Drinking Water Supply and Sanitation Government Departments Closing in 5 days TDR #57516288

Tender For Work Of Repair Of Panel/Starter Spare Parts On Urban Water Supply Schemes Under Jen Section Urban Of Sub Division Nohar, District Hanumangarh.

Issued by Government Departments · Hanumangarh, Rajasthan
Tender Value
8.30 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
5 days left
EMD
16600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Hanumangarh → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Work Of Repair Of Panel/Starter Spare Parts On Urban Water Supply Schemes Under Jen Section Urban Of Sub Division Nohar, District Hanumangarh.

BOQ

Name of Work:- Work of Repair of panel/starter spare parts on Urban Water Supply Schemes under JEn Section Urban of Sub Division Nohar, District Hanumangarh.
Sl. No. Item Description
16.1 Labour charges for removing electric fault in wiring / making connection through lugs (with the help of cramping tool) of motor pump set with starter at headworks of water supply scheme/Tubewell/ openwell including cost of insulation tape etc.
26.2 Labour charges for replacement of defective ampere meter / volt meter with new one on existing panel board in pump house./Tubewell /openwell (new voltmeter/ampere meter will be provided by department
36.3 Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Department)
45 to 15 HP
516 to 30 HP
631 to 60 HP
761 to 100 HP
8101 to 150 HP
96.4 Labour charges for repairing of soft starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Department)
1016 to 30 HP
116.5 Supply & filling starter oil in oil immersed starters at site.
12SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following Current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 3 pole MCCB With Thermal Magnetic release
13up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
14160 Amp , 25 kA, adjustable O/L & fixed S/C setting,
15400 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
16630 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
17Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.
18Up to 14 Amp
1914 to 23 Amp
2020 to 33 Amp
2124 to 40 Amp
22Providing & Fixing of selector switch of 10 A for voltmeter using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. Switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required .Voltage Between Phases with OFF ( 4 Position )
23Providing & Fixing of CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required .
24Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. 1 x 4.0 sq.mm
25---do---1x6.0 sq.mm.
26Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.120201 2 x 4.0 sq.mm120201.2 Complete Rate
272 x 6.0 sq.mm
28Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required.
296 A to 32 A rating
30double pole MCB 6 A to 32 A rating
31Triple pole MCB 6 A to 32 A rating
32Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.
33Upto 6 KVAR
348.5 KVAR
35Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, life expectancy greater than 100000hrs (temp class - 25 D) in 440 V including making connections, testing etc. as required.Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank)
36Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. 8.16.1 3 pole Power contactors with following AC 3 Rating
37Up to 12 Amp
38---do---13 to 25 Amp
39---do---32 Amp.
40---do---40 Amp
41---do---50 Amp
42---do---70 Amp
43---do---80 Amp
44---do---95 Amp
45---do---140 Amp
462.19 Supply and Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
473 core 6.0 Sq.mm
483 core 10.0 Sq.mm
493 core 16.0 Sq.mm
50Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS: 7098 Part-1 of 1.1 KV with H-4 Grade electrolytically pure aluminium conductor confirming to IS 8130 of purity >99.6%, round / flat strip armouring of cables, inner / outer sheath confirming to IS: 5831 in existing RCC / Hume / Stoneware / PVC pipe / open duct/cable trench/cable tray (with cable tie) including testing etc. as required of following size.
513.5 core 70 sqmm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57516288
AUTHORITY Government Departments
TENDER VALUE 8.30 Lakhs
LAST DATE 21-09-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Work Of Repair Of Panel/Starter Spare Parts On Urban Water Supply Schemes Under Jen Section Urban Of Sub Division Nohar, District Hanumangarh.
Basic Detail
Tender No EE/PHED/NOHAR/E-NIT 14-2026-27 Item 09
Bidding Type Tender
Location
City Hanumangarh
State Rajasthan
Key Dates
Publish Date 14 Sep 2026
Submission Date 21 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 8.30 Lakhs
Tender Fee 500
EMD 16600
Exemption Available
Document List
BOQ_1059799.xls
cd3f09ee-17e7-45a9-a149-68e452c5dee0.html
td9.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1059799.xls

html

cd3f09ee-17e7-45a9-a149-68e452c5dee0.html

pdf

td9.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders