mm bend
29175 mm Shoe
292Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
293Doctor Room Electrical
294Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
295S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
296Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
2975/6 A, 3 pin socket outlet
29815/16 amp , one way switch
29915/16 amp , 6 pin socket outlet
300Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
3013 module
302Supplying and fixing batten/ angle holder including connection etc. as required.
30312-15 watt
30418-22 Watt
305LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
306400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
307S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
308SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
309Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
310Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
311Office Room
312Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
313Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
314Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
315Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
316Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
3171:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
318Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
319All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
320Thermo-Mechanically Treated bars of grade Fe-500D or more.
321Centering and shuttering including strutting, propping etc. and removal of form for
322Columns, Pillars, Piers, Abutments, Posts and Struts
323Lintels, beams, plinth beams, girders, bressumers and cantilevers
324Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, ofapproved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the jointswith white cement and matching pigments etc., complete.
325Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminiumsnap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)1.80 Kg per Sqm
326With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
327Powder coated aluminium (minimum thickness of powder coating 50 micron)10 kg per Sqm
328Pre-laminated particle board with decorative lamination on both sides
329Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles(best make of approved quality) for aluminium doors including necessary cutting and makinggood etc. complete.
330Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300- 550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875- 1987, ISO 800-1984 and IS: 801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ArchitekV2.5.16/ Revitarchitecture- 2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, LShapedAngles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched withdimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchorbolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT.The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
331Providing and fixing of external wall system on Light gauge steel frame work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000,category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make. A grove of 2 mm to 3mm shall be maintained and groves shall be sealed withsilicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm and internal face 12.5mm thick gypsumplaster board fixed on 8mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamlessfinish.(cost of frame work to be paid for separately).
332Providing and fixing in all exterior face panels breathable vapour barrierunderneath the cement fiber board as per National Building Code 2009complete as per direction of Engineer-in-charge.
333Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with selfdrilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm.
334Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183,having density 48 kg/m3, 50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wallwith screw, rawel plug & washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge.
33550 mm PIR insulated roof panel, PPGI/PPGL skin, including fasteners, sealant, trims and installation
336Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
337Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
338Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
33975 mm bend
34075 mm Shoe
341Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
342Office Room Electrical
343Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
344S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
345Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
3465/6 A, 3 pin socket outlet
34715/16 amp , one way switch
34815/16 amp , 6 pin socket outlet
349Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
3503 module
351Supplying and fixing batten/ angle holder including connection etc. as required.
35212-15 watt
35318-22 Watt
354LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
355400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
356S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
357SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
358Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
359Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
360Dressing Room No 1
361Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
362Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
363Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
364Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
365Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
3661:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
367Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
368All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
369Thermo-Mechanically Treated bars of grade Fe-500D or more.
370Centering and shuttering including strutting, propping etc. and removal of form for
371Columns, Pillars, Piers, Abutments, Posts and Struts
372Lintels, beams, plinth beams, girders, bressumers and cantilevers
373Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, ofapproved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the jointswith white cement and matching pigments etc., complete.
374Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
375Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness tobe specified by the manufacturer), of approved make, in all colours, shades except burgundy,bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
376Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminiumsnap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)1.80 Kg per Sqm
377With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
378Powder coated aluminium (minimum thickness of powder coating 50 micron)10 kg per Sqm
379Pre-laminated particle board with decorative lamination on both sides
380Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles(best make of approved quality) for aluminium doors including necessary cutting and makinggood etc. complete.
381Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300- 550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875- 1987, ISO 800-1984 and IS: 801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ArchitekV2.5.16/ Revitarchitecture- 2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, LShapedAngles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched withdimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchorbolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT.The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
382Providing and fixing of external wall system on Light gauge steel frame work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000,category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make. A grove of 2 mm to 3mm shall be maintained and groves shall be sealed withsilicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm and internal face 12.5mm thick gypsumplaster board fixed on 8mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamlessfinish.(cost of frame work to be paid for separately).
383Providing and fixing internal wall panels on Light gauge steel frame work with 12.5mm thick gypsum plaster board conforming IS 2095:2011 fixed on 8mmthick fiber cement board conforming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately)
384Providing and fixing in all exterior face panels breathable vapour barrierunderneath the cement fiber board as per National Building Code 2009complete as per direction of Engineer-in-charge.
385Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with selfdrilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm.
386Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183,having density 48 kg/m3, 50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wallwith screw, rawel plug & washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge.
38750 mm PIR insulated roof panel, PPGI/PPGL skin, including fasteners, sealant, trims and installation
388Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
389Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
390Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
39175 mm bend
39275 mm Shoe
393Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
394Dressing Room No 1 Electrical
395Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
396S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
397Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
3985/6 A, 3 pin socket outlet
39915/16 amp , one way switch
40015/16 amp , 6 pin socket outlet
401Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
4023 module
403Supplying and fixing batten/ angle holder including connection etc. as required.
40412-15 watt
40518-22 Watt
406LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
407400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
40812\\" (300mm) Exhaust fan
409S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
410SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
411Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
412Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
413Dressing Room No 1 Plumbing
414Providing and fixing white vitreous china pedestal type water closet (European type W.C.pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe,with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever requiredW.C. pan with ISI marked white solid plastic seat and lid
415Providing and fixing uplasticised PVC connection pipe with brass unions :
416Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
417Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm diameter
418Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet and 100 mm outlet
419100 mm dia steel Jali
420Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
421Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on walls )25 mm nominal dia Pipes
42232 mm nominal dia Pipes
423Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)15 mm nominal dia Pipes
42420 mm nominal dia Pipes
425Providing and fixing gun metal non- return valve of approved quality (screwed end)25 mm nominal boreHorizontal
426Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
427Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on walls )25 mm nominal dia Pipes
42832 mm nominal dia Pipes
429Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)15 mm nominal dia Pipes
43020 mm nominal dia Pipes
431Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.Horizontal - 25 mm dia
43232 mm nominal bore
433Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS 12818 and making good the same etc. complete as per direction of Engineer-in charge
434Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS :12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Water tank
435Dressing Room No 2
436Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
437Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
438Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
439Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
440Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
4411:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
442Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
443All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
444Thermo-Mechanically Treated bars of grade Fe-500D or more.
445Centering and shuttering including strutting, propping etc. and removal of form for
446Columns, Pillars, Piers, Abutments, Posts and Struts
447Lintels, beams, plinth beams, girders, bressumers and cantilevers
448Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, ofapproved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the jointswith white cement and matching pigments etc., complete.
449Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
450Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness tobe specified by the manufacturer), of approved make, in all colours, shades except burgundy,bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
451Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminiumsnap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)1.80 Kg per Sqm
452With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
453Powder coated aluminium (minimum thickness of powder coating 50 micron)10 kg per Sqm
454Pre-laminated particle board with decorative lamination on both sides
455Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles(best make of approved quality) for aluminium doors including necessary cutting and makinggood etc. complete.
456Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300- 550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875- 1987, ISO 800-1984 and IS: 801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ArchitekV2.5.16/ Revitarchitecture- 2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, LShapedAngles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched withdimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchorbolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT.The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
457Providing and fixing of external wall system on Light gauge steel frame work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000,category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make. A grove of 2 mm to 3mm shall be maintained and groves shall be sealed withsilicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm and internal face 12.5mm thick gypsumplaster board fixed on 8mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamlessfinish.(cost of frame work to be paid for separately).
458Providing and fixing internal wall panels on Light gauge steel frame work with 12.5mm thick gypsum plaster board conforming IS 2095:2011 fixed on 8mmthick fiber cement board conforming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately)
459Providing and fixing in all exterior face panels breathable vapour barrierunderneath the cement fiber board as per National Building Code 2009complete as per direction of Engineer-in-charge.
460Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with selfdrilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm.
461Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183,having density 48 kg/m3, 50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wallwith screw, rawel plug & washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge.
46250 mm PIR insulated roof panel, PPGI/PPGL skin, including fasteners, sealant, trims and installation
463Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
464Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
465Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
46675 mm bend
46775 mm Shoe
468Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
469Dressing Room No 2 Electrical
470Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
471S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
472Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
4735/6 A, 3 pin socket outlet
47415/16 amp , one way switch
47515/16 amp , 6 pin socket outlet
476Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
4773 module
478Supplying and fixing batten/ angle holder including connection etc. as required.
47912-15 watt
48018-22 Watt
481LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
482400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
48312\\" (300mm) Exhaust fan
484S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
485SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
486Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
487Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
488Dressing Room No 2 Plumbing
489Providing and fixing white vitreous china pedestal type water closet (European type W.C.pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe,with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever requiredW.C. pan with ISI marked white solid plastic seat and lid
490Providing and fixing uplasticised PVC connection pipe with brass unions :
491Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
492Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm diameter
493Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet and 100 mm outlet
494100 mm dia steel Jali
495Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
496Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on walls )25 mm nominal dia Pipes
49732 mm nominal dia Pipes
498Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)15 mm nominal dia Pipes
49920 mm nominal dia Pipes
500Providing and fixing gun metal non- return valve of approved quality (screwed end)25 mm nominal boreHorizontal
501Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
502Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on walls )25 mm nominal dia Pipes
50332 mm nominal dia Pipes
504Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)15 mm nominal dia Pipes
50520 mm nominal dia Pipes
506Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.Horizontal - 25 mm dia
50732 mm nominal bore
508Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS 12818 and making good the same etc. complete as per direction of Engineer-in charge
509Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS :12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Water tank
510Gym Room
511Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
512Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
513Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
514Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
515Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
5161:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
517Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
518All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
519Thermo-Mechanically Treated bars of grade Fe-500D or more.
520Centering and shuttering including strutting, propping etc. and removal of form for
521Columns, Pillars, Piers, Abutments, Posts and Struts
522Lintels, beams, plinth beams, girders, bressumers and cantilevers
523Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, ofapproved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the jointswith white cement and matching pigments etc., complete.
524Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
525Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminiumsnap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)1.80 Kg per Sqm
526With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm)
527Powder coated aluminium (minimum thickness of powder coating 50 micron)10 kg per Sqm
528Pre-laminated particle board with decorative lamination on both sides
529Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles(best make of approved quality) for aluminium doors including necessary cutting and makinggood etc. complete.
530Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles(best make of approved quality) for aluminium doors including necessary cutting and makinggood etc. complete.
531Designing, providing, installing and fixing factory finished custom designed cold form Light Gauge Steel Framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. The steel sheet shall be galvanized (AZ-150gms Aluminium Zinc Alloy coated steel having minimum yield strength 300- 550 Mpa) conforming to AISI specifications and IBC 2009 for cold formed steel framing and construction and also as per IS: 875- 1987, ISO 800-1984 and IS: 801- 1975. The wind load shall be as per provisions of IS 875 (part -III). LGSFS frame shall be designed as per IS: 801 using commercially available software such as Frame CAD Pro-11.7/ STAAD PRO-V8i/ArchitekV2.5.16/ Revitarchitecture- 2011 or equivalent. Proper usage of Connection Accessories like Heavy Duty Tension Ties, Light Duty Hold-ons, Twist Straps (to connect truss with wall frames), Strong Tie, Tie Rod, H-Brackets, Boxing Sections, LShapedAngles for better structural stability. The framing section shall be cold form C-type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched withdimple/slot at required locations as per approved drawings. The slots will be along centre line of webs and shall be spaced minimum 250mm away from both ends of the member. The frame can be supplied in panelized or knock down condition in specific dimensions and fastened with screws extending through the steel beyond by minimum of three exposed threads. All self drilling tapping screws for joining the members shall have a Type II coating in accordance with ASTM B633(13) or equivalent corrosion protection of gauge 10 & 12, TPI 16 & 8 of length 20mm. The frames shall be fixed to RCC slab or Tie beam over Neoprene rubber using self expanding carbon steel anchorbolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to AISI 304 and 316 at 500mm c/c with minimum embedment of 100mm in RCC (RCC to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. The item also includes the submission of stability reports duly examined and issued by any NIT/IIT.The rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above.
532Providing and fixing of external wall system on Light gauge steel frame work with . Outer face having 6mm thick heavy duty fiber cement board fixed on 9mm thick heavy duty fiber cement board confirming to IS 14862:2000,category IV type A (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make. A grove of 2 mm to 3mm shall be maintained and groves shall be sealed withsilicon based sealant. The board shall be fixed in a staggered pattern.Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm and internal face 12.5mm thick gypsumplaster board fixed on 8mm thick fiber cement board confirming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamlessfinish.(cost of frame work to be paid for separately).
533Providing and fixing in all exterior face panels breathable vapour barrierunderneath the cement fiber board as per National Building Code 2009complete as per direction of Engineer-in-charge.
534Providing and fixing internal wall panels on Light gauge steel frame work with 12.5mm thick gypsum plaster board conforming IS 2095:2011 fixed on 8mmthick fiber cement board conforming to IS 14862:2000 of category III type B (High pressure steam cured) as per standard sizes fixed with self-drilling / taping screws / fasteners @ 60cm c/c of approved make, Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm. Proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately)
535Supplying and installation of moisture resistant/fire resistant 6 mm thick Heavy duty fiber cement board (High pressure steam cured) conforming to IS 14862:2000 of category III type B as per standard sizes fixed with selfdrilling / taping screws. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick of 8 to 10 gauge of length varying from 25 to 45 mm.
536Providing and fixing thermal insulation with Resin Bonded rock wool conforming to IS: 8183,having density 48 kg/m3, 50 mm thick,wrapped in 200 G Virgin Polythene Bags fixed to wallwith screw, rawel plug & washers and held and in position by criss cossing GI wire etc.complete as per directions of Engineer-in-Charge.
53750 mm PIR insulated roof panel, PPGI/PPGL skin, including fasteners, sealant, trims and installation
538Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
539Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
540Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
54175 mm bend
54275 mm Shoe
543Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
544GUNNEBO Safe Deposit Locker Cabinets As Per IS 5244 (Product id:5116877-92079653883)
545Stainless Steel Bench
546Gym Room Electrical
547Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
548S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
549Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
5505/6 A, 3 pin socket outlet
55115/16 amp , one way switch
55215/16 amp , 6 pin socket outlet
553Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
5543 module
555Supplying and fixing batten/ angle holder including connection etc. as required.
55612-15 watt
55718-22 Watt
558LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
559400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
56012\\" (300mm) Exhaust fan
561S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
562SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
563Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
564Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
565Gym Room Plumbing
566Providing and fixing white vitreous china pedestal type water closet (European type W.C.pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe,with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever requiredW.C. pan with ISI marked white solid plastic seat and lid
567Providing and fixing white vitreous china flat back or wall corner type lipped front urinalbasin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushingcistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clampscomplete, including painting of fittings and brackets, cutting and making good the walls andfloors wherever required :
568White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
569Approved basic rates construction materials for preparation of schedule of rates only, (Material should conform to relevent B.I.S. specification). The rates are inclusive of all taxes, royalty, cess and carraige but exclusive of contractor's profit and overhead charges. Special type of C.P. Bathroom fitting for V.I.P. buildings (JAL, Jaguar, Marc or equivalent mark)Pillar Cock (Long neck) (lSl Marked)
570Bib Cock (Long Thread) (lSl Marked)
571Angular Stop Cock (Long Thread) (lSl Marked
572Toilet Paper Holder
573Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
574Providing and fixing uplasticised PVC connection pipe with brass unions :20 mm nominal bore
575Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodisedaluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mmlong screws, rawl plugs etc., complete.
576Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality)complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screwsand washers complete
577Say 1607.9517.32 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backingRectangular shape 453x357 mm
578Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Pipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
579Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
5801:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
581Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
582Constructing brick masonry chamber for underground C.I. inspection chamber and bendswith bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty)455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement: 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
583Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes75 mm diameter
584110 mm diameter
585Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee without door - 75x75x75 mm
586Single tee without door - 110x110x110 mm
587Single tee with door - 110x110x110 mm
58875 mm bend
589110 mm bend
590Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 100 mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
591100 mm dia steel Jali
592Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
593Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on walls )25 mm nominal dia Pipes
59432 mm nominal dia Pipes
595Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)15 mm nominal dia Pipes
59620 mm nominal dia Pipes
597Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.Horizontal - 25 mm dia
59832 mm nominal bore
599This machine purifies water using UV (Ultra-Violet) technology or a combination of UV and UF (Ultra-Filtration) technology, and is offered with or without a storage tank, and with or without a self-contained water cooler. It is mainly designed for use in offices, commercial premises, industrial facilities, and other comparable environments
600Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
601Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS 12818 and making good the same etc. complete as per direction of Engineer-in charge
602Toilet Room No 1
603Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
604Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
605Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
606Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
607Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
6081:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
609Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
610All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
611Thermo-Mechanically Treated bars of grade Fe-500D or more.
612Centering and shuttering including strutting, propping etc. and removal of form for
613Columns, Pillars, Piers, Abutments, Posts and Struts
614Lintels, beams, plinth beams, girders, bressumers and cantilevers
615Suspended floors, roofs, landings, balconies and access platform
616Weather shed, Chajjas, corbels etc., including edges
617Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
618Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
619Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
62020 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)EXTERNAL PLASTER
62112 mm cement plaster of mix1:4 (1 cement: 4 coarse sand)INTERNAL PLASTER
6226 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
623Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
624Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 0.9 liter/ 10 sqm)
625Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
626Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy,bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.With commercial grade colour tiles.
627Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble Area of slab over 0.50 sqm
628Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
629Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer- in-Charge.
630Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. 30 mm thick pre laminated PVC door shutters
631Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars, including priming coat with approved steel primer, complete.
632Fixed to steel windows by welding
633Fixed to openings /wooden frames with rawl plugs screws etc.22 kg/sqm
634Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approvedbrand and manufacture
635Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This willbe allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
636Toilet Room No 1 Electrical
637Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
638S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
639Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
6405/6 A, 3 pin socket outlet
64115/16 amp , one way switch
64215/16 amp , 6 pin socket outlet
643Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
6443 module
645Supplying and fixing batten/ angle holder including connection etc. as required.
64612-15 watt
64718-22 Watt
648LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
649400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
65012\\" (300mm) Exhaust fan
651S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
652SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
653Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
654Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
655Toilet Room No 1 Plumbing
656Providing and fixing white vitreous china pedestal type water closet (European type W.C.pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe,with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever requiredW.C. pan with ISI marked white solid plastic seat and lid
657Providing and fixing white vitreous china flat back or wall corner type lipped front urinalbasin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushingcistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clampscomplete, including painting of fittings and brackets, cutting and making good the walls andfloors wherever required :
658White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
659Approved basic rates construction materials for preparation of schedule of rates only, (Material should conform to relevent B.I.S. specification). The rates are inclusive of all taxes, royalty, cess and carraige but exclusive of contractor's profit and overhead charges. Special type of C.P. Bathroom fitting for V.I.P. buildings (JAL, Jaguar, Marc or equivalent mark)Pillar Cock (Long neck) (lSl Marked)
660Bib Cock (Long Thread) (lSl Marked)
661Angular Stop Cock (Long Thread) (lSl Marked
662Toilet Paper Holder
663Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
664Providing and fixing uplasticised PVC connection pipe with brass unions :20 mm nominal bore
665Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodisedaluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mmlong screws, rawl plugs etc., complete.
666Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality)complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screwsand washers complete
667Say 1607.9517.32 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backingRectangular shape 453x357 mm
668Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Pipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
669Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
6701:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
671Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
672Constructing brick masonry chamber for underground C.I. inspection chamber and bendswith bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty)455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement: 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
673Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes75 mm diameter
674110 mm diameter
675Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee without door - 75x75x75 mm
676Single tee without door - 110x110x110 mm
677Single tee with door - 110x110x110 mm
67875 mm bend
679110 mm bend
680Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 100 mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
681100 mm dia steel Jali
682Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
683Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on walls )25 mm nominal dia Pipes
68432 mm nominal dia Pipes
685Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)15 mm nominal dia Pipes
68620 mm nominal dia Pipes
687Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.Horizontal - 25 mm dia
68832 mm nominal bore
689This machine purifies water using UV (Ultra-Violet) technology or a combination of UV and UF (Ultra-Filtration) technology, and is offered with or without a storage tank, and with or without a self-contained water cooler. It is mainly designed for use in offices, commercial premises, industrial facilities, and other comparable environments
690Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
691Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS 12818 and making good the same etc. complete as per direction of Engineer-in charge
692Toilet Room No 2
693Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
694Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
695Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
696Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
697Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
6981:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
699Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
700All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
701Thermo-Mechanically Treated bars of grade Fe-500D or more.
702Centering and shuttering including strutting, propping etc. and removal of form for
703Columns, Pillars, Piers, Abutments, Posts and Struts
704Lintels, beams, plinth beams, girders, bressumers and cantilevers
705Suspended floors, roofs, landings, balconies and access platform
706Weather shed, Chajjas, corbels etc., including edges
707Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
708Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
709Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
71020 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)EXTERNAL PLASTER
71112 mm cement plaster of mix1:4 (1 cement: 4 coarse sand)INTERNAL PLASTER
7126 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
713Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
714Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 0.9 liter/ 10 sqm)
715Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
716Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy,bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.With commercial grade colour tiles.
717Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble Area of slab over 0.50 sqm
718Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade
719Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer- in-Charge.
720Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. 30 mm thick pre laminated PVC door shutters
721Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars, including priming coat with approved steel primer, complete.
722Fixed to steel windows by welding
723Fixed to openings /wooden frames with rawl plugs screws etc.22 kg/sqm
724Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approvedbrand and manufacture
725Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This willbe allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured.
726Toilet Room No 2 Electrical
727Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
728S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
729Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
7305/6 A, 3 pin socket outlet
73115/16 amp , one way switch
73215/16 amp , 6 pin socket outlet
733Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
7343 module
735Supplying and fixing batten/ angle holder including connection etc. as required.
73612-15 watt
73718-22 Watt
738LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
739400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
74012\\" (300mm) Exhaust fan
741S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
742SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
743Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
744Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
745Toilet Room No 2 Plumbing
746Providing and fixing white vitreous china pedestal type water closet (European type W.C.pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe,with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever requiredW.C. pan with ISI marked white solid plastic seat and lid
747Providing and fixing white vitreous china flat back or wall corner type lipped front urinalbasin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushingcistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clampscomplete, including painting of fittings and brackets, cutting and making good the walls andfloors wherever required :
748White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
749Approved basic rates construction materials for preparation of schedule of rates only, (Material should conform to relevent B.I.S. specification). The rates are inclusive of all taxes, royalty, cess and carraige but exclusive of contractor's profit and overhead charges. Special type of C.P. Bathroom fitting for V.I.P. buildings (JAL, Jaguar, Marc or equivalent mark)Pillar Cock (Long neck) (lSl Marked)
750Bib Cock (Long Thread) (lSl Marked)
751Angular Stop Cock (Long Thread) (lSl Marked
752Toilet Paper Holder
753Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
754Providing and fixing uplasticised PVC connection pipe with brass unions :20 mm nominal bore
755Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodisedaluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mmlong screws, rawl plugs etc., complete.
756Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality)complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screwsand washers complete
757Say 1607.9517.32 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backingRectangular shape 453x357 mm
758Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Pipes cables etc exceeding 80 mm dia but not exceeding 300 mm dia.
759Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
7601:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
761Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
762Constructing brick masonry chamber for underground C.I. inspection chamber and bendswith bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty)455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement: 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
763Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A, including jointing with sea; ring conforming to IS:5382, leaving 10mm gap for thermal expansion, Single socketed pipes75 mm diameter
764110 mm diameter
765Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee without door - 75x75x75 mm
766Single tee without door - 110x110x110 mm
767Single tee with door - 110x110x110 mm
76875 mm bend
769110 mm bend
770Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors:100 mm inlet and 100 mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
771100 mm dia steel Jali
772Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
773Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on walls )25 mm nominal dia Pipes
77432 mm nominal dia Pipes
775Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)15 mm nominal dia Pipes
77620 mm nominal dia Pipes
777Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.Horizontal - 25 mm dia
77832 mm nominal bore
779This machine purifies water using UV (Ultra-Violet) technology or a combination of UV and UF (Ultra-Filtration) technology, and is offered with or without a storage tank, and with or without a self-contained water cooler. It is mainly designed for use in offices, commercial premises, industrial facilities, and other comparable environments
780Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
781Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS 12818 and making good the same etc. complete as per direction of Engineer-in charge
782Hall Room
783Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soiland disposal of surplus excavated soil as directed, within a lead of 50 m.
784Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
785Excavating, supplying, stacking and filling of local earth (including royalty) by mechanicaltransport upto a lead of 5km also including ramming and watering of the earth in layers notexceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
786Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete.
787Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
7881:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
789Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived fromnatural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cum
790All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
791Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mmnominal size derived from natural sources)
792Thermo-Mechanically Treated bars of grade Fe-500D or more.
793Centering and shuttering including strutting, propping etc. and removal of form for
794Columns, Pillars, Piers, Abutments, Posts and Struts
795Lintels, beams, plinth beams, girders, bressumers and cantilevers
796Providing and laying vitrified floor tiles in different sizes (thickness to be specified bythe manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, ofapproved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the jointswith white cement and matching pigments etc., complete.
797Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness tobe specified by the manufacturer), of approved make, in all colours, shades except burgundy,bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
798Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
799Structural steel work in single section, fixed with or without connecting plate, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
800Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc.,including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer, including welding and bolted with special shaped washers etc. complete.
801Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
802Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thicknessof 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete :
803Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
804Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.75 mm
80575 mm bend
80675 mm Shoe
807Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.
808Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
809Hall Room Electrical
810Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
811S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
812Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
8135/6 A, 3 pin socket outlet
81415/16 amp , one way switch
81515/16 amp , 6 pin socket outlet
816Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
8173 module
818Supplying and fixing batten/ angle holder including connection etc. as required.
81912-15 watt
82018-22 Watt
821LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
822400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
82312\\" (300mm) Exhaust fan
824S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
825SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
826Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
827Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
828Cafeteria Room
829Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil Foundation Excavation work
830Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.Earth Filling at Foundation
831Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.Earth filling for flooing work
832Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.Sand Fliing For flooing work
833Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
8341:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)P.C.C for Footing work P.C.C for flooring Work Steps for enrty
835Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Concrete of M25 grade with minimum cement content of 330 kg /cumFooting work pedestal WorkTie Beam Steps for enrty
836All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cumFloor R.C.C work
837Slab for kitchen
838Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)D.P.C work
839Thermo-Mechanically Treated bars of grade Fe-500D or more.RCC IN FOUNDATIONRCC IN PLINTH BEAMRCC IN PEDESTALRCC FLOORING RCC IN ROOF SLABRCC IN STAIR CASE
840Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concreteFooting Work
841Columns, Pillars, Piers, Abutments, Posts and StrutsPedestsal
842Lintels, beams, plinth beams, girders, bressumers and cantileversTie Beam
843Suspended floors, roofs, landings, balconies and access platform Slab for kitchen
844Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmTiles Flooring Work
845Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointingwith grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.wall tiles wc Wall
846Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.For ISMB column Fixing 1 bolts @ 0.69 kg pr Bolts
847Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
848Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubesSHS 150 x 150 x 6
849Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
850Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usingself drilling/ self tapping screws complete : Gutter (600 mm over all girth)
851Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mm diameterRainwater pipe
852Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler75 mm
853Bend 87.5°75 mm bend
854Shoe (Plain)75 mm Shoe
855Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete.75 mm
856Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding1mtr ms bar wight 1.57 kg per mtr
857Cafeterial Electrical
858Wiring For Light / Fan / Exhaust point with 1.5 Sqm FRLS/ HFFR PVC insulated copper conductor single core cable
859S/F Modular type blanking plate :Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
860Supplying and fixing Modular type switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required5/6 A, one way switch
8615/6 A, 3 pin socket outlet
86215/16 amp , one way switch
86315/16 amp , 6 pin socket outlet
864Supply & fixing following size Modules , GI Box along with modular base & cover plate for modular switch in recess etc . 1 or 2 Module (75mm X75 mm )
8653 module
866Supplying and fixing batten/ angle holder including connection etc. as required.
86712-15 watt
86818-22 Watt
869LED flood Lighting Luminarie with presssuew casr housing and toghened glass cover 50/60 W LED Flood light
870400 mm / 16\\" Wall Mounted Fan, 230V, complete with mounting bracket, regulator, wiring connection, testing & commissioning
87112\\" (300mm) Exhaust fan
872S/F light plug point with modular type accessories :Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
873SUBMAIN WIRING COPPER IN PVC CONDUIT:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
874Suppply & fixing following way , single pole and neutral sheet steel MCB distribution board 240 v on surface 6 way , Double door
875Supplying and fixing 6 amps to 32 amps rating, 240 volts for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.63A rating, MCB,.q
876Cafeteria Plumbing
877Providing and fixing kitchen sink including making all connections excluding cost of fittingsWhite glazed fire clay sink of size 600x450x250 mm
878Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than60 gms
879White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
880Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe andmaking long screws etc. complete (cost of water meter and stop cock to be paid separately).
881Providing and fixing uplasticised PVC connection pipe with brass unions :30 cm length15 mm nominal boreCode Description
88220 mm nominal bore
883Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on walls )25 mm nominal dia Pipes
88432 mm nominal dia Pipes
885Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,)15 mm nominal dia Pipes
88620 mm nominal dia Pipes
887Providing and fixing gun metal non- return valve of approved quality (screwed end)25 mm nominal bore Horizontal
888Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
889Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I. 25 mm nominal boreHorizontal - 25 mm dia
89032 mm nominal bore Horizontal
891Kitchen Room
892Clearing and grubbing land including uprooting rank vegetable grass, bushes, shrubs, saplings and trees upto 300mm
893Earth work in surface excavation by mechanical means for lowering & leveling the ground without blasting for all works other than foundation in Ordinary/Soft rock & depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,In all kinds of soils upto 300 mm depth
894Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface ofconsolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
895Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to completeIn all kinds of soils Depth upto 3 m
896Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete
897Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.
898Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.
899Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances equired to complete the work as per technical specifications.M25 Design Mix Using 20 mm
900Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm
901Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
902Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage & all other appurtenaces required to complete the work.
903Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Column
904Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Beam & Lintel
905Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Slab
906Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. RCC M20
907Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings
908Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
909Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.
910Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )
911Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size – 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
912Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size – 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
913Providing and laying Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm
914Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications
915Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
916Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
917Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
918Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
919Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.
920Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge
921Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
922polyurethane based single Component for New surfaceProviding and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.
923Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
924Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
925Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.
926Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Handles 200mm
927Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Aldrop 16mm dia, 200mm
928Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Tower Bolts 150x10mm
929Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS hinges 125 mm
930Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Door stopper 75mm
931Kitchen Room Electrical
932Concealed Conduit SystemSupplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.
933Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick
93425 mm dia 2 mm thick
935Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010.1.5 mm2
9362.5 mm2
937Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc, complete on the existing metal/PVC box.1 to 2 Module
9383 Module
939Supplying and fixing of modular switch/ Socket/Stepped electronic fan regulator/ dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch
9406A Two Way Switch
9416A Three Way Socket
942Supplying 4 mm thick white plastic plate and covering for junction boxes of size ...... mm conduit using necessary machine screws.110 mm
943Fabricating, supplying and erection of ... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for .......m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top.... mm with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended.7 m - Top 70 mm and Bottom 130 mm dia
9448 m - Top 70 mm and Bottom 135 mm dia
945Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.Single Arm Bracket with 1000 mm Standard 40/50 mm dia
946Supply and Installation / Fixing / Provision of Pole box with HRC Fuse / MCB provision and suitable connector / terminal for 3 Ph/ 1 Ph connections with Loop-In & Loop- Out terminals for 10 mm2 /25 mm2 3.5 C AI/Ar/Cu/Ar Cable and branch out 2.5 mm2 2 core AI/Cu PVC Insulated cable, enclosed in a Thermoplastic, Polystyrene enclosure, which should be shock proof, safe, IP65(Weather Proof), rust proof, dust proof, water proof having Internally Embedded Gasket with provision for cable entry through IP65 Thermoplastic, polyamide glands and/or grommets.200 mm x 200 mm x 98 mm
947Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door4 Way SP & N
9486 Way SP & N
949Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole
950Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.15\\" Sweep (450 mm)
951Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48\\" Sweep (1200 mm) Regular model
952Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply.300 mm Sweep
953Kitchen Room Plumbing
954Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete as per direction of engineer incharge . Concealed work including cutting chases and good the walls etc. 32 mm nominal OD pipes
955Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall32 mm nominal dia Pipes
956Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 40 mm nominal dia Pipes
957Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete as per direction of engineer incharge . Concealed work including cutting chases and good the walls etc. 20 mm nominal OD pipes
958Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete as per direction of engineer incharge . Concealed work including cutting chases and good the walls etc. 15 mm nominal OD pipes
959Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 50 mm dia GM (Copper alloy) Gate valves
960Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
961Providing and placing on terrace (at all floor levels), polyethylene water storage tanks IS:12701 marked, with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, But without Fittings and the base support ofr tank.
962Providing and fixing PTMT bib cock of approved quality and colour. 15 mm nominal bore, 90 mm long, weighing not less than 93 g
963Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete
964Providing and fixing PTMT grating of approved quality and colour 125 mm nominal dia
965Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m
966Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 100 mm nominal dia Pipes
967Providing, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992, IS 4127 with latest amendments, including conveying to work site, caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.150 mm dia. pipes
968Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth
969Constructing brick masonry chamber of internal dimension 600mmX600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..
970The Non Return Valve (NRV) assembly complete with rubber 0 ring
971Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:Pipes of SN 4, 75mm dia. For Vent Pipe
972Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 32 mm dia GM (Copper alloy) Gate valves
973Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..(Item No-16.10, Page No-191, Vol-5 of SR 2023-24)
974Making soak pit 2.5 m diameter 3.0 m deep with 45 x 45 cm dry brick honey comb shaft with bricks and PVC S.W.R drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay (non modular) bricks of class designation 3.5
975Septic Tank
976Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
9771:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
978Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 infoundation and plinth in:Long wallShort WallPartition Wall
979Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :Cement mortar 1:3 (1 cement : 3 coarse sand)
980Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Beam M25
981Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Top SlabBottom Slab
982Thermo-Mechanically Treated bars of grade Fe-500D or more.BeamROOF SLAB
98320 mm cement plaster of mix :BottomSide wall
984Neat cement punning.
985Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey combshaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as perstandard design.
9862.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mminternal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately
987Boundary Wall
988Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kind for soil Boundary Wall
989Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by rammingand watering, lead up to 50 and for all lift.
9901:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources) Below Foundation Boundary Wall
991Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone- III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. Mix 1:3:6 (M10) Using 20 mm CopingBoundary wall
992Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.Total ExcavationBed Concrete M10Beolw GL
993Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 infoundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)Below GL
99420 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand)Boundary Wall
995New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat ofexterior primer applied @ 0.90 litre/10 sqm)
996Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to steel windows by weldingEntrance Gatetaking @ 18kg/sqm
997With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel worksGate
998With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel worksTwo or more coats on new workGate
999Fencing
1000Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc.complete.40X 40 X 6 mm post For boundary wall
1001Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge.Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade
1002Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
1003Paver Block
1004Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in widthas well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 mand lift upto 1.5 m, as directed by Engineer-in- Charge:All kind of soil Paver Block
10051:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)Interlicking paver blockBelow Kerb Stone
1006Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size,design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction ofEngineer-in-charge.
1007Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
1008Painting with synthetic enamel paint of approved brand and manufacture to give an evenshade :Two or more coats
1009Drain
1010Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction ofEngineer-in-charge.
1011Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in widthas well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 mand lift upto 1.5 m, as directed by Engineer-in- Charge:
10121:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stoneaggregate 40 mm nominal size derived from natural sources)
1013Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 infoundation and plinth in:
1014Foundations, footings, bases of columns, etc. for mass concrete
101520 mm cement plaster of mix :
1016Neat cement punning.
1017Rectangular shape 500x500 mm precast R.C.C. manhole cover with frame - M.D. - 10
1018Horticulture
1019Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)
1020Maintenance of hedge for one year including application of necessary pesticide, farm yard manure, replacement of damaged hedge plant by new one complete in all respect as per instruction of Engineer-in-charge. This includes supply of labour, tools & plants including materials.
1021Planting of trees ( Avenue plants) in 0.60m dia holea, 1m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure. This includes supply of labour, tools & plants including materials but excluding cost of tree.
1022Maintanance of trees for one year (Avenue Plants) including watering, trimming, manuring, spraying insecticide and guarding as required. This includes supply of labour, tools & plants including materials.
1023Providing and stacking of Duranta Golden, having ht.15 to 20 cm bushty shape with fresh and healthy leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
1024Providing and stacking of Euphorbia milli hybrid variety, having ht.30 cm to 45 cm with multi branch, full bloom, fresh and healthy leaves in 20 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
1025Providing and Installation of Irrigation & Sprinkler System for Football Ground
1026Fire extingusher system
1027Tubewell
1028Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.All types of soil300 mm dia
1029Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
1030Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia having minimum wall thickness 5.00 mm
1031Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.150 mm nominal size dia
1032Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:150 mm dia
1033Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm dia
1034Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer in-charge.
1035Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
1036Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57516617
AUTHORITY Local Bodies
TENDER VALUE 3.07 Crore
LAST DATE 29-09-2026
Authority
Authority Name Urban Local Bodies
Work Description Tender for Proposed Devolopment Plan Of Gd Block Ground Under Bidhanagar Municipal Corporation
Basic Detail
Tender No NIT No- 543/PWD(BMC), Dated-14/09/2026
Bidding Type Tender
Location
City 24 Paraganas North
State West Bengal
Key Dates
Publish Date 15 Sep 2026
Submission Date 29 Sep 2026
Open Date 01 Oct 2026
Finance
Tender Value 3.07 Crore
Tender Fee Ref. Documents
EMD 6.15 Lakhs
Exemption Not Available
Document List
b714ce50-39e8-4c41-9492-fc67ad9e68ba.html
BOQ_2558155.xls
Tendernotice_1 (39).pdf
Tendernotice_2 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Oct 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

b714ce50-39e8-4c41-9492-fc67ad9e68ba.html

xls

BOQ_2558155.xls

pdf

Tendernotice_1 (39).pdf

pdf

Tendernotice_2 (4).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders