Tender For Leakage Repairing And Interconnection Work Of Various Size Pipelines For Uwss Rawatsar Under City Sub Dn Rawatsar, Div -Nohar
Tender Value
9.80 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
5 days left
EMD
19600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hanumangarh → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Leakage Repairing And Interconnection Work Of Various Size Pipelines For Uwss Rawatsar Under City Sub Dn Rawatsar, Div -Nohar
BOQ
| Sl. No. | Item Description |
| 1 | Minor repair of leakages such as lead caulking, plugging,clamping and ring fixing in existing Distribution/RisingMain/Transmission Main AC/PVC/HDPE/CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as lead wool, white hump, plugs, clamps etc. shall be provided by Department free of cost) |
| 2 | In all type Soil AC/PVC/HDPE pipe |
| 3 | 50/63/75mm |
| 4 | 80/90mm |
| 5 | 100/110mm |
| 6 | 125/140mm |
| 7 | 150/160/180mm |
| 8 | 200/225mm |
| 9 | 250/280mm |
| 10 | 300/315mm |
| 11 | Add on above item no. 1.3.1 for B.T. Road , 5% Add extra |
| 12 | 50/63/75mm |
| 13 | 80/90mm |
| 14 | 100/110mm |
| 15 | 125/140mm |
| 16 | 150/160/180mm |
| 17 | 200/225mm |
| 18 | 250/280mm |
| 19 | 300/315mm |
| 20 | Add on above item no. 1.3.1 for C.C. Road.Pit in CC Road shallbe cut in optimum size through CC cutter Machine only. 15% Add extra |
| 21 | 50/63/75mm |
| 22 | 80/90mm |
| 23 | 100/110mm |
| 24 | 125/140mm |
| 25 | 150/160/180mm |
| 26 | 200/225mm |
| 27 | 250/280mm |
| 28 | 300/315mm |
| 29 | Repairing of leakage in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost) |
| 30 | In all type Soil AC/PVC/HDPE pipe |
| 31 | 50/63/75mm |
| 32 | 80/90mm |
| 33 | 100/110mm |
| 34 | 125/140mm |
| 35 | 150/160/180mm |
| 36 | 200/225mm |
| 37 | 250/280mm |
| 38 | 300/315mm |
| 39 | 50/63/75mm |
| 40 | 80/90mm |
| 41 | 100/110mm |
| 42 | 125/140mm |
| 43 | 150/160/180mm |
| 44 | 200/225mm |
| 45 | 250/280mm |
| 46 | 300/315mm |
| 47 | 50/63/75mm |
| 48 | 80/90mm |
| 49 | 100/110mm |
| 50 | 125/140mm |
| 51 | 150/160/180mm |
| 52 | 200/225mm |
| 53 | 250/280mm |
| 54 | 300/315mm |
| 55 | 50/63/75mm |
| 56 | 80/90mm |
| 57 | 100/110mm |
| 58 | 125/140mm |
| 59 | 150/160/180mm |
| 60 | 200/225mm |
| 61 | 250/280mm |
| 62 | Repairing of leakage in existing Distribution/Rising Main/Transmission Main CI/MS/DI pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at at site of work including taking out the burst pipe from trench, dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material, tightening of CID Joints to make repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from Jen store. (Required material such as pipe piece, CID Joints shall be provided by Department free of cost) |
| 63 | In all type Soil |
| 64 | 150mm |
| 65 | 200mm |
| 66 | 250mm |
| 67 | 150mm |
| 68 | 200mm |
| 69 | 250mm |
| 70 | Replacement of CI/ DI Double flange sluice valves,non return valves,butter fly valves etc. in existing Distribution/Rising Main/Transmission Main pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including providing and fixing MS Nut and Bolt and rubber gasket, dewatering and providing adequate safety arrangement at site and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as Valve, Tail piece, CID Joints etc. shall be provided by Department free of cost) |
| 71 | In all type Soil |
| 72 | 80 mm |
| 73 | 100 mm |
| 74 | 125 mm |
| 75 | 150 mm |
| 76 | 200 mm |
| 77 | 250 mm |
| 78 | 300 mm |
| 79 | 350 mm |
| 80 | Removal of Choking from pipe line, including tree roots, malba, sand and other by manually or other means, cleaning of line and testing in existing Distribution/Rising Main/Transmission Main AC/PVC/HDPE/uPVC pipe line up to 1.5 mtr depth of sizes as given below by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site. This will also include cutting of pipe ends, fixing of pipe piece with jointing material and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour and will arrange transportation of required material from store. (Required material such as pipe piece CID Joints shall be provided by Department free of cost)as per satisfaction of EIC. Rates for per pit. |
| 81 | In all type Soil |
| 82 | 50/63/75mm |
| 83 | 80/90mm |
| 84 | 100/110mm |
| 85 | 125/140mm |
| 86 | 150/160/180mm |
| 87 | 200/225mm |
| 88 | 250/280mm |
| 89 | Disconnection of water connection from existing pipe line in all type of soils up to 1.5 mtr depth by digging out suitable size of pit at site of work, with cutting of service line and refixing of clamp revolving it 180 degree then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers for entire job contractor will use his own T&P & labour. |
| 90 | Add on above item no. 1.7 for B.T. Road |
| 91 | Add on above item no. 1.7 for CC Road. Pit in CC Road shall be cut in optimum size through CC cutter Machine only. |
| 92 | Work of Inter Connection in AC/PVC/HDPE pipe line up to 1.5 mtr depth by digging out suitable size of pit at site of work including dewatering and providing adequate safety arrangement at site, cutting of existing pipeline, jointing of Tee (complete) and other specials to make inter connection repair leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. for entire job contractor will use his own T&P & labour and will arrange transportation of material required from store. (Material such as Tee/ Tee Clamp/rubber sheet/ CID joints required for inter connection shall be provided by the department free of cost). |
| 93 | In all type Soil |
| 94 | 80 mm to 110 mm |
| 95 | 125 mm to 165 mm |
| 96 | Labour charges for digging of pit of suitable size for removal of water pollution on existing distribution AC/PVC/uPVC/HDPE pipe lines up to 1.5 mtr depth including cutting of pipe and assessment of direction of flow of polluted water during non supply hours, identifying the source of pollution and repairing of fault in pipe line by fixing of pipe piece with jointing material (pipe and jointing material shall be supplied by department) to make it leak proof and then refilling of excavated tench / pit / road shall be done properly i.e after a layer of 20 cm with proper watering and ramming in layers. The rate includes all labour charges to complete the work for pipe size |
| 97 | In all type Soil |
| 98 | 50 to 75 mm |
| 99 | 80-110 mm |
| 100 | 125 to 165 mm |
| 101 | Dewatering with well point equipment with high pressure diesel operated suction pump including jetting depth 3 to 6m. as per site condition and making arrangements for proper outflow of pumped water etc. complete including labour and POL) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender