Tender For Work Of Repair Of Panel/Starter Spare Parts On Urban Water Supply Schemes Under Jen Section Urban Of Sub Division Nohar, District Hanumangarh.
Tender Value
8.30 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
5 days left
EMD
16600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hanumangarh → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Work Of Repair Of Panel/Starter Spare Parts On Urban Water Supply Schemes Under Jen Section Urban Of Sub Division Nohar, District Hanumangarh.
BOQ
| Sl. No. | Item Description |
| 1 | 6.1 Labour charges for removing electric fault in wiring / making connection through lugs (with the help of cramping tool) of motor pump set with starter at headworks of water supply scheme/Tubewell/ openwell including cost of insulation tape etc. |
| 2 | 6.2 Labour charges for replacement of defective ampere meter / volt meter with new one on existing panel board in pump house./Tubewell /openwell (new voltmeter/ampere meter will be provided by department |
| 3 | 6.3 Labour charges for repairing of starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Department) |
| 4 | 5 to 15 HP |
| 5 | 16 to 30 HP |
| 6 | 31 to 60 HP |
| 7 | 61 to 100 HP |
| 8 | 101 to 150 HP |
| 9 | 6.4 Labour charges for repairing of soft starter at site including opening and reassembling of starter with labour charges for replacing of defective parts with new one at site.(Parts will be supplied by Department) |
| 10 | 16 to 30 HP |
| 11 | 6.5 Supply & filling starter oil in oil immersed starters at site. |
| 12 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following Current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 3 pole MCCB With Thermal Magnetic release |
| 13 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 14 | 160 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 15 | 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 16 | 630 Amp , 50 kA, adjustable O/L & adjustable S/C setting, |
| 17 | Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. |
| 18 | Up to 14 Amp |
| 19 | 14 to 23 Amp |
| 20 | 20 to 33 Amp |
| 21 | 24 to 40 Amp |
| 22 | Providing & Fixing of selector switch of 10 A for voltmeter using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. Switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required .Voltage Between Phases with OFF ( 4 Position ) |
| 23 | Providing & Fixing of CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required . |
| 24 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. 1 x 4.0 sq.mm |
| 25 | ---do---1x6.0 sq.mm. |
| 26 | Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size.120201 2 x 4.0 sq.mm120201.2 Complete Rate |
| 27 | 2 x 6.0 sq.mm |
| 28 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. |
| 29 | 6 A to 32 A rating |
| 30 | double pole MCB 6 A to 32 A rating |
| 31 | Triple pole MCB 6 A to 32 A rating |
| 32 | Providing & Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. |
| 33 | Upto 6 KVAR |
| 34 | 8.5 KVAR |
| 35 | Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, life expectancy greater than 100000hrs (temp class - 25 D) in 440 V including making connections, testing etc. as required.Heavy duty Three phase 440 V, 50 Hz cylindrical type capacitor (Bank) |
| 36 | Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. 8.16.1 3 pole Power contactors with following AC 3 Rating |
| 37 | Up to 12 Amp |
| 38 | ---do---13 to 25 Amp |
| 39 | ---do---32 Amp. |
| 40 | ---do---40 Amp |
| 41 | ---do---50 Amp |
| 42 | ---do---70 Amp |
| 43 | ---do---80 Amp |
| 44 | ---do---95 Amp |
| 45 | ---do---140 Amp |
| 46 | 2.19 Supply and Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. |
| 47 | 3 core 6.0 Sq.mm |
| 48 | 3 core 10.0 Sq.mm |
| 49 | 3 core 16.0 Sq.mm |
| 50 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS: 7098 Part-1 of 1.1 KV with H-4 Grade electrolytically pure aluminium conductor confirming to IS 8130 of purity >99.6%, round / flat strip armouring of cables, inner / outer sheath confirming to IS: 5831 in existing RCC / Hume / Stoneware / PVC pipe / open duct/cable trench/cable tray (with cable tie) including testing etc. as required of following size. |
| 51 | 3.5 core 70 sqmm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender