Drinking Water Supply and Sanitation Government Departments Closing in 5 days TDR #57516326

Tender For Leakage Repairing And Interconnection Work Of Various Size Pipelines For Uwss Rawatsar Under City Sub Dn Rawatsar, Div -Nohar

Issued by Government Departments · Hanumangarh, Rajasthan
Tender Value
9.80 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
5 days left
EMD
19600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hanumangarh → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Leakage Repairing And Interconnection Work Of Various Size Pipelines For Uwss Rawatsar Under City Sub Dn Rawatsar, Div -Nohar

BOQ

Name of Work:- Leakage repairing and interconnection work of various size pipelines For UWSS Rawatsar under City Sub Dn Rawatsar, Div -Nohar
Sl. No. Item Description
1Minor repair of leakages such as lead caulking, plugging,clamping and ring fixing in existing Distribution/RisingMain/Transmission Main AC/PVC/HDPE/CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as lead wool, white hump, plugs, clamps etc. shall be provided by Department free of cost)
2In all type Soil AC/PVC/HDPE pipe
350/63/75mm
480/90mm
5100/110mm
6125/140mm
7150/160/180mm
8200/225mm
9250/280mm
10300/315mm
11Add on above item no. 1.3.1 for B.T. Road , 5% Add extra
1250/63/75mm
1380/90mm
14100/110mm
15125/140mm
16150/160/180mm
17200/225mm
18250/280mm
19300/315mm
20Add on above item no. 1.3.1 for C.C. Road.Pit in CC Road shallbe cut in optimum size through CC cutter Machine only. 15% Add extra
2150/63/75mm
2280/90mm
23100/110mm
24125/140mm
25150/160/180mm
26200/225mm
27250/280mm
28300/315mm
29Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost)
30In all type Soil AC/PVC/HDPE pipe
3150/63/75mm
3280/90mm
33100/110mm
34125/140mm
35150/160/180mm
36200/225mm
37250/280mm
38300/315mm
3950/63/75mm
4080/90mm
41100/110mm
42125/140mm
43150/160/180mm
44200/225mm
45250/280mm
46300/315mm
4750/63/75mm
4880/90mm
49100/110mm
50125/140mm
51150/160/180mm
52200/225mm
53250/280mm
54300/315mm
5550/63/75mm
5680/90mm
57100/110mm
58125/140mm
59150/160/180mm
60200/225mm
61250/280mm
62Repairing of leakage in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost)
63In all type Soil
64150mm
65200mm
66250mm
67150mm
68200mm
69250mm
70Replacement of CI/ DI Double flange sluice valves,non return valves,butter fly valves etc. in existing Distribution/Rising Main/Transmission Main pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including providing and fixing MS Nut and Bolt and rubber gasket, dewatering and providing adequate safety arrangement at site and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as Valve, Tail piece, CID Joints etc. shall be provided by Department free of cost)
71In all type Soil
7280 mm
73100 mm
74125 mm
75150 mm
76200 mm
77250 mm
78300 mm
79350 mm
80Removal of Choking from pipe line, including tree roots, malba, sand and other by manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/uPVC pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit.
81In all type Soil
8250/63/75mm
8380/90mm
84100/110mm
85125/140mm
86150/160/180mm
87200/225mm
88250/280mm
89Disconnection of water connection from existing pipe line in all type of soils up to 1.5 mtr depth by digging out suitable size of pit at site of work, with cutting of service line and refixing of clamp revolving it 180 degree then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour.
90Add on above item no. 1.7 for B.T. Road
91Add on above item no. 1.7 for CC Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only.
92Work of Inter Connection in AC/PVC/HDPE pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost).
93In all type Soil
9480 mm to 110 mm
95125 mm to 165 mm
96Labour charges for digging of pit of suitable size for removal of water pollution on existing distribution AC/PVC/uPVC/HDPE pipe lines up to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault in pipe line by fixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. The rate includes all labour charges to complete the work for pipe size
97In all type Soil
9850 to 75 mm
9980-110 mm
100125 to 165 mm
101Dewatering with well point equipment with high pressure diesel operated suction pump including jetting depth 3 to 6m. as per site condition and making arrangements for proper outflow of pumped water etc. complete including labour and POL) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57516326
AUTHORITY Government Departments
TENDER VALUE 9.80 Lakhs
LAST DATE 21-09-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Leakage Repairing And Interconnection Work Of Various Size Pipelines For Uwss Rawatsar Under City Sub Dn Rawatsar, Div -Nohar
Basic Detail
Tender No EE/PHED/NOHAR/E-NIT 14-2026-27 Item 05
Bidding Type Tender
Location
City Hanumangarh
State Rajasthan
Key Dates
Publish Date 14 Sep 2026
Submission Date 21 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 9.80 Lakhs
Tender Fee 500
EMD 19600
Exemption Available
Document List
BOQ_1059780.xls
f80ab0fa-64f0-4861-acdd-3e959c13b1fa.html
td5.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1059780.xls

html

f80ab0fa-64f0-4861-acdd-3e959c13b1fa.html

pdf

td5.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders