Tender For Special Repair To Lt Cable, Lt Panel & Lt Poles Alongwith Connected Accessories For 404 Lt Ad Regt And Provn Of 01 X Deep Freezer Of 300 Ltrs Capacity At Corps Officers Under Ge 865 Ews, Leh
Tender Overview
Project Description
Tender For Special Repair To Lt Cable, Lt Panel & Lt Poles Alongwith Connected Accessories For 404 Lt Ad Regt And Provn Of 01 X Deep Freezer Of 300 Ltrs Capacity At Corps Officers Under Ge 865 Ews, Leh
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5m in wide and not exceeding 1.5 m in depth for laying of pipe etc and getting out in hard soil, complete all as specified and directed. |
| 2 | All as per Ser item No 1.00 here-in-before exc 1.5m but n. exc 3m in depth. |
| 3 | M&L for Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Par-I, all as specified and directed. |
| 4 | Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-1 flate size 250mm x 150mm x 40mm, complete all as specified and directed |
| 5 | Labour only for laying of old serviceable cable covers retrieved from excavation complete all as specified and directed. |
| 6 | M & L for returning, filling in including spreading leveling watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed. |
| 7 | M & L for removing surplus soil to a distance not exc. 50 M and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed. |
| 8 | M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, filling mass concrete including necessary form work, complete all as specified and directed. |
| 9 | M&L for PCC 1:3:6 type C 1 using 20 mm graded aggregate block masonry with solid block ,exc 10 cm in width and setting in mortar complete for coping of pole including necessary from work and fair finish to the exposed surface area without using extra cement complete all as specified and directed. |
| 10 | M&L for cement concrete in foundation, filling and mass concrete type B2 1:2:4 with using 40mm aggregate, complete all as specified and directed. |
| 11 | Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed. |
| 12 | Supply and fixing in repair Steel tubular swaged street light poles complete with pole arms 1.2 m & cast iron base plate ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 9.0 mtr long and painting with two coat of aluminium paint over one coat of primer on exposed surface of pole all as specified and directed by Engr-in-Charge.( NOTE- Excavation & PCC will be measured and paid separately) |
| 13 | Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 240 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified. |
| 14 | Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified. |
| 15 | Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 70 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified. |
| 16 | Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 25 Sqmm 2.0 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified. |
| 17 | Taking down old unserviceable feeder pillar box and supply and fix in replacement feeder pillar box of suitable size with incommer MCCB of cpacity 160 Amps, 415V and 4 Nos aluminium bus bar strip along with 14 Nos MCB SPN 63 Amps, 240 Volts, C type with Din rail for moounting and necessary wiring for MCB,s complete size all as specified and directed. |
| 18 | Supply , Installation and Commissioning of Deep freezer Metal top of capacity 300 Litres having double door ,single phase 240 volts 50 Hz complete all as per speified and directed. Make- Voltas/Blue Star/Hitachi/LG/Samsung |
| 19 | M&L for Point wirnig for Power point 3 pin switch socket 15 Amp with PVC copper conductor cable multistrand unsheathed 2.5 Sqmm on independent board incl one run 1.5 Sqmm multistrand PVC copper conductor cable for earth continuity in and including PVC casing and capping fixed on wall complete all as specified and as directed. |
| 20 | Supply and fixing modular switch single pole one way 16 Amps 1 module complete all as specified and directed by Engr in Charge. |
| 21 | Supply and fix modular socket 6 A/16 amp -2/3 pin combined 2 module complete all as specified and directed. |
| 22 | Supply & fix metal flush box 3 module Complete all as specified and directed. |
| 23 | Supply & fix white cover plate with frame (inner plate) 3 module complete all as specified and directed. |
| 24 | Deduct Schedule of Credit of Rs (-) 18429.50 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount.Note :- Tenderers will not quote against this item being a firm amount. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender