Tender For Construction Of 3 Nos. Reinforced Cement Concrete Box Culvert At Garlabari Dekadambra Village Under Sopd-G-V-Be Fund For The Year 2026-27.
Tender Value
25.04 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
19 days left
EMD
50080
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kokrajhar → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 3 Nos. Reinforced Cement Concrete Box Culvert At Garlabari Dekadambra Village Under Sopd-G-V-Be Fund For The Year 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | RCC BOX CELL Bridge, (1 Cell, size-1.00m x 1.00m) |
| 2 | Earth work in excavation for structures as per drawings and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m..1. Ordinary soil. |
| 3 | Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9 |
| 4 | Providing concerete for plain/reinforced concrete in open foundation complete as per drawing and Technical Specification Clause 802.803, 1202 & 1203. B. With natural gravel. |
| 5 | Providing concerete for plain/reinforced concrete in open foundation complete as per drawing and Technical Specification Clause 802.803, 1202 & 1203...B. With natural gravel. |
| 6 | Plain/reinforced cement concrete in sub-structure complete as per drawing and technical specifications Clauses 802,804,805,806,807, 1202 and 1204. (B) With natural gravel. |
| 7 | Supplying, fitting & placing HYSD reinforcement (Fe 415) in sub structure complete as per drawing and technical specifications Clauses 1002, 1005, 1010 & 1202. |
| 8 | Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications clause 800 & 1206.3 ….A. with Natural gravel. |
| 9 | Back filling behind abutment, wing wall return wall as per drawing and technical specifications Clauses 1204.3.8 |
| 10 | Providing and laying curtain walls complete as per drawing and technical specifications clauses 1304…. III. Cement concrete grade M10. |
| 11 | RCC BOX CELL Bridge, (1 Cell, size-2.00m x 2.00m) |
| 12 | Earth work in excavation for structures as per drawings and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m..1. Ordinary soil. |
| 13 | Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9 |
| 14 | Providing concerete for plain/reinforced concrete in open foundation complete as per drawing and Technical Specification Clause 802.803, 1202 & 1203. B. With natural gravel. |
| 15 | Providing concerete for plain/reinforced concrete in open foundation complete as per drawing and Technical Specification Clause 802.803, 1202 & 1203...B. With natural gravel. |
| 16 | Plain/reinforced cement concrete in sub-structure complete as per drawing and technical specifications Clauses 802,804,805,806,807, 1202 and 1204. (B) With natural gravel. |
| 17 | Supplying, fitting & placing TMT reinforcement (Fe 500D) in sub structure complete as per drawing and technical specifications Clauses 1002, 1005, 1010 & 1202. |
| 18 | Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications clause 800 & 1206.3 ….B. with crushed stone. |
| 19 | Construction of RCC railling of M25 grade in cast-in situ with 20 mm nominal size aggregate, true to line and grade tolerence of vertical railling post not to exceed 1 in 500, centre to centre spacing between verrtical posts not to exceed 2000 mm as per |
| 20 | Providing weep holes in brick masomy/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe through the full width of structure with slope IV:20H towards drawing force complete as per drawing and technical specification. |
| 21 | Providing and laying curtain walls complete as per drawing and technical specifications clauses 1304…. III. Cement concrete grade M15. |
| 22 | Back filling behind abutment, wing wall return wall as per drawing and technical specifications Clauses 1204.3.8 |
| 23 | Drainage spouts complete as per drawing and technical specification Clauses 1209. |
| 24 | Construction of embankment with approved martial obtained from borrow pits with a lift up to 1.5 m transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 I Private Land |
| 25 | RCC BOX CELL Bridge, (1 Cell, size-2.00m x 2.00m) |
| 26 | Earth work in excavation for structures as per drawings and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m..1. Ordinary soil. |
| 27 | Filling in foundation trenches as per drawing and Technical Specification Clause 305.3.9 |
| 28 | Providing concerete for plain/reinforced concrete in open foundation complete as per drawing and Technical Specification Clause 802.803, 1202 & 1203. B. With natural gravel. |
| 29 | Providing concerete for plain/reinforced concrete in open foundation complete as per drawing and Technical Specification Clause 802.803, 1202 & 1203...B. With natural gravel. |
| 30 | Plain/reinforced cement concrete in sub-structure complete as per drawing and technical specifications Clauses 802,804,805,806,807, 1202 and 1204. (B) With natural gravel. |
| 31 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800,1205.4 and 1205.5. |
| 32 | Supplying, fitting & placing HYSD reinforcement (Fe 415) in sub structure complete as per drawing and technical specifications Clauses 1002, 1005, 1010 & 1202. |
| 33 | Supplying, fitting & placing HYSD reinforcement (Fe 415) in super structure complete as per drawing and technical specifications Clauses 1002, 1010 & 1202. |
| 34 | Providing and laying cement concrete wearing course M30 grade including reinforcement complete as per drawing and technical specifications clause 800 & 1206.3 B. Withn Natural gravel. |
| 35 | Providing weep holes in brick masomy/plain/reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe through the full width of structure with slope IV:20H towards drawing force complete as per drawing and technical specification. |
| 36 | Construction of RCC railling of M25 grade in cast-in situ with 20 mm nominal size aggregate, true to line and grade tolerence of vertical railling post not to exceed 1 in 500, centre to centre spacing between verrtical posts not to exceed 2000 mm as per |
| 37 | Back filling behind abutment, wing wall return wall as per drawing and technical specifications Clauses 1204.3.8 |
| 38 | Providing and laying curtain walls complete as per drawing and technical specifications clauses 1304…. III. Cement concrete grade M15. |
| 39 | Construction of flexible apron 1 m thick comprising of loose stone boulders weighing less than 25kg beyond curtain wall |
| 40 | Construction of embankment with approved martial obtained from borrow pits with a lift up to 1.5 m transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 I Private Land |
| 41 | Supplying, fitting & fixing of signboard L/S Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender