Tender For Providing Of Three Standalone Central Heating System For Repair Renovation Bn Under Ge 865 Ews
Tender Overview
Project Description
Tender For Providing Of Three Standalone Central Heating System For Repair Renovation Bn Under Ge 865 Ews
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Sep-2026 | REVISION OF BOQ | BOQ | 05-Oct-2026 |
| 2 | 05-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 12-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning of ductable type stand alone oil-fired kerosene/ HSD based heating system complete with stainless steel heat exchanger chamber consisting of furnace fabricated out of high temperature resistance stainless steel, automatic burner assembly control panel with sequence controller, photocell for flame failure. HT Transformer electrode fan assembly with motor temperature controller stainless steel reflector, built in fuel oil piping exhaust chimney all housed in powder coated casing suitable for operation on 50 Hz single phase 230 Volt AC supply capacity 75,000 Kilo Cal/hr including fuel container of suitable capacity with following :-(a) Heat Output - 75000 Kilo Cal/Hr.(b) Hot Air Temp - 40 degree Celcius(c) Temperature Rise - 90 degree Celcius Max(d) Fuel Consumption - 5.2 - 5.6 Ltr/Hr(e) Thermal Efficiency - minimum 80%(f) Electrical Supply - 220 Volts 50 Hz(g) Temperature Control - Automatic(h) Fuel - Kerosene/ Diesel |
| 2 | Design, supply, fixing and testing ducting for hot air blower to room with complete insulation of the duct, complete all as specified and/or as directed by Engr-in-Charge. |
| 3 | S&F sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 4 Ways, complete all as specified and/or as directed by Engr-in-Charge. |
| 4 | S&F MCB SPN 40 Amp 240 Volts AC ISI marked, complete all as specified and/or as directed by Engr-in-Charge. |
| 5 | S&F MCB SP 6-32 Amps. 240 Volts 50 Hz, complete all as specified and/or as directed by Engr-in-Charge. |
| 6 | M&L for submain wiring along with earth wire with the sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing caping wire size 2 x 4.0 sqmm + 1 x 4 sqmm earth wire, complete all as specified and/or as directed by Engr-in-Charge. |
| 7 | S&F sheet metal enclosure with 20 Amp 240 V socket plug top and MCBs single pole and neutral enclosure with two pin and earth plug and socket with one single pole 20 Amp MCB, complete all as specified and/or as directed by Engr-in-Charge. |
| 8 | M&L for earthing complete with galvanised steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including 4 mm dia GI wire as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 3 of MES SSR Part I and testing on completion including excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS frame and cover 6 mm thick in cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric or XPM (weight not less than 4 Kg per Sqm) with cast iron frame, funnel with wire mesh, GI watering pipe 20mm dia medium grade and lugs, complete all as specified and/or as directed by Engr-in-Charge. |
| 9 | S&F tubes light grade of size 40 mm bore galvanised with all fittings and fixed complete to walls and ceiling or laid in floors, complete all as specified and/or as directed by Engr-in-Charge. |
| 10 | Supply and laying in trenches or passing through pipe or fixed on surface XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade of size 16 sqmm 2 core, complete all as specified and/or as directed by Engr-in-Charge. |
| 11 | M&L for making of foundation for standalone CHS of capacity 75000 Kilo Cal, as per manufacturer's instructions and as required at site, complete all as specified and/or as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender